N436YX
Service difficulty reports · 17
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N436YX' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N436YX' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A2025101300432Skin · dentedDENT ON LH SIDE OF FUSELAGE AT FRA 80 BETWEEN STR 22L AND 23L. REPAIRED USING FILLER,DOUBLER AND TRIPLER IAW EMB ETD2025-170-927669 REV A. ALSO REF VP-043665-2025 N/R #1 FOR WORK ACCOMPLISHED.SDR R61A2024061400267Shear Tie · corrodedSHEAR CLIP FR88 STGR 28R-27R HAS CORROSION. REMOVED AND REPLACED SHEAR CLIP AT FR 88 STGR 27R-28R. REF EMB SRM 51-40-08SDR R61A2024012600053Mau · failedAC BUS 1 OFF, DC BUS 1 OFF, AVNX MAU 1B FAIL, EFIS SCREEN 1 AND 4 INOP. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. AFTER LANDING, ELEVATOR LH FAIL, RUDDER FAIL, TERRAIN FAIL, RAT FAIL. RESET AIRCRAFT POWER, ALL FAULTS CLEARED.SDR R61A2021102200823Power Supply · inoperativeFWD GALLEY EMERGENCY LIGHT DOES NOT LIGHT UP. R&R #2 EMERGENCY LIGHT POWER SUPPLY IAW AMM 33-50-01.SDR R61A2020012170044Glowstrip · fadedFWD WARDROBE PHOTO-LUMINESCENT GLOW STRIP FADED. R&R PHOTOLUMINESCENT GLOW STRIP IN FRONT OF FWD WARDROBE IAW AMM 33-50-21.SDR R61A201812021188Doubler · corrodedWHILE THE ACFT IS IN HEAVY CHECK MAINT FOUND CORROSION AT FWD WET AREA 3 HOLE DOUBLER FR 13-14 AS MARKED. REMOVED AND REPLACED 3 HOLE DOUBLER FWD WET AREA REF SRM 51-40-08.SDR R61A201812021187Seat Track · corrodedWHILE THE ACFT IS IN HEAVY CHECK MAINT FOUND CORROSION STRUCTURAL CENTER FUSELAGE III DRY AREA 53-23 LT SEAT TRACK FRAME 84. REMOVED AND REPLACED LT SEAT TRACK AT FR 84.RESTORED SURFACE PROTECTANT TO LT SEAT TRACK FRAME 84 FILLER AND SPLICE REF SRM 51-23-04, 5SDR R61A201812021186Shear Plate · corrodedWHILE THE ACFT IS IN HEAVY CHECK MAINT FOUND CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RT SHEAR PLATE. REMOVED AND REPLACED CENTER FUSELAGE III WET AREA 53-23 FR 87-88 RT SHEAR PLATE. REF SRM 51-40-02, 51-23-04. ACFT REMAINS IN HEAVY CHECK UNTIL SDR R61A201812021185Access Panel · corrodedWHILE THE ACFT WAS IN HEAVY CHECK, FOUND CORROSION ON WASTE SERVICE PANEL INTERNAL SIDE. REMOVE AND REPLACED WASTE SERVICE PANEL REF AMM 20-10-01. RESTORED SURFACE PROTECTION SRM 51-23-06. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.SDR R61A2018071300782Warning System · false activationBLEED 2 OVERPRESSURE ON CLIMBOUT AT 400 FEET. RAN QRH, MESSAGE PERSISTED. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. PERFORMED AMS CHANNEL 1 AND 2 RESET ALL MESSAGES CLEARED. RAN E2 AT IDLE AND NO FAULTS FOUND. TQ MOTOR TESTED NFF IAW LMM 72-00-00. TRANSITORSDR R61A201710180768Light · inoperativeEMERGENCY LIGHT AT R1 DOOR SURROUND BOTTOM SIDE INOP. R & R THE EMERGENCY LIGHT IAW AMM 33-50-19.SDR R61A201710180767Power Supply · inoperativeEMERGENCY LIGHT AT THE R1 DOOR SURROUND BOTTOM SIDE INOPERATIVE. R & R THE POWER SUPPLY IAW AMM 33-50-01.SDR R61A201701310079Flashlight · inoperativeMAINTENANCE REPORTED THAT THE AFT RIGHT FLIGHT ATTENDANT FLASHLIGHT CHARGING INDICATOR WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.SDR R61A201701060028Contact · dirtyCREW REPORTED THAT THE AFT GALLEY SPARE FLIGHT ATTENDANT FLASHLIGHT WAS NOT STAYING CHARGED. MAINTENANCE CLEANED CONTACTS IAW AMM AND OPS CHECKED GOOD.SDR R61A201604180248Warning Message · false activationCREW RECEIVED A FLAP FAIL MESSAGE. CREW RAN QRH AND DESCENDED TO FL 190. CREW DECLARED AN EMERGENCY AND WITH VEHICLES ROLLING, LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED FIM 27-53-00-810-826-ACE IAW AMM WITH NO DEFECTS NOTED. MAINTENANCE CLEARED INHIBITS,SDR R61A201510270765Lamp · inoperativeCREW REPORTED THAT THE F/O FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE LAMP IN THE F/O FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.SDR R61A201508220554Light · inoperativeMAINTENANCE REPORTED THAT THE PHOTOLUMINESCENT STRIP AT ROW 1D WAS INOPERATIVE. MAINTENANCE R & R PHOTOLUMINESCENT STRIP AT ROW 1D IAW AMM AND OPS CHECKED GOOD.
Back to N436YX