N458UP
Service difficulty reports · 215
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N458UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N458UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2018032627831Floor Panel · damagedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 241XMF HAS BROKEN INSERT HOLES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527809Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XGF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527808Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527807Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XHF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527806Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 232XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527804Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 232XDF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527803Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XDF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527802Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 252XRF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527796Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 232XGF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527795Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 252XQF HAS WORN INSERT HOLES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527793Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 232XHF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032727898Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PANEL 231XCF WAS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K, AND SREO B757-5320-9692-K.SDR IPXA2018032727897Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PANEL 232XCF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527816Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PANEL 222XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527815Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 222XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527814Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PANEL 221XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527813Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PANEL 221XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527812Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PANEL 222XCF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527811Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PANEL 221XCF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527800Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK FLOOR PANEL 231XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527799Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PANEL 232XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527798Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PANEL 231XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018032527797Floor Panel · delaminatedINSPECTION TYPE: SEG3, MAIN DECK WET AREA FLOOR PNL 232XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017120524222Lens · damagedINSPECTION TYPE:NAFOUND EMER LIGHT IND LIGHT LENS BROKENRECAPPED CAP ASSY PER SOPM 20-11-05 OPS CKS OKSDR IPXA2016040801828Attach Bracket · crackedINSPECTION TYPE:C10, 313AL LT LATCH PAD BRACKET LOWER ATTACH FLANGES CRACKED INSTALLED REPAIR ANGLES ON LATCH PAD BRACKETS IAW SRM 51-70-11-0G.SDR IPXA2016040501723Transition Panel · corrodedINSPECTION TYPE:C10, AFT PIT RT TRANSITION PANEL HAS CORROSION NEAR TIE DOWN FITTING AT BS 1280 INSTALLED REPAIR FILLER AND DOUBLER IAW SRM 51-70-13.SDR IPXA2016033101414Transition Panel · corrodedINSPECTION TYPE:C10, AFT PIT RT TRANSITION PANEL HAS CORROSION NEAR TIE DOWN FITTING AT BS 1280 INSTALLED REPAIR FILLER AND DOUBLER IAW SRM 51-70-13.SDR IPXA2016040601753Skin · damagedINSPECTION TYPE:C10, LOWER AFT CARGO DOOR SKIN LWR FWD CORNER HAS 1 EA CREASE. REPAIRED IAW EO NR: 5230-60367-A.SDR IPXA2015031486987Mount · looseF/O EVAS LOOSE, MOUNT NEEDS SECURED. RESECURED F/O EVAS MOUNT IAW
EO B757-2560-45125-G.SDR IPXA2014041482628Panel · delaminatedINSPECTION: C9, RT LOWER VERTICAL STAB TORQUE BOX PANEL IS DELAMINATED SEVERAL AREAS. REPAIRED IAW REO-G17337, REV B & EO B757-5530-54064-A.SDR IPXA3578299Skin · puncturedNR 8 SLAT HAS 1 INCH HOLE UPPER SKIN 2.75 INCHES FROM FWD EDGE AND 37.5 INCHES FROM INBD E. REPAIRED IAW EO B757-5750-50728-A, COMPOSITE REPAIR.SDR IPXA13576679Skin · dentedLEFT WING INBD MAIN FLAP T/E SKIN DENTED. REPAIRED IAW EO B757-5750-49091-B.SDR 2013FA0000005Skin · damagedFUSELAGE SKIN DAMAGED, BS 243.SDR IPXA12574781Bulb · inoperativeLOWER EGRESS EMERGENCY LIGHT INOPERATIVE. R & R BULB IAW MM 33-51-06-962-001-003. OPS NORMAL.SDR IPXA2574212Skin · debondedNR 5 SLAT HAS A 1.75 DIA DENT THAT IS DISBONDED 20" OTBD FROM INBD EDGE AND 2" FWD OF AFT EDGE. REMOVED DAMAGE. REPAIRED IAW B757-5750-47495 ON NRC 511176.SDR IPXA2574211Skin · damagedNR 5 SLAT T/E WEDGE HAS DENTED 39" INBD FROM OTBD EDGE. REMOVED DAMAGE AND REPAIRED IAW EO B757-5750-47495.SDR IPXA2574205Skin · dentedRT WING T/E INBD MAIN FLAP DENTED. REMOVED DAMAGE AND REPAIRED IAW EO B757-5750-46970 ON NRC 511174.SDR IPXA2573156Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XCF IS MISDRILLED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2573138Floor Panel · mismanufacturedINSPECTION TYPE:C CK, MAIN CARGO COMPARTMENT FLOOR PANEL 232XXF WAS FABRICATED WRONG. FABRICATED NEW FLOOR PANEL IAW EO.B757-5320-9692-H.SDR IPXA2573141Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 221XCF HAS PUNCTURE AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2573140Floor Panel · puncturedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 222XAF PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2573157Floor Panel · puncturedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 221XAF HAS PUNCTURE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2573137Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 231XSF HAS PUNCTURE AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2573158Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XFF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572986Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 231XFF IS DELAMINATED ALONG EDGES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2573159Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 231XMF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12573004Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 231XKF IS DELAMINATED AT FWD AND AFT CORNERS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12573003Floor Panel · missingINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 231XPF HAS INSERTS MISSING. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12573001Floor Panel · corrodedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 242XGF INSERTS CORRODED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12572998Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 252XTF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.
Back to N458UP