N430UP
Service difficulty reports · 270
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N430UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N430UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2020073158471Flap System · malfunctionedON EXTENDING GEAR FLAPS 20 ON FINAL APPROACH, RECEIVED TE FLAP ASSYM EICAS. FLAP GUAGE SHOWED LEFT FLAP AT 15, RIGHT FLAP AT 18. EMERGENCY DECLARED. R & R THE LEFT OUTBOARD TE FLAP, OUTBOARD TEE GEARBOX IAW AMM 27-51-18-401. R & R TE FLAP SUPPORT BEARING OSDR IPXA2020070157210Panel · damagedINSPECTION TYPE:SEG3 DENT FOUND ON LT HORIZONTAL STABILIZER UPPER FWD TORQUE BOX PANEL JUST AFT OF AUX SPAR. REPAIRED AREA IAW B757 SRM 51-70-10-2R-2 PER SRM 55-10-01-1A-1.SDR IPXA2020062556980Floor Panel · damagedINSPECTION TYPE:SEG3 MAIN CARGO COMPARTMENT FLOOR PANEL 252XRF IS DAMAGED. FABRICATED PANEL 252XRF FROM 5024N40000155-G BAT 0003546253 PER SREO B757-5320-9692-K.SDR IPXA2020052625642Fan · failedINSPECTION TYPE:N/AIN FLIGHT AT FL 370"L RECIR FAN " EICAS MESSAGE ILLUMINATED ON AND OFF NUMEROUS TIMES AND N/S WITH MLP PANEL LIGHT GOING TO BRIGHT. DEFERRED LH RECIRCULATION FAN IAW MEL 21-25-1-2 DMP C/W.REPLACED LEFT CIRCULATION AIR FAN. OPS CK GOOD, REF 7SDR IPXA2019102248169Warning Message · false activationINSPECTION TYPE:N/ADIVERSION - WXR FAIL INDICATION ON EHSI ALSO GND PROX SYS STATUS MESSAGER@RD EGPWS PER AMM 34-46-01-401 OPS CK GOODSDR IPXA2018120766643Fseu · inoperativeAFTER TAKEOFF, RECEIVED A TE FLAP DISAGREE. AIR TURN BACK. REMOVED AND REPLACED THE NR 1 FSEU IAW AMM 27-51-01-022-006, AND 27-51-01-422-011. NO FAULTS NOTED T/E FLAP SYSTEM OP CHECKED GOOD IAW AMM 27-51-00-715-001.SDR IPXA2018062983181Floor Panel · delaminatedMAIN DECK FLOOR PANEL 231XJF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018062983179Floor Panel · delaminatedMAIN DECK FLOOR PANEL DELAMINATED. FABRICATED A NEW PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018062983177Floor Panel · delaminatedMAIN DECK FLOOR PANEL 231XFF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017061218159Elt · no testINSPECTION TYPE: PS2, ELT FAILED TEST. R & R THE ELT.SDR IPXA2017012313088Warning Message · false activationL1 DOOR EICAS. PERFORMED FIM 52-71-00-815-802 AND 32-09-03-815-813. ALL INDICATIONS IN FLT DECK & PSEU NORMALSDR IPXA2017011112620Stringer Clip · damagedSTRINGER CLIP DAMAGED AT AFT PRESSURE BULKHEAD. REMOVED AND REPLACED STRINGER THE STRINGER CLIP IAW EA 757-5381-27-A-2247, REV AND EO B757-5310-62854-ASDR IPXA2016062405015Skin Panel · brokenINSPECTION TYPE:SEG 1, LEFT WING LOWER SURFACE SKIN ABOVE PYLON PANEL 435BR IS CHAFED. REPAIRED WINGS, LOWER SKIN PANEL REPAIR BETWEEN WSTA 285.65 AND WSTA 313.50 AT STR 8 IAW EA 757-5724-27-A222 AND EO NR B757-5730-61103-A.SDR IPXA2015011285257Transmission · inoperativeDURING APPROACH, FLAPS SELECTED TO 1, FLAP INDICATOR REMAINED AT UP. T/E FLAP DISAGREE MESSAGE ON EICAS & T/E DISAGREE ILLUMINATED FOLLOWED AOM. DURING ALTERNATE FLAP EXT THE T/E FLAP DISAGREE WENT OUT AND L/E SLAT DISAGREE EICAS MSG CAME ON, AND L/E LIGHT SDR IPXA2014121585060Actuator · inoperativeEMERGENCY DECLARED. UPON SELECTION OF FLAPS 1 "T/E FLAP DISAGREE" MESSAGE ENNUNICATED WORKED T/E FLAP DISAGREE CHECKLIST WHICH CLEARED T/E PROBLEM, HOWEVER, THIS WAS FOLLOWED BY A "L/E SLAT DISAGREE" MSG. WORKED THAT CHECKLIST W/NO RELIEF TO L/E SLAT DISAGRSDR IPXA2014062383383Floor Panel · damaged4C12 INSPECTION, MAIN CARGO DECK FLOOR PANEL 241XLF IS MISSING AN INSERT. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014062383382Floor Panel · damaged4C12 INSPECTION, MAIN CARGO DECK FLOOR PANEL 242XLF IS MISSING AN INSERT. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014062383381Floor Panel · damaged4C12 INSPECTION, MAIN CARGO DECK FLOOR PANEL 241XDF HAS EDGE DAMAGED. FABRICATED NEW FLOOR PANEL IAW 757-5320-9692-H.SDR IPXA2014062383380Floor Panel · damaged4C12 INSPECTION, MAN CARGO DECK FLOOR PANEL 241XAF HAS CORNER DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014062383379Floor Panel · damaged4C12 INSPECTION, MAIN CARGO DECK FLOOR PANEL 241XFF HAS CORNER DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014062383378Floor Panel · punctured4C12 INSPECTION, MAIN CARGO DECK FLOOR PANEL 241XBF HAS PUNCTURED ON BOTTOM SIDE. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014062383377Floor Panel · damaged4C12 INSPECTION, MAIN CARGO DECK FLOOR PANEL 241XEF HAS CORNER DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014062383376Floor Panel · delaminatedMAIN CARGO DECK FLOOR PANEL 241XGF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014062383375Floor Panel · damaged4C12 INSPECTION, MAIN CARGO DECK FLOOR PANEL 242XMF HAS EDGE DAMAGED AT INSERT HOLE. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014582589Warning Message · false activationT/E FLAP DISAGREE. EMERGENCY DECLARED, PERFORMEND VISUAL INSPECTION OF FLAPS/SLATS AND FSEU BITE IAW FIM NO PREVIOUS OR CURRENT FAULTS DETECTED. FLAP OPS CHECKED NORMAL THRU SEVERAL CYCLES WITH NO FAULTS.SDR IPXA2014021981989Lamp · inoperativeEMERGENCY UNARMED INDICATION LIGHT INOPERATIVE. REPLACED LAMP IAW AMM 33-16-02 CHECKED GOOD.SDR IPXA12574821Floorboard · delaminatedINSPECTION TYPE:C, MAIN CARGO FLOORBOARD 251XHF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574820Floorboard · delaminatedINSPECTION TYPE:C, MAIN CARGO FLOORBOARD 251XLF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574785Floorboard · delaminatedINSPECTION TYPE:C, MAIN CABIN FLOORBOARD 251XGF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574728Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD 231XLF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574776Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 231XBF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574759Floor Panel · crackedINSPECTION TYPE: C-CK, MAIN CARGO FLOOR PANEL 221XBF IS CRACKED ACROSS FWD LT LEG OF PANEL. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574758Floor Panel · damagedINSPECTION TYPE: C-CK, MAIN CARGO FLOOR PANEL 232 XXF HAS EDGE DAMAGE/ DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574752Floor Panel · puncturedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XNF HAS SEVERAL PUNCTURES. FABRICATED MAIN CARGO FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574751Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XVF HAS INSERT PULLED FROM PANEL. FABRICATED NAIN CARGO FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA12574749Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XNF HAS CORNER/EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL HAS EDGE DAMAGE IAW EO 757-5320-9692-H.SDR IPXA12574748Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XAF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL HAS EDGE DAMAGE IAW EO 757-5320-9692-H.SDR IPXA12574747Floor Panel · damagedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 221XCF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574746Floor Panel · damagedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 231XGF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574742Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO BAY FLOOR PANEL 232XVF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574740Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XMF HAS INSERTS PULLED FROM PANEL. FABRICATED MAIN CARGO FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA12574734Floor Panel · puncturedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 222XAF HAS A PUNCTURE ON FWD RT OF PANEL. FABRICATED MAIN CARGO FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA12574733Floor Panel · puncturedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 232XAF SKIN IS PUNCTURED. FABRICATED MAIN CARGO FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA12574721Floorboard · delaminatedINSPECTION TYPE:C, FLOORBOARD NR 232XUF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9695-H.SDR IPXA12574718Floor Panel · delaminatedINSPECTION TYPE: C, LT SIDE FLOOR PANEL 231XSF DELAMINATED. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574997Frame · damagedINSPECTION TYPE: C, MAIN CARGO BAY BS 500 FRAME DAMAGE 5 INCHES ABOVE CREASE BEAM. REPAIR DAMAGED FRAME IAW EA 120936 AND EO B757-5310-48271-A.SDR IPXA12574973Frame · damagedINSPECTION TYPE: C, MAIN CARGO BS 520 RT, FRAME DAMAGED 5 INCHES ABOVE CREASE BEAM. REPAIRED IAW EA 120932 AND EO B757-5310-48269-A.SDR IPXA12574778Frame · dentedINSPECTION TYPE:C, FWD CARGO COMPARTMENT BS 800, BETWEEN STR 23R AND 24R, FRAME DENTED ON INBD FLANGE. CUTOUT DENT, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-00-07-2R 5, DETAIL III.SDR IPXA12574777Frame · dentedINSPECTION TYPE:C, FWD CARGO COMPARTMENT BS 740, BETWEEN STR 24R AND 25R, FRAME DENTED ON INBD FLANGE. CUTOUT DENT, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-00-07-2R5 DETAIL III.SDR IPXA12574775Frame · dentedINSPECTION TYPE:C, FWD CARGO COMPARTMENT BS 760, STR 23R, FRAME DENTED ON INBD FLANGE. CUTOUT DENT FABRICATED AND INSTALLED DOUBLER IAW SRM 53-00-07-2R 5, DETAIL III.
Back to N430UP