N489HA
Service difficulty reports · 59
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N489HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N489HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2026092066990Door · lack of lubeBOARDING DOOR HARD TO OPEN AND CLOSE. GROUNDED - YES. LUBRICATED AND CLEANED FWD PASSENGER ENTERANCE DOOR ASSEMBLY PER AMM 52-11-1-88277 OPS CHECK GOOD OK FOR SVC.SDR ASAA2026091966988Slide · out of positionAFTER DISARMING DOOR, SLIDE PACK FELL OUT OF THE 1L DOOR. SLIDE DID NOT DEPLOY. GROUNDED - YES. RE INSTALLED SERVICEABLE EVAC SLIDE ON 1L DOOR PER AMM 25-61-+01-400-801. NO DEFECTS NOTED, OK FOR SERVICE.SDR ASAA2026091066874Flt Controls · faultedAIRCRAFT HAD HARD ROLL TO THE RIGHT, 10 DEGREES AT GEAR EXTENSION, FLAPS 18 UNIT, 170KTS 2100FT. ASA1074 HNL LDG RWY 26L ON AS1074 ON 9/9/2026. GROUNDED - YES. COMPLIED WITH TSI-000725, ALL ITEMS HAD BEEN COMPLETED AND SUBMITTED. THE SIGNIFICANT EVENT RESPONSSDR ASAA2026082966644Flt Controls · faultedUNCONTROLLED ROLL ON SHORT FINAL. REPEAT WRITE UP, FLAPS 40, VAPP 143, 400 FEET, AUTOPILOT/AUTO THROTTLES OFF. GROUNDED - YES. COMPLIED WITH TSI-00723 ITEM 1, ALL ITEMS HAD BEEN COMPLETED AND SUBMITTED. THE SIGNIFICANT EVENT RESPONSE PROCESS HAS BEEN COMPLETESDR ASAA2026080966254Actuator · faultedACFT ROLLED 15*, RT WING DOWN WITH CLEAN CONFIG TRIM (AILERON& RUDDER) WITH FLAPS 40* & GEAR DOWN AFTER HANDS OFF CONTROLS FOR 10 SECS. GROUNDED - YES. PERFORMED FUNCTIONAL TEST OF RUDDER CONTROL SYS & RUDDER TRIM SYS IAW AMM 27-20-00-720-802/803. TESTED WITHSDR ASAA2026080566153Actuator · unserviceableON LANDING, ACFT GAVE AN UNCOMMANDED LT WING DOWN. PILOT FLYING ABLE TO COUNTER WITH RT INPUT. WING ROLLED A FEW DEGREES BUT THE YOKE DID AN UNCOMMANDED LT INPUT OF ABOUT 30 DEGREES. GROUNDED - YES. VERIFIED LT SLAT DRIVE CYLINDER ROD ENDS ARE EQUAL. VERIFIESDR HALA20250606031Lavatory · pax errorINFO TO MX FA REPORTED SOMEONE SMOKING IN LAV/STARTED A SMALL FIRE. FA EXTINGUISHED WITH WATER, NO AGENT DISCHARGE. PERFORMED PRECAUTIONARY CHECK OF LAV FIRE EXTINGUISHER. NO DAMAGE NOTED. PER AMM 26-25-01-212-801. OK FOR SERVICE.SDR HALA202401132003Unknown · unknownUPON PRE-FLIGHT FOUND OVHD EMER EXIT LTS FWD 1/2 INOP-DO NOT ILLUMINATE. REMOVED AND REPLACED EMER LIGHT BATTERY POWER SUPPLY PER AMM 35-51-03. OPS CHECK GOOD. OK FOR SVC.SDR HALA202201310032None · noneLOUD SQUEAL FROM SERVICE DOOR (R1) DURING CLIMB // REPOSITION SPONGE FILLER TO 1R DOOR PER AMM SUBTASK 52-42-00-420-001 AND APPLIED NEW SEALANT TO 1R DOOR SCUFF PLATE PER AMM SUBTASK 53-32-04-420-001. LEAK CHECK OK. OK FOR SVC.SDR HALA2021122700202Door · damagedEMER EQ - DOOR - FOUND DENT/GOUGE BELOW LEADING EDGE OF 1R SERVICE DOOR. // EDDY CURRENT SHOWS NO CRACK. #8089 12/24/21. BLEND GOUGE PER SRM 53-01-01-1A-1. MEASURED BLEND: ADJ 0.024, MIN REM:0.017; M66 SUBMITTED. 12/24/2021 MECH:015816. #5178. REMEASURED BLENDSDR HALA2021111600162None · none3 REDS AFTER GEAR HANDLE WAS DROPPED USED ALT GEAR HANDLE GOT 3 GREEN TRIED TO STOW THE AGH BUT GOT 3 REDS AGAIN // FOUND LANDING GEAR HANDLE STICKY, AND NOT GOING TO FULL GEAR DOWN DETENT.REMOVED DEBRIS AND CLEANED GEAR MECHANISM. AS PRECAUTIONARY PERFORMED FSDR HALA2021102600146Unknown · odorBTB ON PUSH BACK STARTING LEFT ENGINE FA'S SMELLED SMOKE IN CABIN // INSPECTED PAX PSU @1-2AB, NO DEFECTS NOTED, PERFORMED ENGINE RUN, COULD NOT DUPLICATE SMELL ON GROUND, OK FOR SVCSDR HALA2021091500117Door · bindingEMER EQ - FWD ENTRY DOOR HARD TO OPEN AND CLOSE // PERFORMED INSPECTION OF 1L DOOR PER AMM 52-11-01-220-801. FOUND MULTIPLE SPOTS OUT OF SPEC. NEED TO CHECK RIGGING. 021679 09/14/2021 (FAIR CONDITION) PER E105-489191-INI MISMATCH ACCEPTABLE. PER E105-C10515-PESDR HALA2021040600043Battery Pack · inoperativeEMER EQ - AFT CABIN EMERGENCY LIGHT INOP // REMOVED AND REPLACED BATTERY PACK , EMER B5-231 PER WDM 33-51-12-3.1. OPS CHECK GOODSDR HALA2021030400025Bayonet · out of adjustEMER EQ - DURING OVERNIGHT FOUND MAIN ENTRY DOOR COULD NOT CLOSE FROM OUTSIDE HANDLE. PUSH PULLGAUGE SHOWS 120LBS TO CLOSE FROM OUTSIDE HANDLE AND 80LBS TO CLOSE INSIDE HANDLE. ADJUSTED BAYONET OPERATING ROD PER AMM 52-11-01-820-811 PRESSURIZATION AND OP CHESDR HALA2021031200031Rib · crackedCRACK - RIGHT SIDE UNDERWING BARREL KEEL AREA (INSIDE) RIB CRACKED OTBD SIDE STA. 674 // REPAIR FORMER PER E105-B10214-PERM 1/25/21 MECH 13377 INSP 4884SDR HALA2021031200030Former · crackedCRACK - RH MLG DOOR FORMER P/N 9923450-504 CRACKED STA 750.2729 (M) // INSTALLED REPLACEMENT MLG DOOR FORMER P/N 9923450-504 IAW DWG# 5910783.SDR HALA2021031200029Former · crackedCRACK - RH MLG DOOR FORMER P/N 9923450-502 CRACKED UNDER REPAIR FILLER STA 745.027 (M) // INSTALLED REPLACEMENT MLG DOOR FORMER P/N 9923450-502 AT STA 745.027 IAW DWG# 5910783.SDR HALA2021030100023Battery Pack · inoperativeEMER EQ - OVERWING EMERGENCY LIGHTS DO NOT ILLUMINTAE WITH EMER LT SWITCH ON // REMOVED AND REPLACED OVERWING EMER. EVAC BATTERY POWER SUPPLY PER AMM 33-51-06. OPS CHECK GOOD. OK FOR SERVICE.SDR HALA2020030900056Smoke Warning · activatedAFT CARGO SMOKE INDICATED AT THE GATE. DISCHARGED AGENT 1. // REMOVED AND REPLACED AGENT 1 FIRE EXTINGUISHER CONTAINER IN ACCORDANCE WITH AMM 26-22-01/401 E(2)(A)7. LEAK CHECK GOOD. OPS TEST AND CLOSE UP PENDING C/B T29 AND T30 PULLED AND COLLARED. OPS CHECK GSDR HALA2019120400503Battery Pack · inoperativeEMERGENCY LIGHTS AT EXIT HATCHES DONT TURN ON WHEN SWITCH IS ON//REMOVED AND REPLACED EMERGENCY POWER BATTERY AT LOCATION B-5-121. OPS CK GOOD PER AMM 33-51-00. OK FOR SERVICE.SDR HALA2019101500414Transducer · dirtyL HYD PRESS LOW ON LDG. STEERING RESTRICTED. R(PRESSURE DROPPED TO 800PSI). // PERFORMED FIM 29-30 TASK 802. CLEANED L HYD PRESS XDCR. RAN NO.1 ENGINE. OPS CHECK GOOD. NO DEFECTS OR LEAKS NOTED. O.K. FOR SERVICE.SDR HALA2019101100409Sign · detachedEXIT SIGN NEAR FORWARD ENTRANCE WILL NOT STAY ATTACHED. SECURED EXIT SIGN REF AMM 25-60-00 SECURITY CHECK GOOD.SDR HALA2019031100110Downlock Sensor · damagedAFTER ENGINE SHUT DOWN PSEU ENGINE FAULT LIGHT ON. REMOVED AND REPLACED BOTH DAMAGED RT MLG DOWNLOCK SENSOR ASSEMBLIES, PER AMM 32-61-04-400-801. PERFORMED PSEU RTS TEST PER AMM 32-61-01 TEST OK.SDR HALA2018101200494Light · malfunctionedFA REPORTS ON TAXI OUT AND TAXI IN, EMERGENCY LIGHT SYSTEM CAME ON FOR A COUPLE MINUTES. PERFORMED FIM TASK 33-50 TASK 801. NO FAULTS NOTED, NO 10 DAY HISTORY OF FAULT NOTED. OPS CHECK OKAY. OK FOR SERVICE.SDR HALA2018090500412Wire · brokenAFT BULKHEAD DOOR EXIT MARKER SIGN INOPERATIVE. FOUND WIRE C9302-263-16 BROKEN. REPAIRED THE WIRE IAW SWPM 20-10-03, AND WDM 33-51-12. EMERGENCY LIGHTING SYSTEM OPS TESTED PASSED IAW AMM 33-51-00. OK FOR SERVICE.SDR HALA2018072600406Inverter · malfunctionedWHEN ARMING EMERGENCY PWR, EMER AC COMES OFFLINE. REMOVED AND REPLACED STATIC INVERTER PER AMM 24-24-01. OK FOR SVC.SDR HALA2018072300330Inverter · inoperativeWHEN TESTING ELEC EMERGENCY POWER GOT A/C EMER BUS OFF LT. REMOVED AND REPLACED STATIC INVERTER PER AMM 24-24-01. OPS CHECK GOOD PER AMM 24-24-00-720-803.SDR HALA2018072000326Smoke Detector · no testFWD CARGO SMOKE DETECTOR NR 8 FAILED TO TEST. REMOVED AND REPLACED THE SMOKE DETECTOR IAW AMM 26-13-01. OPS CHECKED AND SECURITY CHECKED GOOD.SDR HALA2018072000327Smoke Detector · false activationCARGO SMOKE FWD FAILED. PERFORMED AN OPS TEST OF THE SMOKE DETECTION SYSTEM IAW FIM 26-13 TASK 801. OPS CHECKED GOOD. OK FOR SERVICE.SDR HALA2018042400185Smoke Detector · unknownTESTED CARGO SMOKE DETECTOR & DID NOT TEST WITH PUSH BUTTON DEPRESSED. PERFORMED CARGO SMOKE TEST IAW AMM 26-13-01. NO DEFECTS NOTED. OK FOR SERVICE.SDR HALA2017010300575Cotter Pin · unsecureLANDING GEAR LEVER WOULD NOT MOVE TO DOWN POSITION, ON SUBSEQUENT ATTEMPTS LANDING GEAR LEVER DID NOT MOVE TO DOWN POSITION. FOUND COTTER KEY ON LANDING GEAR HANDLE ASSY SECURING LEVER ASSY TO ARM ASSY RUBBING AGAINST NR 5 DISPLAY UNIT. SAFETIED COTTER KEY ANSDR HALA2016040400101Pseu · malfunctionedWHEN LANDING GEAR EXTENDED, INDICATORS REMAINED 3 RED. RECYCLED, THEN 3 GREEN. COMPLIED WITH OPS TEST OF LANDING GEAR POSITION INDICATOR IAW AMM 32-61-06-700-801. PENDING FUNCTIONAL TEST OF MAIN AND NLG EXTENSION AND RETRACTION. ACCOMPLISHED FUNCTIONAL TESTSDR HALA2016021300041Smoke Detector · malfunctionedCARGO SMOKE TEST INOPERATIVE. RESET NR 1 AND NR 2 VIA'S. PERFORMED RTS. BOTH VIA'S PASSES. PERFORMED AMM CARGO SMOKE DETECTOR TESTS 26-13-01-710-801 AND 26-13-01-710-802. OPS CHECK OK.SDR HALA2015051500080Battery · failedDURING THE REPLACEMENT OF THE DUEL CELL LIFE VEST, PN 63600-101 WITH 66601-101 SINGLE CELL VESTS IN OUR FLEET, IS WAS DISCOVERED THAT THE BATTERIES WERE SWOLLEN AND HAD FAILED. NO VEST THAT WAS AFFECTED HAD A BATTERY FROM EARLIER THAN 2011. THERE IS NO VISIBLSDR HALA2015040500057Smoke Detector · false indicationLEVEL 1, LAV SMOKE DISPLAYED ON AIR SYNOPTIC PAGE. RESET THE CIRCUIT BREAKER AND PERFORMED FIM 26-14 TASK 801. OPS CHECKED OK.SDR HALA2015030100026Compressor · stalledOPEN-ATO-ENGINE RT COMPRESSOR STALL. REPAIR IN WORK.SDR HALA2014101800174Unknown · odorAIR DIVERSION, ODOR OF FUMES IN COCKPIT AND CABIN. THE ACFT DIVERTED TO THE NEAREST AIRPORT, WHERE AN EVENTFUL LANDING WAS MADE. REPAIRS ARE IN WORK.SDR HALA2013112600172Wire · damagedRIGHT LANDING GEAR UNSAFE, INTERMITTENT THREE TIMES DURING CRUISE. FOUND RT MLG DOWNLOCK SENSOR CONDUIT KINKED NEAR R5-3732. PIN B OF BOTH P1-1152 PUSHED BACK. REPLACED BOTH WIRE ASSY. GROUND OPS CHK OK, 32-61-00.SDR HALA2012072500182Cylinder · leakingRIGHT HYD FAILED DURING FLIGHT. FILTER POP-UP INDICATOR OK. MAN SYS FILTER CLEAN-REINSTALLED. TRANSFER CYLINDER LEAKING. R & R TRANSFER CYLINDER IAW AMM 32-33-03. OPS & LEAK CHECKED GOOD. OK FOR SERVICE.SDR HALA2012032000118Skin · unknownLIGHTING STRIKE ON RT SIDE OF FUSELAGE AT APPROX STA 614 AT LONG 27 AND LONG 26. OPENSDR HALA2012032000117Antenna · damagedLIGHTING STRIKE ON VHF NR 2 ANTENNA. REPLACED VHF NR 2 ANTENNA. PERFORMED RESISTANCE CHECK IAW SPM 20-50-01, OPS CHECKED OK MM 23-72-00, SEALED ANTENNA.SDR HALA2012032000116Skin · damagedLIGHTING STRIKE ON LT ELEVATOR T/E END CAP AND STATIC WICK BASE PLATE, AT APPROX LOCATION XHR 218.76. OPENSDR HALA2012030100091Display · malfunctionedDURING CLIMB-OUT BOTH MCDU'S WENT TO STANDBY & LOCKED. PERFORMED MM TASK 31-43-00 RTS TEST ON NR 1 & NR 2 VIA'S. NO FAULT FOUND. TEST PASSED. OK FOR SERVICE.SDR HALA2011112700541Charger · failedBATTERY CHARGER FAILED IN FLIGHT. AFTER BLOCK IN STRONG BURNING ODOR IN CABIN. R & R BATTERY CHARGER IAW AMM 24-34-03. OPS CHECK TASK 24-34-03-710-801 PASSED OK FOR SERVICE. R & R LT, CTR, RT BATTERIES IAW AMM24-34-01 - OPS TASK 24-34-03-710-801 PASSED. OSDR HALA2010100500455Sill · damagedAFT CARGO DOOR AFT SILL SUSTAINED GROUND DAMAGE. REPAIRED SEAL IAW SRM 53-20-15-2R-4.SDR HALA2010091500419Skin · crackedLEFT WING INBD DOOR 530 GB UPPER SURFACE CRACKED 1.5" LONG, VERIFIED WITH EDDY CURRENT. REPAIRED CRACK IAW SRM 57-00-00.SDR HALA2010090800420Drag Angle · crackedCRACK ON RT SIDE DRAG ANGLE, VERIFIED BY EDDY CURRENT. REPAIR IN WORK. TRIMMED OUT CRACKED AREA IAW SRM 53-30-01-2R-1. REPAIR 1. REPAIRED IAW HAL M105 FILE NR 489022.SDR HALA2010090700418Stringer Clip · cracked1.2500" CRACK ON CLIP AT STATION 1152, L2L. R & R CRACKED CLIP AT STA 1152 L2L. R & R CRACKED CLIP AT STA 1152, LONG 2L. PAINTED FUSE AT AREA OF R & R FASTENERS IAW SRM 51-22-01.SDR HALA2010030200083Control Unit · no testDURING ENGINE FIRE DETECTION FAULT TEST,"ENGINE RT FIRE" AURAL WARNING/ LIGHTS ARE DISPLAYED. REPLACED RT ENGINE FIRE DETECTOR CONTROL UNIT IAW AMM 26-11-01. OPS CK OK.