N469UA
Service difficulty reports · 70
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N469UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N469UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025081107583Indicator · faultedSTDBY ATTITUDE INDICATOR HAS FAILED REPLACED STANDBY ATTITUDE INDICATOR, OPS CHECK GOOD MM 34-22-24.APARTS USED: 31-4170-9-0001,QTY :1 ROTABLE PARTS CHG:TT # 1449521 SN OFF 2440 PN OFF 31-4170-9-0001 INDICATOR, STAN OFF 31-4170-9-0001 2440 ON 31-4170-9-0001 SDR CALA2025012402023Girt Bar · lack of lubeDOOR 2L SLIDE ARM LEVER DIFFICULT TO ARM. SHOWED ARMED ON THE GROUND B4 T/O. RED CAB PRS LIGHT LUBED LOWER GIRT BAR FLOOR LATCHES AND LOWER GIRT BAR BALL ENDS. DOOR ARM/DISARM OPS CHECK GOOD AT 18 FT LBS. REF: AMM TASK 12-22-52-640-014-A AND AMM TASK 52-10-SDR CALA2025010601784Light · missingLEFT LANDING LIGHT MISSING ON ARRIVAL. REF LOG# 3413284 SEE LOG #3413284 FOR CORRECTIVE ACTION. LT LDG LIGHT MISSING WIRES EXPOSED, REPLACED LH LANDING LIGHT HOUSING REF AMM 33-42-11-400-003-A. OPS CHECK GOOD AT THIS TIME.SDR CALA2024031100688Reservoir · overservicedCREW REPORTS YELLOW RESERVOIR OVERHEAT IN FLIGHT. YELLOW RESERVOIR APPEARS OVER SERVICED. ITEM LOCKED TO CONFIRM FIX. SERVICED AND COMPLIED WITH TSM REF TSM 29-13-00-810-802-A. - TOMC KROWN PERFORM INITIAL EVALUATION HYD OVERHEAT MSG. FOUND YELLOW SYSTEM WAY OSDR CALA2023092502869Frame · crackedLH FR35 STG 30 AT FASTENER HOLE #14. CRACK INDICATION NOTED AT 3 O''CLOCK AND 9 O''CLOCK ON FWD SURFACE OF THE FRAME LAYER. PERMANENT SOLUTION WITH INSPECTION REQUIREMENTS. ACCOMPLISH A 5331-03052 ON OR BEFORE 20-MAR-2024. SOLUTION WITH INSPECTION REQUIREMENTSSDR CALA2023050301348Seal · missingPDA 3 #1 ENGINE INBOARD TR FLEX SEAL SEGMENT DEPARTED AIRCRAFT. REPLACED DAMAGED PANEL.SDR CALA2022052501351Seal · departedPDA 1 P/N D5461038200100 PEELED BACK AND BROKE OFF DEPARTING A/C APPROXIMATELY 15" X 4" THIN METAL PART. REMOVED REMAING PIECE OF SEAL AND REPLACED WITH NEW SEAL.SDR CALA2022052501337Seal · damagedLEFT NUMBER 1 ENGINE COWL SEAL BROKE OFFBY HINGE ACCESS PANEL REPLACED FWD INBD PYLON SEAL. P/N D5461038200000. NO.1 ENG.AMM 54-57-22-400-003-ASDR CALA2022032300769None · missingPDA 3 NLG ELECTRIC BOX LEVER MISSING BOTH SPRING CLIPS...SEE PHOTO PHOTO ADDED PARTS ADDED PER IPC 32-51-12-01E INSTALLED BOTH SPRING CLIPS ...REF IPC 32-51-12-01E..SDR CALA2020051700969Fuel Cap · missingPDA 2 WING FUEL CAP FOUND MISSING ON ARRIVAL.SDR CALA2020010600018Control Cable · damaged(AAR N/R 9031569) (SUPPORT TASK) FOUND BROKEN STRANDS ON L/H MLG FREE FALL CABLE BETWEEN FR42 AND FR46. REMOVED & REPLACED L/H MLG FREE FALL CABLE BETWEEN FR42 & FR46 P ER AMM A320 32-33-16-000-002-A STEPS 3.E.(2) & 4.C.(9) & AMM 32- 33-16-400-002-A. PERFORMEDSDR CALA2019120902168Connector · brokenAAR NR 9031839 (SUPPORT TASK) L-81 NO DOT CONNECTOR 201WL-A HAS BROKEN STRAIN RELIEF ON BACKSHELL REMOVED AND REPLACED BACKSHELL FOR CONNECTOR 201WL-A IAW A320 ES PM 20-33-45. OPS CHECK TO BE COMPLETED ON CUSTOMER WORK CARD #18 -2373-1-7907 SEQ #108 IDT ADD SDR CALA2019120702153Wire Harness · damagedAAR NR 9031773 SUPPORT TASK L-76 DOT 008. EMERGENCY LIGHT HARNES S DAMAGED SEAT ROW 23 ABC REMOVED AND REPLACED DAMAGED EMERGENCY LIGHT HARNESS SEAT ROW 23 ABC IAW A320 ESPM 20-33-22PB 0201 CONFIG 01 AND NAT WIRE AND RA CEWAY DRAWING 40N00648, OPERATIONAL CHECSDR CALA2019112862083Pressure Panel · crackedREF AAR DLH N/R 9031510, LH SIDE PRESSURE PANEL BETWEEN FR35-36 HOLES 4 AND 13 HAVE CRACK INDICATIONS. CONTACT ENGINEERING FOR REPAIR INSTRUCTIONS BEFORE NEXT FLIGHT ACCOMPLISHED INTERIM REPAIR PER PART 1 OF ECRA 5331-02510. DIP L OGPAGE TO READ AS FOLLOWS, ASDR CALA2019112862082Window Frame · crackedREF AAR DLH N/R 9031350, ROTO PROBE INSPECTION SHOWS CRACK INDIC ATION AT WINDSHIELD SIDE POST UPPER ATTACHMENT, LH SIDE. HOLE ID ENTIFIED AS #3 LHS. ACCOMPLISHED INTERIM REPAIR PER PART 1 OF ECRA 5331-02523. DIP L OGPAGE TO BE CREATED TO READ AS FOLLOWS, ACCOSDR CALA2019112542053Frame · crackedREFERENCE AAR DLH N/R 9031163 & 9031164, ROTO PROBE INSPECTION S HOWS CRACK INDICATION AT DOUBLE JOGGLE, RH SIDE, FRAME 16 AT DOO R STOP #7, HOLES 4 AND B ACCOMPLISHED INTERIM REPAIR PER PART 1 OF ECRA 5311-02316 ON HOL ES 4 AND B AT RH FRAME 16 DOOR STOP #7 DSDR CALA2019112532032Threshold · corroded(A3NB-53-3-6299) R2 DOOR SURROUND LOWER STR 22-23 FR 66-68. UNDE RSIDE OF DOOR THRESHOLD HAS CORROSION. MARKED ON TOP. REFER TO A AR N/R: 9031514. REPLACED R2 THRESHOLD AT FR 66-68 IAW A320 SRM 51-423-11-801. RT ESTORED SURFACE PROTECTION IAW A320 SRM 51-75-12SDR CALA2019112532031Threshold · corroded(A3NB-53-3-6299) L2 DOOR SURROUND LOWER STR 22-23 FR 66-68. UNDE RSIDE OF DOOR TYHRESHOLD HAS CORROSION. MARKED ON TOP. REPLACED L2 DOOR THRESHOLD FR66-68 IAW A320 SRM 51-42-11-801.3 R ESTORTED SURFACE PROTECTIONB IAW A320 SRM 51-75-12-801.SDR CALA2019061700974Bolt · missingPDA 2 FOUND NLG TORQE LINK CENTER CONNECT PIN/ BOLT MISSING. (COVERED ON ORIGINAL LOG PAGE 3496551) MAINTENANCE HAS LOCATED THE MISSING BOLT. ITEM WILL BE CORRECTED ON ORIGINAL LOG PAGE 3496551 CENTER PIN REPLACED ON ORIGINAL LOG PAGESDR CALA2018102902222Pressure Switch · faultyG ENG 1 PUMP LO PR DISPLAYED ON UPPER ECAM SCREEN. - HYD HYD PUMP 31-2914-9-9003, AMM 29-11-51. FURTHER TSM REF 29-11-00- 810-804. BERG TOMC FAILING. NEEDS NEW SWITCH REF TSM TASK 29-11-00-810-804. FOUND PRESSURE SWITCH1074GK REMOVED AND REPLACED NR 1 ENG PUSDR CALA2018011900247Panel · delaminatedLEFT OVERWING EMERGENCY SLIDE PANEL 193AT HAS DELAMINATION ON AFT LOWER CORNER. REMOVED AND REPLACED THE SLIDE PANEL IAW AMM 25-62-42-000-001, AND 25-62-42-400-001-A.SDR CALA2017091103153Battery · no testRIGHT OVERWING EMERGENCY LIGHT BATTERY DID NOT PASS A BITE CHECK. REPLACED THE BATTERY AND PERFORMED BITE CHECK IAW AMM 33-51-00-710.SDR CALA2017041400984Unknown · smokeBEHIND FIRST CLASS SEATS 3AB. A PUFF OF SMOKE NOTED IN CABIN VISUALLY WITH ELECT SMELL PERFORMED FORM 46-6020 AND INSPECTION AND CHECK IAW 05-51-10-200 -801C1. INSPECTED AREA AND FOUND NO ELECTRICAL ISSUES WITH ANY OF THE SEAT ELEC UNITS. CHECK ALL CONNECTIONSDR CALA2016120901062Battery Pack · no testDURING EMERGENCY LIGHT TEST BATTERY FAULT LEFT MESSAGE. REPLACED BATTERY PACK IN LEFT POWER SUPPLY. OPS CHECKED GOOD.SDR CALA2013103092515Cone · crackedNR 2 ENG EXHAUST CONE HAS 4.5" CRACK IN ZONE 1 AT 4 O'CLOCK POSITION. STOP DRILLED CRACK IAW AMM 78-11-12-200-011-C.SDR CALA2013090490983Check Valve · faultyGREEN HYDRAULIC RESERVOIR PRESSURE SYSTEM TROUBLESHOOTING - CHECK OF PRESSURE LINES FOR INTEGRITY-LEAKS. REMOVE SEAT ROWS 22-24 ABC, REMOVED FLOOR PANEL 241LF, FOUND CHECK VALVE 1388GM & REMOVE CHECK VALVE FROM MANIFOLD. APPLY EXT AIR PRESSURE AT 50 PSI THRSDR CALA2013082990841B-Nut · looseG RESERVOIR LOW AIR PRESSURE DISPLAYED ON UPPER ECAM SCREEN. FOUND 'B'-NUT LOOSE AT RESERVOIR PRESSURE GAUGE SERVICED SYSTEM LIGHT OUT AT UPPER ECAM SCREEN. OPERATION CHECKED GOOD IAW MM.SDR UALA2013051303313Proximity Switch · inoperativeLEFT AFT SLIDE INDICATION INOPERATIVE ON DOOR OXYGEN SYS ECAM PAGE. SLIDE INDICATION SHOWED ARM AT THE GATE. IAW CREW DOOR 2L SLIDE ARMED INDICATION OUT IN CRUISE AND REARMED ITSELF ON DESCENT THRU 15,000 MSL. CABIN PRESS DELTA 4.8 PSI CABIN ALT 3100' -ADJUSDR UALA2013040802350Unknown · unknownEMERGENCY EXIT LIGHTS, NO SMOKING SIGN, CABIN LIGHTS ON BRIGHT AND SEAT BELT LIGHT ALL STUCK ON. PERFORMED CIDS RESET AND OP CHECK THRU CFDS PER AMM 23-73-00-740-005-A. OP CHECKED NS FSB LIGHTS PER AMM 23-73-63-400-002-A, ALSO OP CHECKED EMERGENCY LIGHTS PERSDR UALA2013040302171Placard · wrong partLEFT FWD OVERWING EMERGENCY EXIT DOOR HAS THE WRONG PLACARD ON DOOR. REMOVED AND REPLACED PLACARD.SDR UALA2013031801643Power Supply · faultyEMERGENCY SYS TEST FAULTED, EPSU INT LOAD EMERGENCY L. REPLACED EPSU AT 11WL. OP CHECKED GOOD.SDR UALA2013030601330Plate · wornNR 1 PYLON CNA ANTI CHAFING PLATE WORN AT RIB 5. INSTALLED ANTI-CHAFING PLATE PER SRM 54-51-12 FIG 202.SDR UALA2013012800500Strap · missingCOCKPIT CRASH AXE LOWER RETAINING LEATHER STRAP MISSING. REPLACED LOWER STRAP.SDR UALA2012122407370Hydraulic Line · leakingCREW REPORTS GREEN HYD QTY RESERVOIR LOW LEVEL. REMOVED AND REPLACED HYD LINE REF IPC 29-11-06-02L ITEM 260 PAGE 14 NO LEAKS NOTED. SERVICED GREEN HYD TO FULL.SDR UALA2012121707275Spring · deformedRIGHT NOSE GEAR DOWN LOCK SAFETY SPRING SHOWS SIGNS OF UNUSUAL DEFORMATION. UPPER COILS DO NOT MEET MINIMUM ENGAGEMENT ON RETAINER OF TWO WRAPS. ISSUE IS ON RT SPRING UPPER COILS. REPLACED RIGHTT NLG LOCK SPRING.SDR UALA2012121007157Nose Cowl · crackedINLET COWL INNER SURFACE 6:00 7 INCH CRACK THROUGH 9 RIVET HOLES. REPLACED NR 2 NOSE COWL FOR CRACKS.SDR UALA2012112606755Battery · failedFWD LEFT EPSU BATTERY FAILS EMERGENCY LIGHT TEST. REPLACED BATTERY IAW MM, TESTS GOOD.SDR UALA2012111906633Starter · faultySPARKS FROM FRONT OF ENGINE 2 DURING START. COCKPIT INDICATIONS NORMAL. MAINT ATTEMPTED AUTO START AND START VALVE MANUAL START WITH NO ROTATION. WILL NEED TO REPLACE START VALVE AND STARTER PER MM. REPLACED THE STARTER AND START VALVE PER MM. ACP FUNCTIOSDR UALA2012100805707Unknown · odorFOUL ODOR IN CABIN ELECTRICAL PERHAPS. INSPECTED E AND E COMPARTMENTS AND PITS CABIN SEEMED TO HAVE URINE TYPE SMELL. DISCONNECTED PC AIR RAN PACKS CABIN SMELLS NORMAL.SDR UALA2012071703848Oxygen Mask · failedFIRST OFFICERS OXYGEN MASK DOES NOT REPRESSURIZE AFTER SELF TEST. REPLACED FIRST OFFICERS OXYGEN MASK STOWAGE BOX, LEAK CHECKED GOOD. OPS CHECKED NORMALSDR UALA2012071603815Battery · no testPERFORMED EMERGENCY LIGHT TEST PER 3SVC, FOUND EPSU BATTERY FWD LT DISPLAYED. REPLACED BATTERY, TESTED NORMAL.SDR UALA2012060303063Nut · looseSEAT BACK LOOSE, ROCKING AT 24C. FOUND JAM NUT LOOSE ON HYDRO LOCK, OPS CHECKED NORMAL. OK FOR SERVICE.SDR UALA2012051002688Fadec · malfunctionedFADEC A FAULT DISPLAYED ON UPPER ECAM SCREEN. RESET FADEC AND EIU. SYSTEM OPS NORMAL.SDR UALA2012032901973Connector · not seatedUNABLE TO UPLOAD WATER. :WHEN OPENING AFT PANEL FILL VALVE THE FWD DUMP VALVE THE FWD SVC PANEL DRIVES TO OPEN AND DUMPS THE WATER RENDERED POTABLE WATER SYS INOP PER MEL 38050. RESET CB'S AND RESEAT CONNECTOR OF 16MA MOTOR GRD CHK NORM. RETURNED SYS BACK TSDR UALA2011090904889Packing · damagedCREW REPORT: ON WALK-AROUND OBSERVED OIL DRIPPING PUDDLING UNDER ENG 1. SAMC TEXT: FBO TO EVALUATE SOURCE AND TYPE OF FLUID AND REPORT FINDINGS TO SAMC-EMC. FBO FOUND PACKING DAMAGED ON PRESSURE LINE TO NR 5 BEARING CAVITY MATING SURFACE. PIX POSTED ESN VSDR UALA2011082904631Switch · brokenCAPTAIN'S OXYGEN MASK PRESS TO TEST SWITCH BROKE OFF. REPLACED CAPT OXYGEN MASK BOX PER MM, OPS CHECKS GOOD.SDR UALA2011082204469Smoke Detector · false activationSMOKE LAV DET FAULT. REPLACED LAV 'A' SMOKE DETECTOR, TESTED OKAY.SDR UALA2011081204258Computer · faultyELAC 2 FAULT. REPLACED ELAC 2 PER AMM. TESTS OKAY. ACCOMPLISHED CAT3 TEST. TESTS SATISFACTORILY.SDR UALA2011071203474Bracket · bentFIRE EXT BRACKET BADLY BENT BEHIND LAST ROW SEATS RIGHT SIDE. REPLACED BRACKET.SDR UALA2011070103263Trim Panel · looseSEAT 27D HAS EXPOSED METAL ON FLOOR. SECURED METAL TRIM ON LOWER DADO PANEL AT SEAT 27F, (NOT 27D).