N441UP
Service difficulty reports · 145
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N441UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N441UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2022091086091Shear Web · corrodedINSPECTION TYPE:SEG3MCC LEFT UNDER FLOOR PANEL 221 XAF HAS VARIOUS AREAS OF CORROSION. THE CORROSION IS ON THE SHEAR WEB STA 395 LBL 35.00 AND LBL 45.50.BLENDOUT WAS FOUND TO BE IN LIMITS PER SRM 53-10-51-1A-2.SDR IPXA2022091086088Shear Web · corrodedINSPECTION TYPE:SEG3MAIN CABIN FLOOR STA 394 LBL 38, FLOOR HAS CORROSION. *CORROSION WAS FOUND AT THE SHEAR WEB FROM STA 365 TO STA 395 LBL 38WORKED PER RCD 283541, BLEND OUT AREA FOUND TO BE WITHIN LIMITS PER SRM 53-10-51-1A-2SDR IPXA2022091086095Shear Web · corrodedINSPECTION TYPE:SEG3MAIN CABIN FLOOR STA 360-380 RBL 40 TO RBL 45.50, HAS CORROSION. CORROSION LOCATED AT THE SHEAR WEB BETWEEN STA 365.00 AND STA 395 RBL 40.00 TO RBL 45.50AFTER THE BLENDOUT ALL AREAS, SHEAR WEB WAS FOUND TO BE IN LIMITS PER SRM 53-10-51-1A-2SDR IPXA2022090986070Deck Plate · corrodedINSPECTION TYPE:SEG3MAIN CABIN DECK AFT SHEAR PLATE AT FS1700 BL 0 REMOVED CORROSED AREA 2.00" BY 1.50" WITH ONLY .037" OF MATERIAL REMAINING FINDING DECK PLATE TO BE OUT OF LIMITS PER SRM 53-0-51-1A-AREPAIRED DECKPLATE PER SRM 53-60-51-2R-7 REPAIR 7SDR IPXA2022090886040Skin · corrodedINSPECTION TYPE:SEG3#2 ENIGNE O/B SKIN ASSY P/N 311N5046-52 HAS CORROSION AT PP STA 144.425 AND PP STA 153.90REPAIRED O/B SKIN PER EA# 757-5450-27-A3019SDR IPXA2022090886039Shear Web · crackedINSPECTION TYPE:SEG3MAIN CABIN SHEAR WEB AT FS 365.25 LBL 12.5 HAD MULTIPLE CRACK DAMAGESREPAIRED SHEAR WEB PER SRM 53-10-51-2R-12 DETAIL 2SDR IPXA2022090685940Skin · crackedINSPECTION TYPE:SEG3LEFT WING FIXED LEADING EDGE AREA BETWEEN SLAT #3 AND SLAT #4 IS CRACKEDREPAIRED PER EO #B757-5740-11855E WING-OUTBOARD FIXED LEADING EDGE UPPER SKIN PANEL CRACK REPAIRS (SREO) APPENDIX BSDR IPXA2022090285838Frame · inoperativeINSPECTION TYPE:SEG3DURING THE ACCOMPLISHMENT OF EO B757-5310-73926-A, FOUND AN EXISTING FRAME REPAIR AT STA 1460 L/HWORKED PER UPS EO B757-5310-26417-C, UPS RCD 283298 AND VT MAE 757-5360-27-A3013 REVSDR IPXA2022090285837Frame · inoperativeINSPECTION TYPE:SEG3DURING THE ACCOMPLISHMENT OF EO B757-5310-73926-A, FOUND AN EXISTING FRAME REPAIR AT STA 1480 R/HWORKED PER UPS EO B757-5310-33378-B, UPS RCD 283299 AND VT MAE 757-5360-27-A3014 REVSDR IPXA2022090185810Floor Skin · crackedINSPECTION TYPE:SEG3MAIN CARGO FLOOR PANEL # 232XQF CRACKEDFABBED PANEL 232XQF FROM 5024N400001SS-G, BATCH# 3489461 PER SREO B757-5320-9692-KSDR IPXA2022091286142Support · crackedINSPECTION TYPE:C15NO 2 ENGINE I/B TR UPPER SEAL RETAINER CRACKED. CRACKED AREA FOUND AT THE UPPER BIFURCATION FIREWALL SEAL SUPPORT INNER FLANGE PPS 139.5ACCOMPLISHED REPAIR PER RR RB211-535E4-37/10 EM: 78-31-28-300-086 AND VT MAE EA# 757-7831-27-A3020 REV-SDR IPXA2022082985706Floor Panel · damagedINSPECTION TYPE:C15CABIN FLOOR PANEL #231XCF BROKEN AT THE CORNER DOT 70.25FABBED PANEL 231XCF FROM 5024N400001SS-G, BATCH# 3489461 PER SR EO B757-5320-9692-KSDR IPXA2022090886049Floor Panel · damagedINSPECTION TYPE:C15, MAIN CARGO COMPARTMENT , FLOOR PANEL #232XFF DAMAGED. - THIS IS A MINOR REPAIRREPLACED BROKEN INSERT I.A.W. UPS E.O. NO: M-5320-38342-C. ORIG SUB DATE: 9/9/2022SDR IPXA2022091086089Shear Web · corrodedINSPECTION TYPE:SEG3MAIN CABIN STA 340 LBL 10, FLOOR HAS CORROSION IN SEVERAL AREAS. CORROSION WAS FOUND AT THE SHEAR WEB.WORKED PER RCD 283543, BLENDED OUT AREA FOUND TO BE WITHIN LIMITS PER SRM 53-10-51-1A-2.SDR IPXA2022091286144Shear Web · corrodedINSPECTION TYPE:C15MAIN CABIN FLOOR STA 345, LBL 6 HAS CORROSION. CORROSION AREA IS LOCATED AT SHEAR WEB STA 345 LBL 6AFTER BLENDOUT THE AREA FOUND TO BE WITHIN ALLOWABLE LIMITS PER SRM 53-10-51-1A-2SDR IPXA2022091286145Deck Plate · corrodedINSPECTION TYPE:C15MAIN CABIN STA 1720 LBL 17 CORROSION LOCATED AT AFT SHEAR WEB CORROSION LOCATED AT STA 1720 BETWEEN BL 0 AND LBL 24.75BLEND WAS FOUND TO BE WITHIN ALLOWABLE LIMITS PER SRM 53-60-51-1A-1SDR IPXA2020111462365Skin · delaminatedINSPECTION TYPE: SEG RT WING OUTBOARD FLAP UPPER SURFACE DISBONDED ON THE TRAILING EDGE. REPAIRED IAW SRM B757 51-70-07-OG, PER SRM 57-53-01-2R-1 250 DEGREES AT 90 MINS.SDR IPXA2020111462364Skin · delaminatedINSPECTION TYPE: SEG RT WING OUTBOARD UPPER SURFACE DISBOND ON THE TRAILING EDGE. REPAIRED IAW SRM B757 51-70-07-OG, PER SRM 57-53-01-2R-1 250 DEGREES AT 90 MINS.SDR IPXA2020111362345Stringer · bentINSPECTION TYPE: N/A IN AFT CARGO ON LT SIDE UNDER TOP DUMP VALVE STRINGER BENT IN 2 PLACES AND CRACKED IN 1 BEND, REF NRC 178310. REPAIRED DAMAGED STRINGER SECTION AT S-2OL BETWEEN STA 1400&1420, IAW B757 SRM 53-00-03-2R-1, PER SRM 53-60-03-2R.SDR IPXA2020111262300Stringer · crackedINSPECTION TYPE: SEG STRINGER 20L BETWEEN STA 1400-1420 BENT CRACKED. REPAIRED IAW SRM 53-00-03-2R-1.SDR IPXA2020081459034Unknown · odorINSPECTION TYPE:N/AATB- STRONG BURNING PLASTIC ODOR IRRELEVENT OF PACK POSITION.PERFORMED INSPECTION IAW AMM 05-51-56-202-001 AND FIM 21-00-01-301. COULD NOT DUPLICATE SMELL. A/C OK FOR SERVICESDR IPXA2020072458184Fan · failedAFTER TAKE OFF, EQUIPMENT COOLING, OVERHEAT LIGHT IN THE ALTERNATE POS. DU TO FANS NR 1. FOLLOWED BY F/O LOSING FD, SWITCHED TO SOURCE C CENTER THEN EQUIPMENT COOLING SUPPLY FAN NR 2, CIRTCUT BREAKER TRIPPED STATUS MESSAGE EQUIP CLG FLOW, EQUIP CLG, REMOVED ASDR IPXA2020070657369Power Supply · inoperativeINSPECTION TYPE:N/A EMERGENCY LIGHT OVER L1 DOOR DOES NOT STAY ON. REMOVED AN REPLACED POWER SUPPLY ON LIGHT OVER L1 DOOR REF AMM 33-51-07-862-059 AN 33-51-07-022-000, OPS CHECK GOOD.SDR IPXA2020032553558Unknown · odorINSPECTION TYPE:N/A** SUPPLEMENTAL SDR ** BURNING SMELL IN COCKPIT WITH JUST THE LEFT PACK OPERATING. SWITCHED TO THE RIGHT PACK (LEFT PACK OFF) - SMELL DISSIPATED. DEFERRED PER MEL 21-51-1 L/H PACK CNTRL NO. M 702700. PLACARD INSTALLED. NO DMP.OPERATED LEFT PSDR IPXA2020021435087Relay · failedINSPECTION TYPE:N/AON DESCENT STRONG SMELL OBSERVED SIMILAR ILLEGIBLE ELECTRIC SMELL OR DIRTY SOCK. SAME SMELL WITH EITHER R OR L PACK OFFRAN PACK FOR SEVERAL MINUTES NO HELP. VISUALLY INSPECTED RECIR-FAN DISCREPANCIES FOUND WO 0559168 02-12-20. REPLACED 415 RSDR IPXA2017101922784Cover · brokenCAPTAIN`S EMERGENCY ESCAPE ROPE COVER IS BROKEN. REPAIRED THE ESCAPE ROPE COVER IAW DRAWING 232N1714.SDR IPXA2017070719033Altimeter · malfunctionedINSPECTION TYPE: PS-10140Z, BLOCK TURN BACK TO AFTER COMPLETING THE LEFT ENGINE START THE LEFT A/S IN, ALTIMETER, VSI ALL WENT INOP, ALONG WITH LEFT TRASPONDER. SWITCHING TO ALT POS ON AIR DATA CORRECTED PROBLEM. AFTER BLOCKIN AND SWITCH TO APU ALL INSTUMENSDR IPXA2017042116347Bulb · inoperativeEMERGENCY LIGHT ASSY HAS THREE INOPERATIVE BULBS. REPLACED THEBULBS IAW AMM 33-51-01-2.SDR IPXA2016110210188Floor Panel · delaminatedINSPECTION TYPE: SEG4, MCD FLOOR PANEL 231XJF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016110210187Floor Panel · delaminatedINSPECTION TYPE: SEG4, MCD FLOOR PANEL 231XFF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-530-9692-H.SDR IPXA2016102809977Floor Panel · damagedINSPECTION TYPE: CM, CARGO DECK FLOOR PANEL 242XKF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016102809976Floor Panel · damagedINSPECTION TYPE: CM, CARGO DECK FLOOR PANEL 242XLF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016102809975Floor Panel · damagedINSPECTION TYPE: CM, CARGO DECK FLOOR PANEL 242XMF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015090293034Control Panel · damagedEMERGENCY LIGHTS GUARD WILL NOT STAY IN GUARDED POSITION. R & R EMERGENCY LIGHTS CONTROL PANEL IAW AMM 33-51-08-404-011. OPS CHECKED GOOD EFF SOURCE, REF: IPC 33-51-08-04, ITEM 005.SDR IPXA2015020285518Floor Panel · delaminatedINSPECTION TYPE: C11, DELAMINATED FLOOR PANEL 231XHF. FABRICATED A NEW FLOOR PANELSDR IPXA2015013085477Floorboard · delaminatedINSPECTION TYPE: C11, DELAMINATED FLOORBOARD 252XUF. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692HSDR IPXA2015013085478Floor Panel · crackedINSPECTION TYPE: C1, 1 FLOOR PANEL 211XAF IS CRACKED AND DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012685441Tee Fitting · corrodedINSPECTION TYPE: C 11, BS 324 LT OTBD SIDE AT CUSP TEE FITTING IS CORRODED IN SPOTS APPROX 8 INCHES GOING AFT. REPAIRED AREA IAW EO 5340-56458-A.SDR IPXA2015020285525Skin · dentedINSPECTION TYPE: C11, BS 228 S23L SKIN DENTED JUST FWD OF FRAME. PERFORMED SKIN REPAIR IAW SRM 53-00-01-2R, REPAIR 3 AND REO-G18703, REV A.SDR IPXA2014012981672Battery Pack · inoperativeEMERGENCY EXIT LIGHT FAILED TO ILLUMINATE DURING TEST. R & R BATTERY PACK IAW AMM 33-51-07-702-001.SDR IPXA2014010201192Bulb · inoperativeEMERGENCY LIGHT ASSY HAS THREE INOPERATIVE BULBS. REPLACED BULBS IAW AMM 33-51-01-2.SDR IPXA2013111100816Skin · dentedRT INBD MID FLAP T/E WEDGE TOP SKIN DENTED. REPAIRED IAW EO B757-5750-52666-A. REPAIR COMPLETED IAW EO B757-5750-52666A. MAJOR REPAIR.SDR IPXA3577648Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 241XHF HAS DAMAGED CORNER. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577647Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 241XFF HAS EDGE AND CORNER DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577645Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 242XDF HAS DAMAGED CORNER. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577644Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 241XJF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577638Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 242XEF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SAMPLE IAW EO B757-5320-96 92-H.SDR IPXA3577643Floorboard · damagedINSPECTION TYPE:S2C1 FLOORBOARD 242XCF EDGES DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577642Floorboard · damagedINSPECTION TYPE:S2C1, FLOORBOARD 242XAF EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577641Floorboard · damagedINSPECTION TYPE:S2C1, FLOORBOARD 241XAF EDGE DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.
Back to N441UP