N471UP
Service difficulty reports · 168
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N471UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N471UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2026073130927Window · failedFO FWD WINDOW STARTED ARCING WE SHUT OF FWD WINDOW HEAT OUTER WINDOW SHATTERED RAN QRH PROCEDURE AND CONTINUED FLIGHT NO SIGNS OF LEAK OR WINDOW BEING DEFORMED. C/W REMAINING STEPS OF R1 WINDSHIELD INSTALL IAW AMM 56-11-01-424-015. OPS CK GOODSDR IPXA2026073030927Window · arcedFO FWD WINDOW STARTED ARCING WE SHUT OF FWD WINDOW HEAT OUTER WINDOW SHATTERED RAN QRH PROCEDURE AND CONTINUED FLIGHT NO SIGNS OF LEAK OR WINDOW BEING DEFORMED.SDR IPXA2025072576091Strap · corrodedMAJOR REPAIR, CORROSION FOUND ON STRAP AT AUXILARY POWER UNIT AIR INLET DOOR SURROUND STRUCTURE STA Y=1825 AND BETWEEN S-3R AND S-6R INSTALLED REPAIR PARTS, STRAP (1), STRAP (2), STRAP (7), FILLER (3) AND FILLER (4) AT AUXILARY POWER UNIT AIR INLET DOOR SURRSDR IPXA2025072442329Strap · corrodedMAJOR REPAIR, CORROSION ON APU INLET FWD NUT PLATE STRAP INSTALLED STRAP P/N: 148N3138-20, BTCH NO. 0004410942 AT APU INLET DOOR SURROUNDING STRUCTURE IAW B757-200PF SRM 51-40-02-0G-0.SDR IPXA2024012959843Unknown · smokeAFTER ENG START , OVERWHELMING FUEL/ OIL SMELL ON FLIGHT DECK. SMOKE/FUMES MEMORY ITEMS COMPLETE. O2 CHECK COMPLETE. SHUT DOWN THE ENGINES TOWED BACK IN ON O2. INSPECTED BOTH LH & RH PACKS PER B757 AMM 21-51-00-216-001 AND BOTH LH & RH ENGINES FOR LEAKS AND SISDR IPXA2023111357959Door · chafed*** SUPPLEMENTAL SDR *** FAULT:CREW ENTRY DOOR CHAFING AT OUTTER SKIN LOWER AREA (4 E/A) DOT119-006 CLEANED SKIN LOWER AREA IAW SOPM 20-30-03 NO CHAFING, NO DAMAGE WAS FOUND. REVIEWEDSDR IPXA2023100957959Unknown · unknownFAULT:CREW ENTRY DOOR CHAFING AT OUTTER SKIN LOWER AREA (4 E/A) DOT119-006 CLEANED SKIN LOWER AREA IAW SOPM 20-30-03 NO CHAFING, NO DAMAGE WAS FOUND. AUDIT COMPLETE. OPENSDR IPXA2023061198722Slat · unknownREF T3F18E001Y1WS ANDT3F18E001Y5M1 - ACCOMPLISH AN HFEC ON THE NO. 3 SLAT REPAIR ACCOMPLISHED PER EO-86906-REQ2 AS DIRECTED BY QC COMPLIED WITH EO-86906-REQ3, REF BARCODE T3F18E001Z50R FOR ALL AMT/QC SIGNOFFS OF REPAIR ACCOMPLISHED.SDR IPXA2023012490217Warning Message · false activationTE EDGE FLAP DISAGREE EICAS AND LIGHT WHEN SELECTING FLAPS FROM 20 TO 25. DECLARED EMERGENCY AND MADE NORMAL LANDING. OPERATED FLAPS/SLATS IN NORMAL AND ALTERNATE WITH NO FAULTS OR LIGHTS RAN BITE CHECK AND CHECKED FSEU NO CURRENT OR PREVIOUS FAULTS OK FOR SSDR IPXA2021101574986Floor Panel · damagedINSPECTION TYPE:SEGPNL 241XCF DAMAGEDFABBED PNL PER SREO B757-5320-9692-KSDR IPXA2021101474954Floor Panel · damagedINSPECTION TYPE:SEGPNL 242XAF DAMAGEDFABBED PER SREO B757-5320-9692-KSDR IPXA2021101474953Floor Panel · damagedINSPECTION TYPE:SEGPNL 242XBF DAMAGEDFABBED PER SREO B757-5320-9692-KSDR IPXA2021101474952Floor Panel · noneINSPECTION TYPE:SEGPNL 241XEF DAMAGEDÏ¿½FABBED PER SREO B757-5320-9692-KSDR IPXA2021101474951Floor Panel · damagedINSPECTION TYPE:SEGPNL 242XDF DAMAGEDFABBED PER SREO B757-5320-9692-KSDR IPXA2021101474950Floor Panel · damagedINSPECTION TYPE:SEGPNL 242XEF DAMAGEDFABBED PER SREO B757-5320-9692-KSDR IPXA2021102675350None · crackedINSPECTION TYPE:SEGPANEL 119AF IS PEELINGFABRICATED REPLACEMENT PANEL PER DWG 284N1033 USING 4417-41110133-9 BATCH# J5678456 PER GMM 09-10-03-01SDR IPXA2021102575317None · crackedINSPECTION TYPE:SEG#1 ENGINE AFT OF AFT MOUNT IB BRACKET SUPPORT IS CRACKEDREMOVED CRACKED BRACKET AND INSTALLED REPLACEMENT BRAQCKET SUPPORT PER SRM 51-40-02-0GSDR IPXA2021102475271None · crackedINSPECTION TYPE:SEGMDCC AT STA 1056 & LBL40 FLOOR PANEL SUPPORT STRUCTURE IS CRACKEDREMOVED AND INSTALLED REPLACEMENT 144N5005-3 FLOOR SUPPORT PER SRM 51-40-02-0GSDR IPXA2021102375234None · crackedINSPECTION TYPE:CRH WING SLAT #9 OB TRACK PANEL COVER IS CRACKEDREMOVED AND INSTALLED REPLACEMENT COVER PER SRM 51-40-02-0GSDR IPXA2021102375233None · crackedINSPECTION TYPE:CRH WING SLAT #9 I/B TRACK PANEL COVER IS CRACKEDREMOVED AND INSTALLED REPLACEMENT COVER PER SRM 51-40-02-0GSDR IPXA2020062967028Lamp · inoperativeEXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS. OPS NORMAL AW MM 33-51-06SDR IPXA2020022652511Connector · not seatedINSPECTION TYPE:N/ADIVERSION - GEAR DESAGREE EICAS MSG UPON RAISING GEARC/W PSEU BITE PER FIM 32-09-03-815-804 FIG 103 FOUND SEVERAL FAULTY SENSORS. INSPECTED NOSE GEAR & FOUND CONNECTOR D-40488P NOT SEATED PROPERLY. SECURED CONNECTOR & C/W NOSE GEAR SWING PERSDR IPXA2020022152340Warning Light · illuminatedEMERGENCY DECLARED DUE TO GEAR DISAGREE EICAS & GEAR LIGHT, IN ADDITION DOOR LIGHT & EICAS AND NOSE GREEN LIGHT ILUMINATED WITH GEAR HANDLE. UNUSUAL AIRCRAFT VIBRATION & NOISE. REF MEL 32-30-1. LANDING GEAR ACT SYS. VMO SW SELECTED 270. DMP 32-30-1, LANDING GSDR IPXA2020010250581Probe · failedINSPECTION TYPE:N/A*** ATB *** TAT PROBE FAILURE AT *31,000 FT, LOW AP AUTOTHROTTLES COMMAND SPEED, MAU CONTROL. PERFORMED FIM TASK 22-02-00-810-801-001 & FIM TASK 30-33-00-815-802 WITH NO HARD FAULTS NOTED.REPLACED RH TBT PROBE CURRENT SENSOR & PERFORMED OPS SDR IPXA2019111328922Panel · damagedINSPECTION TYPE:SVWING DRY BAY PANEL #632DZ HAS COMPOSITE DAMAGE.REPAIRED WING DRY BAY PANEL # 632DZ IAW VT-SAA EA 757-5720-01-A7948 REV. I/R. (MAJOR)SDR IPXA2019110878746Floorbeam · wornINSPECTION TYPE:C14 MAIN CARGO DECK BEAMS AT STA 879 HAVE DEEP WEAR MARKS FROM WRONG HARDWARE INSTALLED IN FLOORBOEARD SUPPORT. DOT # 29-211. REMOVED DISCREPANT FILLER, WHICH HAS WEAR MARKS, FORM EXISTING REPAIR. 2. FABRICATE AND INSTALL NEW FILLER PER EA 757-SDR IPXA2019030639780Blower · inoperativeINSPECTION TYPE:NA CAPTS EVAS BLOWER CHECK TEST BUTTON INOP. REMOVED AND REPLACED CAPT'S EVAS PACK PER AMM 25-69-00-401 IPC 25-60-00-401.SDR IPXA2018062230953Window · failedAT 17,000 FEET, DURING DESECNT, THE FIRST OFFICER'S R1 WINDOW SHATTERED. EMERGENCY DECLARED, AND LANDED. R & R THE R1 WINDOW IAW MM 56-11-01-424.SDR IPXA2017062918758Liner · corrodedLEFT ENGINE LP COMPRESSOR FROM CASE HAS NUMEROUS AREAS OF CORROSION UNDER ROTOR PATH LINING. REMOVED CORROSION AND FOUND A LARGE AREA OUT OF LIMITS IAW AMM 72-34-10-300-80.SDR IPXA2017011812888Smoke Goggles · crackedSUPERNUMERARY SEAT SMOKE GOGGLE LENS CRACKED. R&R'D SMOKE GOGGLE PER AMM 25-64-00-202-021.SDR IPXA2017010412390Lamp · inoperativeEMERGENCY EXIT UN ARMED ANNUC LT HAS 1 LAMP INOPERATIVE. REPLACED THE LAMP IAW MM 33-16-02-962-001. OPS CHECKED NORMAL..SDR IPXA2016021299303Lamp · inoperativeEXTERIOR EMERGENCY LIGHT INOPERATIVE, EGRESS LIGHT, REPLACED THE LAMP IAW AMM 33-51-06. OPS CHECKED NORMAL.SDR IPXA2014120184964Lamp · inoperativeEXTERIOR EGRESS, EVAC SLIDE, LAMP INOPERATIVE. TROUBLESHOT TO A FAULTY LAMP ASSY. R & R SAME. OPS CKS GOOD REF AMM 33-51-06.SDR IPXA2014091984363Electronic Unit · inoperativeT/E FLAP DISAGREE MESSAGE ON APPROACH. EMERGENCY DECLARED. PERFORMED FSEU BITE PROCEDURE REF AMM 27-51-00-815. R & R FSEU AND OPS CHECKED GOOD IAW AMM 27-51-01 P201.SDR IPXA4583716Lamp · inoperativeLAMP INOPERATIVE OVERHEAD PANEL. EMERGENCY LIGHT UNARMED INDICATOR. REPLACED LENS CAP IAW SWDM 20-84-14. OPS CK GOOD.SDR IPXA2014012201508Floor Panel · damagedINSPECTION C8S4, MAIN DECK FLOOR PANEL 252XTF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012201507Floor Panel · delaminatedINSPECTION C8S4, MAIN DECK FLOOR PANEL 231XFF IS DELAMINATED. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012201506Floor Panel · damagedINSPECTION C8S4, MAIN DECK FLOOR PANEL 232XJF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001498Floor Panel · damagedDURING C8S4 INSPECTION, MAIN DECK FLOOR PANEL 251XBF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001497Floor Panel · damagedDURING C8S4 INSPECTION, MAIN DECK FLOOR PANEL 252XSF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001496Floor Panel · damagedDURING C8S4 INSPECTION, MAIN DECK FLOOR PANEL 242XLF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001480Floor Panel · delaminatedDURING C INSPECTION, MAIN DECK FLOOR PANEL 231XJF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001479Floor Panel · damagedDURING C INSPECTION, MAIN DECK FLOOR PANEL 251XPF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001478Floor Panel · puncturedDURING C INSPECTION, MAIN DECK FLOOR PANEL 232XHF PUNCTURED ON UPPER SURFACE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001477Floor Panel · damagedDURING C INSPECTION, MAIN DECK FLOOR PANEL 251XLF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001476Floor Panel · damagedDURING C INSPECTION, MAIN DECK FLOOR PANEL 241XLF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001475Floor Panel · damagedDURING C INSPECTION, MAIN DECK FLOOR PANEL 231XCF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001474Floor Panel · damagedDURING C INSPECTION, MAIN DECK FLOOR PANEL 231XEF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014012001472Floor Panel · damagedDURING C INSPECTION, MAIN DECK FLOOR PANEL 222XBF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2014012001471Floor Panel · damagedDURING C INSPECTION, MAIN DECK FLOOR PANEL 252XEF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.
Back to N471UP