N420DX
Service difficulty reports · 111
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N420DX' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N420DX' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2025011300295Bottle · low pressureSHIP 3420 3R DOOR ASSIST BOTTLE LOW. CORRECTIVE ACTION: SERVICED 3R DOOR BOTTLE IAW A330 AMM 52-10. OK FOR SVC. (6437605)SDR DALA2024110410613Bottle · leakingSHIP 3420 R2 DOOR DAMPER CYLINDER WON'T HOLD CHARGE. LEAKS FROM PLUNGER. CORRECTIVE ACTION: R/R #2R DOOR EMERGENCY DOOR DAMPER ACTUATOR DIAPHRAGM PER COLLINS AEROSPACE CMM 52-11-04. OK FOR SERVICE. (0642913)SDR DALA2024102810478Power Supply · faultySHIP 3420 ASPSU FAILED BITE TEST WITH FAULT ASPSU (101MJ) DOOR 1. CORRECTIVE ACTION: R/R ASPSU PER A330 AMM 52-71. OK FOR SERVICE. (0628222)SDR DALA2024070806866Warning Message · false activationSHIP 3420 - ATB/DE AIRCRAFT PERFORMED AIR TURN BACK TO HND AND CREW DECLARED EMERGENCY DUE TO LIGHTNING STRIKE WITH RIGHT ENGINE STALL MESSAGE. CORRECTIVE ACTION: PER TSM CLEARED FAULTS RAN ENGINE FOR FIVE MINUTES AND NO FAULTS RETURNED. NO FURTHER ACTION REQUSDR DALA2024070806859Power Supply · faultedSHIP 3420 ASPSU FAULTING MESSAGE. CORRECTIVE ACTION: REPLACED ASPSU UNIT PER A330 AMM 52-71. OK FOR SERVICE. (5766439)SDR DALA2024062006264Stop Fitting · brokenSHIP 3420 PSU OXYGEN DOOR TEST STOP ASSEMBLY BROKEN / LOCATION:2J. CORRECTIVE ACTION: ADJUSTED DOOR LATCH CHECKS GOOD. (0402507)SDR DALA2024042204641Printer · failedSHIP 3420 - DIV - INTO KEF DUE TO ELECTRICAL BURNING SMELL IN FLIGHT DECK. CORRECTIVE ACTION: REPLACED ACARS PRINTER. OK FOR SERVICE. (5323135)SDR DALA2024040103965Bottle · low pressureSHIP 3420 FOUND DOOR 3R EMER ASSIST PRESSURE BELOW MIN. CORRECTIVE ACTION: SERVICED PER A330 AMM 52-10. OK FOR SERVICE. (0270927)SDR DALA2023090807367Unknown · unknownSHIP 3420 DAMAGE BETWEEN FR57.4 & FR58 AND STGR40RH & STGR39RH DUE TO STAIR STAND IMPACT. CORRECTIVE ACTION: AREA BLENDED AND EVALUATED IAW A330 NEO SRM 53-41-11. DAMAGE ZONE 1, REPAID CAT C. (4409790)SDR DALA2023090107168Unknown · unknownSHIP 3420 EMERGENCY EXIT SIGNS INOPERATIVE. LOCATIONS 604. CORRECTIVE ACTION: RESECURED LENS. (2946411)SDR DALA2023060604601Unknown · unknownSHIP 3420 SMOKE DETECTOR 4R ACTIVATED DUE TO VAPING. CORRECTIVE ACTION: LAV SMOKE DETECT RESET. NO DEFECTS NOTED. (4853638)