N388DA
Service difficulty reports · 122
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N388DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N388DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2014121506540Skin · corrodedDURING INSPECTION, FOUND CORROSION ON FUSELAGE SKIN AFT LAVATORY VENT SURROUND STRUCTURE. MAINTENANCE REPAIRED IAW ERA 521636-14.SDR DALA2014101305504Terminal · brokenAIR TURNBACK DURING CLIMB, THE NR 1 ENGINE FIRE INDICATION LIGHT ILLUMINATED WITH ALARM BELL. ACFT RETURNED TO DEPARTURE. MAINTENANCE REPLACED COCKPIT FIRE PANEL AND FIRE DETECTION CONTROL MODULE. FOUND TERMINAL BROKEN ON HARNESS MW0316 REPLACED SAME. REPSDR DALA2014101305503Fire Loop · inoperativeDURING CLIMB, THE NR 1 ENGINE FIRE INDICATION ILLUMINATED WITH ALARM BELL. AIRCRAFT RETURNED TO DEPARTURE. MAINTENANCE FOUND THE B LOOP INOPERATIVE.SDR DALA2014080604340Skin · damagedDURING INSPECTION, FOUND FUSELAGE SKIN DAMAGED BS 837 S25-27R. REPAIRED IAW ERA 517969.SDR DALA14004753718Door Frame · damagedDURING INSPECTION, FOUND DOORWAY AFT FRAME HAS DAMAGE ON WEB. MAINTENANCE REPAIRED IAW ERA 522414-14, REV O.SDR DALA1400223718Door Frame · damagedDAMAGE AROUND THE AFT E/E DOOR LATCH HOLE ON THE LOWER FRAME WEB AT BS 351.2 AND BL 0. DAMAGE CAUSED BY POSSIBLE IMPROPER RIGGING OF THE E/E DOOR THE DAMAGE WAS CUT OUT AND REPAIRED IAW SRM 51-70-13, REPAIR 1.SDR DALA14003273718Floorbeam · crackedDURING INSPECTION FOUND FLOORBEAM CRACKED AT BS 727B RBL 24.75, LBL 45.5, AND RBL 45.5. MAINTENANCE REPAIRED 522339-14AD.SDR DALA13070013718Skin · crackedDURING INSPECTION, FOUND LAVATORY VACUUM EXHAUST PORT HAS TWO CRACKS IN FUSELAGE SKIN 6 O`CLOCK POSITION. MAINTENANCE COMPLIED WITH A PERMANENT REPAIR IAW ERA 521636-14.SDR DALA13041793718Skin · dentedDURING INSPECTION, FOUND FUSELAGE SKIN IS DENTED AND TORN AT FS 837 BETWEEN S-26R AND S-27R. THE STRINGER WAS ALSO DAMAGED AT THAT LOCATION. MX REPAIRED IAW ERA 517969-14.SDR DALA13041893718Keelbeam · damagedDURING INSPECTION, FOUND BS 800, BL 0, OTBD SIDE OF KEEL BEAM LOWER RT ANGLE LEG HAS DAMAGE. MX REPAIRED DAMAGE IAW ERA 518028-14, REV 0 AND REV 2.SDR DALA1316223718Structure · damagedINBD AFT LT FLAP DAMAGED. LOWER SKIN DENTED AND PUNCTURED 19-35 INCHES FROM OTBD END. REPAIR IAW ERA 516256-14, ERA-516256-14.SDR DALA1302303718Battery Pack · failedDURING TESTING, EMERGENCY ESCAPE PATH LIGHTING BATTERY PACKS M1675, M1676 FAILED THE CAPACITY TEST. MX REPLACED BATTERY PACKS M1675, M1676 IAW AMM 33-51-06. OPS CHECK OK.SDR DALA1301703718Wire · brokenDURING INSPECTION, SEAT 30 EMERGENCY PATH LIGHT INOPERATIVE. MX REPAIRED BROKEN WIRE AT SIDEWALL ROW 30F IAW SWPM CHAPTER 20. OPS CHECK OK.SDR DALA1204783718Pressure Panel · crackedPRESSURE DECK WEB AT STA 663 RBL 42 CRACKED. REPAIRED IAW ERA 498932-14 REV ORIGINAL.SDR DALA1204793718Stringer · crackedSTR 8 CRACKED AT STA 400-420. REPAIRED IAW ERA 498930-14AD ORIG.SDR DALA1204673718Floorbeam · corrodedAFT FLOORBEAM STA 947 RBL 48 CORRODED. REPAIRED IAW 53-70-51.SDR DALA1204663718Tee Fitting · corrodedAFT GALLEY FLOOR STRUCTURE STA 986.5 T-CAP WAS CORREDED ACCROSS ENTIRE LENTH. REPAIRED IAW SRM 53-70-51.SDR DALA1162343718Battery · failedBATTERIES FOR 7 OF THE 9 EMERGENCY EGRESS LIGHTING POWER SUPPLIES, FAILED FUNCTIONAL CHECK. INSTALLED SERVICEABLE BATTERIES AT POWER SUPPLIES M1674, M1695, M1694, M1671, M1670, M16712, AND M1673. PASSED TEST.SDR DALA1015050388Light · inoperativeEMERGENCY EGRESS LIGHTING INOP AT ROW 11D OVERHEAD AND SEAT 24D. RE-LAMPED 11D, REPAIRED WIRING AT 24D, CHECKS OK.SDR DL738040278Door · unsecureL(1) DOOR DID NOT SEAL ON CLIMB-OUT PREVENTING AIRCRAFT FROM PRESSURIZING. FOUND DOOR NOT SHUT PROPERLY. INSPECTED DOOR AND OPS CHECKS GOOD.SDR DL738031148Anti-Ice Valve · failedNR 2 ENG COWL ANTI-ICE LIGHT ILLUMINATED DURING T/O ROLL. ABORTED AT 50 KTS N1 89 PERCENT. REPLACED NR 2 AIV, OPS CHECKS OK.SDR DL738030390Bulb · burned outRIGHT OVERWING AFT EMERGENCY LIGHT INOP. RELAMPED SAME, OPS CHECK GOOD.