N44503
Service difficulty reports · 61
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N44503' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N44503' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20140914003A/C Pack · overheatedBOTH LT & RT PACK TRIPPED OFF & LOSS OF CABIN PRESS. EMER DECLARED FLIGHT DIVERTED & LANDED WITHOUT INCIDENT. ACCOMPLISHED MCM CARD 21-95-11 WITH NO FAULTS NOTED. BOTH CABIN PRESS CONTROLLERS BITE CHECKED GOOD. ACFT HOLDS CABIN PRESS WITH NO AIR LEAKS NOTESDR AALA20140804009Controller · inoperativeNUMBER 2 CABIN PRESS CONTROLLER INOPERATIVE WITH NR 1 CONTROLLER ON PLACARD. FLIGHT RETURNED & LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. REPLACED NR 2 CABIN PRESS CONTROLLER. SYS GND CHECKED NORMAL OPERATION CLOSED.SDR AALA20140701006Stop Fitting · crackedFORWARD CARGO DOOR, FWD LOWER DOOR STOP CASTING IS CRACKED. INSTALLED NEW STOP PAD FITTING.SDR AALA20140610024Rib · crackedNUMBER 4 SLAT TRACK LEADING INBD SUPPORT RIB CRACKED. ACCOMPLISHED REPAIR IAW EA MD80-57-035265.SDR AALA20140610023Rib · crackedNUMBER 4 SLAT TRACK LEADING INBD SUPPORT RIB CRACKED. ACCOMPLISHED REPAIR IAW EA MD80-57-035265.SDR AALA20140407002Battery Pack · dischargedEMERGENCY LIGHT AT FWD OVERWING EXIT INOPERATIVE. R & R BATTERY PACK B-103, OPERATIONS CHECKED NORMAL.SDR AALA20140407001Battery Pack · dischargedBATTERY PACK AB 5 - 4 FAILED CHECK. R & R BATTERY PACK, OPERATIONS CHECKED NORMAL.SDR AALA20130424009Cusp Web · corrodedCORROSION ON RIGHT CUSP AT STATION 560. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20130104010Cusp Web · damagedHOLE IN CUSP UNDER NUMBER 6 SEAT TRACK AT STATION 266. INSTALLED REPAIR DOUBLER PER AARD 53-20-00-16.SDR AALA20130104009Threshold · corrodedHEAVY CORROSION ON FORWARD SERVICE DOOR AFT THRESHOLD AREA, STATION 200, RIGHT BUTTLINE 54. REMOVED DAMAGE AND INSTALLED DOUBLER AND FILLER PER AARD 53-20-00-14.SDR AALA20130104008Web · corrodedCORROSION ON SUBFLOOR AT STATION 198, RIGHT BUTTLINE 55. INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20121215002Skin · dentedDENT AT STATION 160, LONGERON 20 RIGHT. INSTALLED REPAIR DOUBLER PER SRM 53-04-03.SDR AALA20121212024Longeron · crackedCRACK AT LONGERON 2 LEFT, STATION 160, ON OUTBOARD SIDE. INSTALLED NEW SECTION AND SPLICE AT LONGERON 2 LEFT FROM STATIONS 148 TO 175 PER SRM 53-02-00 FIGURE 18.SDR AALA20121212022Web · corrodedCORROSION ON WEB BETWEEN STATIONS 1149 TO 1155 BETWEEN LONGERONS 25 AND 27 RIGHT. REMOVED DAMAGE AND INSTALLED SPLICE REPAIR PER AARD 53-10-00-24.SDR AALA20121212006Membrane · gougedSTATION 200, RIGHT BUTTLINE 6, GOUGE IN SUBFLOOR. REMOVED DAMAGED AREA IN SUBFLOOR AND INSTALLED DOUBLER REPAIR AS AARD 53-20-00-16.SDR AALA20121212005Fitting · corrodedSTATION 160, GALLEY NUMBER 1 TIE DOWN FITTING CORRODED. INSTALLED SERVICEABLE TIE DOWN FITTING PER AARD 51-00-05-1.SDR AALA20121211017Stiffener · crackedSTIFFENER CRACKED BELOW LONGERON 1 ABOVE VAULT DOOR JAMB. INSTALLED DOUBLER PER AARD 53-10-00-15.SDR AALA20121211004Cusp Web · corrodedRIGHT CUSP FROM STATIONS 1165 TO 1170 CORRODED. REMOVED CORROSION AND INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20121210001Angle · crackedSTATION 237, FORWARD CARGO, ANGLE CRACKED BELOW LEFT TIE DOWN TRACK, FORWARD SIDE OF FRAME. REMOVED CRACKED ANGLE AND INSTALLED SERVICEABLE ANGLE PER AARD 51-00-05-1.SDR AALA20121207023Door Frame · crackedFORWARD CARGO DOOR FORWARD PAN FRAME CRACKED AT NUMBER 1 BEAM RADIUS BLOCK. INSTALLED DOUBLER PER EA COMP-52-027430.SDR AALA20121207022Door Frame · crackedAFT CARGO DOOR FORWARD PAN FRAME CRACKED AT NUMBER 5 BEAM. STOP DRILLED CRACK AND INSTALLED DOUBLER PER ESO80174 AND SRM 52-03-00 FIGURE 8.SDR AALA20121207021Structure · damagedFOUND COMPOSITE DAMAGE ON RUDDER WHEN SANDING. DAMAGE AND REPAIR IS LOCATED ON THE RIGHT SIDE OF RUDDER. APPLIED WET OVERLAYS TO REPAIR AREA PER SRM 51-90-00.SDR AALA20121207007Door Frame · crackedFORWARD CARGO DOOR AFT PAN FRAME CRACKED AT NUMBER 5 BEAM. STOP DRILLED CRACK AND INSTALLED REPAIR DOUBLER PER SRM 52-03-00 FIGURE 8.SDR AALA20121207006Stiffener · crackedSTIFFENER AT AFT VAULT DOOR LEFT JAMB BETWEEN LATCH LUG CUTOUTS CRACKED. REPLACED WITH NEW STIFFENER PER AARD 51-00-05-1.SDR AALA20121205010Gusset · crackedCRACK AT LEFT GUSSET, STATION 207, LONGERON 11 LEFT. INSTALLED DOUBLER PER AARD 53-10-00-11.SDR AALA20130104015Skin · crackedCRACK IN FUSELAGE AT RIVET AT FRAME STATION 165.5 AND LONGERON 22 LEFT. INSTALLED DOUBLER PER BOEING DRAWING SR09530219.SDR AALA20110316DFW03Control Unit · inoperativeDFW - CREW REPORTED ON APPROACH AFTER GEAR EXTENSION, ALL AUTOSKID LIGHTS REMAINED ILLUMINATED. ACCOMPLISHED GO AROUND AND PERFORMED QRH PROCEDURES ON SECOND APPROACH ALL INDICATIONS WERE NORMAL. REPLACED ANTI-SKID CONTROL UNIT. SYSTEM GROUND CHECK NORMAL OSDR AALA20100608DFW01Mechanism · out of adjustDFW CREW REPORTED GEAR WOULD NOT RETRACT. EMERGENCY DECLARED RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. INSPECTION FOUND GROUND SENSE MECHANISM OUT OF ADJUSTMENT ACCOMPLISHED RIG AND TEST OF GROUND SENSE CONTROL MECHANISM PER MMSDR AALA20091104LGA01Battery Pack · dischargedEMERGENCY LIGHT AT SEAT ROWS 20 TO 32 INOPERATIVE. REPLACED BATTERY PACK.SDR AALA2009060400004Battery Pack · dischargedDFW - CEILING EMERGENCY LIGHTS IN FIRST CLASS INOPERATIVE. REPLACED BATTERY PACK FOR CEILING EMERGENCY LIGHTS IN FIRST CLASS.SDR AALA2009060400003Battery Pack · dischargedDFW - FORWARD EMERGENCY EXIT SIGNS ABOVE OVERWING EXITS INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD EMERGENCY EXIT SIGNS.SDR AALA2009032300636Battery Pack · dischargedPHL - EMERGENCY LIGHTS DID NOT PASS TEST. REPLACED BATTERY PACK.SDR AALA20072390Seal · brokenLGA - EMERGENCY FLASHLIGHT SECURITY SEAL AT LEFT NUMBER ONE DOOR BROKEN. REPLACED SECURITY SEAL FOR EMERGENCY FLASHLIGHT AT LEFT NUMBER ONE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20071118Battery Pack · inoperativeLGA - OVERHEAD EMERGENCY EXIT LIGHT AT SEAT ROWS 3 TO 8 INOPERATIVE. REPLACED BATTERY PACK FOR OVERHEAD EMERGENCY EXIT LIGHT AT SEAT ROWS 3 TO 8. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060284Bungee Cylinder · inoperativeDFW - NOSE LANDING GEAR DID NOT EXTEND ON FINAL. AFTER GO AROUND NOSE LANDING GEAR EXTENDED WITH EMERGENCY GEAR EXTENSION HANDLE. LANDED DFW WITHOUT INCIDENT. REPLACED NOSE LANDING GEAR STRUT AND REPLACED NOSE LANDING GEAR BUNGEE ACTUATOR. SYSTEM GROUND CHSDR AALA20021823Flashlight · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PORTABLE FLASHLIGHT INOPERATIVE. REPLACED EMERGENCY EXIT FLASHLIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20020317Line · leakingDFW - FLT 1954 - AFTER TAKEOFF DFW, RETURNED TO DFW DUE TO SMOKE AND BURNING RUBBER SMELL IN CABIN. LANDED DFW OVERWEIGHT WITHOUT INCIDENT. TIGHTENED APU OIL COOLER LINE. ACCOMPLISHED PACK BURN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20001808Frame · crackedTUL - FOUND CANT FRAME 1485 HAS A CRACK ON LOWER END RIGHT SIDE. CUT AND REPLACED CRACKED CANT FRAME 1485 PER FSO 80559 DATED 10-24-00. (M)SDR AALA20001805Seat Track · corrodedTUL - FOUND CORROSION ON NR 2 SEAT TRACK STATION 1193-1309. REPLACED SEAT TRACK STATION 1174-1309 PER SRM 51-01. (M)SDR AALA20001802Seat Track · corrodedTUL - FOUND SEAT TRACK NR 1 AT GALLEY TIE DOWN CORROSION 1 INCH BY 2 INCHES OUT OF LIMITS, NEED CHANGE NEW SEAT TRACK NR 1 FROM STATION 1174-1309. INSTALLED NEW SECTION OF SEAT TRACK FROM STATION 1174-1309 PER SRM 51-01. (M)SDR AALA20001801Seat Track · wornTUL - FOUND SEAT TRACK NR 4 IS WORN 6 INCHES BY 3 INCHES, STATION 934. INSTALLED 1 NEW SEAT TRACK PLUG PER SRM 53-30-00-10. (M)SDR AALA20001806Intercostal · corrodedTUL - FOUND INTERCOSTAL CORRODED 1 INCH BY 13 INCHES, ALONG UPPER OUTBOARD EDGE STATION 1309-1322 BETWEEN STRINGER 27L AND 28L. REPLACED INTERCOSTAL PER SRM 51-01. (M)SDR AALA20001797Seat Track · corrodedTUL - FOUND STATION 1155 PLUS 12 INCHES SEAT TRACK NR 3, CORROSION AT 390 NUTPLATES. REPLACED SEAT TRACK NR 3 FROM STATION NR 1030 TO STATION 1309 PER SRM 53-05 FIG 4F. (M)SDR AALA20001796Seat Track · corrodedTUL - FOUND INBOARD FLANGE CORRODED 1 INCH BY 1 INCH, AT NUTPLATES. REPLACED NR 3 SEAT TRACK FROM STATION 1030 TO 1309 PER SRM 53-05 FIG 4F. (M)SDR AALA20001795Seat Track · corrodedTUL - FOUND SEAT TRACK CORRODED 1 INCH BY 1 INCH, STATION 1124. REPLACED NR 3 SEAT TRACK STATION 1030 TO 1309 PER SRM 53-05 FIG 4F. (M)SDR AALA20001794Seat Track · corrodedTUL - FOUND SEAT TRACK CORRODED 1 INCH BY 1 INCH, STATION 1231. REPLACED NR 3 SEAT TRACK FROM STATION 1030 TO 1309 PER 53-05 FIG 4F. (M)SDR AALA20001793Skin · dentedTUL - FOUND SKIN DENTED BETWEEN LONGERON 18 AND 19 LEFT AND JUST ABOVE LONGERON 20L. COLD WORKED DENTS OUT PER SRM 53-04 AND INSTALLED DOUBLER PER SRM 53-04 FIG 12B AND ESO 80559 DATED 10-13-2000. (M)SDR AALA20001792Skin · dentedTUL - FOUND DENT 3 INCH BY 5 INCH IN FUSELAGE RIGHT STATION 465, BETWEEN L21R AND 22R. INSTALLED DOUBLER PER SRM 53-04 FIG 12. (M)SDR AALA20001788Seat Track · corrodedTUL - FOUND SEAT TRACK NR 3 STATION NR 1193 PLUS 8 INCHES SEAT TRACK CORRODED. REPLACED NR 3 SEAT TRACK FROM STATION NR 1030 TO STATION 1309 PER SRM 53-05 FIG 4F. (M)SDR AALA20001791Seat Track · corrodedTUL - FOUND SEAT TRACK NR 6 HAS CORROSION AT STATION 733. INSTALLED 1 NEW SEAT TRACK PLUG PER SRM 53-20-00-10. (M)
Back to N44503