N424YX
Service difficulty reports · 26
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N424YX' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N424YX' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A202509050038Rib · damagedSYS HYD 2 PRESSURE LINE WALL FITTING PASS THROUGH CHAFED AND ELONGATED OTBD OF RIB 4A ON TRAILING EDGE, REPAIRED BY REAMING HOLE AND INSTALLED REPAIR BUSHING. SRM 57-50-05/REPAIR01.SDR R61A2025012000057Unknown · odorELECTRIC FUME SMELL, DID NOT SMELL LIKE OZONE. SMELL WENT AWAY DURING DESCENT, A FA SMELL MOST STRONGLY FWD LAV. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. TROUBLESHOT, NO FAULTS FOUND.SDR R61A2024031100108Skin · dentedAIRCRAFT DAMAGE TO SKIN FROM WORK STAND BETWEEN FRAMES 97-98 AND STRINGERS 28L-29L.INSTALLED FILLER AND DOUBLER IAW ETD2024-170-006591. ALSO REF VP-009049-2024 N/R #3 FOR WORK PERFORMED.SDR R61A2023041100224Skin · damagedONE MISDRILLED HOLE ON REAR FUSELAGE UPPER SKIN AT LH VERTICAL STABILIZER FILLET AREA. PERFORMED PERMANENT REPAIR BY BUSHING REPAIR ON UPPER LH SKIN PANEL BETWEEN FR94-95 OB OF STGR 01L IAW ETD 2023-170-008039.SDR R61A2022120900774Light · inoperativePHOTOLUMINESCENT LIGHTS NOT ILLUMINATING AC RH FWD NEAR SEAT 1D. R&R PHOTOLUMINESCENT STRIP AT 1/2DF.SDR R61A2021120300964Power Unit · inoperativeSUPPLEMENTARY INFORMATION. 2 CEILING EMERGENCY LIGHTS INOP. R&R ELP 1.SDR R61A2021041900343Light · inoperativePHOTOLUMINESCENT STRIPS FROM FWD GALLEY CLOSED TO SEAT 1DF ON RIGHT SIDE OF AISLE NO LONGER ILLUMINATED. STRIPS 1-4 ON AISLE RIGHT. R&R PHOTOLUMINESCENT STRIPS FROM RH CLOSET TO SEAT 1 DF.SDR R61A2020100200679Spar · crackedWHILE IN HEAVY CHECK, CRACK BOTTOM FLANGE ON LT WING TIP SPAR 1 FITTING. REMOVED AND REPLACED LT WING TIP SPAR 1 FITTING, PER SRM 51-40-08.SDR R61A2020012870111Light · inoperative1ST ROW RIGHT SIDE PHOTOLUMINESCENT STRIP LIGHT DAMAGED. R&R 1ST ROW SIDE PHOTOLUMINESCENT STRIP.SDR R61A2019082740864Battery · no testLH FWD LWR EMERGENCY LIGHT INOP ON TEST. R&R FWD RH EMERGENCY LIGHT BATTERY REF AMM 33-50-01.SDR R61A201807290834Closeout Panel · corrodedWHILE IN HEAVY CHECK, CORROSION FWD CARGO THRESHOLD CLOSE OUT PANEL AS MARKED. REMOVED AND REPLACED FWD CARGO CLOSE OUT PANEL REF MM 20-10-01.SDR R61A201807290833Doubler · corrodedWHILE IN HEAVY CHECK, CORROSION ON INNER DOUBLER ON PANEL 192CR. REMOVED AND REPLACED PANEL 192CR INNER DOUBLER REF SRM 51-40-08.SDR R61A201807290832Attach Angle · corrodedWHILE IN HEAVY CHECK, CORROSION ON BOTH BOTTOM ANGLE ON PANEL 1431DL. REMOVED AND REPLACED BOTH BOTTOM ANGLE ON PANEL 1431DL REF SRM 51-40-08.SDR R61A201807290831Seat Track · corrodedWHILE IN HEAVY CHECK, CORROSION- RT I/B SEAT TRACK AT FR84 AS MARKED. COMPLIED WITH PERMANENT REPAIR OF RT SEAT TRACK FR84 REF SRM 53-23-10 REPAIR 04, FABRICATION OF DOUBLER AND FILLER, APPLIED SURFACE PROTECTION REF SRM 51-23-06.SDR R61A201807290830Seat Track · corrodedWHILE IN HEAVY CHECK, CORROSION ON LT I/B SEAT TRACK AT FR84 AS MARKED. COMPLIED WITH PERMANENT REPAIR OF LT SEAT TRACK FR84 REF ETD2018-170-080265, FABRICATION OF DOUBLER, APPLIED SURFACE PROTECTION REF SRM 51-23-06.SDR R61A201807290829Gusset · corrodedWHILE IN HEAVY CHECK, CORROSION ON RT I/B GUSSET AT FR 90 AS MARKED. REMOVED DAMAGE ON RT I/B GUSSET AT FR 90 REF SRM 51-10-03.SDR R61A201807290828Shear Panel · corrodedWHILE IN HEAVY CHECK, CORROSION ON RT SHEAR PANEL FR 87- FR 88 AS MARKED. REMOVED AND REPLACED RT SHEAR PANEL FR87-88 REF SRM 51-40-08.SDR R61A201807290827Support · corrodedWHILE IN HEAVY CHECK, CORROSION ON LT MONUMENT SUPPORT AT FR 19 AS MARKED. REMOVED AND REPLACED LT MONUMENT SUPPORT AT FR19 REF SRM 51-43-03.SDR R61A201807290826Door Sill · corrodedWHILE IN HEAVY CHECK, CORROSION ON RT SILL FR 12-14 AS MARKED. REMOVED AND REPLACED RT SILL FR 12-14 REF SRM 51-40-08.SDR R61A2018052280601Power Supply · inoperativeEMERGENCY LIGHTS NOT TESTING. R & R THE EMERGENCY LIGHT POWER SUPPLIES. 2, 3, AND 4.SDR R61A201607050402Fmc · inoperativeENROUTE, CREW RECEIVED A SPOILER FAULT MESSAGE. DECLARED AN EMERGENCY AND DIVERTED AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED NR FCM IAW AMM AND OPS CHECKED GOOD.SDR R61A201503280200Battery Pack · inoperativeMAINTENANCE REPORTED THAT THE EMERGENCY LIGHT AT ROW 8 WAS INOPERATIVE. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.SDR R61A201503240187Battery Pack · inoperativeCREW REPORTED THAT THE R2 DOOR EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.SDR R61A201503190180Battery Pack · inoperativeCREW REPORTED THAT THE OVERHEAD EMERGENCY LIGHT AT ROW 8 WAS INOPERATIVE. MAINTENANCE R & R THE EMERGENCY LIGHT POWER UNIT IAW AMM AND OPS CHECKED GOOD.SDR R61A201502080078Flashlight · missingCREW REPORTED THAT THE FORWARD F/A FLASHLIGHT WAS MISSING. MAINTENANCE INSTALLED NEW FORWARD F/A FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.SDR R61A201409231071Power Supply · inoperativeMAINTENANCE REPORTED THAT THE COCKPIT EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE R & R EMERGENCY LIGHT POWER UNIT IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.
Back to N424YX