N463UA
Service difficulty reports · 117
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N463UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N463UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013040902365Oxygen Mask · failedCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). SWAPPED CAPTS OXYGEN MASK SERIAL 94410 WITH SEC OBS SEC OBS MASK SER 71814 NOW IN CAPT POS PER TASK 35-12-41 PAGE BLOCK 0401. OPS CHECK TASK 23-51-00-710-004 -A AND TASK 35-12-41-710-001-A. OPS CHECK SDR UALA2013020700726Battery · no testEMERGENCY LIGHT CHECK FAILED ON 2 2SVC. REPLACED AFT EPSU BATTERY, TEST PASSED. OPS CHECKED GOOD.SDR UALA2013020500703Battery · dischargedCABIN EMERGENCY LIGHT CHECK FAILED ON 2 2SVC. REPLACED AFT EPSU BATTERY PER MM,TEST PASSED OPS CHECKS GOOD.SDR UALA2013012800502Button · inoperativeCAPTAIN'S O2 MASK PRESS TO TEST NOT WORKING. REPLACED CAPTAIN`S 02 BOX.SDR UALA2012121407249Light · inoperativeFOUND ON NR 2 SERVICE LAV SMOKE CHECK, CALL LIGHT FOR LAV F DOES NOT ILLUMINATE (591RH6) ASM23-73-18. ALSO CIDS CLASS 3 FAULTS "PAX CALL LAMP LAV F" FAULTED. SWAPPED LAMPS WITH KNOWN GOOD LAMPS, NO HELP. FOUND WIRES BEHIND LIGHT ASSY NOT CONNECTED. SECUREDSDR UALA2012120707097Fastener · missingFASTENER MISSING LEFT SIDE FUSELAGE NEAR TRAILING EDGE OF INBOARD FLAP. SAMC TEXT: PANEL 197BB. REPLACED FASTENER LEFT SIDE FUSELAGE AT BLUE HYD SERVICE PANEL.SDR UALA2012110706408Computer · faultySLAT SYS 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. - F -CTL. REPLACED SFCC1 AND OP CHECK SATISFACTORY.SDR UALA2012110506338Regulator Valve · faultyAFT CARGO MIX VALVE STAYS FULL COLD EVEN WITH TEMP CONTROL KNOB ROTATED TO FULL HOT. DEFFERED AFT CARGO HEAT HOT AIR PRESS REG VALVE. COMPLETED REQUIREMENTS OF MEL ITEM 2143B. REMOVED AND REPLACED AFT CARGO HEAT PRESS REG VALVE REF AMM 21-43-52, OPS CHECKS SDR UALA2012103106289Blowout Panel · unsecureNR 1 OUTBOARD PYLON BLOW OUT PANEL 471BL FOUND OPEN AT ARRIVAL. INSPECTED DUCTS AND LEAK CHECKED OK.SDR UALA2012102906170Skin · dentedEXT FUSELAGE DENTED BETWEEN FR 23 AND 24 AND BETWEEN STR 42R AND 43R. FOUND OUT OF LIMITS. INSTALLED EXT DOUBLER PER SRM 53-11-11 FIG 104.SDR UALA2012102906169Skin · dentedEXT FUSELAGE DENTED BETWEEN FR 21 AND 22 AND BETWEEN STR 22L AND 23L. MAJOR REPAIR ACCOMPLISHED: FOUND OUT OF LIMITS. INSTALLED EXT DOUBLER PER SRM.SDR UALA2012102906168Threshold · corrodedCORROSION AT L2 DOOR THRESHOLD AT AFT INBOARD CORNER. MAJOR REPAIR ACCOMPLISHED: INSTALLED REPAIR PER SRM 53-41-14 FIG 201 ON NR 25483.SDR UALA2012102506118Attach Fitting · corrodedLEFT WING SIDESTAY UPPER CARDAN ATTACH FITTING OUTBOARD LUG BORE HAS PITTING CORROSION. BUSHING REMOVED, BORE CLEANED AND BUSHING REPLACED PER SRM.SDR UALA2012102506119Attach Fitting · corrodedRIGHT WING SIDESTAY UPPER CARDAN ATTACH FITTING OUTBOARD LUG BORE HAS PITTING CORROSION. BUSHING REMOVED, BORE CLEANED, AND BUSHING REPLACED PER SRM.SDR UALA2012081304400Transmitter · failedLT ENG OIL PRESSURE READS ALMOST FULL SCALE 298PSI ON TAKEOFF, NOTICED MOMENTARY FLUCTUATION. REMOVED AND REPLACED OIL PRESSURE TRANSMITER, PER MM 79-33-15-000-010-A 13,79-33-15-400-0 10-A 13.SDR UALA2012053103030Control Unit · malfunctionedL1 DOOR SLIDE SHOWS ARMED WITH DOOR OPEN, ECAM SLIDE MESSAGE ON, WITH DOOR OPEN AND IN DISARMED. REPLACED SDAC-1 PER TSM 52-11-00-810 -804. AND AMM 31-55-34-000-001 MESSAGE CLEARED. OPS CHECKED GOODSDR UALA2012052903016Sdac · malfunctionedDOOR 1L SLIDE SHOWS ARMED WITH DOOR OPEN. ECAM SLIDE MSG ON WITH DO OR OPEN AND IN DISARMED. REPLACED PROX SWITCH 4WN1 AND RELAY EO245-28AO, NO HELP. REPLACED 1WN1 SLIDE ARMED INDICATOR LIGHT. NO HELP. REPLACED SDAC-1 PER TSM, MESSAGE CLEARED. OPS CHECKSSDR UALA2012043002539Oxygen Bottle · failedOXYGEN BOTTLE MISSING, USED AT AFT CABIN, FWD CABIN FLIGHT ATTENDANT REPORTED THAT THE OXYGEN BOTTLE WAS FULL BUT FAILED TO PROVIDE OXYGEN TO PASSENGER. REPLACED OXYGEN BOTTLE AT AFT CABIN.SDR UALA2012040202049Window · damaged1ST OFFICER'S SLIDING WINDOW'S VISIBILITY IS IMPAIRED. CLEANED WINDOW FOR BETTER FLIGHT VISIBILITY, WINDOW WITHIN LIMITS. BUBBLES DO NOT IMPAIR FLIGHT VISIBILITY.SDR UALA2012030701484Valve · leakingNR 2 ENG FIRE LOOP A TB 450VT2 NEED OP CHECK AFTER SUPPORT BRACKT INSTALLATION. REPLACED BRACKET AND BURNDY BLOCK. NR 2 ENG STILL HAS "A" LOOP FAULT AFTER ENG START. FIRE LOOP A FAULT DISPLAYED ON UPPER ECAM SCREEN. REPLACED FIRE LOOP, OPS CHECKS GOOD. MSDR UALA2012030501342Fire Loop · defectiveINTERMITTANT DISPLAY OF ECAM ENG 2 FIRE LOOP 'A' FAULT. REPLACED FIRE LOOP 4001WD2. REF AMM 26-12-17. OPS CHECKS GOOD REF. 26-12-00-710-00 1." REOPENED ON 03MAR12 FOR: MESSAGE RETURNED REPLACED LOOPS 4000WD1 & 3WD2, CHK'D OK ON ENG RUN.SDR UALA2012030501329Fire Warning · false activationFIRE LOOP 'A' FAULT DISPLAYED ON UPPER ECAM SCREEN. -ENG 2. SAMC TEXT: CREW COMPLIED WITH MEL, APPLIED DF STICKER: DEFERRED PER SAMC NO HARD FAULT. REPLACED FIRE LOOP 4001WD2 REF, AMM 26-12-17 OPS CHECKS GOOD. REF AMM26-12-00-710-001", REOPENED ON 03MAR12 FSDR UALA2012030501328Fire Loop · defectiveINTERMITTANT DISPLAY OF ECAM ENG2 FIRE LOOP 'A' FAULT. MEASURED RESISTANCE AT FDC 2 BTWN PIN J AND K, OHMS READ 1510, IS WITHIN LIMIT NEED MORE T-S TIME. NO HARD FAULT. VISUAL INSPECTION OF FIRE LOOPS CHECKS GOOD. REPLACED FIRE LOOP 4001WD2. OPS CHECKS GSDR UALA2012022001030Computer · faultedAVIONICS VENT FAULT, FLIGHT DIVERTED. REPLACED AVIONICS EQUIPMENT VENTILATION COMPUTER AND TESTED SEVERAL TIMES WITH NORMAL INDICATION.SDR UALA2011102805830Transducer · failedELAC FAULT. REPLACED CAPT'S ROLL SIDE STICK TRANSDUCER 4CE1 REF AMM AND COMPLETED REJECTION FOLLOW-UP #RFU224068.SDR UALA2011102505771Fitting · failedDURING REMOVAL OF AFT LAV MODULE, FOUND OVERHEAD TURNBUCKLE BRACKET SHEARED OFF. REPLACED OVERHEAD FITTING FOR AFT FWD LAV HOLD ROD.SDR UALA2011102105687Floorbeam · corrodedFLOORBEAM CORRODED.SDR UALA2011101705600Battery Pack · inoperativeCABIN EMERGENCY LIGHTS FAILED TEST. SHOWS EPSU BATTERY FWD LT. REPLACED EPSU 10WL BATTERY PACK, OPS NORMAL.SDR UALA2011101405573Computer · malfunctionedCYCLIC VERTICAL BUMPING-PITCHING FELT AT CRUISE. FLIGHT CONTROL SD SHOWED LT & RT AILERONS MOVING UP & DOWN IN UNISON WITH BUMPING. CONSULTED FMC ELAC 1-2 FAULT, IRREGULAR. TURNED OFF ELAC 1, AILERON MOVEMENT STOPPED. NO FURTHER OCCURRENCE OF BUMPING-PITCHSDR UALA2011080804118Smoke Detector · faultyAVIONICS SMOKE MSG APPEARED ON LANDING, PER CREW. REPLACED AVIONICS SMOKE DETECTOR 1WA PER MM. OPS NORMAL, MSG GONE.SDR UALA2011072803892Controller · inoperativeFIRST OFFICER`S WINDSHIELD HEAT IS INOPERATIVE. REPLACED WHC NR 2 PER AMM. PERFORMED BITE TEST. CHECKED GOOD.SDR UALA2011070803404Seat · excess playF/O SEAT HAS EXCESSIVE PLAY IN PEDESTAL. REPLACED F/O'S SEAT ASSY, OP'S CHECK GOOD.SDR UALA2011030901151Window · failedOUTER PANE SHATTERED ON 2L SLIDING WINDOW. REMOVED 2L SLIDING WINDOW PER MM. INSTALLED NEW PANEL IN WINDOW FRAME. COMPLETED WINDOW INSTALLATION IAW MM.SDR UALA2010092803578Door · unsecureLAVATORY WASTE DOOR BENT OR WON'T OPEN-CLOSE FWD CAB LT LAV. FORWARD LAV DOOR WHICH HOLDS THE FIRE EXTINGUISHER FELL OFF. DOOR FALLS OFF BECAUSE THE HOLDER AT THE BOTTOM IS DAMAGED AND DOOR WILL NOT STAY IN PLACE SECURELY. NO TIME ORD. SECURED WITH SAFETY WIRESDR UALA2010072302642Apu · malfunctionedPACK AIR HAS STRONG SMELL. PACK AIR HAS STRONG SMELL REPEAT ITEM. THE OZONE FILTER IS MOST LIKELY BAD. NONE IN STOCK ORD. REPLACED APU AND RAN PACKS TO BURN OUT SMELL.SDR UALA2010050701552Selector Valve · faultedLOST NOSE WHEEL STEERING ON LANDING. RED ECAM MESSAGE WITH AUDIBLE DINGS FOR L/G GEAR NOT DOWN LOCKED, WENT AWAY AFTER 10 SEC THEN GOT \NOSE WHEEL STEERING FAULT. NEITHER TILLER HAD INPUT. STEERING DISCONNECT WAS NO HELP. REPLACED 19GA IAW MM. REPLACED SSDR UALA2010042001317Valve · faultyLGCIU FAULT. ON APPCH L/G DID NOT EXTEND ON FIRST ATTEMPT. HAS HISTORY. ACFT IS UP ON JACKS T-S'ING. NEED TO REPLACE PRIORITY VALVE. PRIORITY VALVE REPLACED. ACCOMPLISHED SUCCESSFUL LEAK CHECK. CYCLED GEAR SEVERAL TIMES, OPS OK. NO MESSAGES. ALSO CK'D FREE FASDR UALA2010040501114Unknown · odorFA'S HAD A BURNING ODOR IN AFT GALLEY AREA. NOW AFT GALLEY CHILLER MALFUNCTION LIGHT IS ON. CHECKED COFFEEMAKERS, COFFEE WARMERS, FLORESCENT LIGHTS (BALLASTS) OPERATING OK. NO ODOR DETECTED. DEACTIVATED CHILLER C31 (FWD CHILLER FOR AFT GALLEY COMPLEX). RAN CHISDR UALA2010022500696Shaft · contaminatedSTRONG ODOR IN COCKPIT, RTFL. REMOVED NR 2 ENG INLET CONE AND FAIRING. FOUND OIL IN THE EXTENSION SHAFT. REPLACED BLIND CAP AND SEAL. NEED TO ACP PACK BURN OUT AND REPLACEMENT OF RECIRC FILTER. ACCMP'D PACK BURNOUT. RAN ENGINES AT CLIMB POWER FOR ABOUT 15 MISDR UALA2010012500292Fan · faultySTRONG ELECTRIC BURNING ODOR DETECTED. REPLACED AVIONICS VENT EXT FAN 18HQ SYS. CFDS TEST CHECKED GOOD.SDR UALA2010011500176Cover · dislodgedEMERGENCY LIGHT SWITCH COVER FELL OFF. SECURED SWITCH COVER.SDR UALA2009113003689Elbow · leakingGREEN SYSTEM HYD LOSS. REPLACED RIGHT MLG DOOR HYD SWIVEL ELBOW FITTINGS ON DOOR ACTUATOR. REPLACED NR 1 ENG DRIVEN PUMP, REPLACED HP FILTER, REPLACED CASE DRAIN FILTER AND GREEN SYS MAIN FILTER. LEAK AND OPS CKS OKAY.SDR UALA2009101603248Power Supply · dischargedEMERGENCY LIGHT TEST FAILED FAULTING EPSU BATTERY EMERGENCY RIGHT AND LEFT SIDE. REPLACED RT BATTERY, OPS CHECKS NORMAL REPLACED LT POWER SUPPLY, OPS CHECKS NORMAL.SDR 2008UALA02731Lens · missingEMERGENCY AISLE LIGHT AT SEAT 18C IS MISSING LENS. REPLACED SEAT LIGHT. OP CHECKS OKAY.SDR 2008UALA02732Power Supply · failedEPSU INT LOAD EMER R MESSAGE AT CIDS DURING OPERATIONAL TEST OF EMERGENCY CABIN LIGHTS AND SIGN CK. FOUND EPSU FAILED. REPLACED RT O/W EPSU, CHECKS GOOD.SDR 2008UALA01659Lamp · inoperativeROW 21 EEL LIGHT INOP. SUPPLEMENTAL DATA UPDATE CAUSE, LAMP INOP. RELAMPED ASSY. OPS CHECKED NORMALLY.SDR 2008UALA00867Control Panel · faultyAPU FIRE BOTTLE DISCHARGE LIGHT IS ILLUMINATED BLOW OUT DISK IS INTACT LOW PRESSURE. FOUND APU FIRE TEST SWITCH INTERMITTENT STUCK, CAUSED APU BOTTLE DISCHARGE LIGHT PROBLEM. REPLACED ENG, APU FIRE PANEL (1WD) THEN OP-TEST NO FAULT.SDR 2008UALA00556Filler · leakingAIRCRAFT O2 LOW. SUPPLEMENTAL DATA UPDATE CAUSE: LEAKING FILL PORT ON CREW O2 SERVICING PANEL. REPLACED FILL PORT AND SERVICED CREW O2 TO FULL, NO LEAKS NOTED.SDR 2007UALA05203Oxygen System · faultyOXYGEN HIGH PRESSURE INDICATION AMBER ON DOOR-OXY SYSTEM ECAM. SERVICED CREW O2 SYSTEM, NO REPEATS.SDR 2007UALA05174Drain · defectiveFLIGHT DIVERTED DUE TO LOUD SQUEAL IN COCKPIT. PRESSURIZED A/C TO 5.7 PSI NO LEAKS, NO SQUEAL DUPLICATED. REPLACED THE FWD LOWER DRAIN. NO REPEATS SINCE ORIGINAL WRITE UP.