N473MC
Service difficulty reports · 228
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N473MC' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N473MC' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2022042500385None · noneLH BS 900 MOST INNER ROW OF FASTENER HOLES AT TENSION TIE TO FRAME ATTACHMENT LOWER HOLE CRACK WAS FOUND ON FWD CHANNEL RUNNING UP AND DOWN THRU THICKNESS.(<P>STA 900 L/H TENSION TIE FWD CHANNEL 1EA FASTENER HOLE CRACK AREA REPAIRED IAW RI-53-00-15553 REV A</PSDR UIEA2022042500386None · noneRH BS 880 MOST INNER ROW OF FASTENER HOLES AT TENSION TIE TO FRAME ATTACHMENT LOWER HOLE CRACK WAS FOUND ON FWD CHANNEL RUNNING UP AND DOWN THRU THICKNESS.(<P>STA 880 R/H TENSION TIE FWD CHANNEL 1EA FASTENER HOLE CRACK AREA REPAIRED IAW RI-53-00-15553 REV A.</SDR UIEA2022042500387Shield · noneU/D - RH CREW DOOR FWD DRAIN SHIELD LOWER SUPPORT FOUND CORROSION(<P>U/D - STA 666 RBL 95" WL 310, RH CREW DOOR FWD DRAIN SHIELD LOWER CORROSION SUPPORT P/N : 65B25769-12 REPLACED AND INSTALLED IAW SRM 51-10-02 AND SRM 51-40-02.</P>)SDR UIEA2022042500388None · none#4 PYLON VALVE ACCESS PNL #482EL FOUND 2EA SCREW HOLE ELONGATED.(<P>#4 PYLON VALVE ACCESS PNL #482EL 2EA SCREW HOLE ELONGATED AREAS REPAIRED IAW RI-54-50-15536 REV A</P>)SDR UIEA2022042500389None · none#3 PYLON VALVE ACCESS PNL #472ER FOUND 1EA SCREW HOLE ELONGATED(<P>#3 PYLON VAVLE ACCESS PNL #472ER 1EA SCREW HOLE ELONGATED AREAS REPAIRED IAW RI-54-50-15536 REV A</P>)SDR UIEA2022042500390None · noneM/D - R3 DOOR AFT CUTOUT UPPER CORNER FOUND CORROSION(<P>RH DOOR 3 CUTOUT AFT UPPER CORNER INBOARD FACE CORROSION AREA REPAIRED IAW RI-53-40-15538 REV A</P>)SDR UIEA2022042600392Panel · none#2 PYLON VALVE ACCESS PNL #462EL FOUND 2EA SCREWS HOLES ELONGATED(<P>#2 PYLON VALVE ACCESS PNL #462EL P/N : 311U2060-137 FABRICATED AND REPLACED IAW RI-54-50-15536 REV A</P>)SDR UIEA2022042600394None · noneR/H BS 880 MOST INNER ROW OF FASTENER HOLES AT TENSION TIE TO FRAME ATTACHMENT UPPER HOLE CRACK WAS FOUND ON FWD CHANNEL RUNNING UP AND DOWN THRU THICKNESS(<P>STA 880 RH TENSION TIE FORWARD CHANNEL AND FORWARD DOUBLER FASTENER HOLES CRACK AREA REPAIRED IAW RI-SDR UIEA2022042600395None · noneR/H BS 900 MOST INNER ROW OF FASTENER HOLES AT TENSION TIE TO FRAME ATTACHMENT UPPER HOLE CRACK WAS FOUND ON FWD CHANNEL RUNNING UP AND DOWN THRU THICKNESS(<P>STA 900 RH TENSION TIE FORWARD CHANNEL AND FORWARD DOUBLER FASTENER HOLES CRACK AREA REPAIRED IAW RI-SDR UIEA2022042600396None · noneL/H BS 880 MOST INNER ROW OF FASTENER HOLES AT TENSION TIE TO FRAME ATTACHMENT UPPER HOLE CRACK WAS FOUND ON FWD CHANNEL RUNNING UP THRU THICKNESS(<P>STA 880 LH TENSION TIE FORWARD CHANNEL AND FORWARD DOUBLER FASTENER HOLES CRACK AREA REPAIRED IAW RI-53-00-155SDR UIEA2022042600397None · noneL/H BS 900 MOST INNER ROW OF FASTENER HOLES AT TENSION TIE TO FRAME ATTACHMENT UPPER HOLE CRACK WAS FOUND ON FWD CHANNEL RUNNING UP AND DOWN APPROX 0.030 AND 0.040".(<P>STA 900 LH TENSION TIE FORWARD CHANNEL AND FORWARD DOUBLER FASTENER HOLES CRACK AREA REPAIRSDR UIEA2022042700398Battery Pack · noneUPPER DECK L/H DOOR SQUIB PWR SUPPLY BATTERY INOP ( M7037 )(<P>U/D L/H DOOR SQUIB PWR SUPPLY BATTERY PACK REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 52-23-14 REV 104 - 15 MAR 2022</P>)SDR UIEA2022042200367None · none#3 NACELLE STRUT THRUST TANG - COVER PLATE CANNOT BE INSTALLED, DUE TO NO ACCESS ON THE UNDERNEATH AREA(<P>#3 NACELLE STRUT THRUST TANG - COVER PLATE FASTENER SUBSTITUTION IAW RI-54-00-15545 REV A</P>)SDR UIEA2022042200366None · none#2 NACELLE STRUT THRUST TANG - COVER PLATE CANNOT BE INSTALLED, DUE TO NO ACCESS ON THE UNDERNEATH AREA(<P>#2 NACELLE STRUT THRUST TANG - COVER PLATE FASTENER SUBSTITUTION IAW RI-54-00-15545 REV A</P>)SDR UIEA2022042200365None · none#1 NACELLE STRUT THRUST TANG - COVER PLATE CANNOT BE INSTALLED, DUE TO NO ACCESS ON THE UNDERNEATH AREA(<P>#1 NACELLE STRUT THRUST TANG - COVER PLATE FASTENER SUBSTITUTION IAW RI-54-00-15545 REV A</P>)SDR UIEA2022042200364Bushing · noneM/D STA 1000 RBL 11.33 FLOOR SUPPORT I/B CROSS BOLT HOLE FOUND ENLARGED(<P>M/D STA 1000 RBL 11.33" LUG FTG P/N : 366-53-15-A1364-102 REPLACED IAW SRM 51-10-02 AND P/N : 366-53-15-A1364-104 ATT BUSHING REPLACED IAW SOPM 20-50-03.</P>)SDR UIEA2022042200363Bushing · noneM/D STA 1000 LBL 11.33 FLOOR SUPPORT IB CROSS BOLT HOLE FOUND ENLARGED(<P>M/D STA 1000 LBL 11.33 LUB FTG P/N : 366-53-15-A13641-101 REPLACED IAW SRM 51-10-02 AND P/N : 366-53-15-A1364-103 ATT BUSHING REPLACED IAW SOPM 20-50-03.</P>)SDR UIEA2022042100361None · noneFX - AIRCON BAY WING CENTER SECTION LOWER SECTION LOWER SURFACE LH O/B CHORD CRACK AT STA 1231 LBL 104.(<P>FX - STA 1231 LBL 104" AIRCON BAY WING CENTER UPPER CHORD P/N : 65B10750-37 CRACK AREA REPAIRED IAW RI-57-00-15528 REV A</P>)SDR UIEA2022042100360None · noneFX - AIRCON BAY WING CENTER SECTION LOWER SECTION LOWER SURFACE RH O/B CHORD CRACK AT STA 1231 RBL 104.(<P>FX - STA 1231 RBL 104" AIRCON BAY WING CENTER UPPER CHORD P/N : 65B10750-38 CRACK AREA REPAIRED IAW RI-57-00-15529 REV A</P>)SDR UIEA2022042100359None · noneRHW ILES 1116 L/E NOSE BEAM LOWER CHORD FOUND CRACK(<P>RHW FIXED L/E NOSE BEAM ILES 1057 - ILES 1116 LOWER CHORD CRACK AREA REPAIRED IAW RI-57-41-15517 REV A</P>)SDR UIEA2022042100358None · noneRHW ILES 1116 L/E NOSE BEAM UPPER CHORD FOUND CRACK(<P>RHW FIXED L/E NOSE BEAM ILES 1057 - ILES 1116 UPPER CHORD CRACK AREA REPAIRED IAW RI-57-41-15517 REV A</P>)SDR UIEA2022042100357None · noneLHW ILES 1116 L/E NOSE BEAM LOWER CHORD FOUND CRACK.(<P>LHW FIXED L/E NOSE BEAM ILES 1057 - ILES 1116 LOWER CHORD CRACK AREA REPAIRED IAW RI-57-41-15518 REV A</P>)SDR UIEA2022042100356None · noneLHW ILES 116 L/E NOSE BEAM UPPER CHORD FOUND CRACK(<P>LHW FIXED L/E ILES 1057 - ILES 1116 NOSE BEAM UPPER CHORD CRACK AREA REPAIRED IAW RI-57-41-15518 REV A</P>)SDR UIEA2022042100355None · noneRHW L/E ILES 630 RIB ATT #5 STIFFENER FOUND CRACK(<P>RHW L/E ILES 630 RIB ATT #5 STIFFENER P/N : 65B15696-78 CRACK AREA REPAIRED AND INSTALLED IAW RI-57-00-15540 REV A</P>)SDR UIEA2022042100354None · noneLHW L/E ILES 630 RIB ATT #5 STIFFENER FOUND CRACK(<P>LHW L/E ILES 630 RIB ATT #5 STIFFENER P/N : 65B15696-78 CRACK AREA REPAIRED AND INSTALLED IAW RI-57-00-15539 REV A</P>)SDR UIEA2022042000352None · noneRHW #12 SPOILER LWR SURFACE SEVERAL AREA DISBOND(<P>PERFORMED PERMANENT METAL HOTBOND REPAIR AS PER SRM 51-70-10 REPAIR4 REV.114 ,FEB 20/2022</P>)SDR UIEA2022042000351None · noneLHW O/B AFTER FLAP O/B UPPER PANEL CHAFING(<P>PERFORMED PERMANENT METAL HOTBOND REPAIR AS PER SRM 51-70-10 REPAIR2 REV.114 ,FEB 20/2022</P>)SDR UIEA2022042000347None · noneRHW ILES 380 L/E LOWER FIXED PANEL SUPPORT BEAM FOUND CORROSION.(<P>RHW ILES 380 I/B L/E LOWER SURFACE PANEL INSTL SUPPORT BEAM CORROSION AREA REPAIRED IAW RI-57-41-15494 REV A.</P>)SDR UIEA2022042000346None · noneFX - APU TAIL CONE RH FRAME AND UPPER OF WL 310 FOUND CRACKED ( UPR OF PREVIOUS REPAIR AREA )(<P>APU COMP STA 2680.18 RH FRAME ON EXISTING REPAIR SEGMENT CRACK AREA REPAIRED IAW RI-53-80-15504 REV B</P>)SDR UIEA2022042000345None · noneU/D STA 680 - 700 STR 12R - STR 13R, FLOOR WEB ATTACHED STIFFENER FOUND HEAVY CORROSION.(<P>U/D STA 685 RBL 80 - RBL 95 WL 307.5 STIFFENER P/N : 65B06144-882 REPLACED AND INSTALLED IAW SRM 51-10-02 AND SRM 51-40-02.</P>)SDR UIEA2022042000344None · noneLH STA 2231 FRAME STR 25L 1EA HOLE FOUND CRACK.(<P>M/D STA 2231 STR 25L, 1EA FASTENER HOLE CRACK AREA OVERSIZE REPAIRED IAW RI-53-00-15534 REV B</P>)SDR UIEA2022042000343None · noneFX - APU TAIL CONE RH STA 2640 - 2680 RIVET FOUND LOOSE.(<P>APU COMPARTMENT STA 2670 - STA 2690 WL 305 - WL 315, ELONGATE FASTENER HOLE REPAIRED IAW RI-53-80-15497 REV B.</P>)SDR UIEA2022042000336None · noneLHW O/B FORE FLAP L/E 20" - 24"" FROM I/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022042000342None · noneNO.1 ENG R/H CORE COWL EXHAUST DUCT INLET EDGE AREA FOUND CHAFING ( P/N 224-2302-545 )(<P>NO.1 ENG R/H CORE COWL ( P/N : 224-2302-545 S/N : 325001 ) EXHAUST DUCT INLET EDGE CHAFING AREA WELD REPAIRED AND DOUBLER ( P/N : 224M4762-3 ) REPLACED IAW EO 1971A278-1SDR UIEA2022042000341None · noneSTA 2598 HINGE SUPPORT FRAME MOD AND STA 2598 LH LOWER LEFT CORNER MOD DOUBLER FASTENER S.E.M REPAIR.(<P>STA 2598 HINGE SUPPORT FRAME MOD AND STA 2598 LH LOWER LEFT CORNER MOD DOUBLER 1EA FASTENER S.E.M REPAIRED IAW RI-53-00-15537 REV A</P>)SDR UIEA2022042000340None · noneEMP - VERTICAL FIN L/H L/E FIXED PNL AT FS 245 AND FS 270 FAIRING 321D AREA RIVET FOUND LOOSE.(<P>EMP - VERTICAL FIN L/H L/E FIXED PNL AT FS 245 AND FS 270 AREAS LOOSE RIVET REPLACED IAW RI-55-00-15535 REV A</P>)SDR UIEA2022042000339None · noneLHW O/B FORE FLAP L/E 38" FROM I/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022042000338None · noneLH WING #1E L/E FLAP O/B LOWER FIXED PANEL FOUND BULGE UP.(<P>LHW L/E NOSE SKIN INSTL SKIN SPLICE STRAP AT OLES 1617.6 TO 1639.0 CORROSION AREA REPAIRED IAW RI-57-41-15493 REV A</P>)SDR UIEA2022042000337None · noneLH BS 800 FRAME AREA, 2EA CRACKS FOUND AT STA 14L. STRAP APPROX 1/8 INCH RUNNING FWD. 1/4 INCH RUNNING AFT.(<P>M/D STA 800 STR 14L. FRAME STRAP P/N : 65B26468-1, 1EA FASTENER HOLE CRACK AREA REPAIRED IAW RI-53-00-15527 REV A.</P>)SDR UIEA2022042000335None · noneLHW O/B FORE FLAP L/E 64" FROM I/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022042000334None · noneLHW O/B MID FLAP L/E 100" - 110"" FROM I/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022042000333None · noneLHW O/B MID FLAP L/E 120" - 125" FROM O/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022042000332None · noneRHW O/B FORE FLAP L/E 56-58" FROM O/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022042000331None · noneRHW O/B FORE FLAP L/E 15" FROM O/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022041900330None · noneRHW O/B FORE FLAP T/E 190" FROM O/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022041900329None · noneRHW O/B FORE FLAP T/E 70" - 72" FROM O/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022041900328None · noneRHW O/B FORE FLAP T/E 120 FROM O/B FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022041900327None · noneRHW O/B FORE FLAP FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022041900326None · noneRHW I/B MID FLAP L/E FOUND DELAMINATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5A REV.114 ,FEB 20/2022</P>)SDR UIEA2022041900325None · noneR/H O/B MID FLAP T/E (FROM O/B 7TH) SCREW HOLE FOUND ELONGATED(<P>PERFORMED PERMANENT COMPOSITE HOTBOND REPAIR AS PER SRM 51-70-07 PAR.5K REV.114 ,FEB 20/2022</P>)