N437UP
Service difficulty reports · 165
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N437UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N437UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2016042502573Floor Support · corrodedINSPECTION TYPE:C-12, AFT PIT, FLOOR STRUCTURE AND BILGE SKIN CORRODED, BS 1400-RBL 3. REPLACED INTERCOSTAL BS 1400 TO BS 1420 AT RBL 3.SDR IPXA2016042502571Strap · corrodedINSPECTION TYPE:C-12, AFT PIT, FLOOR STRUCTURE AND BILGE SKIN CORRODED BS 1400-RBL 3. REPLACED STRAP BS 1400, S28R-S26L.SDR IPXA2016041602206Frame · dentedINSPECTION TYPE:C-12, AFT CARGO COMPARTMENT RT FRAME AT BS 1500 IS DENTED APPROXIMATELY 4" ABOVE S26R. REPAIRED FRAME AT RT BS 1500 IAW SRM 53-00-+07-2R-5, FIG 201,
DETAIL II.SDR IPXA2014050282857Floorboard · crackedDURING C11 INSPECTION, MAIN CABIN FLOORBOARD 232XHF IS CRACKED. REPLACED FLOORBOARD IAW REO B757-5320-9692-H.SDR IPXA2014042882805Floorboard · puncturedDURING C-11 INSPECTION, MAIN CABIN FLOORBOARD 251XNF IS PUNCTURED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014042882802Floorboard · damagedDURING C-11 INSPECTION, MAIN CABIN FLOORBOARD 232XTF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014042882801Floor Panel · damagedDURING C-11 INSPECTION, MAIN CABIN FLOOOR PANEL 232XGF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2014042882807Floorboard · damagedDURING A C-11 INSPECTION, MAIN CABIN FLOORBOARD 231XFF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW 5320-9692-H.SDR IPXA2014042882806Floorboard · damagedDURING C-11 INSPECTION, MAIN CABIN FLOORBAORD 252XKF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014042882804Floorboard · damagedDURING C-11 INSPECTION, MAIN CABIN FLOORBAORD 231XHF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW 5320-9692-H.SDR IPXA2014042882803Floorboard · damagedDURING C-11 INSPECTION, MAIN CABIN FLOORBOARD 231XGF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW 5320-9692-H.SDR IPXA2014042882790Floorboard · damagedDURING C11 INSPECTION, MAIN CABIN FLOORBOARD 231XWF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014042882783Floorboard · damagedDURING A C-8 INSPECTION, MAIN CABIN FLOORBOARD 251XRF FOUND WITH EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014042882782Floorboard · damagedDURING C-8 INSPECTION, MAIN CABIN FLOORBOARD 252XUF FOUND WITH EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW 5320-9692-H.SDR IPXA2014042882780Floor Panel · damagedDURING C11 INSPECTION, FLOOR PANEL 211XAF HAS CORE DAMAGE AND SURFACE DISBONDED. FABRICATED FLOOR PANEL IAW SREO B757-5320-4692-H.SDR IPXA2014042882779Floor Panel · delaminatedC11 INSPECTION, FLIGHT DECK FLOOR PANEL IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA13579229Pressure Switch · inoperativeLEFT ENGINE OIL PRESSURE CAUTION & LT ENGINE OIL PRESSURE EICAS ILLUMINATED IN FLIGHT. LT OIL PRESSURE 5 UNITS LESS THAN RT. LT OIL QTY 2 QUARTS LESS THAN RT ENGINE OPERATED LT ENGINE AT RESERVE THRUST TO LANDING. NOTED ENGINE OIL PRESSURE NORMAL. REPLACEDSDR IPXA2573415Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 242XAF IS DAMAGED AT FWD EDGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2573414Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 241XDF IS DAMAGED AT FWD EDGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2573413Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 241XJF IS DAMAGED AT FWD EDGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2573412Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 242XJF IS DAMAGED AT AFT EDGE. FABRICATED FLOOR PANEL 242XJF IAW EO B757-5320-9692-H.SDR IPXA2573411Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 242XDF IS DAMAGED AT AFT EDGE. FABRICATED FLOOR PANEL 242XDF IAW EO B757-5320 -9692-H.SDR IPXA2573410Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 241XBF IS DAMAGED AT FWD EDGE AND AFT EDGE. FABRICATED FLOOR PANEL 241XBF IAW EO B757-5320 -9692-H.SDR IPXA2573409Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 241XCF IS DAMAGED AT FWD EDGE. FABRICATED FLOOR PANEL IAW EO B757-5320 -9692-H.SDR IPXA2573408Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOOR PANEL 242XCF IS DAMAGED AT FWD EDGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA1567943Floor Panel · damagedPOS 1L FLOOR PANEL IS DAMAGED BEYOND LIMITS. IDENTIFIED PANEL AS FROM POS 1L PANEL PN141N5410-15 IAW EO B7575320 9692G FABRICATED A REPLACMENT PANEL BY CUTTING OUT NEW PANEL FROM A402 H AND MARKING INSERTS LOCATION USING OLD PANEL AS A TEMPLATE DRILLED A ND CSDR IPXA1567942Floor Panel · damagedPOS 1L CENTER FLOOR PANEL IS DAMAGED BEYOND LIMITS. IDENTIFIED PANEL AS FROM POS 1L CENTER PANEL PN 141N5410-16 IAW EO B7575320-9692G FABRICATED A REPLACEMENT PANEL BY CUTTING OUT A NEW PANEL FROM A402H AND MARKING INSERT LOCATION USING OLD PANEL AS TEMPLATE.SDR IPXA1567941Floor Panel · damagedPOS 1R CENTER FLOOR PANEL IS DAMAGED BEYOND LIMITS. IDENTIFIED PANELS FROM POS 1R CTR PN141N5410-17 IAW EO B7575320 9692G FABRICATED A REPLACEMENT PANEL BY CUTTING OUT A NEW PANEL FROM A A402H AND MARKING INSERTS LOCATION USING OLD PANEL AS TEMPLATE. DRILLEDSDR IPXA1567940Floor Panel · damagedPOS 1R FLOOR PANEL IS DAMAGED BEYOND LIMITS. IDENTIFIED PANEL AS FROM POS 1R, PANEL PN 141N5410-18 IAW EO B7575320 9692G. FABRICATED A REPLACEMENT PANEL BY CUTTING OUT A NEW PANEL FROM A A402H AND MARKING INSERT LOCATION USING OLD PANEL AS TEMPLATE DRILLED ASDR IPXA1567939Floor Panel · damagedPOS 1R PANEL IS DAMAGED BEYOND LIMITS IDENTIFIED PANEL AS FROM POS 1R PANEL PN141N5410-19 IAW EO B7575320- 9692G FABRICATED A REPLACMENT PANEL BY CUTTING BY CUTTING OUT A NEW PANEL FROM A402H AND MARKING INSERT LOCATION USING OLD PANEL AS TEMPLATE DRILLED AND SDR IPXA1567938Floor Panel · damagedPOS 1R FLOOR PANEL IS DAMAGED BEYOND LIMITS. IDENTIFIED PANEL AS FROM POS 1R PANEL PN143N5410-20 IAW EO B757-5320 9692G FABRICATED A REPLACEMENT PANEL BY CUTTING OUT A NEW PANEL FROM A4 02H AND MARKING INSERT LOCATION USING OLD PANEL AS TEMPLATE DRILLED AND CSDR IPXA1567937Floor Panel · damagedPOS 2L FLOOR PANEL IS DAMAGED BEYOND LIMITS. IDENTIFIED PANEL AS FROM POS 2L PN 143N5457-81 IAW EO B757-5320-9692G G FABRICATED A REPLACEMENT PANEL BY CUTTING OUT A NEW FROM A402H AND MARKED INSERT LOCATION USING OLD PANEL AS TEMPLATE. DRILLED AND CLEANED HOSDR IPXA1567936Floor Panel · damagedPOS 2L CENTER FLOOR PANEL IS DAMAGED BEYOND LIMITS IDENTIFIED PANEL AS FROM POS 2L CR PN 143N5457-3 IAW EOB757-5320 9692-G FABRICATED A REPLACMENT PANEL BY CUTTING OUT A NEW PANEL FROM A 402H AND MARKING INSERT LOCATION USING OLD PANEL AS A TEMPLATE. DRILLED SDR IPXA1567935Floor Panel · damagedCENTER FLOOR PANEL IS DAMAGED BEYOND LIMITS. IDENTIFIED PANEL AS FROM POS 2L CENTER PN 143N5457-5 IAW EO B7575320 9692-G. FABRICATED A REPLACMENT PANEL BY CUTTING OUT A NEW PANEL FROM A 402H AND MARKED INSERT LOCATION USING OLD PANEL AS TEMPLATE DRILLED AN DSDR IPXA1567934Floor Panel · damagedPOSITION 2R CENTER FLOOR PANEL DAMAGED BEYOND LIMITS. IDENTIFIED PANEL FROM POSITION 2R CENTERPANEL, PN 143N5457-5 FABRICATED A REPLACEMENT PANEL BY CUTTING OUT A NEW PANEL FROM A402H AND MARKING INSERT LOCATION USING OLD PANEL AS TEMPLATE. DRILLED AND CLEANSDR IPXA1567933Floor Panel · damagedPOSITION 2R FLOOR PANEL IS DAMAGED BEYOND LIMITS. IDENTIFIED PANEL AS FROM POSITION 2R PANEL PN 143N5457-82 IAW EO B767- 5320-9692G FABRICATED A REPLACEMENT PANEL BY CUTTING OUT A NEW PANEL FROM A402H AND MARKED INSERT LOCATION USING EXISTING PANEL AS A TEMPLSDR IPXA10563485Window · bindsF/O'S SLIDING WINDOW DIFFICULT TO OPEN, BINDS IN TRACK, FOUND LINK ARM BUSHING WORN. R & R LINK ARM ASSY LUBED TRACKS & SECURED C-SCREW SHAFT IAW 56-11-02 F/O'S NR 2 SLIDING WINDOW. OPS CK'S GOOD.SDR IPXA10560386Shear Web · corrodedINSP TYPE:C1, FOR RCO TRACKING PURPOSES THERE IS CORROSION ON THE MAIN CARGO BAY UPPER SURFACE BS 1717, LBL 8, WL 208. SHEAR WEB WAS REPAIRED IAW ATS ER NR 10-2837.SDR IPXA10559966Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD DAMAGED IN NUMEROUS SPOTS, BOTTOM SIDE BS 620-720 LBL 45-65. REPLACED IAW EO B757-5320-9692-G, B757-5100-33281-B.SDR IPXA0560644Shear Web · damagedINSPECTION TYPE:C1, WHILE WORKING CUSTOMER CARD 860401, FOUND FIG 8 HOLE AT BS 336, LBL 61, WL 208. REPAIRED IAW ATS ER NR 10-2816.SDR IPXA10560146Support Angle · crackedINSPECTION TYPE:C1, WING TO BODY FAIRING FORMER SUPPORT BRACKET IS CRACKED AT BS 1300, STR 24R, AT THE UPPER END OF THE FLANGE AGAINST THE SKIN REPLACED SUPPORT BRACKET IAW SRM 51-40-02-0G.SDR IPXA10560585Floorbeam · corrodedINSPECTION TYPE:C1, DUE TO RCD PROCESS, REPAIR REQUIRED AT BS 1200 FLOORBEAM, FWD FLANGE, RBL9, WL 208. REPAIRED IAW EO B757-5310-37909-A.SDR IPXA0560646Shear Web · corrodedINSPECTION TYPE:C1, FOUND CORROSION ON SHEAR WEB AT STA 412, ON LBL 48. REPAIR IAW ATS ER NR10-2816.SDR IPXA0560645Shear Web · corrodedINSPECTION TYPE:C1, FOUND CORROSION ON SHEAR WEB AT STA 355, LBL-48. REPAIRED IAW ATS ER 10-2816.SDR IPXA0560643Shear Web · corrodedINSPECTION TYPE:C1, FOUND CORROSION ON SHEAR WEB AT STA 341 ON LBL-65 REPAIRED IAW ATS ER 10-2816 SECTION IV AND V.SDR IPXA0560642Shear Web · corrodedINSPECTION TYPE:C1, FOUND CORROSION ON SHEAR WEB AT STA 402 ON LBL-48. REPAIRED IAW ER 10-2816 SECTION IV AND V.SDR IPXA10560506Shear Web · corrodedINSPECTION TYPE:C1, FOUND CORROSION ON SHEAR WEB STA 341 AT RBL 13 TO 24. REMOVED CORROSION AND REPAIRED SHEAR WEB IAW SRM 51-10-02-0G, SRM 51-40-02-0G, AND ER NR 10-2776.SDR IPXA10560402Strap · corrodedINSPECTION TYPE:C1, OUTER STRAP AT STA 1825 BETWEEN STR 3 AND STR 6 IS CORRODED. REPAIRED IAW UPS EO B757-5330-38077-A.SDR IPXA10559984Brace · crackedINSPECTION TYPE: MOD, NR 1 PYLON AFT UNDERWING FAIRING STRUCTURE LT FWD BRACE IS CRACKED. R & R BRACE IAW SRM 51-40-02-0G.SDR IPXA10559981Support Angle · corrodedINSPECTION TYPE:C1, ANGLE AT STR 6R BETWEEN 1825 AND 1787 IS CORRODED. R & R ANGLE IAW SRM51-40-02-0G.
Back to N437UP