N440SW
Service difficulty reports · 245
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N440SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N440SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200617307Angle · crackedFS 625 LT BL40 WL79 ANGLE CRACKED, DISCOVERED DURING C-CHECK INSPECTION. REPLACED CRACKED ANGLE AT FS 625 LT BL40 WL79 PER CRJ200 SRM 51-42-06 PG 11, 18.SDR SWIA200617306Angle · crackedFS 625 RT BL40 WL79 ANGLE CRACKED, DISCOVERED DURING C-CHECK INSPECTION. REPLACED CRACKED ANGLE AT FS 625 RT BL40 WL79 PER CRJ200 SRM 51-42-06 PG 11, 18.SDR SWIA200616933Pump · failedAT 12K FEET MSL AND ON FINAL, THE LT ENGINE QUIT. REPLACED LT ENGINE FUEL CONTROL AND FUEL PUMP IAW RII 73-401 AND AMM 73-71-01. FUEL CONTROL P/N 4147T70P02 S/N WYGA3753.SDR SWIA200616614Pcu · malfunctionedFLIGHT SPOILER OBD PCU FAILED. REPLACED LEFT OUTBOARD FLIGHT SPOILER PCU IAW 27-61-01. OPERATIONAL CHECKS OK.SDR SWIA200616620Control Unit · malfunctionedFLT SPOILER FAULT STATUS MESSAGE ON TAXI OUT. REPLACED SECU NR 1 IAW MM 27-61-05. OPERATIONAL CHECK GOOD.SDR SWIA200616208Pcu · malfunctionedLEFT SPOILERON FAULT. REPLACED LEFT SPOILERON OB PCU IAW MM 27-62-01, OPERATIONAL CHECK GOOD.SDR SWIA200515960Actuator · malfunctionedFLAPS FAIL CAUTION MESSAGE ON APPROACH. REPLACED MULTIPLE FLAP ACTUATORS IAW MM 27-53-01. OPERATIONAL CHECK GOOD.SDR SWIA200515832Sensor · malfunctionedWHEN SELECTED FLAPS FROM 0 DEGREES TO 8 DEGREES, RECEIVED "FLAPS FAIL" CAUTION MESSAGE. REPLACED SAME BRAKE POSITION SENSOR. OPERATIONAL CHECK GOOD IAW MM27-51-00.SDR SWIA200515494Actuator · malfunctionedSTAB TRIM CH 1 STATUS MESSAGE AFTER TAKEOFF. REPLACED HSTCA AND HSTMCU IAW 27-40-27. OPERATIONAL CHECK GOOD, PN 7062-3 SN/OFF 1131.SDR SWIA200515495Control System · malfunctionedON CLIMB-OUT, STAB CH 1 INOP MSG APPEARED ON ED-2. REPLACED HSTCU IAW MM 27-41-01. OPERATIONAL CHECK GOOD, PN 7060-9 SN/OFF 1076.SDR SWIA200515224Window · crackedLT COCKPIT WINDOW CRACKED DURING DESCENT. REMOVED AND INSTALLED NEW WINDSHIELD IAW MM 56-12-01, PN NP139322-5 SN OFF 02014H6536.SDR SWIA200514880Bulb · burned outFORWARD AND AFT CEILING EMERGENCY FLOOR LIGHTS INOPERATIVE. REPLACED BULBS OPERATIONAL CHECK OK.SDR SWIA200514787Pcu · malfunctionedRIGHT SPOILERON FAULT MESSAGE. REMOVED AND REPLACED RIGHT INBOARD PCU OF RIGHT SPOILERON IAW CRJ 600 MM 27-62-01, OPERATIONAL CHECK GOOD.SDR SWIA200514618Light · inoperativeEMERGENCY LIGHT BAR ABOVE GALLEY SERVICE DOOR INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BAR IAW 33-00-00, OPERATIONAL CHECK GOOD.SDR SWIA200514576Floorbeam · crackedCARGO COMPARTMENT FLOOR SUPPORT ANGLE CRACKED AT FS 621.00 RLB 42.0. ITEM FOUND AT C-CHECK INSPECTION. SUPPORT ANGLE REPAIRED IAW CRJ REO 601R-53-61-117 REV "B'.SDR SWIA200514575Support · crackedAFT EQUIPMENT COMPARTMENT NR 1 HYDRAULIC SUPPORT MANIFOLD IS CRACKED IN LOWER AFT CORNER; FS 718.00. ITEM FOUND AT C-CHECK INSPECTION. HYDRAULIC SUPPORT BRACKET REPAIRED IAW CRJ REO 601R-53-62-031 REV A/C.SDR SWIA200514574Intercostal · crackedAFT EQUIPMENT BAY INTERCOSTAL CUP IS CRACKED; FS 625.00 STR 14R. ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIP IAW CRJ SRM 51-40-11, 51-42-06, AND 51-25-16.SDR SWIA200514573Intercostal · crackedAFT EQUIPMENT BAY INTERCOSTAL CUP IS CRACKED; FS 625.00 STR 14L. ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIP IAW CRJ SRM 51-40-11, 51-42-06, AND 51-25-16.SDR SWIA200514572Web · crackedAFT EQUIPMENT BAY ESB HAS A CRACK; FS 625.00 LBL - 38.0 LOWER WEB. ITEM FOUND AT C-CHECK INSPECTION. REPAIRED LOWER WEB IAW CRJ REO 601R-53-61-358 REV A.SDR SWIA200514571Web · crackedAFT EQUIPMENT BAY ESB HAS A CRACK; FS 625.00 RBL - 38.0 LOWER WEB. ITEM FOUND AT C-CHECK INSPECTION. REPAIRED LOWER WEB IAW CRJ REO 601R-53-61-358, REV A.SDR SWIA200514570Intercostal · crackedPULLEY INTERCOSTAL ANGLE AT FS 484 LBL 27.0 CRACKED. ITEM FOUND AT C-CHECK INSPECTION. REPLACED ANGLE IAW CRJ REO 601R-53-41-059 REV A.SDR SWIA200514569Beam · crackedMAIN FUSELAGE FS 280.00 RBL 9.0 LOWER FLANGE OF TRANSVERSE BEAM CRACKED. ITEM FOUND AT C-CHECK INSPECTION. REPAIRED FS280, RBL 9 LOWER FLANGE OF TRANSVERSE BEAM IAW CRJ REO 601R-53-11-171 REV A.SDR SWIA200514568Clip · crackedMAIN FUSELAGE FS 280.00 RBL 9.0 INBOARD CLIP CRACKED. ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIP IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, AND 51-23-00.SDR SWIA200514567Clip · crackedMAIN FUSELAGE FS 280.00 LBL 9.0 OUTBOARD CLIP CRACKED. ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIP IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-23-00.SDR SWIA200414099Pcu · malfunctionedSPOILERON FAULT STATUS MESSAGE DURING TAXI OUT. REMOVED AND REPLACED THE RIGHT SPOILERON OUTBOARD PCU IAW MM 27-62-01. OPERATIONAL CHECK GOOD.SDR SWIA200414031Smoke Detector · malfunctionedIN CRUISE AT FL 330, SMOKE CARGO MESSAGE DIVERTED TO COS, FIRED BOTTLES IN CARGO BAY. REMOVED AND REPLACED LEFT AND RIGHT CARGO FIRE BOTTLES; REPLACED BOTH FORWARD AND AFT SMOKE DETECTORS IAW 26-15-01. OPERATIONAL CHECK GOOD. P/N 36500018-3, S/N OFF 4274801SDR SWIA200413945Trim Switch · malfunctionedCAPTAINS SIDE TRIM SWITCH STICKS. REMOVED AND REPLACED PITCH TRIM SWITCH (CAPTAINS SIDE) WITH SERVICEABLE UNIT IAW CRJ MM 27-41-05. OPERATIONAL CHECK GOOD.SDR SWIA200413759Apu · smokeFOLLOWING APU START, RECEIVED A (CARGO SMOKE) WARNING AND AURAL MESSAGE MOMENATARILY. INSPECTED APU ASSEMBLY AND DUCTING FOR LEAKS. STARTED APU SEVERAL TIMES WITH NO ANNOUNCED INDICATIONS, OPERATIONAL CHECK GOOD.SDR SWIA200413597Actuator · malfunctionedHSTCU FAULTS IN MDC. REMOVED AND REPLACED HORIZONTAL STAB TRIM ACTUATOR IAW AMM 27-42-01 AND HORIZONTAL STAB TRIM MOTOR CONTROL UNIT IAW AMM 27-42-05, OPERATIONAL CHECK GOOD. HSTCU P/N 7062-3, S/N OFF 831.SDR SWIA200413393Pcu · malfunctionedSPOILERON FAULT STATUS MESSAGE AFTER TAKEOFF. REMOVED AND REPLACED INBOARD SPOILERON PCU IAW 27-62-01. OPERATIONAL CHECK GOOD.SDR SWIA200413368Smoke Detector · malfunctionedUPON INITIAL POWER UP OF AIRCRAFT, THE CARGO FIREX PANEL INDICATED SMOKE CARGO. BOTH RED LIGHTS ILLUMINATED WITHOUT BOTTLE ARMED LIGHTS ILLUMINATING. REPLACED BOTH NR 1 AND NR 2 SMOKE DETECTORS IN THE CARGO COMP. SYSTEM OPS CHECKS GOOD. P/N: 473597-19, S/NSDR SWIA200312279Floor Support · crackedCARGO PIT FLOOR SUPPORT ANGLE CRACKED AT FS 621.0, LBL 38.0. DISCOVERED DURING C-CHECK, REPAIRED DAMAGE IAW CRJ REO 601R-53-61-117 REV ''A''. ANGLE P/N: 601R-53-61-117-1SDR SWIA200312278Clip · crackedAFT FUSELAGE, CLIP CRACKED AT FS 625.0; STR 14R. DISCOVERED DURING C-CHECK, CLIP REPLACED IAW CRJ SRM 51-42-06. P/N: 601-35012-52SDR SWIA200312277Intercostal · crackedMID FUSELAGE, PULLEY INTERCOSTAL OB FLANGE IS CRACKED; FS 484.0, LBL 36.0. DISCOVERED DURING C-CHECK, CUT OUT DAMAGE IAW CRJ REO 601R-53-41-059 ''A''. REPAIRED ANGLE IAW CRJ REO 601R-53-41-059 ''A'' & RII 53-401.SDR SWIA200312276Clip · crackedFLOORBEAM CLIP CRACKED AT FS 280.00; RBL 9.0 OUTBOARD. DISCOVERED DURING C-CHECK, CLIP REPLACED IAW CRJ SRM 51-42-06. P/N 601R31113-58SDR SWIA200311815Pcu · malfunctionedSPOILERONS FAULT MESSAGE. REPLACED RIGHT SPOILERON OUTBOARD PCU IAW CRJ MAMM 27-62-01. OPS AND LEAK CHECKS OK.SDR SWIA200311786Actuator · malfunctionedSTAB TRIM CH 1 WILL NOT STAY ENGAGED. REMOVED AND REPLACED STAB TRIM ACTUATOR IAW MM 27-42-01. REMOVED AND REPLACED STAB TRIM MCU IAW MM 27-42-05. OPS CHECK GOOD. STAB TRIM ACTUATOR P/N: 8396-3, S/N OFF: 816.SDR SWIA200211447Shutoff Valve · malfunctionedBLEED AIR WILL NOT SWITCH FROM APU TO ENGINE BLEED AIR IN FLIGHT, THEN VERY HARD TO GET BACK ON APU BLEED. RETURNED TO SLC. REMOVED AND REPLACED APU LOAD CONTROL VALVE IAW MM 49-51-01. RAN APU AND LT AND RT ENGINES. ALL OPS CHECKS GOOD AT THIS TIME.SDR SWIA200211437Windshield · failedRT WINDSHIELD FAILED (OUTER PANEL SHATTERED) DURING CLIMBOUT. REMOVED AND REPLACED RT SIDE WINDSHIELD IAW RJ MM 56-11-01.SDR SWIA200211464Handle · malfunctionedLANDING GEAR WOULD NOT RETRACT. REMOVED AND REPLACED LANDING GEAR HANDLE IAW CRJ MM 32-31-01. OPS CHECK GOOD. PN OFF/ON 601R50967-9 SN OFF 0712.SDR SWIA200210846Pin · brokenABORTED THE TAKEOFF DUE TO AN AMBER CAUTION IDG 2 MESSAGE ON THE EICAS AND IDG 2 FAULT ON THE OVERHEAD PANEL. INSPECTED IDG 2 & FOUND ELECTRICAL CONNECTOR FOR TEMP BULB HAS A BROKEN PIN. INSTALLED NEW PIN ON CONNECTOR & RESECURED CANNON PLUGS. RAN RIGHT ENGSDR SWIA200210581Window · crackedCAPTAIN'S SIDE WINDOW SHATTERED ON TAXI OUT. REMOVED AND REPLACED LEFT WINDOW IAW 56-12-01.SDR SWIA200110501Circuit Board · defectiveYD2 INOP STATUS MSG CYCLED ON & OFF DURING DESCENT. REMOVED AND REPLACED BOTH LHP4001 IAW CRJ MM 22-13-03. OPS CHECKS GOOD.SDR SWIA200110502Anti-Ice Valve · failedRIGHT COWL ANTI-ICE CAUTION WOULD NOT EXTINGUISH WITH COWL ANTI-ICE TURNED ON. REMOVED RIGHT ENGINE COWL ANTI-ICE VALVE AND INSTALLED A SERVICEABLE VALVE. OPERATIONAL CHECK GOOD.SDR SWIA200110477Damper · failedYAW DAMPER 2 INOP. REMOVE AND REPLACE YAW DAMPER NR 2. OPS CHECK GOOD AT THIS TIME IAW 22-22-01.
Back to N440SW