N455UA
Service difficulty reports · 173
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N455UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N455UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017121904534Power Supply · faultyWHILE PERFORMING EMER LIGHT BAT TEST, RECEIVED "EPSU EXT LOAD EMER R". T/S TO EPSU. RMVD BOTH OVERWING EXIT EPSU BAT AND RESET. SWAPPED AND EXT LIGHT FAULT FOLLOWED ESPU. RPLD RIGHT OVERWING ESPU SYSTEM CHKS GOOD. REF TSM 33-51-00,AMM 33-51-38, 25-62-42.SDR CALA2017121804519Power Supply · faultyDURING EMER LIGHTS CHECK FOR A3, FOUND LH EMER BAT FAULTING ON UNIT. REPLACED LH EMER LIGHT PWR SPPLY UNIT PER AMM 33-51-38SDR CALA2017072802425Light · failedCABIN EMER LIGHTS TEST FAILED. FAULT READS "EPSU RT EXTERNAL LOAD". BIT TEST EPSU RT, UNABLE TO RUN TEST. EPSU NOT POWER UP. RELAMPED OVER WING EMER LIGHTS ON RT WING FAIRING(2 EA.). RE-SEATED BATTERY PACK AND ACPD EMER LIGHTS TEST. OP CKS GOOD. EMER LIGHTS TSDR CALA2017040700907Battery · dischargedEMERGENCY EXIT DOOR LIGHT BATTERIES FAILED CAPACITANCE TEST AT FWD AND AFT POSITIONS REF JC JE18-2428-1-6192. CHANGE EMERGENCY EXIT DOOR LIGHT BATTERIES AT LOCATION FWD AND AFT REF AMM 33-51-38. TEST PASSED.SDR CALA2017030400521Unknown · odorBURNING PLASTIC ODOR DURING TAKE OFF, DISSIPATED BY 10000 FT. NO ABNORMAL ENGINE INDICATION, ODOR ONLY LASTED 5 MINUTES. INSPECTED BOTH ENGINES FOR PLASTIC, FOUND NONE. CREW STATED NO ODORS RETURNED. OK FOR SERVICE.SDR CALA2016081195635Module · no testLEFT AFT EMERGENCY LIGHT MODULE FAULT RESET THE MODULE, OPS CHECKED GOODSDR CALA2016033195243Fastener · looseFOUND LT MLG DOOR HINGE & ACT FITTING FASTENERS LOOSE. INTERIM REPAIRED MLG DOOR FITTING & KEEL BEAM SUPPORT STRUCTURE IAW ECRA 5330-05417.SDR CALA2015110394781Hinge Fitting · damagedDURING C2 CHECK, FOUND LT MLG DOOR HINGE & ACT FITTING FASTENERS LOOSE. INTERIM REPAIR TO MLG DOOR FITTING & KEEL BEAM SUPPORT STRUCTURE IAW ECRA 5330-05417 FOR 6 MONTHS PER RDAS 800 73792-003-2015 ISSUE A DATED 23 OCT 15. A NEW RDAS MUST BE RECEIVED PRIOR TSDR CALA2015022793180Warning System · false activationABORTED TAKEOFF DUE TO NUMEROUS FMGC RELATED FAULTS. REPORTED AROUND 100 KTS AT REJECT. PERFORMED AFS BITE, NO FAULTS DETECTED.SDR CALA2014033190729Deu · defectiveSTATIC IN CABIN SPEAKERS WITH CIDS CAUTION LIGHT ON. PERFORMED TROUBLESHOOTING 23-73-00-81 0-835A. FOUND BAD DEU A 200RH06. REPLACED & PERFORMED CIDS CHECK, ALL NORMAL.SDR CALA2013121293626Quick Disconnect · looseBRAKE 2 LEAK. INSPECTED NR 2 BRAKE & FOUND AFT QUICK DISCONNECT LOOSE, SECURED AFT QUICK DISCONNECT TO NR 2 BRAKE. CLEANED WET AREA & PRESSURIZED BRAKES WITH MULTIPLE ACTUATIONS & SET BRAKES, NO LEAKS N0TED.SDR CALA2013120693509Window · crackedROCK SHATTERED FLIGHT OFFICER`S SIDE WINDOW ON TAXI OUT.SDR CALA2013112293192Strap · missingNEED LIFE VEST REINSTALLED 31D, STRAP IS MISSING. MEL COMPLIED WITH SEAT IS UNUSABLE. INSTALLED NEW LIFE VEST WITH STRAP. SEALED LIFE VEST COMPARTMENT AT SEAT 31D.SDR CALA2013110592672Connector · damagedDURING STARTING OF ENG NR 2, UPPER ECAM DISPLAYS "ENG 2 EPR MODE FAULT" & "N 1 DEGRADED MODE". EEC CONNECTOR 4000KS-J2 DAMAGED, REPLACED CONNECTOR. SEE SEQ 3632010.SDR CALA2013102892403Life Vest · faultyFLIGHT ATTENDANT SAYS SHE NEEDS A SINGLE CHAMBER LIFE VEST DEMO. REPLACED LIFE VEST AS NEEDED.SDR CALA2013090591011Skin · gougedFS SKIN GOUGE AT FR21 BETWEEN STRINGER 41R & 42R. LIFE LIMITED REPAIR, IAW SRM 53-00-11. INSTALLED PERMANENT DOUBLER REPAIR IAW SRM 53-11-11 FIG 214 ON NR.SDR CALA2013081390395Life Vest · missingSEAT 27C MISSING LIFE VEST AND SEAL. NEW INTERIOR WITH NEW STYLE VESTS. SEAT 27C INOP DUE TO MISSING VEST AND SEAL. UNABLE TO DETERMINE CORRECT PCN FOR VEST. SEAL PCN IS (004-0051).SDR CALA2013081290336Skin · deformedRT AFT FUSELAGE PANEL HAS SOME DEFORMATION IN UPPER RT CORNER. REPAIRED AFT FUSE PANEL LOWER FWD CORNER. REPLACED 2 SHEARED RIVETS.SDR CALA2013080790228Switch · inoperativeNR 2 ENGINE IGNITERS WILL NOT SHUT-OFF. INSTALLED NEW TOGGLE SWITCH IAW WDM 76-12-01. ACCOMPLISHED ENGINE RUN IAW JRH. MASTER LEVER 2 SWITCH. OPS CHECKED NORMAL. NO FAULTS.SDR UALA2013070804736Switch · missingAFT CARGO DOOR CONTROL SWITCH LEVER MISSING. REPLACED AFT CARGO DOOR SWITCH ARM IAW AMM.SDR UALA2013070104558Processor · malfunctionedHAD A 3400 LB FUEL IMBALANCE WITH 7500 IN CENTER TANK. BALANCED AND WHEN CENTER TANK EMPTY HAD 800 IMBALANCE. FUEL IMBALANCE CONTINUED. LEFT HAD A HIGHER FUEL BURN AND ALL PUMPS SEEM OK. LEFT SIDE WAS HEAVY SIDE WHICH IS CONTRARY TO LEFT ENGINE BURN. ACCOSDR UALA2013062704482Window · delaminatedFIRST OFFICER`S SIDE WINDOW HAS DELAMINATION. FOUND DELAMINATION AT 3 INCHES IN AREA B. DELAMANATION AT 3 INCHES IN AREA B. FIRST OFFICER`S NR 3 WINDOW REPLACED.SDR UALA2013061304066Seal · missingLEFT SIDE L/E SLAT TO BODY FAIRING SEAL MISSING 6 INCHES. REPLACED SEAL ON LT LEADING EDGE SLAT TO BODY FAIRING.SDR CALA2013082990822Bottle · low pressureFOUND 1L DOOR ASSIST BOTTLE PRESSURE ZERO. REPLACED DOOR 1L ASSIST BOTTLE.SDR UALA2013052303596Microphone · intermittentCAPTAIN`S MICROPHONE CAUSING INTERMITTENT COMMUNICATION. REPLACED CAPTAIN`S MICROPHONE, OPS NORMALSDR UALA2013042502898Tail Cone · crackedNR 1 ENGINE EXHAUST TAILCONE CRACKED. TOTAL LENGTH OF CRACK EST 9 INCHES. REPLACED TAILCONE.SDR UALA2013032001712Window · damagedDELAMINATION BEGINNING ON FWD SIDE OF FIRST OFFICERS FIXED SIDE WINDOW. VISION NOT IMPAIRED. DELAMINATION IS APPROXIMATELY 4 AREAS OF 1 INCH LENGTHS RUNNING FORE TO AFT.SDR UALA2012122707425Computer · faultyACFT HAS CONSTANT PITCH *UP* WHILE HAND FLYING. CREW HAD TO APPLY CONSTANT FORWARD PRESSURE ON STICK TO KEEP FROM CLIMBING. ACFT FLIES OK IN WITH AUTOPILOT ENGAGED. PREV HISTORY SHOWS ELAC 2 COM OR WIRING ACCLRM4 12CE4. REF TSM 27-93-00-810-818A. CHECKED SDR UALA2012100305619Turbine Blades · crackedENGINE FAILED BORESCOPE INSPECTION DUE TO REPORTED 3EA T1 BLADES WITH RADIAL TIP CRACKS AND 1 EA T1 BLADE WITH AXIAL CRACK IN AREA "C" ON CONCAVE SIDE OF BLADES. REPLACED ENGINE.SDR UALA2012090605019Light · inoperativeON EMERGENCY LIGHTS TEST, RED EMERGENCY SEAT LIGHT AT 20C DID NOT ILLUMINATE. DEFERRED EMERGENCY SEAT PATH LIGHTING INOP AT 20C. MEL REF 3350C, DF700. REMOVED & REPLACED EMERGENCY PATH LIGHT ASSY AT SEAT 20C, OPS CHECK'S GOOD.SDR UALA2012090605018Light · brokenEMERGENCY ESCAPE PATH LIGHT BROKEN AT 23C. DEFERRED EMERGENCY SEAT LIGHTING AT 23C, REF MEL 3350C, DF 699. REMOVED & REPLACED EMERGENCY PATH LIGHT ASSY AT SEAT 23C, OPS CHECK'S GOOD.SDR UALA2012090605017Light · brokenEMERGENCY ESCAPE PATH LIGHT AT SEAT 1B BROKEN. DEFERRED EMERGENCY PATH SEAT LIGHTING AT 1B, MEL REF 3350C, DF698. REMOVED & REPALCED EMERGENCY PATH LIGHT ASSY SEAT 1B, OPS CHECK'S GOOD.SDR UALA2012061103192Actuator · failedREVERSER FAULT DISPLAYED ON UPPER ECAM SCREEN. NO PROBLEMS FOUND. REPLACED UPPER NO LOCKING ACTUATOR. REMOVED AND REPLACED AND RIG. REPLACED ACTUATOR.SDR UALA2012053103029Warning Message · false activationNR 2 ENGINE THRUST REVERSER FAULT DISPLAYED ON UPPER ECAM SCREEN. CHECKED ROOT FAULT PER AMM 70-00-00 P301 ON MCDU WITH FADEC SWITCH ON. ACCOMPLISHED TEST OF THE NR 2 ENGINE THRUST REVERSER SYSTEM THRU THE MCDU, FOR BOTH CHANNEL A AND B. TEST PASSED. FAULTSDR UALA2012052402907Computer · faultyFIRST OFFICERS AIRSPEED INOPERATIVE. ALL CHECKS GOOD FROM ADR2 TO 1510VT TO 1851VT NO DEFECTS FOUND. REPLACED ELAC 1 PER AMM, OPS CHECKED NORMAL.SDR UALA2012042302404Access Panel · damagedLEFT WING FUEL PANEL 540 HB AS FOUR MISDRILLED HOLES INTO BOTTOM WING SKIN. THREE HOLES OUT OF LIMIT, REAMED TO .362' AND COLD WORKED HOLES, REAMED TO .391'. INSTALLED BUSHINGS PER SRM 57-27-11. HFEC INSP PER NTM51-10-01, NO CRACKS NOTED. N-R'S V5283H, ANDSDR UALA2012042302424Hinge · crackedLT NR 4 ELEV HINGE ARM ON HORIZONTAL STAB IS CRACKED ON TOP ON INBD FLANGE. REMOVED DAMAGED HINGE AND INSTALLED NEW HINGE. MAJOR REPAIR.SDR UALA2012042002381Hinge · crackedLEFT NR 4 ELEVATOR HINGE ARM ON HORIZONTAL STAB IS CRACKED ON TOP ON INBD FLANGE. REMOVED DAMAGED HINGE & INSTALLED NEW HINGE. MAJOR REPAIR.SDR UALA2012030701494Nose Cowl · corrodedNR 2 ENGINE NOSE HAS CORROSION AT 6 O"CLOCK POSITION. REMOVED NR 2 ENGINE NOSE COWL PER MM. INSTALLED NEW NOSE COWL PER MM. ACCOMPLISHED OPS CHECK PER MM. NO FAULTS FOUND.SDR UALA2012010300047Battery · failedEMERGENCY LIGHT TEST FAILED EPSU 2L AFT. REPLACED 2L EMERGENCY BATTERY. ACCOMPLISHED EMERGENCY LIGHT TEST, TESTED GOOD.SDR UALA2011091204915Ram Air Turb · faultyTHIS ITEM FOR WORK PROGRESSION OF EG5720, RAM AIR TURBINE REPLACEMENT. REPLACED RAM AIR TURBINE. NEED TO DO FUNCTIONAL TEST AND PANEL INSTALLATION DUE TO RAT REPLACMENT REF EG5720. NUMBERS ARE ALREADY RECORDED IN EG 5720 MR29222-11 OFF MR29222-19 ON. REPLACSDR UALA2011081004205Skin · damagedGOUGE ABOUT 8" LONG ON LEFT SIDE OF VERTICAL STAB ABOUT 6' UP FROM FUSELAGE. DAMAGE IS EXPOSED COMPOSITE DUE TO PAINT SEPARATION ON VERTICAL STAB AT ZONE 323 STA 299 DAMAGE IS AN UNEVEN AREA EXTENDED OVER 10" LONG AND 4" WIDE. MADE TEMPORRAY REPAIR PER SRM. SDR UALA2011080504098Pressure Switch · faultyGREEN SYS PRESSURE LOSS, RTFL. GREEN SYSTEM ENG DRIVEN PUMP LOST PRESSURE. REPLACED NR 1 ENG DRIVEN PUMP AND FILTERS PER AMM. NO METAL FOUND IN FILTERS, RAN ENG FOUND PUMP OUTPUT GOOD BUT GREEN LINE FOR ENG PUMP ON ECAM HYD PAGE NOT INDICATING CORRECTLY. RSDR UALA2011072603826Socket · failedCREW STATED THE ODOR SMELLED LIKE A BURNING CIRCUIT BOARD. IT WAS VERY STRONG AROUND ROWS 24,25,26,27 AND RIGHT BEFORE FWD AFT LAV PAX IN THIS AREA ALL SMELLED THIS ODOR. ONE PAX WAS A THROUGH TRIP PAX AND SMELLED THIS ON LANDING WITH THIS SAME AIRCRAFT IN TSDR UALA2011010400044Skin · damagedLT OTBD FLAP, OTBD T/E TIP SHOWS EVIDENCE OF IMPACT DAMAGE AND IS DEFLECTED UP. T/E DEFLECTED UP .100 INCH, LENGTH OF DEFLECTION EXTENDS INWARD 3.5 INCHES FROM OTBD EDGE. REPLACED LT OTBD FLAP.SDR UALA2010072602673Sill · corrodedCORROSION ON CABIN DOOR SILL PLATE AT R2 DOOR AREA AFT END UPPER SURFACE. INSTALLED NEW DOOR SILL PLATE AT DOOR 2R. OK FOR SERVICE.SDR UALA2010061602126Adapter · failedRECEIVED SLIDE WITH PACKING ADAPTER STILL ATTACHED TO THE ASPIRATOR. VACUUM ADAPTER IS USED TO AID DURING PACKING OF THE SLIDE. IT IS TO BE REMOVED WHEN PACKING IS COMPLETED. REMOVED VACUUM ADAPTER FROM SLIDE. PROCEED TO O/H SLIDE.SDR UALA2010060301935Slide · low pressureDOOR 2, RT ESCAPE SLIDE LOW PRESSURE. BELOW GREEN BAND BY 50 LBS. TEMP STABLE AT 65 DEG F. REPLACED SLIDE ASSY.SDR UALA2009121503869Lens · misinstalledEVACUATION LIGHTS POINT UP INSTEAD OF DOWN. CONFERED WITH F/A, AFT OVERHEAD ENTRY DOORS LENSES INSTALLED WRONG, INSTALLED LENSES CORRECTLY, LIGHTS CHECK GOOD.SDR UALA2009112303638Battery Pack · dischargedEPSU BATTERY EMER L' MESSAGE DISPLAYED ON CIDS SCREEN WHEN PERFORMING CABIN EMERGENCY LIGHTING TEST PER NR 3 SERVICE. REPLACED BATTERY PACK & POWER SUPPLY.