N483UA
Service difficulty reports · 92
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N483UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N483UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013120393407Skin · dentedDENT IN LT SIDE FUSELAGE ALONG CIRCUMFERENTIAL JUST FWD OF WATER SERVICE PANEL AT EYE LEVEL. DENT LOCATED AT FRAME 28L & JUST BELOW STRINGER 34L. DENT IS SMOOTH NO CREASES, APPROXIMATELY 3 IN X 4 IN & .007 DEEP. PERFORMED EXT DVI, NO CRACKS NOTED. DENT IS SDR CALA2013110892740Controller · faultyBUILDING HISTORY OF "HOT AIR FAULT" ECAM WARNINGS. RECENT LEG FAULTED "NO ZONE CTL DATA" AT FLT PHASE 4. REPLACE ZONE CONTROLLER, PCN 565-9207, IAW AMM 21-63-34.SDR CALA2013102392297Cowling · out of adjustNR 1 ENG COWL IS NOT FLUSH JUST AHEAD OF FWD COWL LATCH UNDERSIDE. ADJUSTED COWL & FOUND COWL WITHIN LIMITS.SDR CALA2013100291652Servo Valve · faultyELEV SERVO FAULT DISPLAYED, REPEAT. CFDS FAULTING LT G ELEV SERVO VALVE 34CE1. REPLACED LT ELEV SERVO CONTROL VALVE IAW AMMS 27-34-51-000-008-A & 27-34-51-400-003-A. OPERATIONS CHECKED NORMAL ALL MODES NO MESSAGES.SDR CALA2013100191614Servo · faultyELEVATOR SERVO FAULT DISPLAYED ON UPPER ECAM SCREEN, - F -CTL. GOT ECAM DURING FLT CONT CHECK. FLT ATTENDANT REPORTED LOUD CLUNK FROM TAIL COINCIDENTAL W-ECAM PROG TEXT: - ITEM ROLLED FORWARD. REPLACED LT OTBD BLUE ELEVATOR SERVO IAW MM, OPERATIONS CHECKEDSDR CALA2013093091578Computer · faultyF-CTL ELEV SERVO FAULT. REPLACED NR 2 ELAC IAW MM 27-93-00-710-001-A & TESTED OK. ACCOMPLISHED CAT 3 AUTOLAND TEST IAW MM 22-97-00, CHECKED OKAY.SDR CALA2013092091299Bolt · shearedCUSHION SEAL ONE EACH BOLT SHEARED, RT WING, OTBD FLAP IAW MT-57-008 IPC 57-53-21-05 ITEM 150, SRM 57-53-00 FIG 220 0R 224, IAW CDL 27L REPLACED NEW SCREWSDR CALA2013092091298Bolt · shearedCUSHION SEAL ONE EACH BOLT SHEARED, LT WING OTBD FLAP IAW MT-57-008 IPC57-53-21-05 ITEM 150, SRM57-53-00 FIG 220 OR 224, REPLACED NEW SCREW.SDR CALA2013090691067Display · failedCAPTAINS LT SCREEN IS BLANK. SWAPPED CAPTAIN`S DISPLAY UNIT WITH LOWER ECAM DISPLAY UNIT. CW DDP. ** DL1621 CREATED TO MONITOR. REPLACED LOWER ECAM DISPLAY UNIT, CHECKED GOOD.SDR CALA2013090590998O-Ring · damagedECAM CAUTION MESSAGE, Y RSVR LO LVL MESSAGE INOPERATIVE, HYDRAULIC. FOUND HYDRAULIC LEAK FROM AUTO BRAKE SELECTOR VALVE CENTER B-UNION PIPE. REPLACED O-RING, SERVICED HYDRAULIC TO FULL. LEAK & OPERATIONS CHECKED OK. ECAM MESSAGE CLEARED.SDR UALA2013072405204Packing · wornDURING PREFLIGHT, FOUND FUEL DRIP FROM BOTTOM NR 2 NACELLE. FOUND PACKINGS AND HOUSING WORN. R & R IAW AMM 24-21-42-400- 010B13 AND AMM 73-12-41-400-010-B13. RAN ENGINE FOR THREE MINUTES AND OPS AND LEAKS CHECKED GOOD.SDR UALA2013061704156Seat · unsecureSEATS AT ROW 37 ABC, LOOSE. SECURED SEATS AT ROW 37 ABC OK TO CONTINUE.SDR UALA2013060503894Cover · missingLEFT MLG MISSING PLASTIC COVER WHERE L-G MEETS AC. REPLACED RUBBER CUP. OK TO CONTINUE.SDR UALA2013051403351Battery · no testEMERGENCY LIGHT SYS AFT FAILED TEST. REPLACED BATTERY IAW AMM, OPS CHECKED OK.SDR UALA2013032501854Seat · faultyFIRST OFFICER SEAT MANUAL UNLATCH STICKS AND BINDS. REPLACED FIRST OFFICER SEAT, OPS GOOD.SDR UALA2012121907297Seal · missingCABIN FIRE EXTINGISHER MISSING SEAL. REPLACED FIRE EXTINGISHER.SDR UALA2012100805690Unknown · malfunctionedCABIN EMERGENCY LIGHTING CHECK FAIL. REF A320 3SV STEP 2. CYCLED AND RESET CIDS POWER. CABIN EMERGENCY LIGHT TEST OKAY.SDR UALA2012100205568Controller · malfunctionedFUEL IMBALANCE OF 1200 LBS. REPLACED FQIC PER MM 28-42-34-400-001-A OPS CHECKED GOOD PER 28-46-00-740-001-ASDR UALA2012051002689Power Supply · no testWHEN TESTING EMERGENCY LIGHTING AFT LT BAT FAULTED. REPLACED POWER SUPPLY AND BATTERY PACK.SDR UALA2012012600535Rudder · faultyDURING VACUUM LOSS INSPECTION (DONE BY AIRBUS) IT WAS NOT POSSIBLE TO APPLY VACUUM TO ONE OF THE INSP HOLES. CHECKS ACP ON PTT SEQUENCE 7962015. REF CF9015 REMOVED RUDDER. NEED TO INSTALL NEW RUDDER. INSTALLED HINGE BOLTS ONLY. BOLTS NOT TORQUED. ACP'D SDR UALA2011012400401Wire · damagedFOUND BURNED & BROKEN WIRES 2825-5805 & 2825-5813 IN RT MAIN WHEEL WELL. REPLACED WIRE W2825-5805-20 FROM 10QU-A TO 6793VN. TERMINATED & SECURED WIRE W2825-5813-22 FROM 10QU-A UP TO PRESSURE SEAL 7502VP IN RT WW CEILING REF WD28-25-04 AND HOOK-UP LIST PG 141SDR UALA2010070902454Circuit Board · failedEMERGENCY EXIT LIGHT BULB ON UPPER CONSOLE BURNED OUT. "OFF" LIGHTS WORK DURING LAMP TEST, BUT DO NOT ILLUMINATE WHEN SWITCH IS PLACED "OFF". CHECKED FUSE "F" FOR OPEN CIRCUIT. FOUND BOARD 7LP CAUSING ISSUE. LIGHT WORKS OFF PIN 44 REF ASM. FOUND THAT BOARSDR UALA2010052601807Electrical Box · failedSTEERING INOP WHEN ACFT GOT TO GATE. CYCLED ANTI-SKID NOSE WHEEL STEERING SWITCH SEVERAL TIMES AND STEERING CONTROL RETURNED. REPLACED NOSE WHEEL STEERING ELECTICAL BOX. NO FURTHER ISSUES.SDR UALA2010040501120Unknown · odorCREW REPORTS A POSSIBLE RUBBER BURNING ODOR OR ELECTRICAL BURNING ODOR IN THE VICINITY OF ROW 24ABC. A NON-REV CREWMAN CHECKED IT OUT AND FOUND THE SMELL HAD DISSIPATED. NO FURTHER PROBLEMS FOUND. SAMC ADVISES THAT UPON ARRIVAL CHECK THE CABIN EMERGENCY EXIT SDR UALA2010021500561Power Supply · no testFOUND EPSU BATTERY EMERGENCY R DISPLAYED ON EMERGENCY LIGHT CHECK. FOUND POWER SUPPLY IN FWD CABIN NOT TESTING CORRECTLY. REPLACED IAW MM. ALSO REPLACED BATTERY. OPS CHECKED NORMAL.SDR UALA2010020200415Light · faultyFWD ENTRY AREA LIGHTS FLICKER AND CHANGE SETTINGS BY THEMSELVES ACCOMPANIED BY SLIGHT BURNING ODOR AS REPORTED BY F/A. OPENED FWD ENTRY AND FWD GALLEY CEILING PANELS, INSPECTED WIRES AND BALLASTS: NO EVIDENCE OF ARCING OR WHERE SMOKE ODOR ORIGINATED. PULLED- SDR UALA2010020800479Connector · out of toleranceRED EMERGENCY ESCAPE LIGHT INOP AT SEAT 12C MORE TIME NEEDED TO TROUBLESHOOT. RELAMP NO HELP. ALL OTHER ESCAPE LIGHTS OPERATE NORMAL IN COMPLIANCE WITH MEL 3350C. FOUND WIRES PULLED OUT OF CONNECTOR AT SEAT LIGHT, REPLACED CONNECTOR AND SECURED, OPS CK OF ESDR UALA2009102203292Power Supply · faultyEMERGENCY EXIT LIGHTS TEST FAILS EPSU AFT L INTERNAL FAULT. FOUND SHORT UNDER 2ND FROM LAST SEAT ABC, ACCOMPLISHED ENVIRONMENTAL SPLICE, USED POWER SUPPLY FROM ABOVE DOOR 1L TO OP CK. ACCESS PANEL ABOVE 1L REMOVED AND STOWED BEHIND PONY WALL AT 1AB, BAD POWESDR UALA2009080602390Indicator · shortedWHEN THE RAMP PRESSED THE LIGHT TEST BUTTON ON THE 108VU, SMOKE STARTED POURING OUT OF THE BACK OF THE PANEL. FOUND ADIRU AND AVNCS VENT LIGHT BODY SHORTED. NEEDS 25HQ BODY AND CAP ASSY TO FIX. NEEDS 25HQ INDICATOR LIGHT BODY AND INDICATOR CAP ASSY TO FIX. SDR UALA2009022300623Bottle · low pressureDOOR 2L SLIDE BOTTLE PRESSURE LOW. SERVICED BOTTLE.SDR UALA2009020200344Epsu · faultyCIDS SYS TEST FAILED DUE TO DOOR 1L SLIDE REPLACEMENT AND RE-INSTALLATION. BATTERY FAULT ON EPSU AT DOOR 1L. REPLACED BATTERY, NO HELP. SWAPPED EPSU FROM CENTER RIGHT AND PROBLEM FOLLOWED. SUSPECT BAD PART FROM STOCK. REPLACED EPSU BACK AT CENTER RIGHT. SDR UALA2009010500060Smoke Detector · damagedAFT PIT SMOKE DETECTOR DAMAGED. R&R FWD DETECTOR.SDR 2008UALA05521Smoke Detector · inoperativeLAV SMOKE DETECTOR INOP. REPLACED LAV 'D' SMOKE DETECTOR. AC OK FOR SERVICE.SDR 2007UALA05098Girt Bar · dirtyDOORS 2L & 2R FAILED ARMING SLIDE FORCE TESTS. DIRTY/UNLUBED GIRT FITTING INTERFERENCE. CLEANED AND LUBED GIRT BAR FITTING AND BAR. OPS CHECKED NORMALLY.SDR 2007UALA04305Blade · failedCREW COMMENTS: HEARD A BANG, GOT ECAM ENG 2 STALL. NO ABNORMAL ENG INDICATIONS, ENG RUNNING NORMAL SINCE. 11-01-07 FOUND NR 2 ENGINE STALL DUE TO DAMAGED HPC STAGE 6 BLADE- FOUND TORN AND BEYOND DAMAGE TOLERANCES. REPLACED NR 2 ENGINE DUE TO DAMGE OF HSDR 2007UALA03932Computer · faultyELAC 2 PITCH FAULT DISPLAYED ON UPPER ECAM SCREEN, F-CTL. *S/D* SEC NR 2 AND RELAY 36CE3 FAULT. REPLACED SEC NR 2 AND RELAY 36CE3, OPS CHECK GOOD.SDR 2007UALA01528Wire · detachedSEAT 1C EEL LIGHT INOP. FOUND 2 WIRES DETACHED UNDER SEAT RAIL. [SUP 06-06-07] REPAIRED EEL LIGHT WIRES UNDER SEAT 1C.SDR 2007UALA01369Unknown · sparksCREW REPORTS, DURING ENG 1 START NO N2 ROTATION WITH GOOD START VALVE OPEN INDICATION. RAMP REPORTED SPARKS FROM STARTER AREA. [06-26-07] REPLACED THE STARTER AND START VALVE. PRESENCE OF SPARKS INDICATES PROBABLE INTERNAL BEARING FAILURE RESULTING IN TURBINSDR 2006UALA01830Wire · damagedFOUND EMERGENCY EXIT PATHWAY LIGHTS INOP AT SEATS 1C, 8C, & 15C. REPAIRED WIRING AND REPLACED LIGHTS.SDR 2006UALA01296Wire · burnedFOUND BURNED FEEDER WIRE. TERMINAL ON R3782 AND/OR HARNESS ON R4388. REPLACED APU GENERATOR REF MM 24-23-51.SDR 2005UALA00641Valve · malfunctionedRECEIVED ECAM AND A FIRE ALARM FOR ENG NR 1. SHUT DOWN ENGINE. NR 1 ENGINE PRESSURE REGULATING VALVE FOR LEAKAGE AROUND SPINDLE SHAFT.SDR 2005UALA00038Battery · inoperativeEMERGENCY EXIT AISLE LIGHT INOP AT SEAT 1C. REPLACED BATTERY AND CHARGER 110WL1.