N407YX

Service difficulty reports · 41

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N407YX' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR R61A2026013100032Engine · failedNR 2 ENG FAILED EICAS DURING CLIMBOUT. PLANE PHYSICALLY VIBRATED. AMBER VIBRATION LOW PRESSURE INDICATION N1 DROPPED TO APPROX 18%. ITT WAS AROUND 770 DEGREES. ENGINE ATTEMPTED TO AUTO RELIGHT. UNSUCCESSFUL. SHUT THE ENGINE DOWN IAW QRH. DECLARED EMERGENCY, Jan 31, 2026 · N407YX · Emb ERJ170200LR · Engine (Turbine/Turboprop)SDR R61A2024080900346Finger Doubler · corrodedFORWARD CARGO DOOR CUTOUT AFT FINGER PLATE IS CORRODED FR 26-27. REMOVED AND REPLACED FWD CARGO DOOR CUTOUT, AFT FINGER DOUBLER REF. SRM 51-40-08.Jul 27, 2024 · N407YX · Emb ERJ170100LR · Fuselage Main, Plate/SkinSDR R61A2022111400701Battery Pack · inoperativeEMERGENCY LIGHT IN CABIN #5 IN CEILING IS INOP. R&R AFT INBOARD EMERGENCY BATTERY POWER UNIT IAW AMM 33-50-01.Nov 9, 2022 · N407YX · Emb ERJ170200LR · Emergency LightingSDR R61A2022071700448Rib · crackedRH HORIZONTAL STABILIZER RIB 14 IS CRACKED ON UPPER FLANGE. REMOVED AND REPLACED RIB 14 ON R/H HORIZONTAL STABILIZER. REF EMB SRM 51-40-08.Jul 15, 2022 · N407YX · Emb ERJ170200LR · Horizontal Stabilizer, Spar/RibSDR R61A202101150052Light · inoperativePHOTOLUMINESCENT STRIP IN FRONT OF WARDROBE WILL NOT REMAIN ILLUMINATED. R & R PHOTOLUMINESCENT STRIP IN FRONT OF WARDROBE, IAW AMM 33-50-21.Jan 13, 2021 · N407YX · Emb ERJ170200LR · Emergency LightingSDR R61A202001040013Floorbeam · corrodedAFT LAV WET AREA HAS CORROSION ON L/H FLOOR BEAM AT FR87 AS MARKED. BLENDED EFFECT AREA AND FOUND OUT OF LIMITS, FABRICATED REPAIR DOUBLER ON BEAM PN: 170-65669-003 REF MB SRM 53-23-10 AND INSTALLED REF EMB SRM 53-23-10, RESTORE SURFACE REF EMB SRM 51-23-06Dec 18, 2019 · N407YX · Emb ERJ170200LR · Fuselage Main, Floor BeamSDR R61A202001040012Door · corrodedCORRODED WASTE SERVICE DOOR 152AR REMOVED AND REPLACED WASTE SERVICE DOOR PANEL 152AR PN: 170-86668-403 REF EMB SRM 53-03-60 AND RESTORE SURFACE REF EMB SRM 51-23-04, 51-23-05 & 51-23-06.Dec 18, 2019 · N407YX · Emb ERJ170200LR · Fluid Service DoorsSDR R61A202001040010Angle · corrodedLITE CORROSION ON 3 EA LOWER ANGLES AND 2 EA CRACK RECEPTACLE ON PANEL 1431DL. REMOVED COROSION ON 1431DL LOWER AFT 2 ANGLES BY BLENDING . MATERIAL LOSS .004. OUT OF LIMITS PER SRM 51-75-16 COMPLETELY DRILLED AND INSTALLED (2) NEW ANGLES ON PANEL 1431DL REF EMDec 18, 2019 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001040011Flange · corrodedAFT WTF AFT ATTACH FLANGE HAS CORROSION BETWEEN FR 73-74 AND STGR 26R AS MARKED REMOVED AND REPLACED AFT WTF ATTACH FLANGE PN: 170-92409-003 REF EMB SRM 51-40-08 , RESTORE FINISH REF EMB SRM 51-23-06.Dec 17, 2019 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001040009Angle · corrodedCORROSION ON 3 EA LOWER ANGLE AND 2 EA CRACK RECEPTACLE ON PANEL 1441FR. REMOVED AND REPLACED LOWER 3 EA ANGLES PN: 170-10063-004, 170-10065-002 & 170-10064-002. REF EMB SRM 51-40-02 & 51-40-08.Dec 16, 2019 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001040008Shear Tie · corrodedCORROSION ON SHEAR CLIP FR 88 STRINGERS 27R-28R REMOVED AND REPLACED SHEAR CLIP PN: 170-66531-001 REF EMB SRM 51-40-08.Dec 15, 2019 · N407YX · Emb ERJ170200LR · Fuselage Internal Mounting StructureSDR R61A202001040007Door Sill · corrodedFWD R/H SILL FR 12 - FR 14 HAS MULTIPLE AREAS OF CORROSION AS MARKED REMOVED AND REPLACED FWD RH SILL PN: 170-05663-003 REF EMB SRM 51-40-08, RESTORE FINISH REF EMB SRM 51-23-04, 51-23-05 & 51-23-06.Dec 14, 2019 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201909160979Shutoff Valve · failedSUPPLEMENTAL INFORMATION: BLEED 1 FAIL IN FLIGHT, FOLLOWED QRH, RETURNED TO FIELD, DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R E1 NAPRSOV IAW AMM 36-11-03.Sep 16, 2019 · N407YX · Emb ERJ170200LR · Pneumatic Distribution SystemSDR R61A201804030457Slide · partial deployL1 DOOR SLIDE GIRT BAR JAMMED ON DOOR OPENING. FOUND THE DOOR SLIDE PARTIALLY DEPLOYED. R & R THE SLIDE ASSY IAW AMM 25-65-01. R & R THE DOOR PNEUMATIC ASSY DIAPHRAGM AND SHEAR PIN IAW AMM 52-11-53. OPS CHECKED GOOD.Apr 3, 2018 · N407YX · Emb ERJ170200LR · Escape SlideSDR R61A201802020121Light · damagedFWD RT EMERGENCY LIGHT DAMAGED. R & R THE EMERGENCY LIGHT IAW AMM 33-50-21.Feb 2, 2018 · N407YX · Emb ERJ170200LR · Emergency LightingSDR R61A201801270089Gusset · corrodedWHILE IN HEAVY CHECK, FWD WET AREA RT SIDE UNDER GALLEY RT SILL PLATE FROM FR 12 - FR 14 IS CORRODED. REMOVED AND REPLACED.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201801270088Angle · corrodedWHILE IN HEAVY CHECK, FOUND CORROSION ON BOTH LOWER ANGLES ON PANEL 1441FR. REPLACED.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201801270087Angle · corrodedWHILE IN HEAVY CHECK, FOUND SURFACE CORROSION ON BOTH LOWER ANGLES ON BODY W/W PANEL 1431DL. REPLACED ANGLES.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201801270086Panel Support · corrodedWHILE IN HEAVY CHECK, FOUND CORROSION ON RT PANEL SUPPORT FRAME 89. REPLACED FLOOR PANEL SUPPORT PN 170-86181-005.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201801270085Shear Panel · corrodedWHILE IN HEAVY CHECK, CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RT SHEAR PLATE. REMOVED ANT REPLACE SHEAR PANEL AFT WET AREA.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201801270084Shear Panel · corrodedWHILE IN HEAVY CHECK, CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 CENTER SHEAR PANEL. REMOVED AND REPLACED CENTER SHEAR PANEL IN THE AFT WET AREA REF SRM.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201801270083Gusset · corrodedWHILE IN HEAVY CHECK, CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RT CENTER GUSSET FRAME 90 AS MARKED. REMOVED AND REPLACED RT CENTER GUSSET AT FR 90REF SRM 51-23-06 AND 51-41-02.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201801270082Gusset · corrodedWHILE IN HEAVY CHECK, CORROSION RT GUSSET PLATE FRAME 90. REMOVED AND REPLACED GUSSET PN: 170-60259-001 REF SRM 51-40-08.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201801270081Splice · corrodedWHILE IN HVY CHECK, CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RT CENTER SPLICE. FRAME 90 AS MARKED. REMOVED AND REPLACED CENTER SPLICE PN: 170-86119-005.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A2018012700800Skin · corrodedWHILE IN HEAVY MX CHECK, SURFACE CORROSION ON EXTERNAL SKIN BETWEEN FRAME 22 AND 23 AT STRINGER 28L. COMPLIED WITH ETD2018-170-006905-A PERMANENT REPAIR OF SURFACE CORROSION AT FR23-24 AND STR 28L.Jan 27, 2018 · N407YX · Emb ERJ170200LR · Fuselage Main, Plate/SkinSDR R61A201802010117Seat Track · corrodedRIGHT INBD SEAT TRACK GOUGED AND CORRODED, FRAMES 23 - 34. REMOVED AND REPLACED THE SEAT TRACK IAW SRM 51-40-08, 51-40-02, 51-23-04, 51-23-06, AND CPM 51-25-00.Jan 18, 2018 · N407YX · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR R61A201802010116Beam · corrodedCORRODED BEAM Y=10.748. REMOVED, FABRICATED, LOCATED, DRILLED, AND INSTALLED A NEW BEAM FR 88 IAW SRM 53-23-10R01, AND 51-40-02.Jan 16, 2018 · N407YX · Emb ERJ170200LR · Fuselage Main, StructureSDR R61A201802010115Seal Rest · corrodedCORROSION AT THE FWD CARGO ON THE FWD CORNER SEAL REST, REMOVED AND REPLACED SEAL REST IAW AMM 20-10-01.Jan 16, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201802010114Seal Rest · corrodedCORROSION AT THE FWD CARGO ALONG THE LOWER SEAL REST. REMOVED AND REPLACED SEAL REST IAW SRM 51-40-08, AND 51-40-02.Jan 16, 2018 · N407YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201802010118Skin · gougedTWO GOUGES ON THE EXTERNAL SKIN BETWEEN FRAMES 21 AND 22, STRINGER 27L - 28L REMOVED THE GOUGES AND PERFORMED DOUBLER REPAIR ON THE SKIN IAW SRM 53-10-01/AD01, AND 53-10-01,REPAIR 12P.Jan 15, 2018 · N407YX · Emb ERJ170200LR · Fuselage Main, Plate/SkinSDR R61A201611040635Battery Pack · inoperativeCREW REPORTED THAT THE SECONED EMERGENCY LIGHT IN FIRST CLASS WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED NR 2 EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.Nov 4, 2016 · N407YX · Emb ERJ170200LR · Emergency LightingSDR R61A201610250611Connector · disconnectedCREW REPORTED THAT THE FORWARD CABIN EMERGENCY LIGHTING WAS INOPERATIVE. MAINTENACE FOUND CONNECTOR OFF AT ASSY AND REINSTALLED PER EMB AMM AND OPS CHECKED GOOD.Oct 25, 2016 · N407YX · Emb ERJ170200LR · Light System WiringSDR R61A201607180416Battery Pack · inoperativeCREW REPORTED THAT THE EMERGENCY LIGHT IN THE COCKPIT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.Jul 18, 2016 · N407YX · Emb ERJ170200LR · Emergency LightingSDR R61A201606210392Battery Pack · dischargedCREW REPORTED THAT THE FORWARD GALLEY EMERGENCY LIGHT WAS INOPERATIVE ACFT WAS FLOWN VIA MAINTEANCE FERRY, WHERE MAINTENANCE R & R NR 2 EMERGENCY BATTERY PACK IAW AMM AND OPS CHECKED GOOD.Jun 21, 2016 · N407YX · Emb ERJ170200LR · Emergency LightingSDR R61A201511230874Power Supply · malfunctionedCREW REPORTED THAT THE FORWARD EMERGENCY LIGHTS WOULD NOT EXENGUISH. MAINTENANCE DISCONNECTED AND RECONNECTED ELPU IAW AMM AND OPS CHECKED GOOD.Nov 23, 2015 · N407YX · Emb ERJ170200LR · Emergency LightingSDR R61A201508040514Light · inoperativeCREW REPORTED THAT THE COCKPIT FLOOR EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE PERFORMED SUCCESSFUL OPS CHECKS OF THE COCKPIT FLOOR EMERGENCY LIGHT.Aug 4, 2015 · N407YX · Emb ERJ170200LR · Emergency LightingSDR R61A201504280470Pump · inoperativeCREW RECEIVED A HYD LOW QTY 1 MESSAGE. CREW DID NOT DECLARE AN EMERGENCY AND DIVERTED, WHERE CREW LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT, R & R ENGINE DRIVEN PUMP IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.Jul 28, 2015 · N407YX · Emb ERJ170200LR · Hydraulic Pump (Electric/Engine), MainSDR R61A201503190178Battery Pack · inoperativeMAINTENANCE REPORTED THAT THE NR 1 CABIN EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE R & R NR 1 CABIN EMERGENCY LIGHT IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.Mar 19, 2015 · N407YX · Emb ERJ170200LR · Emergency LightingSDR R61A201407220910Windshield · failedAT APPROXIMATELY 2000 FT, CAPTAINS WINDSHIELD SHATTERED. CONTROL WAS TRANSFERRED TO F/O, CAPTAIN DECLARED AN EMERGENCY AND EMERGENCY VEHICLES WERE DISPATCHED. CREW LANDED AND TAXIIED TO GATE WITHOUT INCIDENT. MAINTENANCE R & R WINDSHIELD IAW AMM AND OPS CHECKEJul 22, 2014 · N407YX · Emb ERJ170200LR · Flight Compartment WindowsSDR R61A201311111134Mechanism · out of adjustCREW REPORTED R2 DOOR NOT SHOWING GREEN WHEN DOOR IS CLOSED. MAINTENANCE INSPECTED AND ADJUSTED R2 DOOR INDICATOR MECHANISM IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.Nov 11, 2013 · N407YX · Emb ERJ170200LR · Passenger/Crew DoorsSDR R61A201310050969Proximity Sensor · defectiveAT APPROXIMATELY 12000 FT, CREW RECEIVED LANDING GEAR WOW SYS FAIL MESSAGE FOR ABOUT 4 SECONDS. MESSAGE WENT AWAY AND CREW BELIEVED IT TO BE AN ERRONEOUS MESSAGE. CAPTAIN LOOKED AT MFD AND NOTICED THAT ON THE STATUS PAGE THE L1, R1 AND FWD CARGO BIN DOOR SATUOct 5, 2013 · N407YX · Emb ERJ170200LR · Landing Gear Position and Warning
Back to N407YX