N480HA
Service difficulty reports · 77
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N480HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N480HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HALA2009030800136Doubler · crackedOPEN - FUSELAGE, FS 1178 LT AND RT, DOUBLER AND SKIN, HAS A 2 INCH CRACK ON DOUBLER, AND A 2 INCH CRACK ON THE FUSELAGE SKIN PANEL AT CANTED STA 1178.225, LONGERON 3 LEFT AND 3 RIGHT. REPAIR IN WORK.SDR HALA0800532Module · malfunctionedAILERON STUCK 1/2 WAY LEFT OF CENTER IN FLIGHT. CKED FREEDOM OF MOVEMENT OF AILERON, NO DEFECT NOTED. FOUND AILERON TRIM IND OF CONFIG PG 1/2 LWD OF CENTER. ACCOMP FIM 27-10-00 TASK 801 MAINTENANCE MSG ON ATCL WAS NR 43 ACCOMP FIM 27-10-00 TASK 812. REPLACSDR HALA0800034Control Unit · failedANTI-SKID FAIL AFTER GEAR EXTENSION - ATB. TROUBLESHOT IAW FIM 32-45, TASK 807. REMOVED AND REPLACED DCU IAW AMM 31-43-02. OPS CHECK GOOD. MIC SHEET CLEARED. PLACARD REMOVED.SDR HALA0800033Control Unit · failedANTI-SKID FAIL IN FLT - ATB. REPLACED BCU PER AMM 32-45-01. RETURN TO SERVICE TEST PASSED.SDR HALA0700495Pump · malfunctionedAIRBORNE - RT HYD QTY LOW LIGHT, WILL BE LANDING ON 8R. WILL DO AN ALT GEAR EXTENSION AND WAIT FOR MAINT AND LINE SERVICE OUT THERE. CREW DECLARED AN EMERGENCY. LANDED AT HNL, WHERE AN UNEVENTFULL LANDING WAS MADE. T/S RT HYD SYSTEM. REMOVED AND REPLACED SDR HALA0700334None · noneATB AFTER ROTATION AND DURING CLIMB-OUT TOWER REPORTED VAPOR TRAILING FROM LEFT SIDE OF AIRCRAFT. RETURNED FOR NORMAL LANDING. DE-BRIEFED CREW AND THEY REPORTED NO ENG ABNORMALITIES. PERFORMED ENG EXCEED BITE PER FIM 71-00 TASK 801, NO EXCEEDANCE NOTED. PESDR HALA0700323Connector · dirtyATB - AFTER TAKEOFF, LOST NR 1DU NR 6 DU STARTED TO FAIL NR 4 CU FAILED FOR A FEW MINUTES. REMOVED AND CLEANED CONNECTORS OF DU'S 1, 4 AND 6. GND OPS CHK OK 31-43-01.SDR HALA0700291Accumulator · rupturedRT HYDRAULIC SYSTEM ACCUMULATOR RUPTURED. REPLACED RT HYDRAULIC SYSTEM ACCUMULATOR PER AMM 29-12-05. LEAK CK CK.SDR HALA0700205Unknown · unknownBTB: ENG L SYS FAIL LIGHT CAME ON DURING START. INTERMITTANT FAULT START CIRCUIT (FUEL SW CIRCUIT) ERASED FAULT. PERFORMED EEC 1 RTS TEST PASSED.SDR HALA0700171Pump · fluctuatesLT HYDRAULIC PUMP FAIL. PRESSURE FLUCTUATED BETWEEN 3000 PSI AND ZERO AT FLIGHT IDLE. TURNED LT ENG DRIVEN PUMP OFF AND TURNED ON TRANSFER PUMP, PRESSURE AND QTY NORMAL.//R/R LEFT ENG HYD PUMP PER M/M 29-11-01 GRD RUN GOOD CHECKED PLUG P1-3355 PIN A TO PLUG SDR HALA0700172Pump · failedBTB - HYD L PUMP FAIL LT ON. REMOVED AND REPLACED LT HYD ENG, DRIVEN PUMP PER AMM 29-11-01. OPS CHECK OK, LEAK CHECK OK. SECURITY CHECK OK.SDR HALA0700040Bleed Valve · malfunctionedBTB - NO AIR ON APU ON START. PERFORMED APU RTS TEST FAILED BLEED CONTROL VALVE OPEN CIRCUIT FAULT. PERFORMED FIM 49-50-00-810-804 REF WDM 49-30-004. PERFORMED REPAIR CONFIRMATION RTS PASSED.SDR HALA0700031Wire · damagedFLT CREW REPORTS, STALL WARNING FAULT LEVEL ONE ALERT ANNUNCIATED, NO TAKEOFF. FOUND WIRES TO FO STICK SHAKER N/G. REPAIRED WIRES PER SWPM 20-10-03. RTS FOR STALL WARNING SYSTEM CHECK OK.SDR HALA0700008Apu · explodedON PARKING AT KOA PILOTS SMELLED FAINT SMOKE THEN NOTICED VISIBLE SMOKE COMING OUT OF A/C VENTS. SECURED BOTH PACKS, EXPEDITED DEPLANING OF PAX THEN APU BLEW UP. NO FIRE INDICATION ON PANEL, DISCHARGED BOTH BOTTLES. REMOVED AND REPLACED NR 2 FIRE BOTTLE PERSDR HALA0600920Warning System · malfunctionedBTB - NR 2 T/R FAULT LIGHT ILLUMNATED. ACCOMPLISHED FIM 78-34 AND TASK 806 AND TASK 78-30-0, 0-702-801. NO FAULTS NOTED. OK FOR SERVICE.SDR HALA0600866Pivot · looseBTB - AFTER ENG START UNABLE TO TURN STEERING TO RT. STEERING WAS JAMMED ONLY TO RT SIDE. AFTER INSPECTION BY MAINT JAM WAS NOT REMAINING AND WERE ABLE TO RETURN TO GATE. FOUND NLG STEERING BYPASS LEVER PIVOT BOLT LOOSE. RESECURED AND RESAFETIED BOLT. CHECKEDSDR HALA0600805Warning Message · false activationBTB - "AIR SYSTEM R PRESS LO" ALERT AFTER ENG START. PERORMED FIM 36-10-00-310-505 PSC BITE CHECK NO FAULTS NOTED. OPS CK GOOD.SDR HALA0600803Bleed Valve · failedBTB: APU VALVE DISAGREE LEVEL 1 ALERT CAME ON AFTER SHUTTING DOWN APU ON TAXI OUT. REPLACED APU BLEED AIR VALVE PER AMM 36-16-02.SDR HALA0600632Skin · scratchedBAGGAGE SERVICE FOUND DENT & SCRATCH ALONG RT SIDE OF FUSELAGE APPROX L 19R FROM STA 253-357. BLENDED DENT AND SCRATCH AREA PER SRM 51-10-4, PERFORMED EDDY CURRENT INSP DENT AREA. NO CRACKS NOTED. DAMAGE FOUND TO BE CONDITION 3 PER SRM 53-00-01, PERMANENT RSDR HALA0600561Igniter · unknownBTB - RT ENG DOES NOT LIGHT OFF IN AUTO. REMOVED AND REPLACED RT ENG B IGNITOR PLUG IAW AMM 74-20-04. OPS CHECK GOOD. OK FOR SERVICE.SDR HALA0600389Compressor Wheel · damagedDUE TO TREND ENGINE TO BE BORESCOPED. FOUND NR 3 HIGH PRESSURE COMPRESSOR PLATFORM DAMAGE AND DAMAGE NR 4 STAGE BLADES. ENGINE TO BE REPLACED.SDR HALA0500169Pump · failedDURING EO 29-02-02-11 REV A, FOUND AUX PUMP ELECTRICAL CONNECTOR ON PUMP MELTED, NEED TO REPLACE PUMP. AIRCRAFT SIDE PLUG DISCONNECTED FROM PUMP. REMOVED AND REPLACED AUX HYD PUMP IAW AMM 29-21-01, OPS AND LEAK CHECK GOOD. (M)SDR HALA0300230Control Unit · malfunctionedRIGHT ENIGNE SYSTEM FAIL LIGHT CAME ON. PERFORMED WIRING CHECK PER FIM 73-21. ALL OK. REMOVED AND REPLACED NR 2 INDEPENDANT OVERSPEED PROTECTOR (IOP) PER MM 73-21-11. CHECK OK. RTS CHECKED OK. OK FOR SERVICE. (M)SDR HALA0200702Generator · failedFLT 541 - HNL - NUMEROUS POEWR INTERUPTIONS ON DESCENT TO HNL. NO BREAK POWER TRANSFER APPEAR INOPERATIVE. EMERGENCY LIGHTS ON (5 TIMES). INTERMITTENT ANNUNCIATOR LIGHTS, DCU FAIL. NR 1 ENGINE VIBE HIGH, INDICATED 5.0 PLU (AMBER) FOR NR 1 N1 ON ONE OCCASSISDR HALA0200139Gearbox · failedFLT 180 - HNL - FOUND RIGHT ENGINE FAIL LIGHT CAME ON IN FLIGHT. REMOVED NR 2 ENGINE GEARBOX, ACCESSORY PER MM 72-61-00. INSTALLED GEARBOX PER MM 72-61-00 PARA E2P. LEAK AND OPS CHECK GOOD, PER TEST 5 TASK 71-0014-710-802. (M)SDR HALA0200102Duct · crackedCRACK ON APU INLET DOOR DUCT. REPAIRED PER HAL M105 FILE.SDR HALA0100168Pump · malfunctionedHNL - FLT 520 - RIGHT HYDRAULIC TEMPERATURE HIGH LIGHT ON. REMOVED AND REPLACED AUX PUMP OPS CHECK, LEAK CHECK OK, PER MM 29-21-01. (M)
Back to N480HA