N482MC
Service difficulty reports · 39
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N482MC' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N482MC' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2026092800918Battery · inoperativeFOUND EMERGENCY FLASHLIGHT BATTERY DEAD AT FLIGHT ATTENDANT SEAT AT L1 DOOR FWD OUTBOARD FLASHLIGHT.(<P>REMOVED DEAD FLASHLIGHT FROM FLIGHT ATTENDANT SEAT AT L1 DOOR FWD OUTBOARD POSITION AND REPLACED WITH NEW FLASHLIGHT, PN P2-07-0001-2015. SECURED WITH 2 SCRSDR UIEA2026040700149Web · crackedCRACKED WEB OF MAIN CABIN FLOORBEAM AT BS 2020, NEAR LBL 108. REPAIR DAMAGED ARE IAW EI T2026A53M-517 REV 2. JOB COMPLETED AND CONDITION CHECK NORMAL.SDR UIEA2026040700150Door Sill · crackedCRACK FOUND R1 DOOR UPPER SILL AFT TEE CRACK, BS 480, S-16R, WL 280. REMOVE THE DAMAGE TEE IAW SRM 51-40-02-0G-0 REV 126. FABRICATED PART IAW EI T2026A53M-564 REV 1. INSTALL FABRICATED PART IAW SRM 57-40-02-0G-0 REV 126 AND DWG 65B08301 SHEET 7 REV B.SDR UIEA2026040800171Tension Tie · not reportedDEVIATIONS FOUND DURING PERFORM SB 747-53A2559. ACCOMPLISH EI T2026A53M-477 REV 5. JOB COMPLETED AND CONDITION CHECK NORMAL.SDR UIEA2026040800172Beam · corrodedFOUND LAVATORY THRESHOLD BEAM CORROSION LOC=CC1. REPAIRED LAVATORY THRESHOLD BEAM AND DOORWAY BEAM LOC=CC1 IAW CMM 25-42-88 REV 13 & EI T2026A25M-446 REV 0. 2. REFERENCE JOB CARD ATTACHING SHEET = 0507577 AND 0507578. 3. CONDITION CHECK NORMAL.SDR UIEA2026040800173Beam · corrodedFND LAVATORY THRESHOLD BEAM CORROSION LOC=DC1. REPAIRED LAVATORY THRESHOLD BEAM AND DOORWAY BEAM LOC=DC1 IAW CMM 25-42-88 REV 13 & EI T2026A25M-446 REV 0. 2. REFERENCE JOB CARD ATTACHING SHEET = 0507579 AND 0507580. 3. CONDITION CHECK NORMAL.SDR UIEA2026040800174Light · no testFOUND CREW REST EMERGENCY LIGHT (M8533) FUNCTION FAIL. REPLACED CREW REST EMERGENCY LIGHT (M8533) IAW AIPC 33-29-10-40B REV 91 AND WDM 33-51-64 REV 73. PERFORMED EMERGENCY LIGHT OPERATIONAL TEST IAW AMM 33-51-00-715-001 REV 116. THE RESULT WAS SATISFACTORY.SDR UIEA2026040800175Power Strip · no testFOUND L DR5 OVRD EMERGENCY LIGHT (M7923) FUNCTION FAIL. REPLACED L DR5 OVRD EMERGENCY LIGHT (M7923) POWER SUPPLY IAW AMM 33-51-04-002-009-001 & AMM 33-51-04-402-012-001. PERFORMED POWER SUPPLY INSTALLATION TEST IAW AMM 33-51-04-402-012-001. THE RESULT WAS SSDR UIEA2026040800176Battery · no testFOUND L4 DOOR OVRD EMERGENCY LIGHT (M7921) FUNCTION FAIL. REPLACED L DR4 OVRD EMERGENCY LIGHT (M7921) POWER SUPPLY BATTERY IAW AMM 33-51-04-902-001-001 REV 116. 2. PERFORMED POWER SUPPLY BATTERY INSTALLATION TEST IAW AMM 33-51-04-902-001-001 REV 116. THE RESSDR UIEA2026040800177Power Supply · no testFOUND U/D EMERGENCY LIGHT (M5932) FUNCTION FAIL. REPLACED U/D EMERGENCY LIGHT (M5932) POWER SUPPLY IAW AMM 33-51-04-002-009-001 & AMM 33-51-04-402-012-001 REV 116. PERFORMED POWER SUPPLY INSTALLATION TEST IAW AMM 33-51-04-402-012-001 REV 116. THE RESULT WASSDR UIEA2026040800178Power Supply · inoperativeFOUND ZONE B EMERGENCY LIGHT (M6879) FUNCTION FAIL.. REPLACED ZONE B EMERGENCY LIGHT (M6879) POWER SUPPLY IAW AMM 33-51-04-002-009-001 & AMM 33-51-04-402-012-001 REV 116. PERFORMED POWER SUPPLY INSTALLATION TEST IAW AMM 33-51-04-402-012-001 REV 116. THE RESUSDR UIEA2026040800179Light · inoperativeFOUND LT OVERWING EMERGENCY LIGHT (L1699) INOP AT FWD SIDE. REPLACED LT OVERWING EMERGENCY LIGHT ASSY (L1699) IAW AMM 33-51-03-004-034 & AMM 33-51-03-404-007 REV 116. PERFORMED EMERGENCY LIGHT ASSY INSTALLATION TEST IAW AMM 33-51-03-404-007 REV 116. THE RESSDR 2025FA0000582Shaft · mismanufacturedMAINTENANCE AND REPAIR PROBLEM : REPAIR DONE WITHOUT APPROVED DATAS BY A MRO, THE SHAFT DESIGN AT ONE END IS MISSING TWO HOLES FOR THE OÏL ENGINE LUBRIFICATION. THE APU HAS BEEN ANNOUNCED WITH OÏL LEAKAGE AFTER 270 HOURS OF SERVICES SINCE LAST OVERHAUL.SDR UIEA2025071100911Lamp · inoperativeUPPER DECK TOP OF STAIRWELL EMERGENCY CEILING LIGHT INOPERATIVE. RELAMPED UPPER DECK EMERGENCY CEILING LIGHT AT THE TOP OF STAIRWELL IAW AMM 33-51-07-962-001. OPS CHK OK.SDR UIEA2025071100912Lamp · inoperativeL2 DOOR JAMB FWD ROOR LIGHT INOP. RELAMPED DOOR JAMB FWD DOOR LIGHT IAW AMM 33-51-05-962-031. OPS CHK OK.SDR UIEA2025071100913Lamp · inoperativeBOTH L5 DOOR JAMB EMERGENCY LIGHTS INOP. RELAMPED BOTH L5 DOOR JAMB EMERGENCY LIGHTS IAW AMM 33-51-05-962-031. OPS CHK OK. NO FURTHER DEFECTS NOTED.SDR UIEA2025071500955Battery Pack · inoperativeUPPER DECK LT GULL DOOR INSIDE LEVER EMER LIGHT INOPERATIVE. RELAMPED LH GULL DOOR EMERGENCY LIGHTS AND REMOVED AND REPLACED BATTERY PACK M5057 IAW AMM 33-51-06-962-009. OPS CHK OK. NO FURTHER DEFECTS NOTED.SDR UIEA2025071500956Battery Pack · inoperativeFWD AND MID LT EXTERIOR OVER WING EMERGENCY LIGHTS INOP. REMOVED AND REPLACED LH EMERGENCY LIGHT POWER SUPPLY IAW 33-51-04-902-001-001. OPS CHK OK. NO FURTHER DEFECTS NOTED.SDR UIEA2025071500957Battery Pack · inoperativeRH EXTERIOR OVER WING AFT EMERGENCY LIGHT INOP. REMOVED AND REPLACED RH EMERGENCY LIGHT POWER SUPPLY IAW AMM 33-51-04-902-001-001. OPS CHK OK. NO FURTHER DEFECTS NOTED.SDR UIEA2025071500958Light · inoperativeCREW REST EMERGENCY LIGHTS AT THE CEILING INOP. REMOVED AND REPLACED CREW REST EMERGENCY LIGHT AT THE CEILING IAW AMM 33-51-07-402-015. OPS CHK OK. NO FURTHER DEFECTS NOTED.SDR UIEA2025042200560Door · damagedPACK 1 & PACK 3 ACCESS DOORS DAMAGED IN FLIGHT.(<P>ACCESS DOORS REMOVAL & REPLACEMENT IN WORK, DAMAGED BELLY FAIRNINGS WITHIN ALLOWABLE LIMITATIONS FOR TEMP REPAIR TO BE CORRECTED AT NEXT C-CHECK PER SRM 51-70-02-1A-0 & 53-40-70-1A-1. REF TASK 52-48-01-004-001SDR UIEA2025021300133Engine · sparksPASSENGERS & FLIGHT ATTENDANT SAW SPARKS COMING FROM THE FAN BLADES ON ENG 03 & 04(<P>INSPECTED FAN BLADES ABRADE SHROUD ENG INLET AND EXH BLADES ON ENG 3 AND 4 IAW 747 FIM 71-00 FT 104 SHT 1, NO DEFECTS FOUND AND FLIGHT CREW REPORTED NO ANOMOLIES. A/C OK FOR SDR UIEA2024120201141Skin · noneUPGRADE - TIME - LIMITED REPAIR DOUBLER ON FWD LOWER CORNER OF AFT CARGO DOOR OUTER SURFACE.(<P>1.RMV DOUBLER I.A.W SRM 51-40-02-0G-0, REV.122. 2.ACCOMPLLSH I.A.W EL NO.T2024A52M-2787,REV.0 (SRM 52-30-01-2R-2, REPALR 2, REV.122). 3.JOB COMPLETED AND COND CHK NSDR UIEA2024120201142Motor · failedFOUND R/H W/W OUTBD FLAP ALTERNATE DRIVE MOTOR FUNCTION FAIL.(<P>1. IAW AMM 27-51-17-004-026 REV. 111 AND AMM 27-51-17-404-010 REV. 112. 2. REPLACE R/H W/W OUTBD FLAP ALTERNATE DRIVE MOTOR. OPS CHK OK</P> / <P> </P>)SDR UIEA2024120201143Motor · intermittentFOUND L/H W/W INBD FLAP ALTERNATE MOTOR INTERMITTENT.(<P>1. IAM AMM 27-51-17-004-001 REV 112 AND 27-51-17-404-027 REV 112. 2. REPLACED L/H W/W INBD FLAP ALTERNATE MOTOR. OPS CHK OK</P>)SDR UIEA2024120201144Voice Recorder · inoperativeFAULT - FOUND COCKPIT AREA MIC NO FUNCTION.(<P>1. IAW WDM 23-71-11 REV. 68 SSM 23-71-01 REV 68 CHECK WIRE CONTINUITY RESULT NORMAL. 2. IAW AMM 23-71-04, 23-71-02, 23-71-01 REV 112 REPLACED CVR, CVR CONTROL PANEL & AREA MIC. 3. IAW AMM 23-71-04, 23-71-02, 23-71SDR UIEA2024120201145Light · inoperativeFOUND R/H OVER WING EMERGENCY LIGHT INOP, COUNT NO. 1 FROM FWD, POWER SUPPLY M7919.(<P>1. IAW AMM 33-51-03-004-034, 33-51-03-404-007 REV 112 REPLACED R/H OVER WING EMERGENCY LIGHT ASSY. 2. IAW AMM 33-51-03-404-007 REV 112 PFM LAMP TEST OF R/H OVER WING EMERGENSDR UIEA2024120201146Charger · no testFOUND L3 DOOR EMERGENCY LIGHT CHARGER (M7919) FUNCTION FAIL.(<P>1. IAW AMM 33-51-04-002-009-001 & 33-51-04-402-012-001 REV 112 REPLACED EMERGENCY LIGHT CHARGER AND PERFORMED POWER SUPPLY TEST. THE RESULT WAS SATISFACTORY.</P>)SDR UIEA2024120201147Power Supply · no testFOUND THE EMERGENCY LIGHT BATTERY FUNCTION FAIL (M5933, M7924).(<P>IAW AMM 33-51-04-002-009-001 & 33-51-04-402-012-001 REV 112 REPLACED EMERGENCY LIGHT POWER SUPPLY (M5933, M7924) AND PFM TEST OF POWER SUPPLY, RESULT WAS SATISFACTORY.</P>)SDR UIEA2024120201148Light · inoperativeFOUND DOOR SLIDE EMERGENCY LIGHT INOP, EQUIP NO: X31 8, X320, X322, X321, X323, X324.(<P>IAW AMM 33-51-06-000-801, 33-51-06-400-801, 33-51-06-004-046 & 33-51-06-404-049 REV 112 REPLACED BATTERY AND LIGHT ASSY AND PERFORMED LIGHT TEST. THE RESULT WAS SATISFACTOSDR UIEA2024120201149Light · failedFOUND L/H OVER WING EMERGENCY LIGHT FAIL, NO.3 COUNT FROM FWD.(<P>IAW AMM 33-51-03-004-034 & AMM 33-51-03-404-007 REV 112 REPLACED THE L/H OVER WING LIGHT ASSY (L01871) AND PERFORMED NEW OVERWING LIGHT INSTALLATION TEST, RESULT WAS SATISFACTORY.</P>)SDR UIEA2024120201150Battery · no testFOUND THE EMERGENCY LIGHT GOES OFF WITHIN 15 MINUTES. (M5057, M7921, M7920).(<P>1. IAW AMM 33-51-04-902-001-001 REV 111 REMOVED EMERGENCY LIGHT BATTERY 3 EA. 2. IAW AMM 33-51-04-902-001-001 REV 112 INSTALLED & TEST THE EMERGENCY LIGHT, RESULT WAS SATISFACTORY.SDR UIEA2024120201151Light · inoperativeFOUND CREW REST EMERGENCY LIGHT INOP EQUIP NO. M8533(<P>IAW AMM 33-51-04-002-009-001 & 33-51-04-402-012-001 REV 112 REPLACED M8533 EMERGENCY LIGHT ASSY AND PERFORMED POWER SUPPLY TEST. TEST PASSED.</P>)SDR UIEA2024120201152Power Supply · failedFOUND EMERGENCY LIGHT POWER PACK M14168 FAIL.(<P>IAW AMM 33-51-04-002-009-001, 33-51-04-402-012-001 REV 112 REPLACED POWER PACK (M14168) AND PERFORMED TEST. THE RESULT WAS STISFACTORY.</P>)SDR UIEA2024060600498Computer · malfunctionedTCAS OFF MSG AFTER T/O/. ATC REPORTS THEY ARE UNABLE TO RECEIVE OUR MODE "A" OR "C" INFORMATION.(<P>REPLACED TCAS COMPUTER PER AMM 34-45-01. OPS CHECK NML. LH AND RH ATC GRD TEST PER AMM 34-52-00, OPS CK NML.</P>)SDR UIEA2024031500150Access Door · missingDURING POST FLIGHT WALK AROUND INSPECTION, DISCOVERED #1 AIR CONDITIONING PACK 1 ACCESS DOOR MISSING.(<P>REPLACED MISSING ACCESS DOOR #1 AIR CONDITIONING PACK AND PERFORMED ADDITIONAL ASSOCIATED REPAIRS PER AMM 52-51-01. NO FURTHER DEFECTS NOTED. </P>)SDR UIEA2023080800774Unknown · unknownTCAS INOP(<P>PERFORMED TCAS OPS CHECK. OPC CHECK GOOD. PERFORMED TCAS GROUND TEST, TEST PASSED. PERFORMED LRU ATC LT & RT TEST, TEST GOOS IAW B747 AMM 34-45-00. TCAS SYS OPS NORMAL.</P>)SDR UIEA2023070600726Fmc · unknownL/H FMC OUTPUT LOST(<P>REMOVED AND REPLACED L/H FMC IAW AMM 34-61-00. INSTALLED ALL NEW SOFTWARE IAW AMM 34-61-00, OPS TEST IAW AMM 34-61-00. PERFORMED AUTOLAND UNIQUE TEST IAW 22-10-00. NO KNOWN DEFECTS AT THIS TIME. </P>)SDR UIEA2023061400639Computer · unknownAT 2000 FT AFTER TAKEOFF, EICAS MSG "TCAS OFF" WHILE TRANSPONDER PROPERLY SET. ATC REPORTED BEING UNABLE TO SEE US ON THE RADAR. ALL CIRCUIT BREAKERS IN AND NO OTHER EICAS MESSAGES.(<P>REMOVED AND REPLACED TCAS COMPUTER PER TASK 34-45-00. TCAS GROUND TEST PASS