N38950
Service difficulty reports · 34
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N38950' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N38950' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026071017652Light · faultedTHE GENERAL ILLUM EMERGENCY LIGHT IN OVERHEAD BIN 53D & 53G WERE FLICKERTING. REFER TO HAECO NR 9759044, WORK RAISED FROM 10-3350-1-7501. REPLACED GENERAL ILLUMINATION LIGHTS IN OVERHEAD BIN 53D & 53G. PERFORMED INSTALLATION TEST, FOUND NORMAL IAW AMM 33-51-0SDR CALA2026071017650Light · malfunctionedFOUND THE FLOOR PROXIMITY LIGHT FLASH AT SEAT 9D FWD. REFER TO HAECO 9458969, WORK RAISED FROM 10-3350-1-7501. REPLACED FLOOR PROXIMITY LIGHT AT SEA 9D FWD. PERFORMED INSTALLATION TEST, THE RESULT FOUND NORMAL IAW AMM 33-51-06-00A-720A/520A-A REV 209.SDR CALA2026052016389Light · damagedDURING CABIN CHECK WAS FOUND EMERGENCY PATH LIGHT AT SEAT 8D DAMAGED. CONFIRMED SEAT 4F DAMAGED. REMOVED AND REPLACED EMERGENCY LIGHT AT SEAT 8D AND 4F AS REF CMM 25-26-36. ITEM GOOD FOR FLIGHT.SDR CALA2025110510920Lock · faultedDOOR FLT LOCK LOCKED R4 DOOR FLIGHT LOCK ENGAGED AND DISENGAGED NEAR & FAR STATUS IS NOT CONSISTENT WITH STATUS OF FLIGHT LOCK COMMAND, IN THE ENGAGED POSITION. REQUESTING MEL 5211S FOR HISTORY OF DOOR 4R. VERIFIED THE ASSOCIATED PASSENGER ENTRY DOOR IS CAPABSDR CALA2025080607371Warning Message · false activationDOOR FLT LOCK LOCKED 4R MMSG 42-23504 R CCS-CROWN-DR3 NETWORK SWT / NOT ACTIVE. PFMD FIM 42-30-F1-85A-421A TASK GND TEST TO RESET R CCS-CROWN DR3 PASSED. ENTRY DR FLT LOCK CTL OPS TEST PASSED PER AMM B787-A-52-11-25-01A-320A-A AND STS MSG CLEARED. ESCAPE SLIDESDR CALA2025063006036Battery · no testAHM DETECTED WELS MMSG {33-12114} CLASS 14 - REMOTE WELS CONTROL UNIT CONFIGURATION DOES NOT AGREE WITH OTHER WIRELESS EMERG LIGHTING SYS CONTROL UNITS REF FIM DMC-B787-A-33-50-F1-V7A-421A-A TO CONFIRM FAULT. CON'T FAULT ISOLATION AS REQ'D. REF CONFIG DWG 252SDR CALA2025051904791Battery Pack · faultedFLASHLIGHT (PASSENGER CABIN)INOPERATIVE 3R REPLACE FLASHLIGHT REPLACEMENT BATTERY REQUIRED, ENTIRE STOCK OF TORCH BATTERIES LOCATED IN HANGAR, NIL AVAILABLE AT LHR LINE STORES. DEFERRAL REQUESTED FOR BATTERY REPLACEMENT. STICKER APPLIED AND PLACARDS BLANKED OFSDR CALA2024121301498Anti-Skid Sys · faultedANTISKID ADVISORY A FAULT IS DETECTED IN THE ANTISKID SYSTEM. A/S FAULT ON CLMB OUT SF FAULT RETURNED ON SHORT FINAL IAD. ALL FAULTS WERE INACTIVE WHEN AC LANDED, NO RECENT HISTORY, OUT OF PRECAUTION REPLACED RIGHT BSCU. ALL TESTS PASSED OK, CANNOT GET AC TOSDR CALA2024022100491Rib · crackedVISUAL INSPECTION OF AREA AROUND #7 SLAT ROTARY ACTUATOR FOUND 2 CRACKS. UPPER CRACK APPROX 1 ", LOWER CRACK APPROX 1.5". LEADING EDGE SUPPORT STRUCTURE PIECE PNR 166Z1580-9504-1. LOCKED FOR MAINT FERRY PURPOSES. INSPECTED STEPS 1 THRU 4A AND 5 THRU 7 OF AVO11SDR CALA2023061901937Light · unknownG4 GALLEY L/H FWD EMERGENCY LT CRACKED - ORIGINATED BY EMP V9053 73 ON HAECO NR 9460212, EA 3351-01372 REV B OP014. PERFORMED BY EMP V905373, IDT BY V903665, G4 GALLEY L/H FWD EMER GENCY LT REPLACED PERFORMED INSTALLATION TEST FOUND RESULT NORMA L, AS PER AMM SDR CALA2023061901936Light · unknownOFCR R/H AFT(LAV B OPPOSITE WALL) EMERGENCY LT DAMAGED REF HAECO NON-ROUTINE NO:9460210 - ORIGINATED BY EMP V90537,EA 3351-01372 REV B OP 016. PERFORMED BY EMP V905373,OFCR R/H AFT(LAV B OPPOSITE WALL) EMERG ENCY LT REPLACED PERFORMED INSTALLATION TEST FOUND RSDR CALA2023061901935Light · unknownG4 GALLEY R/H AFT EMERGENCY LT DAMAGED REF HAECO NON-ROUTINE NO: 9460211 - ORIGINATED BY EMP V905373,EA 3351-01372 REV B OP 014. PERFORMED BY EMP V905373,G4 GALLEY R/H AFT EMERGENCY LT REPLACED PERFORMED INSTALLATION TEST FOUND RESULT NORMAL AS PER AMM 33-51 -SDR CALA2023061901934Light · unknownG9 GALLEY AFT EMERGENCY LT CRACKED REF HAECO NON-ROUTINE NO: 9460213 - ORIGINATED BY EMP V9460213,EA 3351-01372 REV B OP 014. PERFORMED BY EMP V905373,G9 GALLEY L/H AFT EMERGENCY LT REPLACED PERFOMRED INSTALLATION TEST FOUND RESULT NORMAL AS PER AMM 33-51 -06-SDR CALA2023061901933Light · unknownDURING PERFOMRED EMERGENCY LIGHTS TEST FOUND 49F SEAT EMERGENCY LT INOP REF HAECO NON-ROUTINE NO:9461083 - ORIGINATED BY EMP V90 5373, SPEC NO.B787-33-3-0001. PERFORMED BY EMP V905373,49F SEAT EMERGENCY LT REPLACED PERFORME D INSTALLATION TEST FOUND RESULT NORSDR CALA2023061901932Light · unknownSEAT 33F EMERGENCY LIGHT DIM - ORIGINATED BY EMP V905373 ON HAEC O NR 9460197, EA 3351-01372 REV B OP015. PERFORMED BY EMP V905373, IDT BY903665, SEAT 33F EMERGENCY LT RE PLACED, PERFORMED INSTALLATION TEST FOUND RESULT NORMAL, AS PER AMM 33-51-06-00A-520A/720SDR CALA2022062701592None · faultyTHIS IS A SUPPLEMENTAL REPORT FOR THE SAME CONTROL NUMBER SUBMITTED ON 6/27/22. CREW. REPORTED ODD NOISE DURING BOARDING IN FORWARD RIGHT GALLEY BUT NOTHING SIGNIFICANT.FOUND FWD E&E EXHAUST FAN RUNS BUT VIBRATES
EXCESSIVELY AND IS NOISY.CREW REPORTED IT SO SDR CALA2021100101760None · smokeSMOKE IN CABIN AND COCKPIT AT GATE WITH APU AND PACKS RUNNING CHKD CMCF NO STATUS MSG,FIM TASK SOUND, MEL 2152AW TO BE APPLIED REQUEST TOMC APPROVAL.DDP SMOKE IN CABIN AND COCKPIT AT GATE WITH APU AND PACKS DMC-B787-A-21-20-F5-72A-421A-A,ISSUE 065 DATED 17 JUNSDR CALA2021090801531Control Unit · failedAHM DETECTED WELS MMSG {33-11727}CLASS 27 - DOOR 3 LH AFT SEAT REMOTE WCU LAMP DRIVER POWER CIRCUIT IS FAILED REF TO REPLACE WCU. M3351WG01 (CLASS27) @ SEAT 31D.CLASS NO.27 WCU REPLACED AND PERFORMED WCU ONBOARD DATA LOADING FOUND NORMAL. THEN PERFORMED WCU INSDR CALA2020092601142Battery · failedPED 3LT AFT REMOTE WELS CONTROL UNIT BATTERY POWER FAILED (MSG:3 3-11414), REFER NON-ROUTINE NR 9416016. REPLACED CLASS 14 WELS CONTROL UNIT BATTERY AND PERFORMED INSTALLATION TEST FOUND NORMAL. THE FAULT MESSAGE FOUND CLEARED, REFER AMM 33-51-07-02B-520A-ASDR CALA2020092601141Battery · faultedPED DOOR 3 RT FWD NR 15 REMOTE WELS CONTROL UNIT POWER BATTERY FAILED, REFER NON-ROUTINE NR 9416026. REPLACED CLASS 15 WELS CONTROL UNIT BATTERY AND PERFORMED INSTALLATION TEST FOUND NORMAL. THE FAULT MESSAGE FOUND CLEARED, REFER AMM 33-51-07-02B-520A-A & SDR CALA2020092601140Battery · failedPED DOOR 2 LT FWD REMOTE WELS CONTROL UNIT POWER BATTERY FAILED (MSG:33-11411), REFER NON-ROUTINE NR. 9416028. REPLACED L2 DOOR CLASS 11 AND R2 DOOR CLASS 11 WELS CONTROL UNIT BATTERY AND PERFORMED INSTALLATION TEST FOUND NORMAL THE FAULT MESSAGE CLEARED, RESDR CALA2020092601139Battery · faultedDOOR 3R AFT NR 6 WCU BATTERY FAIL, REF NON-ROUTINE NR 9416707. REINSTALLED CLASS 6 WELS CONTROL UNIT BATTERY AND RESET THE ECB THEN CARRIED OUT INSTALLATION TEST FOUND NORMAL. THE FAULT MESSAGE FOUND CLEARED, REF AMM 33-51-07-02B-520A-A & AMM 33-51-07-02B-SDR CALA2020092601138Lamp · damagedMAIN CABIN GALLEY NR 5 LT FWD FLOOR PROXIMITY EMERGENCY LIGHT ASSY FOUND DAMAGE (P/N:0204666-101), REF NON-ROUTINE NR 9416638. REPLACED GALLEY NR 5 LT FWD FLOOR PROXIMITY EMERGENCY LIGHT ASSY AND TEST FOUND PASS, AS PER AMM B787-A-33-51-06-00A-520-A REV.140 SDR CALA2020092601137Battery · failedPED DOOR 1 RT NR 2 REMOVE WELS CONTROL UNIT BATTERY FAILED (MSG: 33-11402), REF NON-ROUTINE NR 9416031. PERFORMED SCHEDULED PART CHANGED THEN CARRIED OUT INSTALLATION TEST FOUND NORMAL AND FAULT MSG FOUND CLEARED, REF AMM 33-51-07-02B-520A-A & AMM 33-51-07-0SDR CALA2020092601136Lamp · damagedMAIN CABIN GALLEY NR 9 FLOOR PROXIMITY EMERGENCY LIGHT ASSY FOUND DAMAGE (P/N:0204666-101), REF NON-ROUTINE NR 9416636. ORIGINATED BY EMP V903217, SPEC NR B787-33-3-0001. PERFORMED BY EMP V903179. REPLACED THE GALLEY NR 9 FLOOR PROXIMITY EMERGENCY LIGHT ASSSDR CALA2020092601135Lamp · damagedMAIN CABIN GALLEY NR 1 FLOOR PROXIMITY EMERGENCY LIGHT ASSY FOUND DAMAGE (P/N:0204666-101), REF NON-ROUTINE NR 9416637. ORIGINATED BY EMP V903217, SPEC NR B787-33-3-0001. PERFORMED BY EMP V903217. REPLACED THE GALLEY NR 1 FLOOR PROXIMITY EMERGENCY LIGHT ASSSDR CALA2020092501134Lamp · damagedMAIN CABIN GALLEY NR 5 RT FWD FLOOR PROXIMITY EMERGENCY LIGHT ASSY FOUND DAMAGE (P/N: 0204666-101), REF NON-ROUTINE NR 9416639. ORIGINATED BY EMP V903217,SEPC NO.B787-33-3-0001. PERFORMED BY EMP V903179. REPLACED GALLEY NR 5 RT FWD FLOOR PROXIMITY EMERGENCYSDR CALA2020011900191Transceiver · inoperativeWEATHER RADAR SYS R WXR FUNCTIONS WITHIN THE RIGHT SIDE COMPONENTS ARE FAILED OR PARTIALLY FAILED. FIM TASK REF : 34-40-F2-C1A-421A-A CMC MSG 3460122 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: RIGHT INTEG SURVEILLANCE SYSTEM PROC UNIT CMC MSSDR CALA2019032200439Structure · damagedRIGH WING LEADING EDGE DAMGE AFTER AIRCRAFT WING COLLIDED WITH HANGAR APPROX WSTA 1200 ACP''D DVI PER AVO7477 REV ''B'', STEP 7. CREATED NON-ROUTINE WRITE UPS FOR DEFECTS AND DAMAGES. REFERENCE UNITED ECRA 5730-03480, BOEING REPAIR ORDER UAL-RE-190 1888 RH RAKSDR CALA2019030100338Transceiver · failedWEATHER RADAR SYS R WXR FUNCTIONS WITHIN THE RIGHT SIDE COMPONENTS ARE FAILED OR PAR TIALLY FAILED. EXISTING FAULTS SHOWS WXR RADAR SYS R, DUE TO HISTORY, LEFT AND RIGHT SYSTEM FAULT SUSPECT ANTENNA DRIVE UNIT PER IPD 34-42-03-050-941A. INBOUND MSG 34-60122. RSDR CALA2018021800681Battery · failedSEAT REMOTE CONTROL UNIT, BATTERY POWER FAILED. THE BATTERY WAS REPLACED, PERFORMED A SYSTEM CONFIGURATION AND RELOADED SOFTWARE, OPS CHECKED GOOD,SDR CALA2018012000254Battery · inoperativeMAIN AISLE OVERHEAD EMERGENCY LIGHTS ROWS 17, AND 35 INOPERATIVE. REPLACED THE CONTROL UNIT BATTERY AND TESTED OK IAW 33-51-07-01 A-520.SDR CALA2018011200149Battery Pack · inoperativeOVERHEAD AISLE EMERGENCY LIGHTS INOPERATIVE AT SEAT ROW 3. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 33-51-07-02B, TESTED OK.SDR CALA2018011200118Battery Pack · failedEMERGENCY LIGHTS IN BOTH SECTIONS OF BUSSINESS CLASS ARE INOPERATIVE. FOUND BATTERY PACKS AT THE WCU 21.1, 23.2 AND 24.1 FAILED. REPLACED THE BATTERIES IAW AMM 33-51-07-02B. ALL SEAT MOUNTED EMERGENCY LIGHTS NOW OPERATE NORMAL.
Back to N38950