N409YX

Service difficulty reports · 33

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N409YX' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR R61A2025090200385Engine · failedENGINE 2 FAIL AND LOUD BANG ON TAKEOFF AROUND 1500 FEET. WINDMILLING AND NO OIL PRESSURE, SLIGHT ODOR IN CABIN. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R E2.Sep 2, 2025 · N409YX · Emb ERJ170200LR · Engine (Turbine/Turboprop)SDR R61A2024112300554Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE FOUND AFT CABIN FLOOR STRUCTURE CROSSBEAM AT FR 84 CENTER HAS A TOOLING SCRATCH ON THE UPPER SURFACE. COMPLIED WITH ETD2024-170-029899 REV B BY CUTTING OUT DAMAGED AREA AND INSTALLING A ''L" ANGLE REPAIR DOUBLER TO AFT CABIN FLOONov 3, 2024 · N409YX · Emb ERJ170200LR · Fuselage Main, Floor BeamSDR R61A2024031800120Power Supply · inoperativeL1 EMERGENCY LIGHT POWER UNIT INOP. R&R L1 EMERGENCY LIGHT POWER UNIT.Mar 18, 2024 · N409YX · Emb ERJ170100LR · Emergency LightingSDR R61A2022083100533Stringer · corrodedWHILE IN HEAVY CHECK - STGR 21R INTERNAL SIDE HAS CORROSION AS MARKED FR 83-84. REMOVED DAMAGED SECTION STGR 21R FR81/86 AND REPAIRED WITH FILLER SECTION AND SPLICES BETWEEN FR81 AND FR 86 REF. ETD2022-170-025869.Aug 31, 2022 · N409YX · Emb ERJ170200LR · Fuselage Main, Longeron/StringerSDR R61A2022083100532Stringer · corrodedWHILE IN HEAVY CHECK - STGR 20R INTERNAL SIDE HAS CORROSION AS MARKED FR 83-84. REMOVED AND REPLACED STRINGER 20R FROM FRAME 80 TO FRAME 89 REF SRM 51-40-02.Aug 31, 2022 · N409YX · Emb ERJ170200LR · Fuselage Main, Longeron/StringerSDR R61A2022083100531Stringer · corrodedWHILE IN HEAVY CHECK - STGR 19R INTERNAL SIDE HAS CORROSION AS MARKED FR 83-84. REMOVED DAMAGED SECTION OF STRINGER 19R FR 83/84. INSTALLED. REPAIR FILLER SECTION AND SPLICES FR 83/84 REF ETD2022-170-025853Aug 31, 2022 · N409YX · Emb ERJ170200LR · Fuselage Main, Longeron/StringerSDR R61A2022083100530Stringer · corrodedWHILE IN HEAVY CHECK - STGR 19L INTERNAL SIDE HAS CORROSION AS MARKED FR 83-84. PERFORMED STRINGER SPLICE REPAIR ON STRINGER 19L BETWEEN FR 82/83 TO FR 86/87. REF EMB ETD2022-170-025842.Aug 31, 2022 · N409YX · Emb ERJ170200LR · Fuselage Main, Longeron/StringerSDR R61A2022050600327Panel · dentedMULTI DENTS FOUND BELOW CAPTS DV WINDOW. REPAIRED IAW ETD2022-170-016305.May 2, 2022 · N409YX · Emb ERJ170100LR · Fuselage Miscellaneous StructureSDR R61A2022050600329Strip · inoperativeAIRCRAFT LEFT AISLE ILLUMINATION STRIPS DON'T WORK EVEN WHEN CHARGED VIA BRIGHT CABIN LIGHT. R&R PHOTOLUMINESCENT STRIPS ON LEFT AISLE NEAR FIRST CLASS AND RH AISLE NEAR FIRST CLASS.Apr 1, 2022 · N409YX · Emb ERJ170200LR · Emergency LightingSDR R61A2021071600568Strip · inoperativeFLOOR STRIP LUMINESCENT STRIPS ARE INOP ON LEFT SIDE NEXT TO SEAT 21-22. RESECURED FLOOR G2 PHOTOLUMINESCENT STRIPS AT 21-22 IAW AMM 33-50-21.Jul 13, 2021 · N409YX · Emb ERJ170200LR · Emergency LightingSDR R61A2020021090164Spar · damagedWHILE IN HEAVY CHECK - UPON SKIN OPEN UP ON LH HORIZONTAL, FOUND DIMPLED AREA BESIDE FASTENER HOLE ON SPAR I BETWEEN RIB 9A-10A. PERFORMED PERMANENT REPAIR BY REAMING FASTENER HOLE TO REMOVE DAMAGE AND FABRICATION OF BUSHING REPAIR ON LH HORIZONTAL, SPAR IFeb 9, 2020 · N409YX · Emb ERJ170200LR · Horizontal Stabilizer, Spar/RibSDR R61A2020021090163Seat Track · corrodedWHILE IN HEAVY CHECK- CORROSION ALONG TOP SIDE OF L/H I/B SEAT TRACK BETWEEN FR. 16 TO FR. 20 AS MARKED.REPLACE SEAT TRACK WITH NEW AND APPLY SURFACE PROTECTION.Feb 9, 2020 · N409YX · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR R61A2019081650845Power Supply · faultedEMERGENCY LIGHTS NUMBER 1 AND 3 NOT ILLUMINATING. R&R FWD LH EMERGENCY LIGHTS POWER UNIT IAW AMM 33-50-01.Aug 15, 2019 · N409YX · Emb ERJ170200LR · Emergency LightingSDR R61A201806230733Light · missingEMERGENCY EXIT PATHWAY PHOTOLUMINESCENT STRIP MISSING AT SEAT 20D. R&R STRIP LIGHT AT SEAT 20D IAW AMM 33-50-21.Jun 23, 2018 · N409YX · Emb ERJ170200LR · Emergency LightingSDR R61A201803150319Warning Message · false activationDURING CRUISE, CAS MESSAGE FOR SLAT FAIL. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. CLEARED INHIBITS AND OPERATED FLAP/SLATS IAW AMM 27-80-00. OPS CHECKED OK.Mar 15, 2018 · N409YX · Emb ERJ170200LR · Leading Edge Slat Control SystemSDR R61A201802250271Seal Rest · corrodedCORROSION WAS FOUND AT THE FORWARD CARGO DOOR CUTOUT LOWER FWD CORNER SEAL REST. MAINTENANCE REMOVED AND REPLACED FWD CARGO DOOR CUTOUT LOWER FWD CORNER SEAL REST IAW SRM 51-40-08 AND 51-40-03.Feb 25, 2018 · N409YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201802200270Seal Rest · corrodedCORROSION WAS FOUND AT THE FORWARD CARGO DOOR CUTOUT LOWER AFT CORNER SEAL REST. MAINTENANCE REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER AFT CORNER SEAL REST IAW SRM 51-40-02, AND AMM 20-10-01.Feb 20, 2018 · N409YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201802200269Seal Rest · corrodedCORROSION WAS FOUND AT THE FORWARD CARGO DOOR CUTOUT LOWER CENTER SEAL REST. MAINTENANCE REMOVED AND REPLACED FWD LOWER CENTER SEAL REST IAW SRM 51-41-01.Feb 20, 2018 · N409YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201802190268Cover Plate · corrodedCORROSION WAS FOUND AT THE FORWARD CARGO DOOR CUTOUT COVER PLATE. MAINTENANCE REMOVED AND REPLACED FWD CUTOUT PLATE IAW SRM 20-10-01.Feb 19, 2018 · N409YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201802150267Flap Track · corrodedRIGHT OTBD FLAP, INBD CARRIAGE UPPER TRACK COATING IS COMING OFF AND HAS CORROSION. MAINTENANCE REMOVED AND REPLACED THE FLAP TRACK IAW AMM 57-57-33.Feb 15, 2018 · N409YX · Emb ERJ170200LR · Trailing Edge FlapsSDR R61A201802260234Gusset · corrodedWHILE OUT OF SERVICE, MAINTENANCE DISCOVERED AFT WET AREA GUSSET AT FRAME 90, RBL 12 IS CORRODED. MAINTENANCE REMOVED AND REPLACED THE GUSSET IAW SRM 51-41-02.Feb 15, 2018 · N409YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201802260233Shear Panel · corrodedWHILE OUT OF SERVICE, MAINTENANCE DISCOVERED THE AFT WET AREA SHEAR PANEL AT FRAMES 87 - 88 HAS CORROSION AROUND GALLEY MOUNT HOLES. MAINTENANCE REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-43-01, 51-42-02, AND 51-42-01.Feb 15, 2018 · N409YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201802260232Shear Panel · corrodedWHILE THE ACFT WAS OUT OF SERVICE, MAINTENANCE DISCOVERED THE AFT WET AREA CENTER SHEAR PANEL, FRAMES 87 - 88 CORRODED AROUND THE LAVATORY AND GALLEY MOUNT HOLES. MAINTENANCE REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-42-01.Feb 15, 2018 · N409YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201802130272Skin · dentedMAINTENANCE FOUND A DENT IN THE RT FUSELAGE SKIN BETWEEN FRAMES 7 & 8, STRINGERS 15 & 16R FWD OF LOGO LIGHT BELOW FIRST OFFICER WINDOW. REPAIRED IAW ETD2017-170-026849, REV C.Feb 13, 2018 · N409YX · Emb ERJ170200LR · Fuselage Main, Plate/SkinSDR R61A201707050479Diaphragm · leakingFWD PAX DOOR PNEUMATIC ASSEMBLY AT 0 PSI. R & R PAX ENTRY DOOR PNEUMATIC ASSEMBLY DIAPHRAGM IAW AMM 52-11-53. SERVICED TO 2200 PSI IAW AMM 52-11-51.Jul 5, 2017 · N409YX · Emb ERJ170200LR · Passenger/Crew DoorsSDR R61A201611250689Glowstrip · wornCREW REPORTED THAT THE PHOTO LUMINESCENT STRIPS IN THE FORWARD CABIN WERE WORN AND NO LONGER GLOW. MAINTENANCE REMOVED AND REPLACED PHOTO LUMINESCENT STRIPS PER AMM AND OPS CHECKED GOOD.Nov 25, 2016 · N409YX · Emb ERJ170200LR · Emergency EquipmentSDR R61A201609170550Battery Pack · dischargedCREW REPORTED THAT THE 4TH CABIN EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE R & R EMERGENCY BATTERY PACK NR 4 IAW AMM AND OPS CHECKED GOOD.Sep 17, 2016 · N409YX · Emb ERJ170200LR · Emergency LightingSDR R61A201507030398Glowstrip · looseCREW REPORTED THAT THE PHOTOLUMINESCENT STRIP NEAR THE CLOSET WAS PEELING. MAINTENANCE RESECURED PHOTOLUMINESCENT STRIP IAW AMM AND OPS CHECKED GOOD.Jul 3, 2015 · N409YX · Emb ERJ170200LR · Emergency EquipmentSDR R61A201410041090Flashlight · inoperativeCREW REPORTED THAT THE CAPTAIN`S FLASHLIGHT WAS INOPERATIVE. MAINTENANCE R & R CAPTAIN`S FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.Oct 4, 2014 · N409YX · Emb ERJ170200LR · Emergency EquipmentSDR R61A201404060501Unknown · odorF/A REPORTED AN ELECTRICAL ODOR COMING FROM THE AFT GALLEY WITH NO SMOKE OR FIRE VISIBLE. SHUTOFF COFFEEMAKERS WITH NO EFFECT. DECLARED AN EMERGENCY AND DIVERTED. LANDED WITHOUT INCIDENT. AFT GALLEY WAS INSPECTED AND CREW RAN ENGINES AND NO ODOR WAS NOTED. Apr 6, 2014 · N409YX · Emb ERJ170200LR · Air Distribution SystemSDR R61A201403260447Flashlight · inoperativeCREW REPORTED THAT THE CAPTAINS FLASHLIGHT WAS INOPERATIVE. MAINTENANCE OPS CHECKED FLASHLIGHT GOOD IAW AMM.Mar 26, 2014 · N409YX · Emb ERJ170200LR · Emergency EquipmentSDR R61A201312161322Flashlight · inoperativeDURING PREFLIGHT CHECK THE AFT F/A FLASHLIGHT WAS FOUND TO BE INOPERATIVE. THE FLASHLIGHT WAS R & R IAW AMM 33-51-01.Dec 16, 2013 · N409YX · Emb ERJ170200LR · Emergency EquipmentSDR R61A201310221054Indicator · out of adjustCREW REPORTED THAT THE L2 DOOR ARM/DISARM INDICATOR WAS NOT FULLY INDICATING. MAINTENANCE INSPECTED AND FOUND ARM/DISARM INDICATOR FULLY FUNCTIONAL, BUT THE LATCH INDICATOR ON DOOR FRAME NOT FULLY INDICATING.Oct 22, 2013 · N409YX · Emb ERJ170200LR · Door Warning System
Back to N409YX