N458UA
Service difficulty reports · 150
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N458UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N458UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013111893025Structure · scratchedR2 DOOR SCRATCHED AT BOTTOM EDGE 11 INCHES AFT OF FWD EDGE, 1 1/2 INCHES WIDE BY 1 INCH TALL SCRATCH GOES INTO THE METAL. INSPECTED AREA IAW SRM 52-10-00 PG 104. FOUND WITHIN LIMITS.SDR CALA2013111392886Fastener · missingFASTENER NEEDS TIGHTENING JUST FWD OF THE NR 2 PACK EXHAUST. REPLACED MISSING FASTENER.SDR CALA2013101091925Wire · damagedEMERGENCY LIGHT AT LT FWD WINDSCREEN IS INOPERATIVE. TERMINATED EXIT LIGHT WIRING.SDR CALA2013092591432Control Unit · failedON LANDING AIRCRAFT PULLED LT WITHOUT LT BRAKE PRESSURE. CONTINUED ALL THE WAY TO GATE. ACCOMPLISHED TROUBLESHOOTING IAW AMM. BSCU FAILED TEST. REPLACED BSCU IAW AMM. NWS LESS THAN 3 DEGREES OF RUDDER TRIM REQUIRED.SDR CALA2013092391346O-Ring · leakingLT ENG LEAKING FLUID. FOUND OIL SCAVENGE TUBE LEAKING ABOVE OIL DRAIN MAST LOWER MCD. REPLACED O-RING AS IAW IPC 79-22-41-80A ITEM 90. CREW RAN ENGINE, LEAK CHECKED GOOD.SDR CALA2013082990839Panel · dentedDENT FORWARD CARGO DOOR BY HANDLE. REMOVED LOWER PANEL 825AR FROM FORWARD CARGO DOOR. PANEL PLACED ON PAC ORDER NR N5708. CDL IAW 52UR PARTS: 110-0461 D5237173500000 PANEL.SDR UALA2013070204619Oil Cooler · leakingNR 1 ENGINE OIL COOLER LEAKING. PER MT 79-007, RAN NR 1 ENG AND FOUND THE LOWER AFT CORNER OF THE OIL COOLER TO BE LEAKING OIL AT 12-15 DROPS PER MINUTE. OIL COOLER REPLACED. LEAK CHECKED GOOD, NO MESSAGES.SDR UALA2013062504401Window · looseFIRST OFFICER`S WINDSHIELD HAS AIR LEAK/SLIPSTREAM NOISE. STARTS AT ABOUT 220KTS ALL ALTITUDES. FOUND WINDOW UPPER RETAINER BOLTS LOOSE, TORQUE CHECKED WINDOW FASTENERS AND RESEALED.SDR UALA2013060303839Line · leakingOIL DRIPPING FROM NR 1 ENGINE. FOUND SCAVENGE LINE LEAKING, ONE DROP IN FIVE MINUTES. BACKED FLANGE NUTS OFF TWO TURNS AND RETORQUED. PERFORMED LEAK CHECK, NO LEAKS NOTED.SDR UALA2013041602601Unknown · odorPACKS PRODUCE A STRONG ACIDIC SMELL IN THE DESCENT. OCCURS WHEN THRUST IS REDUCED. REPEAT ITEM PERFORMED HIGH POWER ENGINE RUN WITH BOTH ENGINES, PACKS ON, NO SMELL NOTED. OK TO CONTINUE.SDR UALA2013040902362O-Ring · damagedFOUND FUEL LEAKING AT LOW PRESSURE FUEL SWITCH ON APU. REPLACED O-RING SEALS AT APU LOW PRESSURE SWITCH. ACCOMPLISHED APU RUN, NO LEAKS NOTED.SDR UALA2013040802300Armrest · looseARMREST-CONSOLE LOOSE (ROCKS) AT 26D. ARMREST LOOSE. REPAIRED USING ECRA 2521-02520. NEEDS ARMREST, PCN 005-5512. REMOVED AND REPLACED ARMREST ON SEAT 26D. OPS CHECKS GOOD. OK TO CONTINUE.SDR UALA2013032701961Battery · failedACFT FAILS EMERGENCY LIGHT TEST PER 2SVC. FAILS FOR ESPU L. FOUND ESPU BATTERY LEFT FAILED. REPLACED BATTERY, OPS CHECKED OKAY.SDR UALA2012121907295Jack · dirtyON THE GROUND INTERPHONE HAS PROP LIKE SOUND AND HOT INTERPHONE PILOT-TO-PILOT DOES NOT TRANSMIT. MAINT TEXT: REMOVED AND REPLACED AMU, NO HELP. RE-INSTALLED ORIGINAL AMU CHECK CABIN INTERPHONE CHECKS OKAY. TRIED TO RESET WITH FLT INT C/B, NO HELP NEED MORSDR UALA2012120707088Windshield · delaminatedF/O FIXED SIDE WINDOW SHOWS DELAMINATION. DELAMINATION AT LOWER SIDE MEASURES 3.56" FROM EDGE. REPLACED F/O'S WINDSHIELD.SDR UALA2012111206469Power Supply · faultyLEFT AFT EMERGENCY POWER SUPPLY HAS A UNIT FAULT LIGHT ON WHEN TESTED. REPLACED POWER SUPPLY, TESTED OKAY.SDR UALA2012101605895Battery Pack · failedCABIN EMERGENCY LIGHT TEST FAILED. EPSU BATTERY EMERGENCY L OF FWD FLIGHT ATT PANEL. REPLACED BATTERY PACK.SDR UALA2012100505654Epsu · faultyFOUND UNIT FAULT ON FWD EMERGENCY POWER SUPPLY UNIT. REPLACED FWD EPSU AND EPSU BATTERY PER MM.SDR UALA2012100505653Power Supply · inoperativeCABIN EMERGENCY LIGHT TEST FAILED. SHOWS EPSU INT LOAD AFT LEFT AND EPSU EXT LOAD AFT LEFT. REPLACED AFT EPSU AND EPSU BATTERY, OP CHECK NORMAL.SDR UALA2012092905495Light · inoperativeCAPT DOME LIGHT INOP IN DIM POSITION. OK IN BRIGHT. REPLACED LAMPS. CHECKED NORMAL.SDR UALA2012092505436Shade · brokenF/O SUN SHADE BROKEN. REPLACED AND INSTALLED SUN SHADE.SDR UALA2012092105358Switch · defectiveF/O SEAT ELECTRICAL ADJUSTMENT, HORIZONTAL ADJUSTMENT INOP - INTERIOR. ELECTRICAL HORIZONTAL ADJUSTMENT SWITCH INTERMITTENT. REPLACE HORIZONTAL ELECTRIC SWITCH. OPS CHECKS OKAY.SDR UALA2012091305167Shoulder Belt · frayedFLIGHT ATTENDANT JS 252 SHOULDER STRAP FRAYED-UNSERVICEABLE. REPLACED FLIGHT ATTENDANT HARNESS, OPS OKAY.SDR UALA2012073004105Battery Pack · no testEMERGENCY LIGHT TEST FAILED PER NR 3 SERVICE EPSU FWD L. REPLACED BATTERY.SDR UALA2012062903464Doubler · corrodedCORROSION ON SKIN DOUBLER AT FR65-66 STR 40R-41R. INTERNAL DOUBLER AT THE LAV SERVICE PANEL. REPLACED INTERNAL DOUBLER AT LAV SERVICE PANEL REF SRM. MAJOR REPAIRSDR UALA2012062903463Failsafe · corrodedSTRINGER CLIP AT FR 66 BETWEEN STR 40R AND 41R IS CORRODED. REPLACED STR CLIP IAW SRM.SDR UALA2012062903443Stringer · corrodedSTRINGER 41R AT FR 61-62 HAS CORROSION. REPLACED STRINGER SECTION 41R FR 58-64 PER SRM. MAJOR REPAIR.SDR UALA2012062903442Stringer · corrodedSTRINGER 40R AT FR 65-66 HAS CORROSION. REPLACED STRINGER PER SRM. MAJOR REPAIRSDR UALA2012062903401Stringer · corrodedSTRINGER 41R AT FR 61-62 HAS CORROSION. REPLACED STR SECTION 41R FR 58-64. MAJOR REPAIR.SDR UALA2012062903400Stringer · corrodedSTRINGER 40R AT FR 65-66 HAS CORROSION. REPLACED STRINGER PER SRM, MAJOR REPAIRSDR UALA2012062903417Feeder Cable · damagedNR 1 ENGINE POWER FEED CABLE PUNCTURED AND SIGNS OF ARCING LOCATED JUST FWD OF THE INBD THRUST REVERSER ACTUATOR. REPLACED IDG HARNESS PER MM .SDR UALA2012040602133Cover · delaminatedRIGHT OFF WING SLIDE COVER DELAMINATED AFT EDGE ABOVE SLIDE OPENING. REPLACED OF WING SLIDE. SLIDE ASSY IS SECURE ON ACFT, LINE IS SECURE, INFLATION CYL SAFETY PIN IS REMOVED AND STOWED, EMERGENCY LIGHTS TEST OK. ACFT RETURNED TO NORMAL OPS.SDR UALA2011072503793Structure · damagedLT OUTBD FLAP HAS DAMAGE. DATE LEFT FLAP LE INSTALLED. INSTALLED BULL-NOSE AND SEALS.SDR UALA2011041101724Smoke Detector · faultyCREW REPORTED LAV SMOKE DET ECAM. NO TIME TO WORK. REPLACED FWD LAV SMOKE DETECTOR AND RESET CIDS AND CIDS OK.SDR UALA2011032501448Tip Cap · damagedLIGHTNING STRIKE DAMAGE AT AFT OUTBOARD CORNER. REPLACED RT ELEVATOR TIP PER AMM AND REMOVED AND RE-INSTALLED RT HORIZ STAB TIP FOR ACCESS.SDR UALA2011022500941Slide · out of toleranceBOTH LT AND RT OFF WING SLIDE DOOR PINS PAINTED OVER. VEDOR REMOVED PAINT BUT SLIDES NEED REPLACEMENT. BOTH LT & RT DEFECTIVE OVERWING SLIDES REMOVED. COMPLETED INSTALLATION OF LT AND RT OVERWING SLIDES.SDR UALA2011013100503Wire · shortedAPU AUTO SHUTDOWN AT GATE WITH LOW FUEL PRESSURE WARNING ON ECAM. SHORTED WIRE NEAR APU CIRCUIT BREAKER. DURING REPLACEMENT OF CB AA8, POWER WAS APPLIED TO ACFT & ARCING OCCURRED. WIRE HAS INSULATION DAMAGE TO SEVERAL AREAS. DURING WIRE INSPECTION FOUND WISDR UALA2010102503943Bolt · shearedCABIN FLOOR EXPANSION JOINT C-46, RT BOLT IS SHEARED. ALL 6 BOLTS REPLACED AND AREA INSPECTED IAW MM.SDR UALA2010072302635Light · inoperativeCHECK OF CABIN EMERGENCY LIGHT (3 SVC) TEST FAILED. MSG EPSU INT LOAD EMER L, TEST AT OVERWING EMER LIGHT POWER SUPPLY INDICATES THE SAME. REPLACED EMER LIGHTS AT PAX SEAT 16 AND 25, OPS CHECKED GOOD. EMER TEST GOOD.SDR UALA2010061502107Valve · failedSKIN VALVE FAULT, RTFL R & R SKIN AIR VALVE IAW AMM. PERFORMED OPS CHECK, OPS CHECKS OK. PERFORMED OPERATIONAL CHECK, OPS CHECKS OKAY. CFDS BITE CHECK OK.SDR UALA200908170250ALens · missingRAMP REPORT: BAG LOADER RECEIVED ELECTRICAL SHOCK OPERATING FORE AFT SWITCH-AFT PIT. FOUND AND CONFIRMED BY RAMP LOADER WHO WAS SHOCKED, LENS CAP MISSING AT TBS STA IN AFT PIT. TOUCHED EMPTY SOCKET WHILE OPERATING SYS. REPLACED LENS CAP-SYS OPERATES NORMAL.SDR UALA2009041301054Valve · malfunctionedWATER PRESSURE ISSUE. RTFL. FOUND WATER TANK FULL AND FILL VALVE CLOSED. CREW REPORT, THERE WAS WATER PRESS ON GROUND, BUT NONE AFTER DEPARTURE. TANK DRAINED. LAV AND GALLEY DRAINS NOT AFFECTED. TRIED TO PRESSURIZE WITH ENGINES AND APU AIR, NO JOY. WATESDR UALA2009031600787Power Supply · faultyEMERGENCY LIGHTING EPSU 12WL SHOWS A 'UNIT FAULT' DURING SELF-TEST. REPLACED EPSU 12WL. OP CHECK GOOD.SDR 2008UALA01043Battery · dischargedDOOR 1L FLIGHT ATTENDANT EMERGENCY FLASHLIGHT BATTERY DEAD. BATTERY FAILURE. REPLACED BATTERY.SDR 2007UALA00960Battery · faultyFWD EPSU BATTERY FAULT & EPSU BATTERY L DISPLAYED ON PTP. REPLACED BATTERY.SDR 2007UALA00877Light · faultyFWD EMERGENCY EXIT LIGHTS ARE ON WITH SEAT BELT SWITCH ON. SUP.4-17-07. RESET CIDS SYS. AND LIGHTS CKD NORMAL.SDR 2006UALA01491Battery · failedEMERGENCY LIGHTS FAIL TEST EPSU FWD L. SUPPLEMENTAL DATA UPDATE REPLACED EPSU BATTERY.SDR 2002UALA00565Filter · cloggedABORTED TAKEOFF AT 73 KNOTS DUE TO AN AVIONICS COOLING FAN MESSAGE. FOUND AVIONICS COOLING SYSTEM FILTER CLOGGED. REPLACED SAME.SDR 2000UALA00368Warning System · activatedABORTED TAKEOFF AT 100 KNOTS DUE TO FLIGHT MANAGEMENT SYSTEM AND POSITION DISAGREEMENT MESSAGE ON ELECTRONIC CENTRALIZED AIRCRAFT MONITORING SYSTEM. *S/D* NO ACTION TAKEN BY MAINTENANCE. THIS IS A KNOWN ANOMALY AND CREW INSTRUCTIONS FOR HANDLING THIS POSITISDR 2000UALA00133Computer · malfunctionedCOULD NOT PRESSURIZE CABIN AFTER TAKEOFF. SHORTLY AFTER DEPARTURE, VENT AVIONICS SYSTEM FAULT ECAM MESSAGE APPEARED WITH A RUMBLING, EVIDENT ON THE RIGHT SIDE OF THE ACFT. SYSTEM DID NOT CORRECT ITSELF AFTER FOLLOWING ECAM PROCEDURE, STOPPED CLIMB AT 10,000