N472UA
Service difficulty reports · 102
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N472UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N472UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013062404374Line · leakingFOUND UPPER FUEL OIL COOLER LINE LEAKING. SECURED LINE NO LEAKS FOUND. RAN ENG 5 MIN NO LEAKS NOTED.SDR UALA2013050903238Stringer · corrodedFORWARD CARGO BAY STRINGER 43 LEFT, HAS SPOT CORROSION BETWEEN FR 24 & FR 28. CORROSION OUT OF LIMITS. REPLACED STRINGER IAW SRM 51-42-11 PG 7. MAJOR REPAIR.SDR UALA2013031501586Computer · faultyELAC 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. AT FL 360. BUMP IN FLIGHT PATH WITH FAULT. REPLACED ELAC 1, OPS CHECK OK PER MM 27-93-00-710-001A AND ACCOMPLISHED CAT III CHECK, ALL OK.SDR UALA2013022201072Acm · leakingLEFT WING BLEED LOOP, FLT DIVERTED. FOUND SEAL LEAKING WHICH IS PART OF VALVE 644-9042. ON CHECK OF THE AIR SYS, MX FOUND ACM GASKET LEAKING. ON ATTEMPTED REPAIR OF GASKET DISCOVERED THAT HELICOIL ON ACM FAILED. REPLACED LEFT ACM IAW AMM. NO LEAKS NOTED, SDR UALA2013021100825Seal · unsecureRUBBER SEAL HANGING FROM NR 2 ENGINE THRUST REVERSER. ABLE TO EXTEND THE THRUST REVERSER SLEEVE MANUALLY AND RESEAT THE BULB SEAL. THRUST REVERSER RETURNED TO NORMAL FORWARD THRUST POSITION. HCU IS IN NORMAL OPS POSITION. FAN COWL IS CLOSED AND PROPERLY SESDR UALA2013020500720Nut · looseUNKNOWN VIBRATION. NOSE LANDING GEAR LT AFT DOOR ROTATING ROD SPANNER NUT LOCK WASHER BROKEN, AND BENT LOCKING TABS WHEN TORQUING NUT. REPLACED LOCKING TAB PER MM AND REINSTALLED NLG AFT DOOR. DOOR ADJUSTMENT AND GEAR OPERATION NORMAL.SDR UALA2013011700293Controller · faultedLEFT WINDOW ECAM MESSAGE. MESSAGE "ANTI ICE L WINDSHIELD". MESSAGE IS INTERMITTANT. REPLACED CAPTAIN'S WINDSHIELD HEAT CONTROLLER, OPS TEST GOOD IAW AMM 30-42-34. CLEARED FAULTS AND MESSAGES.SDR UALA2012121707256Battery · failedEMERGENCY LIGHT TEST FAILED, "EPSU BATTERY EMER L" DISPLAYED. RPL BATTERIES EPSU LEFT AND AFT. EMERGENCY LIGHTS TEST OK. PCN-565-0033 PART NBR 3214-31 REF IPC-33-51-38-01B ITEM 010A.SDR UALA2012121207165Oxygen Mask · failedCREW REPORT: PRESSURIZATION FAILURE, PAX MASKS DEPLOYED. ACCOMPLISHED THE REMOVAL OF THE FLIGHT ATTENDANT O2 MASKS AND THE DEPLETED O2 GENERATORS.SDR UALA2012102606157Wire Harness · faultyEMERGENCY EXIT LIGHTS AT SEATS 7-8-10-25-26-27-32 INOP. FOUND SEATS 7-8-10-25-26-27 DISCONNECTED AT BULKHEAD. THIS DEFERRAL IS FOR SEAT 32 EEL LT ONLY. REPLACED WIRE HARNESS FOR EM LIGHT AT 32C. OPS CK NORMAL.SDR UALA2012081004344Structure · damagedNR 1 NACELLE MISSING 2 RIVETS BY TRAILING EDGE. MISSING RIVETS ARE JUST ABOVE 2 DRAIN TUBES ON SAIL TAIL. REPLACED RIVETS.SDR UALA2012080804296Girt Bar · contaminatedR2 DOOR DISARMED ECAM, RETURNED TO FIELD. OPENED DOOR AND FOUND CONTAMINATION IN GIRT FLOOR FITTING. REMOVED AND CYCLED ARMING LEVER REP. ALL INDICATIONS CHECKED GOOD.SDR UALA2012073004106Control Unit · malfunctionedPLANE NEEDS 10 UNITS TO THE LEFT TO TAXI STRAIGHT STRONG PULL TO RIGHT. REPLACED BCSU PER MT 32-004 AND DID MAINTENANCE ACTION 1-4.SDR UALA2012073004090Computer · failedFMGC 1 FAILURE, FLIGHT DIVERTED. FMGC 1 INOP, ATTEMPTED RESET NO JOY. REPLACED NR 1 FMGC, OPS CHECK OK AND ACCOMPLISHED CAT III CHECK, OK PER MM 22-97-00. ON PFR HAD FMG1-RMP1 INTERFACE FAULT, REPLACED NR 1 RMP, GND CHECK OK.SDR UALA2012021300830Light · inoperativeDURING EMERGENCY LIGHT TEST FOUND EMERGENCY LIGHT AT LT FWD OVERWING DOOR INOP AND L FWD ENTRY DOOR EMERGENCY LIGHT BATTERY. RELAMPED EMERGENCY LIGHT AT LT FWD OVERWING DOOR AND REPLACED ESPU BATTERY FWD LT DOOR, OP CHECKED OKAY.SDR UALA2012011200258Control Valve · malfunctionedGROUND RETURN AND CANCELLATION DUE TO INOPERATIVE PACK. PACK 1 FAULT LIGHT INOP - AIR AIR. PROG TEXT: - ITEM ROLLED FORWARD. NR 1 PACK FLOW CONTROL VALVE REPLACED AND REPLACED SOLENOIDS 7170HM1, 10HA1. SWAPPED BOTH SDACS, PERFORMED CATIII CHECK. ACFT PACSDR UALA2011101805644Cone · crackedNR 1 ENGINE EXHAUST CONE CRACKED. REPLACED NR 1 ENGINE EXHAUST CONE PER AMM, CHECKED OKAY.SDR UALA2011072903913Harness · kinkedRT MAIN GEAR UNSAFE MOMENTARY FLICKER ON TAXI IN. SUSPECT WIRE SHORT BTWN LGCIU 1 PIN AA8D AND LIGHT BOARD 9LP AND FWC 1 OR FWC 2. FOUND LANDING GEAR HARNESS KINKED AND DAMAGED APPROX 10 INCHES FROM PROX SENSOR 14GA. OLD HARNESS UNSECURED, LAYING ON MLG FORSDR UALA2011070103238Fuel Control · faultyCREW REPORTS: APU WILL NOT START. PER SAM RESET L41 & L42 CB'S NO HELP, APU S-DOWN REPORT SHOWS NO FLAME IGN UNIT (8030KM) AND FCU (8022KM). INOP'D APU PER MEL4910B, CREW PULLED AND COLLARED 'L41 & L42' ON PANEL 121VU USING DEF ER STICKERS, OPB GUS NOTIFIEDSDR UALA2011062703135Wire Harness · chafedSPARKS REPORTED IN FLIGHT SHOOTING FROM UNDER SEAT ROW 21A AND 21B. FLT CREW REPORTED A CHAFED WIRE UNDER THE SEAT. REMOVED DAMAGED SECTION OF PAX. ENTERTAINMENT HARNESS. SECURED CONNECTOR AND STOWED FROM 20ABC AND 21ABC. RAN ENGINES, CHECKED AREA: NO FURTHESDR UALA2011011900312Fuel Nozzle · leakingSTRONG ODOR OF FUMES IN COCKPIT AND CABIN. WORSE TOWARDS BACK OF CABIN. ODOR IS RAW FUEL NOT FUMES. FOUND FUEL LEAKING FROM FUEL NOZZLE AT 9 O'CLOCK POSITION. RESEATED NOZZLE ASSY AND RESEATED FUEL NOZZLE. RAN APU NO LEAKS. REPLACED BOTH RECIRC FILTERS ANSDR UALA2010092403546Power Supply · faultyEPSU TEST GIVES "EPSU INTERNAL LOAD L" MESSAGE. REPLACED EPSU AND BATTERY PER MT. TESTS OKAY.SDR UALA2010090203226Blade · damagedBIRDSTRIKE ON TAKE OFF, RTFL. LANDED AT GW 152.1. IAW CREW, DID NOT EXCEED VERTICAL SPEED (V-S) OF MORE THAN 360 FT-MIN. EXTENDED AND SMOOTH LANDING. ACCOMPLISHED OVERWEIGHT CHECK, NO DMU MESSAGE, OR DEFECTS NOTED. ACCOMPLISHED BIRD STRIKE INSP REF MM, NO DSDR UALA2010060801993Floor Support · corrodedFWD & AFT CORROSION. UNDER CABIN FLOOR PANEL STRUCTURES ARE CORRODED AT STA FR 16 TO FR 23 FROM LBL 12 IN TO RT SIDEWALL. ALL FLOORBOARDS INSTL'D. ACCOMPLISHED AT SMB ON WU R1879N.SDR UALA2010052001704Bolt · sheared(2) SHEARED BOLTS FOUND AT FLOORBEAM EXPANSION JOINT FWD OF C47 FRAME. REPLACED ALL (6) BOLTS, NDT AT RMD. BOLTS LOC, NO CRACKS. TASK DONE ON SMB W-U H7313S AND H7312S. CREATED ENTRY FOR REFERENCE AND HISTORY.SDR UALA2010011100139Lanyard · underservicedDOOR 2R SLIDE RAFT GIRT LANYARD UNDERSERVICED. CORRECTED ROUTING OF LANYARDS.SDR UALA2010011100138Lanyard · underservicedDOOR 1R SLIDE RAFT GIRT LANYARD UNDERSERVICED. CORRECTED LANYARDS. FOUND LANYARDS INSTALLED IAW MM.SDR UALA2009072902276Bypass Valve · leakingGREEN SYSTEM HYD LOSS, RTFL. FOUND RIGHT MLG DOOR BYPASS VALVE LEAKING. REPLACED RT MLG DOOR GROUND OPENING BYPASS VALVE. OPS CHECK NORMAL. NO DEFECTS NOTED OR MESSAGES DISPLAYED.SDR UALA2009040800998Wire · brokenCABIN EMERGENCY LIGHT TEST FAILED, EPSU INT AND EXT LOAD AFT LEFT, BOTH FAULTS FLASHING ON PSU. FOUND POWER SUPPLY 13WL INTERNAL BITE INOP. REPLACED 13WL BITE NOW WORKS. CABIN EMERGENCY TEST STILL HAS SAME FAULTS. SUSPECT RIGHT AFT EMERGENCY SLIDE. FOUND SDR 2008UALA06035Outflow Valve · malfunctionedVENT SKIN VALVE FAULT, RTFL. FOUND 22HQ CONNECTOR PIN-INSULATION ISSUES. REPLACED SKIN AIR OUTLET VALVE. PUT VALVE AND CIRCUIT BREAKERS BACK TO NORMAL. OPS CHECKS OK.SDR 2008UALA05482Unknown · unknownMECHANICAL PROBLEM INCURRED. FLIGHT DIVERTED.SDR 2008UALA04124Oxygen Mask · leakingTHE 1ST OBS MASK, LEAKS. *S/D* HARNESS NOT INFLATING/LEAKING. REPLACED 1ST OBS MASK, OPS CHECKED OK.SDR 2008UALA04123Oxygen System · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). CREW COMMENTS: MASKS DOES NOT TEST PROPERLY. *S/D* O2 BOX LEAKING AND TEST SWITCH IS STICKING. REPLACED 10RN3, 3RD OCCUPANT OXY BOX. OPS CHECKED NORMAL.SDR 2008UALA04055Battery · no testEMERGENCY LIGHT TEST FAILED.SDR 2008UALA00442Lanyard · out of positionLANYARD FOR DOOR 2R IS NOT PACKED INTO SLIDEPACK AND EXTENDS ABOUT 2 FT. REINSTALLED LANYARD AND CHECKED SLIDE ARMING AND DISARMING POSITIONS, ALL NORMAL.SDR 2007UALA05329Sensor · faultyUPPER ECAM F-CTL SLATS LOCKED WING TIP BRK ON DURING 4 MILE FINAL. FPPU FAULTY (FEEDBACK POSITION PICK-OFF UNIT). RANG ALL ASSOCIATED WIRING FROM SFCC1 & SFCC2 TO FPPU 28CV. SWAPPED CONNECTORS ON FPPU 28CV AND IPPU 4CN, WAS ABLE TO RESET WTB AND RUN FLAPS-SSDR 2007UALA04860Skin · dentedDENT IN NR 1 SLAT LEFT INBOARD WING LOWER SURFACE ABOUT 14 INCHES FROM INBOARD EDGE OF SLAT. PANEL JUST AFT OF NR 1 SLAT LOWER SURFACE HAS A CRACK ABOUT 1.5 INCHES LONG AND AREA OF DENT AROUND CRACK IS ABOUT 2.5 INCH DIAMETER. DENT ON LOWER PANEL BEGINS ABOUSDR 2007UALA04456Power Supply · failedCABIN EMERGENCY LIGHTS TEST FAILS. FOUND EPSU FAILED. REPLACED THE EPSU, AND CYCLED FSB NO SMOKING SIGNS AND MASTER EMERGENCY LIGHT SWITCH. RAN EMERGENCY LIGHT TEST AT PANEL, SYSTEM CHECKED OK.SDR 2007UALA04207Oxygen System · reads lowCREW O2 LOW. 10-26-07 PRE SVC LEVELS WERE RECORDED AT 1500 PSI. NO INFO AVAILABLE AS TO SERVICE PERFORMED OR JUST AN INCORRECT PILOT ASSESSMENT.
SDR 2007UALA03948Transceiver · failedPREDICTIVE WINDSHEAR FAILED AGAIN. COULD NOT DUPLICATE ON GROUND, TESTED WINDSHEAR/AFS AND RAN CAT III TEST, ALL GOOD. REPLACED THE WEATHER RADAR TR AS PRECUATIONARY.SDR 2007UALA01774Fire Loop · unknownFIRE LOOP B FAULT DISPLAYED ON UPPER ECAM SCREEN, ENG 1. ALMOST THE ENTIRE LOOP B DETECTION CIRCUIT WAS REPLACED (LOOPS, FDU, FIRE HANDLE CONTROL UNIT). LOOP HAD STILL FAULTED UP UNTIL 6/27/07. NO REPEATS SINCE.SDR 2007UALA00954Sill · corrodedR2 DOOR SILL PLATE HAS CORROSION BEYOND LIMITS AT FRAME 68. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE & INSTALLED DOUBLER REPAIR.SDR 2007UALA00662Unknown · unknownRTFL DUE TO BLEED 1 & 2 EMAC FAULT ON CLIMB. RESET BMC, BLEED 1 RESTORED IMMEDIATELY FOLLOWED BY BLEED 2 IN FLIGHT. SUPPLEMENTAL DATA UPDATE ON ENGINE NR 1, BITE TEST INDICATED FAULT OF EITHER FAN AIR VALVE, CONTROL THERMOSTAT OR SENSE LINE. FOUND FILTER FOR CSDR 2006UALA02025Engine · failedNR 1 ENGINE FAILED DURING TAKEOFF RUN. REPLACED NR 1 ENGINE. FOUND FINE METAL SHAVINGS IN TAILPIPE. CAPT REPORTED BURNING ODOR IN CABIN. NO SMOKE. EGT, EPR SPIKED. FADEC MESSAGE, VSV VALVE FAILURE. NOTHING ON PFR. NR 1 ENGINE HAS METAL IN THE AFT FAN SDR 2006UALA01651Hydraulic System · malfunctionedRETURN TO FIELD DUE TO LOSS OF YELLOW HYDRAULIC SYSTEM. YELLOW SYSTEM PRESS AND QUANTITY ARE NORMAL FROM BOTH THE EDP AND THE PTU. REPLACED YELLOW SYSTEM TRANSDUCER AND SWITCH-TEMPERATURE [P/N TM113-1]. REPLACED THE YELLOW SYSTEM ELECTRIC HP CHECK VALVE [P/SDR 2006UALA01617Warning System · activatedAFTER DEPARTURE HAD A YELLOW SYS OVERHEAT MESSAGE. REPLACED YELLOW SYSTEM TEMP TRANSMITTER (3381GR), AND BLEED YELLOW SYSTEM. SERVICED SYSTEM AND RAN ENGINE APPROXIMATELY 20 MINUTES CYCLING FLIGHT CONTROLS, ALL CHECKED NORMAL.SDR 2006UALA01066Compressor · stalledCREW EXPERIENCED MOMENTARY ENG NR 2 STALL ECAM, COMPRESSOR STALL, CLIMBING THRU FL290. NO DEFECTS FOUND DURING TROUBLESHOOTING.SDR 2006UALA01102Bracket · brokenNR 1 LT SLIDE REMOVED FOR BROKEN BRACKET. PERMATURE FAILURE OF SUPPORT BRACKET. NR 1 LT SLIDE REMOVED FOR BROKEN BRACKET. REPLACED SLIDE.SDR 2006UALA01085Power Supply · faultyEMERGENCY LIGHT TEST, DETECTED THE FOLLOWING FAULTS: EPSU BATT EMER L, EPSU COMM FWD L AND EPSU COMM EMER R. REPLACED 11WL EPSU, LEFT OVERWING EPSU, EMERGENCY SYSTEM TEST OK.SDR 2006UALA00503Sill · corrodedR2 DOOR SILL HAS CORROSION AT NUT CLIP HOLE AT FRAME 66. TYPICAL UNDER FLOOR CORROSION. REPLACED FLOORBEAM ASSEMBLY.
Back to N472UA