N434UA
Service difficulty reports · 132
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N434UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N434UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014043090913Mechanism · brokenFORWARD CARGO DOOR LOCKING HANDLE MECHANISM BROKEN.SDR CALA2014032090652Skin · crackedAT LOCATION Q A CRACK WAS FOUND ON FUSELAGE SIDE SHELL AT FRAME 35 & STRINGER 30L. CRACK WAS REPAIRED IAW ECRA 5330-04721.SDR CALA2014010990111Indication Sys · malfunctionedRT FIRE BOTTLE ON RT ENG SHOWS DISCHARGED ON OVERHEAD PANEL. ACP FIRE TEST NR 2 ENG & LIGHT CLEARED TESTED GOOD. ACP FDU2 TEST IN MCDU & TESTED OK NO MESSAGES.SDR CALA2013112693266Valve · openECAM HOT AIR FAULT, SELECTED HOT AIR OFF, STILL HAVE FAULT, VLV WILL NOT CLOSE.SDR CALA2013111892984Angle · damagedON PREFLIGHT WALK AROUND FIRST OFFICER NOTICED STRAP HANGING OFF LT AILERON. REPLACED T CHORD & L ANGLE.SDR CALA2013092791528Skin · crackedA CRACK WAS FOUND ON SKIN AT FR 35 & STRINGER 30L. CRACK REPAIRED IAW ECRA 5330-04721.SDR CALA2013092691463Skin · crackedDURING MAINTENANCE, A CRACK WAS FOUND ON SKIN AT FR 35 & STRINGER 30L. CRACK WAS REPAIRED IAW ECRA 5330-04721.SDR CALA2013091891271Sill · corrodedCORROSION ON L2 DOOR SILL AFT INBD CORNER. REMOVED CORROSION IAW SRM 53-41-14. MATERIAL LOSS WAS 0.030 & MAX MATERIAL LOSS ALLOWED IS 0.017\. OUT OF LIMITS IAW ABOVE SRM.SDR CALA2013091891270Sill · corrodedR2 DOOR SILL CORRODED AT FR 68.SDR UALA2013070804732Skin · damagedDURING WALK AROUND, FOUND THREE SEPARATE AREAS APPROXIMATELY TWO SQUARE INCHES MISSING FILLER MATERIAL. THEY ARE INTER-CONNECTED ALONG ELEVATOR T/E. SRM DOES NOT SPECIFY NEED TO CLEAN FOR THIS CARRY FORWARD. OK FOR SERVICE AND ACP PERM REPAIR WI THIN 100 DASDR CALA2013082990856Power Supply · faultyDURING COMPLETION OF OPERATIONAL CHECK OF THE EMERGENCY LIGHTING DURING ROUTINE S-C THE PTP DISPLAYED FAULT CODE EPSU UNIT AFT LT. R & R AFT LT EPSU 13WL, OPERATIONS CHECKED GOOD.SDR UALA2013070304660Drive Assy · failedWEATHER RADAR MAKES A NOISE AND VIBRATES COCKPIT FLOOR WITH EACH PASS. REPLACED DRIVE UNIT IAW AMM, OPS CHECKED GOOD. BITE TEST OK.SDR UALA2013062504419Battery Pack · failedEMERGENCY LIGHT TEST AT L1 DOOR ATTENDANT PANEL FAULTED, BATTERY EMERGENCY LIGHT RT WING. REPLACED EMERGENCY LIGHT BATTERY PACK. GROUND TESTED OK.SDR CALA2013082790803Eec · faultyENGINE ONE FADEC ALTERNATOR ECAM. IAW TSM73-22-00-810-835-B FOR TROUBLE SHOOTING, LCL MAINTENANCE CLEANED EDA CONNECTOR, ECAM RETURNS AS SOON AS MASTER SWITCH IS TURNED ON. FADEC 1A & 1B BOTH FAULTING "ALTCRF" CELL 58 & 59. EDA MR73206 PCN (482-1218), REPLACSDR UALA2013042902963Seal · missingOXYGEN BOX LATCH SEAL MISSING SEAT 27ABC. REPLACED SEAL.SDR UALA2013040302174Oxygen Mask · dislodgedOXYGEN MASKS FELL OUT IN ROW 28 DEF. REPACKED MASKS.SDR UALA2013032501853Crank Assy · faultyL1 DOOR NOT CLOSING. REPLACED CRANK ASSY AND ROLLER, RIG CHECKED GOOD.SDR UALA2013032501852Connector · looseAFT L EMERGENCY LIGHT BATTERY 13WL UNIT FAULT. FOUND CONNECTOR LOOSE AT EMERGENCY LIGHT PWR UNIT 13WL. RESECURED CONNECTOR. EMERGENCY LT POWER UNIT 13WL, CHECKED GOOD.SDR UALA2013032501851Battery · faultyRT EMERGENCY BATTERY FAULT. REPLACED EMERGENCY LT BATTERY AT RT EXIT ROW, CHECKED GOOD.SDR UALA2013031901689Container · out of rigO2 MASKS DROPPED ROW 10. O2 MASKS AT 10 DEF REPACKED REF MT 35-003. ACCOMPLISHED MANUAL MASK RELEASE OP CHECK REF MM 35 -23-00-710-001 WITHIN 3 DAYS. ACCOMPLISHED DROP CHECK REF MM 35-23-00. AWAITING EG FOR PROPER CONTAINER CONFIGURATION, TO VERIFY FOAM PADSDR UALA2013020400660Battery Pack · no testEMERGENCY LIGHT EPSU BATTERY PACK FWD LEFT FAILED BITE CHECK. REMOVED AND REPLACED BATTERY PACK IAW AMM, OPS CHECKED NORMAL.SDR UALA2013020400659Battery · no testEMERGENCY LIGHT EPSU BATTERY FAILED INTERNAL BITE CHECK. REMOVED AND REPLACED BATTERY, OPS CHECKED NORMAL.SDR UALA2012092105365Tie Bolt · shearedNR 3 MLG TIRE HAS 1 EA WHEEL TIE BOLTS SHEARED. REPLACED NR 3 MAIN TIRE ASSY PER AMM.SDR UALA2012070503621Outflow Valve · faultySKIN AIR EXTRACT EICAS, RTFL. CREW REPORTED NORMAL PRESSURIZATION. REPLACED AEVC AND SKIN AIR OUTLET VALVE AND ACCOMPLISHED OPERATIONAL TEST OF VENTILATION SYSTEM, ALL TESTS PASS.SDR UALA2012052903015Oxygen Mask · deployedROW 21 ABC O2 MASKS DEPLOYED. REPACKED O2 MASKS AT SEAT 21ABC. DROP TEST REQUIRED BEFORE THREE DAYS TIME. ACCOMPLISHED DROP TEST OK .SDR UALA2012032701944Sensor · out of adjustACFT WANTS TO PULL HARD TO THE RIGHT DURING TAXI, ACFT REQUIRES 8.7 UNITS OF LEFT RUDDER TRIM TO TAXI STRAIGHT. REPLACED LT SENSOR AND ADJUSTED PER MM. TAXIED ACFT STEERS STRAIGHT.SDR UALA2012032001794Computer · faultyVIBRATION NOISE ENCOUNTERED IN FLIGHT. REF FLT MANUAL 12.20.1 NEED TO COMPLETE VIBRATION REPORTING CHECKLIST AND DEBRIEF MAINTENANCE (SAMC) ON ARRIVAL TO DESTINATION STATION CREW COMMENTS: CONT...FL320-285KTS.78-148.4GW. PUT IN SLIGHT RUDDER BOTH L+R AND SMSDR UALA2012022001000Unknown · malfunctionedGEAR NOT DOWNLOCKED DISPLAYED ON UPPER ECAM SCREEN - L-G CREW COMMENTS: ON TAKEOFF AFTER AIRBORNE GOT MOMENTARY L-G GEAR NOT DOWNLOCKED ECAM WITH ASSOCIATED ALARMS. ACCOMPLISHED LANDING GEAR FUNCTIONAL TEST PER MM, NO FAULTS NOTED.SDR UALA2011112906560Oxygen Mask · defectivePORTABLE OXYGEN BOTTLE MASK DEFECTIVE - OXYGEN CREW COMMENTS: AFT BOTTLE MISSING FACE MASK, HAS CANULA. REPLACED AND SECURED.SDR UALA2011102805857Control Panel · faultyCAPTAIN'S RADIO VOLUME VERY LOW EXTREMELY DIFFICULT TO HEAR RADIO TRANSMISSIONS ON VHF 1. REPLACED AUDIO CONTROL PANEL 1. SYSTEM CHECKS NORMAL AT THE GATE.SDR UALA2011101705608Slide · crackedRIGHT OVERWING SLIDE HAS A 7.5 INCH CRACK, ALONG AFT EDGE. ALSO CRACKED IN 3, 6 INCH AND 3 INCH AND MULTIPLE CRACKS UPPER AFT EDGE. REPLACED RT OFF WING SLIDE ASSY PER AMM.SDR UALA2011101705599Oxygen Mask · unwanted deployPAX OXYGEN MASK DROPPED AT SEAT 25C. REPACKED O2 MASK, OPS CHECKED OK PER MM.SDR UALA2011072603825Computer · faultedWITH AP OFF A-C PITCHES UP UNCOMMANDED AT 3DEG PER SEC. MUST HOLD STICK FWD TO MAINTAIN ATT. SAMC TEXT: *UPDATE* CREW REPORTS WITH AP ON LIMITED TO .5 DEG PITCH TRIM, BUT ACFT STABLE. CFDS SHOWS HISTORY OF ELAC 2 AND ACCELEROMETER ISSUES. ELAC 2 PREV REPLASDR UALA2011072603824Computer · faultyFLT CTL MSG DISPLAY ON LOWER ECAM, FOUND ON PFR AND PLR MSG SEC 2 OR WIRING FROM ACCLRM 3 12CE3. ACP TSM 27-94-00-810-825 EFCS TEST SEC 2 FAULT MSGE,SWAPPED WITH SEC 3 FOR MAINTENANCE PURPOSES, AND FLT CTL MSG NO LONGER PRESENT ON ECAM AND SEC FAULT MSG NO DSDR UALA2011072203738Computer · faultedELAC2 AND ELEVATOR SERVO FAULT DISPLAYED. ATTEMPTED RESET, NO HELP. REPLACED ELAC 2. CHECKS NORMAL IAW AMM. AC REMAINS IN CAT III.SDR UALA2011060802811Support · out of toleranceNLG CONNECTOR SUPPORT OUT OF TOLERANCE. NEEDS PART NUMBER VERIFICATION. ROBBED BY LAX MM, FROM ACFT 4295. OPBLM MEYER. SAMC TEXT: PER LAX MM PART NUMBER D60687 VS D66670. REPLACED SUPPORT WITH PROPER PART, P/N IS D60687.SDR UALA2011032801484Bottle · low pressureDOOR 2R EMERGENCY DOOR CYL-ACCUM PRESSURE LOW. SERVICED BOTTLE TO 1750 PSI.SDR UALA2011032501442Acoustic Liner · tornTHREE SMALL TEARS IN THE ACOUSTIC MATERIAL INSIDE THE NUMBER ONE ENG COWLING. SAMC TEXT: REF MT 71-006. TEAR IN SKIN 3.5 INCHES LONG. EXCEEDS MT LIMITS. ACP REPAIR NR 1 PER MT 71-006.SDR UALA2011022400915Bottle · low pressureDOOR 2R, EMERGENCY DOOR ASSIST BOTTLE PRESSURE LOW. SVC BOTTLE PRESSURE IAW AMM.SDR UALA2010122004621Seal · unsecureO2 MASKS FELL DOWN. RESECURED RUBBER SEAL AROUND MASK PANEL AND AROUND O2 MASK DOOR.SDR UALA2010112404335Overheat Loop · faultedAPU BLEED AIR SUPPLY SYSTEM INOPERATIVE. APU BLEED LOOP FAULTED CFDS36-22-17 APU LOOP. APU BLEED INOP DUE TO BLEED LEAK ECAM. BOTH ENDS OF LOOP 14HF ARE DISCONNECTED. LOOP IS LOCATED IN AFT PIT LEFT SIDE WALL. REMOVED BAD LOOP, 14HF. AWAITING NEW LOOP, SDR UALA2010102803981Oxygen Mask · unwanted deployOXY MASKS DEPLOYED FROM OVERHEAD. REQUIRES DROP TEST BEFORE SEATS CAN BE OCCUPIED. RESET O-2 DOOR. PERFORMED OPS CK IAW AMM. OPS CHECKED GOOD.SDR UALA2010092403543Power Supply · inoperativeEPSU FAULT LEFT DISPLAYED WHILE DOING INTERIOR EMERGENCY LIGHT TEST. UNIT FAULTING WHILE DOING EPSU SELF TEST. REPLACED POWER SUPPLY UNIT AND BATTERY. OPS CHK GOOD.SDR UALA2010091403419Skin · damagedLT MED HAS DAMAGE. MAJOR REPAIR ACCOMPLISHED: FLUSH DOUBLE INSTALLED JUST FWD LT MED 1 APPROX FR 11 STR 20L.SDR UALA2010090103216Control Unit · inoperativeSDCU INOP, RTFL. REPLACED SDCU IAW AMM26-17-34. ALL TESTS NORMALSDR UALA2010081602971Cover · missingDOOR 2L EMERGENCY LIGHT SWITCH BUTTON COVER MISSING. REPLACED AFT PANEL 126RH. ALL SWITCHED OPERATED.SDR UALA2010071902570Skin · damagedCREW REPORTED DAMAGE TO NOSE AREA FWD OF NOSE GEAR. APPROX 8 INCHES FWD OF NOSE EE DOOR, ACROSS EE DOOR AND 1' AFT. BLENDED DAMAGE FWD OF E&E DOOR WITHIN LIMITS AND PRIMED. CUT OUT DAMAGE AFT OF DOOR PERFORMED NDT INSP OF DAMAGE REMOVAL FRAMES AND STRINGER NOSDR UALA2010061602120Power Supply · inoperativeEMERGENCY LIGHT TEST FAULT, 'EPSU INT LOAD EMER R'. REPLACED POWER SUPPLY UNIT AND BATTERY. EMERGENCY LIGHT TEST OK.SDR UALA2010061402069Power Supply · failedEMERGENCY LIGHT TEST FAIL. EPSU UNIT EMERGENCY LIGHT. REPLACED LIGHT EMERGENCY POWER SUPPLY UNIT PN 3214-54-10.SDR UALA2010020200422Battery · inoperativeEMERGENCY LIGHT TEST FAILED DURING ACCOMPLISHMENT OF NR 3 SERVICE. TEST FAULTED EPSU EMERGENCY R. REPLACED BATTERY. TEST PASSED.
Back to N434UA