N428UA
Service difficulty reports · 197
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N428UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N428UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010052801846Pump · failedLOST BLUE HYD SYSTEM ON DESCENT. DIVERSION FOR ADDITIONAL RUNWAY LENGTH. REPLACED HP FILTER & BLUE SYS ELECTRIC PUMP. OPS ARE GOOD.SDR UALA2010033001060Slide · faultyEXT LOADS FWD L MESSAGE ON CIDS PANEL AFTER EMERGENCY LIGHT TEST. T/S DETERMINED THAT SLIDE AT 1R IS CAUSING MSG. REPLACED 1R DOOR SLIDE. INSP SLIDE AT DOOR 1R, SLIDE SECURED ON DOOR, SLIDE PIN REMOVED AND STOWED, ASSIST BOTTLE REARMED AND SAFETIED, EMERG LIGHSDR UALA2010011100120Slide · no testFOUND 1 RT MED SLIDE WOULD NOT PASS EMERGENCY LIGHT TEST. REMOVED AND REPLACED NR1 RT MED SLIDE ASSY, EMERGENCY LIGHTS CHK GOOD.SDR UALA2009111603572Thermostat · faultyBLEED AIR LOSS, FLT DIVERTED. RE-ACTIVATED NR 2 ENG PRV AND DE-ACTIVATED HP VALVE. REPLACED NR 1 ENG FAN AIR VALVE CONTROL THERMOSTAT. REPLACED SOLENOID. BLEED CHECK COMPLETED ALL RUNS COMPLETED SATISFACTORY. ACCOMPLISHED HEALTH CHECK FROM PAGE 1 TO 14 ALSDR UALA2009111603558Slide · faultyEMERGENCY LIGHT TEST FAIL TEST, MSG EXT LOAD FWD LEFT, BATTERY FWD LEFT, BATTERY AFT LEFT. REPLACED LEFT FWD EPSU BATTERY PACK AND LEFT AFT EPSU BATTERY PACK AND CLEARED THE BATTERY MSG'S. FOUND SLIDE AT DOOR 1R BAD FOR "EXT LOAD FWD LEFT" FAULT. NEEDS A SLSDR UALA2009100603138Power Supply · failedF-REPORTS EMERGENCY EXIT LIGHTS ON DOOR 1L, EMERGENCY LIGHTS TEST FAILURE MSG WAS "EPSU UNIT FWD L". REPLACED EPSU AT DOOR 1L. EMERGENCY LIGHTS NOW TEST OKAY.SDR UALA2009091602933Sensor · malfunctionedABORTED TAKEOFF AT 100 KTS DUE TO CAPTS AIRSPEED INDICATION. PER POST FLIGHT REPORT, ADM -19 MESSAGE, AOA SENSOR 3FP2, AOA SENSOR 3FP3 DISAGREE. REPLACED CAPT ADM 19PF1 AND REPLACED NR 2 AOA 3PF2. ACP HIGH RANGE LEAK TEST, CHECKS OK. NO SPLIT ON AIRSPEED OSDR UALA2009091402882Slide · faultyWHILE ACCOMPLISHING EMERGENCY LIGHTS TEST ON CIDS GOT MSG- EXT. LOADS FWD L. PERFORMED TEST OF LEFT FWD EPSU AND GOT A FAULT ON EXTERIOR LIGHTS. SUSPECT LT FWD ESCAPE SLIDE. MT33-001 IS HELPFUL FOR TS. ACCOMPLISHED TROUBLESHOOTING AND FOUND BOTH FWD DOOR SLIDESDR UALA2009061801733Slide · faultyEMERGENCY LIGHT TEST FAILS, FAULT "EXT LOADS FWD R". TROUBLESHOOT SYSTEM FOUND DOOR 1R CAUSING EMERGENCY LIGHT FAILURE DURING TEST. REPLACED RT DOOR SLIDE ASSY. INSTALLATION AND OPS CHECKS GOOD, EMERGENCY LIGHT TESTS GOOD.SDR UALA2009051501384Light · inoperativeEMERGENCY LIGHT TEST FAULTING "EXT LOADS FWD L". DOOR 1L SLIDE LIGHTING FAULT ESTABLISHED. ACP EMERGENCY LIGHT TEST. FOUND NO FAULT. OPS CHK NORMAL.SDR UALA2009021100453Slide · faultyCIDS CLASS 1 FAULT FOR ESPU EXT LOAD FWD L MESSAGE AFTER OPERATION TEST OF EMERGENCY LIGHTING SYSTEM. REPLACED 1R FWD SLIDE. SYSTEM CHECKED NORMAL.SDR UALA2009010900087Slide · faultyEMERG LIGHT CK MESSAGE EXT LOADS FWD LT SLIDE LIGHTS INOP. REPLACED DOOR 1L SLIDE. EMERGENCY LIGHT CHECK PASSED.SDR 2008UALA05600Slide · unserviceableEMERGENCY LIGHT TEST FAILED WITH MSG, EXTERNAL LOAD FWD LEFT. REPLACED PSU 10WL AND BATTERY, NO HELP. RE-INSTALLED ORIGINAL. SWAPPED L FWD AND R FWD SLIDES, ALSO NO HELP. RE-INSTALLED ORIGINAL. REPLACED DOOR 1LT SLIDE. CHECKS NORMAL. ALL EMERGENCY TEST SDR 2008UALA02125Line · leakingFLIGHT DIVERTED TO DUE TO YELLOW SYSTEM HYDRAULIC LOSS. PYLON HYD LINE WAS LEAKING AT RIB 5, REPLACED PYLON HYD LINE IN NR 2 PYLON. ALSO -REPLACE NR 1 ENG HYD FILTER DUE TO SYS RUN DRY.SDR 2008UALA02042Wire · shorted3 SVC EMERGENCY LIGHT TEST FAILS. MED 1L SLIDE LIGHT NOT TESTING. FOUND SHORTED WIRE INSIDE ASSY SLIDE AT 1L. REPLACED DOOR SLIDE 1L.SDR 2008UALA01459Fan · malfunctionedDIVERTED DUE TO BURNING-ACRID SMELL IN AFT CABIN. BURNT BEARING IN LT RECIRC FAN. REPLACED LT RECIRC FAN, ALL TESTS WERE NORMAL, NO SMELL NOTED.SDR 2008UALA00510Slide · shortedEMERGENCY LIGHT SYSTEM TEST FAILS WITH CFDS MESSAGE EXT LOAD FWD LEFT. ELECTRICAL SHORT WITHIN FWD LEFT SLIDE ASSY. REPLACED SLIDE AT FWD LT DOOR. ALL CHECKS ARE NOW NORMAL.SDR 2008UALA00316Wire · shortedCABIN EMERGENCY LIGHTS TEST FAILED EXT LOADS FWD L. WIRING SHORT IN SLIDE PACK. REPLACED SLIDE AT DOOR 1R. OPS CHECKED NORMALLY.SDR 2008UALA00225Cover · missingSEATS 11C, 20C & 21C ARE MISSING THE EMERGENCY LIGHT LENS COVER. UNKNOWN PASSENGER DAMAGE. REPLACED LENS ON EMERGENCY LIGHTS ASSY AT ROW 11C, 20C, 21C. ALL LIGHTS OPERATIONAL.SDR 2007UALA03512Slide · failedDOOR 1L EMERGENCY SLIDE FAILS EMERGENCY LIGHT TEST. REPLACED DOOR 1L SLIDE PACK.SDR 2007UALA02332Slide · faultyEMERGENCY LIGHTS FAULTING EXTERNAL LOADS FWD LEFT.SDR 2007UALA02331Smoke Detector · faultyFWD CARGO COMPT SMOKE DETECTOR FAULT MESSAGE.SDR 2007UALA02297Structure · corrodedWATER WASTE VENT OUTLET AT RIGHT FUSELAGE BETWEEN FR 68 & 69 HAS HEAVY CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2007UALA01436Blades · failedRTFL WITH NR 1 ENGINE SHUT DOWN. LOUD BAND HEARD ON CLIMBOUT. REPLACED NR 1 ENGINE. [06-26-07] ENGINE INGESTED COWLING ACOUSTIC PANELS DURING CLIMBOUT CAUSING DAMAGE TO A STAGE 3 COMPRESSOR BLADE.SDR 2007UALA01151Slide · faultyCABIN EMERGENCY LIGHTS CHECK SHOWS -ATA 33 -51-38 EXT LOADS FWD L- RE-SET CIDS, MESSAGE RE-APPEARED. REPLACED DOOR 1L ESCAPE SLIDE.SDR 2007UALA01144Unknown · vibrationDURING CLIMB-OUT, AIRCRAFT VIBRATION VARYING SPEEDS AND ALTITUDES. CRUISE SMOOTH. [SUP 06-06-07] REPLACED ALL THREE RUDDER ACTUATOR ROD ENDS.SDR 2007UALA00941Controller · malfunctionedNOSE WHEEL STEERING FAULT AT GEAR DOWN. [SUP 06-01-07] REPLACED NOSE WHEEL STEERING SERVO CONTROL 6GC.SDR 2007UALA00150Light · no testEMERGENCY LIGHT TEST FAILED LEFT FWD DOOR SLIDE. FAULT READS EXT LOAD FWD LEFT. REPLACED DOOR 1L SLIDE PACK. EMERGENCY LIGHT TEST OK.SDR 2007UALA00018Slide · faultyEMERGENCY LIGHT TEST PER 3SV HAS FAULT, EXT LOADS FWD L FAULT. REPLACED DOOR 1R SLIDE.SDR 2006UALA02285Slide · faultyEMERGENCY LIGHT TEST FAULTS EXT LOADS FWD LEFT. UNBOLTED SLIDE, CLEANED CONNECTOR, REINSTALLED SLIDE. TEST PASSED.SDR 2006UALA01759Light · faultyACFT FAILS CABIN EMERGENCY LIGHT CHECK. CIDS FAULTS 33-51-38 EXT FWD LT. REPLACED NR 1 LEFT SLIDE.SDR 2006UALA01278Slide · failedDOOR 1R SLIDE FAILS EXT LOADS TEST IN EMERGENCY LIGHTS TEST. REPLACED SLIDE 1R PER AMM 25-62-44.SDR 2006UALA00943Slide · failedEXT LOADS FWD L, SHOWS ON PTP AFTER EMERGENCY SYSTEM TEST. REPLACED BOTH RIGHT HAND AND LEFT HAND FORWARD SLIDES. BOTH REMOVED SLIDES DID NOT RING-OUT CORRECTLY AT THE CONNECTOR. OPS TESTED NORMAL WITH NEW SLIDES.SDR 2006UALA00565Light · inoperativeDOOR 1L SLIDE EMERGENCY LIGHTS INOPERATIVE. REPLACED SLIDE, NO HELP. CONNECTOR 2871VC. FOUND DAMAGED, REPLACED. REINSTALLED DOOR 1R SLIDE, PER AMM 25-62-44. OPS CHECKED LIGHTS GOOD.SDR 2006UALA00509Control Unit · malfunctionedFWD CARGO PIT SMOKE WARNING ON FINAL. DISCHARGED AGENT 1 BOTTLE. ECAM WENT AWAY. FIRE DEPT ONSITE. TROULBESHOOTING PROCEDURES PERFORMED ON SMOKE DETECTION SYSTEM AND DISCOVERED SDCU CLASS II FAULT. REPLACED THE SDCU (10WQ) PCN:565-9019 PER AMM 26-17-34-40SDR 2005UALA01184Light · no testWHILE TESTING EMERGENCY LIGHTS FAULTED EXT LOADS FWD L HAD RED FAULT LIGHT EXT LOADS. WHILE PERFORMING THE AIRCRAFT EMERGENCY LIGHT TEST, SYSTEM MESSAGE POINTING TO FAULT IN FWD DOOR SLIDE ASSY. THE SLIDE WAS REPLACED SERVICEABLE ONE AND THE AIRCRAFT SYSTEMSDR 2005UALA00812Landing Gear · malfunctionedNOSE GEAR WOULD NOT LOCK IN UP POSITION.SDR 2004UALA00940Light · failedEMERGENCY LIGHTS TEST FAIL, FAULTS EXT LOADS FWD LT. AMPERAGE READING ON RECEIPT 0.00. CHANGED LIGHTS. AMPERAGE READING WAS .870 (NORMAL) AFTER REPACK.SDR 2004UALA00691Light · inoperativeEMERGENCY LIGHT TEST FAULTED EXT LOADS FWD L. THE EPSU FAULTED. REPLACED POWER SUPPLY. OPERATIONS CHECK NORMAL.SDR 2004UALA00355Wire · shortedON FINAL APPROACH WIRES UNDER SEAT 25B SPARKED ELECTRICAL SMOKE. HALON FIRE EXTINGUISHER USED. CAUSE OF ELECTRICAL SPARK WAS IDENTIFIED TO ORIGINATE FROM THE SEAT-TO-SEAT CABLE, WHICH CONNECTS BOTH PES AND PSS DATA. THIS CABLE ALSO CARRIES 110 VAC. PER AIRSDR 2001UALA00885Power Supply · dischargedCABIN EMERGENCY LIGHT TEST FAILED. REPLACED DOOR 1 LEFT SLIDE AND EMERGENCY LIGHT SYSTEM POWER SUPPLY ASSEMBLY.SDR 2000UALA00696Unknown · odorCHEMICAL SMELL IN ENTIRE CABIN. *S/D* FOUND DEICING FLUID ON APU INLET DOOR AND INLET DUCT. CLEANED INLET DOOR, DUCT AND SURROUNDING AIRCRAFT SKIN. TEST RUN APU AND BOTH ENGINES, RAN BOTH AIR CONDITIONING PACKS, NO FURTHER ODOR NOTED.SDR 2000UALA00486Oven · contaminatedGALLEY OVEN SMOKING. *S/D* CLEANED SPILL IN THE OVEN (P/N: 2710-0001-01) AND PERFORMED AN OPERATIONAL CHECK. NO FURTHER FAULTS WERE FOUND.SDR 2000UALA00485Bottle · dischargedDOOR 1 LEFT EMERGENCY ESCAPE RESERVOIR PRESSURE IS LOW. *S/D* SERVICED BOTTLE.SDR 99UAL900041Light · inopWOULD NOT PASS EMERGENCY LIGHT TEST. *S/D* CAUSES CANNOT BE DETERMINED FROM THE WRITE-UP. EMER LIGHT BATTERY PACK, POWER SUPPLY UNIT AND SLIDE WERE REPLACED. EMERGENCY LIGHT TEST WAS THEN CHECKED OK. BUT SHOP FINDINGS REVEALED NO AMP READINGS ON LIGHT SYSTESDR 97UAL900815Fan · failedDURING CRUISE, ELECTRICAL SMOKE SMELL IN COCKPIT WITH ECAM EXTRACT VENT FAULT AND VIBRATION FROM RT COCKPIT FLOOR. PUT EXTRACT VENT TO OVRHD, ODOR DISSIPATED, STILL HAD VIBRATION. CIRCUIT BREAKER PULLED FOR EXTRACT FAN, VIBRATION STOPPED.SDR 96UAL900595Light · failedEMERGENCY LIGHT SYSTEM FAILED TEST PER NR 2 SERVICE. *S/D* CHANGED P0WER SUPPLY AND BATTERY. ALSO, REPLACED SLIDE AND OPERATIONALLY CHECKED NORMAL.