N450PA
Service difficulty reports · 307
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N450PA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N450PA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR P5CA0300909Indicator · inoperativeNR 4 ENG OIL PRESSURE INDICATION FAILED AFTER ENG START. RE-PINNED BRKN AND WIRE AT DT679 PIN A. ALSO REMOVED AND REPLACED INOP OIL TRANSMITTER.SDR P5CA0300901Start Valve · malfunctionedENG NR 2 WOULD NOT START EICAS MESSAGE -ENG NR 2 START VLV-. DEFERRED NR 2 ENG PER DDG START VLV REQUIRED MANUAL START.SDR P5CA0300805Pedal · displacedWITH RUDDER SURFACES NEUTRAL RUDDER PEDALS WERE DISPLACED 1-8 UNITS (RIGHT). OPERATIONAL CHECKED PER AMM 27-21-00. OPS CHECK NORMAL. SUSPECT LARGE LATERAL IMBALANCE AS INDICATED ON W/B FORMS.SDR P5CA0300719Rudder · malfunctionedRUDDER TRAVEL NOT GOING TO LIMITS ON R/H INDICATOR DURING CONTROL CHECK. INSPECTED FWD & AFT RUDDER QUADRANT ASSYS, CABLE SYS., TRIM, CENTERING & FEEL MECHANISM PER MM 27-21-06, 27-21-08 & 27-21-11. ALL OK. PULLED A/C INTO HANGAR. AFTER 30 MIN. SYSTEM OPS CHECSDR P5CA0401022Warning Light · illuminatedBLEED OVERHEAT / PRU EICAS MESSAGE NNC 2.3. GROUND TESTED PER MM 36-11-00 TEST PASSED. NO MESSAGE FOUND ON EICAS WHEN RETURNED TO BLOCKS.SDR P5CA0200659Smoke Detector · contaminatedCENTER FIRE SENSORS ON MAIN DECK INDICATED FIRE 9 HRS INTO FLT. VISUAL INSPECTION REVEALED NO FIRE. CB'S PULLED TO SILENCE ALARM FOR DURATION OF FLT & PERFORMED PERIODIC VISUAL FIRE INSPECTION. CLEANED & DRIED MAIN DECK SMOKE DETECTOR. (DETECTOR CONTAMINATED DSDR P5CA0200625Nozzle · cracked#3 ENGINE EXHAUST NOZZLE OUTER SKIN IS CRACKED ON THE RIGHT SIDE TOP. REMOVED & REPLACED EXHAUST NOZZLE AS PER 78-11-01.
Back to N450PA