N439UA
Service difficulty reports · 157
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N439UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N439UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013082990854Battery · faultyWHEN PERFORMING 2 SERVICE FOUND EMERGENCY LIGHT BATTERY FAULT. REPLACED BATTERY FOR 12WL IAW AMM 33-51-038-000-001-A.SDR UALA2013062604451Switch · inoperativeFIRST OBSERVERS SEAT, CREW OXYGEN PRESS TO TEST, DOESN`T TEST.SDR UALA2013041802653Spring · lack of lubeFORWARD AFT LAV DOOR LOCK MECHANISM IS JAMMED. LUBED LOWER RELEASE SPRING, OPS OKAY.SDR UALA2013031101453Door Seal · vibrationVIBRATION FELT IN FLOOR OF COCKPIT. FEELS LIKE SOURCE IS UNDER-FORWARD AND RIGHT. MAINT TEXT: CREW REPORTED VIBRATION THROUGHOUT FLT MOST AT CRUISE ALT ONLY IN COCKPIT, PILOT SAID NOTHING OUTSIDE OF FLT DECK. REPLACED FWD LEFT NOSE GEAR DOOR AFT SEAL.SDR UALA201301030027Mechanism · lack of lubeRUDDER PEDAL ADJ LVR DOES NOT RLS PEDALS 4 ADJUSTMENT ON F-O SIDE. SUPPLEMENTAL DATA UPDATE LUBRICATED RUDDER PEDAL ADJUSTMENT MECHANISM.SDR UALA2012112106723Oxygen Mask · kinkedCAPT O2 MASK HEAD STRAP HARNESS IS KINKED. INSTALLED MASK AND PERFORMED OP TEST.SDR UALA2012103106266Filter · dirtyZONE TEMP CONTROLLERS NEEDED TO STAY IN FULL COLD FOR CABIN TO REMAIN COMFORTABLE. CLEANED CABIN AIR TEMP SENSOR FILTERS, CABIN TEMPERATURE CONTROL, OPS CHECKED NORMAL.SDR UALA2012101705947Accumulator · failedEMERGENCY GENERATION TEST FAILED, FOUND BLUE ACCUM PRESS ZERO. REMOVED AND REPLACED BLUE POWER ACCUMULATOR PER MM, OPS CHECKS NORMAL.SDR UALA2012092705458Toilet · noisyCREW REPORT: FORWARD AFT LAV EXTREMELY LOUD - AS IF A PRESSURE LEAK. CABIN PRESSURIZATION SHOWS NORMAL. REPLACED THE TOILET ASSY IAW AMM AND TOILET FLUSHES NORMALLY.SDR UALA2012072404012Warning Light · false activationAFT CARGO DOOR INDICATES OPEN IN FLIGHT. PRESSURIZATION NORMAL. ACCOMPLISHED MM 52-32-00 TO VERIFY CARGO DOOR IS SECURELY LOCKED.SDR UALA2012060303083Slide · delaminatedLT OVERWING SLIDE DOOR DELAMINATED. DELAMINATION IS MORE THAN ALLOWABLE LIMITS PER MM. DELAMINATION MEASURED IN 2 PLACES ADDS UP TO APPROXIMATELY 18.75 SQUARE INCHES. REPLACED SLIDE.SDR UALA2012052302885Computer · faultyELAC 1 PITCH FAULT ECAM AND ALT DISC OF 500 FT BTWN CAPTAIN AND FIRST OFFICERS ALT. RTFL. ALTITUDE DISCREPANCY OF 500' BTWN CAPT & F-O ALTIMETER. POSSIBLE PCN :482-9080. IDT REQUIRED. RMV'D & RPLC'D 19FP 2 AIR DATA MODULE, OPS CHECKED GOOD. ELAC 1 PITCH FAULSDR UALA2012030501402Windshield · damagedCAPTAIN'S FIXED SIDE WINDOW'S VISIBILITY IS IMPAIRED. DELAM AT 6 O'CLOCK POSIT+BUBBLES AT 9 O'CLOCK. SCRATCHES ALONG L-SIDE INHIBIT ICE DETECTION ON LT WING. REMOVED AND REPLACED LEFT SIDE CLEAR VIEW WINDOW PER AMM.SDR UALA2012020700735Container · malfunctionedSEAT 34DEF O2 MASK CONTAINER DID NOT OPEN DURING TEST. REPACK PER AMM AND MASK RELEASE PER AMM, NORMAL.SDR UALA2012020700734Container · malfunctionedSEAT 24ABC O2 MASK CONTAINER WILL NOT CLOSE AFTER TEST. REPACKED PER AMM AND MASK RELEASE PER AMM, NORMAL.SDR UALA2012020700732Container · malfunctionedSEAT 23ABC O2 MASK CONTAINER WILL NOT CLOSE AFTER TEST. REPACK PER AMM AND MASK RELEASE PER AMM, NORMAL.SDR UALA2012020700731Container · malfunctionedSEAT 20 DEF O2 MASK CONTAINER DID NOT OPEN DURING TEST. REPACK PER AMM AND RELEASE PER AMM, NORMAL.SDR UALA2012020700730Container · malfunctionedSEAT 12ABC O2 MASK CONTAINER DID NOT OPEN DURING TEST. REPACK PER AMM AND MASK RELEASE PER AMM NORMAL.SDR UALA2012020700729Latch · faultySEAT 11ABC O2 MASK CONTAINER OPENED DURING TEST. REPLACED MAINTENANCE LATCH AND SPRING.SDR UALA2012020700728Container · malfunctionedSEAT 8DEF O2 MASK CONTAINER WILL NOT CLOSE AFTER TEST. ACCOMPLISHED AMM 35-23-00 -550-003 AND AMM 35-23-00-710-001 MASK RELEASE NORMAL.SDR UALA2012020700727Container · malfunctionedSEAT 3ABC O2 MASK CONTAINER WILL NOT CLOSE AFTER TEST REF MM. ACCOMPLISHED AMM 35-23-00 -550-003 MASK REPACK AND OPS TEST AMM 35-23-00-710-001 NORMAL.SDR UALA2011110906096Bolt · backed outNR 1 ENGINE EXHAUST CONE BOLT BACKED OUT AT 6 O'CLOCK POSITION. CHASED THREADS AND INSTALLED NEW BOLT AND TORQUED PER MM.SDR UALA2011103105871Tail Cone · crackedRAMP FOUND A 6 INCH CRACK AT 6 O`CLOCK ON TAIL CONE, OF LEFT ENGINE. REMOVED OLD AND INSTALLED NEW ENGINE EXHAUST TAIL CONE PER MM.SDR UALA2011081504306Skin Panel · delaminatedFOUND DELAM ON PANEL 191DB AIR START PANEL LT SIDE. TAPED DAMAGE IN ACCORDANCE WITH SRM. NR 2 REPAIR WITHIN 1000 FH.SDR UALA2011080103938Seal · dirtyDOOR 2R PRESS LEAK IN CLIMB. CLEANED DIRT AND DEBRIS FROM THRESHOLD AREA. ALSO CLEANED DOOR SEAL. NO RECENT HISTORY IN AMIS.SDR UALA2011071303536Generator · faultyF/A REPORTED A SIREN NOISE AND VIBRATION IN REAR OF A-C. NOTICED AROUND 14,000FT. STOPPED B4 LANDING. SUSPECT LAV-GALLEY EXTRACT FAN. DURING GROUND OPS, LAVATORY VACUUM GENERATOR PRODUCES RUMBLING, EXCESSIVE NOISE AND VIBRATION. NOTED INFORMATION REGARDINSDR UALA2011071303535Rod End · wornRIGHT ELEVATOR YELLOW ELEVATOR SERVO CONTROL ROD END HAS EXCESSIVE PLAY. DETERMINATION FOUND TO BE ELEV REPLACED RIGHT YELLOW SERVO ROD END, OPS CHECK NORMAL.SDR UALA2011070703387Bottle · low pressureTHE 2R LOW BOTTLE PRESSURE. SERVICED THE DOOR GAS BOTTLE CYL PER MM.SDR UALA2011062903207Container · faultedAFT FLIGHT ATTENDANT EMERGENCY OXYGEN MASK WOULD NOT DEPLOY DURING THE OPERATIONAL TEST FOR THE PASSENGER EMERGENCY OXYGEN SYS TEST. AFT FLIGHT ATTENDANT SEAT WILL BE INOP. SEATS FOR FLIGHT ATTENDANTS ARE 37C AND D. REPLACED O2 CONTAINER AND PERFORMED O2 MASDR UALA2011052302522Valve · leakingPRIOR TO ENG START, RT WING STARTED LEAKING FUEL OUT OF VENT. MAINT TEXT: WITH RIGHT WING TANK FULL AND BOOST PUMPS RUNNING, FOUND FUEL LEAKING INTO VENT TANK THROUGH UPPER VENT HOLE IN VENT TANK. REPLACED RT WING SUCTION VALVE REF AMM, CHECKS GOOD.SDR UALA2011051602402O-Ring · damagedJUST BEFORE PUSHBACK, FUEL SPILL COMING FROM RT WING VENT PANEL. FUEL STOPPED FLOWING AFTER 10 MINS. SAMC TEXT: POSSIBLE TSM REFERENCE 28-21-00-810-825. -SURGE TANK DRAIN VLV LEAKING. RPL O-RING. OPS CK OF PRESS FUELING SYS NORMAL, NO FUEL IN SURGE TANK ASDR UALA2010072602685Amu · inoperativeF/O'S OXYGEN MASK MICROPHONE IS INOPERATIVE. REPLACED BOX, NO HELP. REPLACED AMU PER MM. MASK MIC OPS NORMAL.SDR UALA2010030900814Wire · chafedDURING TROUBLESHOOTING OF ENG 1 AND 2 IGN SYS A CB A3 POPPED FOUND WIRES 5A421B16 AND 5A421W16 CHAFED AND ARCING AGAINST BRACKET ABOVE OIL TANK QUANTITY TRANSMITTER. REFER TO WDM71-51-04 P003 FIG 1. SPLICED IN NEW SECTION OF CABLE FROM BELOW FUEL-OIL COOLER SDR UALA2009121703910Cover · missingLENS MISSING FROM EPL EXIT SIGN AT AFT LT EMERGENCY EXIT. REPLACED LIGHT COVER.SDR UALA2009111603564Inlet · damagedRAMP CREW REPORTS FINDING DAMAGE TO THE INLET COWL ABOUT 2:00 POSITION (ALF) SIX INCHES AFT OF THE LE. REPAIRED IN SHOP ON RR R13 469 AND REINSTALLED.SDR UALA2009050601304Gcu · malfunctionedF/A REPORT CABIN LIGHTING NO SMOKE LIGHTS F/A CALL LIGHTS AND EXIT LIGHTS FLICKERING THROUGHOUT. MAINT TEXT: SUSPECT GENERATOR MALFUNCTION. NEED BOTH ENGINE RUN TO ISOLATE SUSPECTED GENERATOR. FOUND THRESHOLD FLUORESCENT LIGHT ABOVE DOOR 1L FLICKERING, RELASDR 2008UALA04172Smoke Detector · false activationAVIONICS SMOKE ECAM DISPLAYED AFTER TAKEOFF, NO PERCEPTIBLE SMOKE DETECTED. RAN SUCCESSFUL TEST OF AEVC & RESET BOTH FLIGHT WARNING COMPUTERS (PRECAUTIONARY). INSTALLED NEW SMOKE DETECTOR 2WA. OPS CHECK SATISFACTORY.SDR 2008UALA03498Pump · failedYELLOW HYDRAULIC SYSTEM FAILURE. FLIGHT DIVERTED. NR 2 EDP FAILURE. REPLACED NR 2 ENG HYD PUMP, SERVICED HYD TO FULL, LEAKS CHECKED GOOD.SDR 2008UALA00213Control Unit · malfunctionedCREW REPORTS LANDING GEAR DID NOT RETRACT AFTER T/O. PFR SHOWS 25GA FAULT, SERVICED NOSE GEAR STRUT, REPLACED LGCIU NR 2 ACCOMPLISHED A TEST FLIGHT WITH THREE SUCCESSFUL DEPLOY AND RETRACTIONS. A/C HAS NOT HAD THIS ISSUE SINCE JAN 15, 2008.SDR 2007UALA04159Proximity Switch · faultyR AFT EMER EXIT DISPLAYED ON UPPER ECAM SCREEN. DOOR CREW COMMENTS: CABIN PRESSURE IS NORMAL. PROX SWITCH FAULTY. REPLACED PROX SWITCH HANDLE FLAP RIGHT AFT EMERGENCY EXIT DOOR 21WV2.SDR 2007UALA03767Warning Message · illuminatedLANDED UNDER AMBER ALERT DUE TO GREEN HYDRAULIC OVERHEAT ECAM MESSAGE.SDR 2007UALA02475Display · faultedADR 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. FOUND ADIRU MISALIGNED. CYCLED CB'S C2 AND F6. ALIGNED ADIRU'S AND FAULT LITE EXTINGUISHED. PERFORMED BITE CK OF ADR1 AND NO FAULTS NOTED.SDR 2007UALA02172Cylinder · unreliableFOUND DOOR 1R EMERGENCY CYLINDER IN THE UNARMED POSITION AND NOT SAFETIED. ARMED EMERGENCY CYLINDER AND SAFETIED.SDR 2006UALA02318Battery Pack · faultyDURING 3 SVC EMERGENCY LIGHT CHECK, FOUND "EPSU BATTERY EMER L" MESSAGE. REPLACED BATTERY PACK 11WL. SYSTEM CHECKED NORMAL.SDR 2006UALA01885Wire · brokenEMERGENCY LIGHT TEST, SEAT 1ABC EMERGENCY LIGHT INOPERATIVE. REPLACED WIRING HARNESS FROM SEAT TO WALL CONNECTOR.SDR 2006UALA01616Proximity Sensor · dirtyR AFT EMER EXIT DISPLAYED ON UPPER ECAM SCREEN, DOOR. CABIN PRESSURE NORMAL. SLIDE ARMED LIGHT AT EXIT DOOR IS ALSO ON. CLEANED DEBRIS FROM PROXIMITY SENSOR TARGET AND LIGHT OPERATED NORMALLY.SDR 2006UALA01398Battery Pack · failedEMERGENCY LIGHT TEST FAILS WITH MSG EPSU COMM AFT L.SDR 2006UALA01311Hydraulic System · reads lowRETURN TO FIELD DUE TO ALL HYDRAULIC QUANTITY INDICATIONS SHOWING ZERO. FOUND NO POWER AT 1834GQ IND RSVR HYD QTY AT REFILL BAY. CHECKED FOR 26VAC AT CIRCUIT BREAKER 1831GQ, NO POWER. FOUND CIRCUIT BREAKER 5XN1 BUS 1-131XP A SUPPLY POPPED ON 123VU. RESET BSDR 2006UALA00772Epsu · no testAFTER THE EMERGENCY LIGHT TEST, 'AT 33-31-38 EPSU INT LOAD EMER L' MESSAGE SHOWED ON CIDS PANEL. REPLACED EPSU AT 11WL, SYSTEM TESTS NORMAL.SDR 2006UALA00369Screw · shearedRETURN TO FIELD DUE TO A LOSS OF GREEN HYDRAULIC SYSTEM. LOSS GREEN HYD FLUID LEVEL. YELLOW AND BLUE SYS APPEARS OK. SECURED GREEN HYD SYS PER IRREG PROCEDURES. INSTALL GROUND SAFETY LOCKS PER AMM 32-00-00 AND TROUBLESHOOT. SOURCE OF GREEN HYD QTY LOSS.