N494UA
Service difficulty reports · 92
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N494UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N494UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014102792619Stringer · corrodedMAJOR REPAIR & SDR. STRINGER 41R HAS CORROSION BETWEEN FRAME 59 & 64 IN AFT CARGO COMPARTMENT. R & R STRINGER 41R & FACTORY INSTALLED SPLICE IAW SRM 51-72-11 PGS 1 - 2. NO REQUIREMENT FOR SRI INSPECTIONS.SDR CALA2014031990636Unknown · odorELECTRICAL SMELL MID CABIN UNLOADED ACFT & CHECKED CABIN ELEC EQUIP INCLUDING SEU, READING POWER SUPPLIES & LIGHTING BALLASTS. NO NOTED EQUIP INOPERATIVE SUCH AS LIGHTING OR PASSENGER PSU'S. OPERATED PACKS, CHECKED AIR QUALITY ABOVE CEILING PANELS & E & E SDR CALA2013121693749Computer · faultySEC 1 FAULT, REPLACED SEC 1 WITH SEC 3 IAW MM. SEC 1 NOW MR 27997-137, SEC 3 NOW MR27997-1120. SEC 3 NOW INOPERATIVE & DEFERRED IAW MEL 2794A.SDR CALA2013120993563Seal · out of positionLONG PIECE OF MATERIAL COMING OFF OF LT ENG NEAR THRUST REVERSER. CNA OUTER DUCT SEAL THAT CAME OUT OF TRACK. OPENED INBD REVERSER HALF & REINSERTED SAME SEAL IAW MT78-001 & CMM 78-11-11 REPAIR 2. REVERSER HALF CLOSED IAW 78-32-00, ACFT OK FOR SERVICE.SDR CALA2013110792706Gauge · brokenCREW O2 SHOWS 1090 PSI, O2 BOTTLE PRESSURE GAUGE BROKEN. REPLACED O2 BOTTLE IAW AMM 35-11-41-000-001-A & AMM 35 -11-41-400-001-A. PERFORMED OPERATIONAL TEST OF CREW OXYGEN DISTRIBUTION IAW AMM 35-12-00-700-001-A, OK CHECKED GOOD, NO LEAKS NOTED.SDR CALA2013082990821Oxygen Mask · leakingCAPTAINS OXYGEN MASK FOUND LEAKING ON ARRIVAL INTO ORD FLIGHT 354-26, COULD HEAR AUDIBLE LEAK WITH OXYGEN ON. REPLACED CAPTAINS OXYGEN MASK & OXYGEN BOX. AFTER MASK & BOX REPLACED LT OXYGEN ON & NO PRESSURE DROP IN 3 HOURS..SDR UALA2013061404129Screw · missingON WALK AROUND FOUND FASTENER PROTRUDING FROM CENTER WING-TO-BODY FAIRING JUST FORWARD OF EXTERNAL AC PANEL. SCREW MISSING. TAPE OVER MISSING FASTENER IAW AMM 53-35-00-601 FOR 10C. PANEL NR 197AR.SDR UALA2013052303567Structure · damagedRIGHT AFT EMERGENCY DOOR REMOVED FOR MX. REF INBD FLT 681-22 PRESSURE LEAK. FOUND SEPARATED REN AT UPPER FWD AND AFT SPLICE AREAS. REINSTALLED AFT EMERGENCY DOOR IAW 52-21-11 AFTER REN REPAIR.SDR UALA2013051403352Radome · damagedDENT IN NOSE CONE. FOUND RADOME PAINT CHIPPED. MADE INTERIM REPAIR. REPLACED RADOME REF MM.SDR UALA2013040402212Transceiver · faultySTATIC FOR 10 SECONDS AFTER POWER CHANGE FROM SPEAKERS EVEN WITH SPEAKERS OFF. SEE HISTORY. FOUND WX RADAR TR UNIT CAUSING STATIC. REPLACED WX TR UNIT PER MM, OPS CHECK OKAY.SDR UALA2013040302168Warning System · false activationVENT AVNCS SYS FAULT, FLT DIVERTED. RE-ACTIVATED RIGHT TR REF MM 78-30-00. PERFORMED RIGHT TR SYSTEM TEST REF MM 78-31-00. NO FAULTS PRESENT AT THIS TIME. RAN ENG IDLE POWER FOR 5 MIN. NO FAULTS. DF REMOVED.SDR UALA2012112606739Door · damagedRT MLG DOOR DAMAGED. INSTALLED RIGHT MAIN GEAR DOOR PER AMM. IDT INSP OF RT MLG DOOR INSTALLATION AMM.SDR UALA2012102506140Battery · dischargedA-C FAILS EMERGENCY LIGHT TEST. MESSAGES EPSU BATTERY R & EPSU BATTERY L AFT. REPLACED EMERGENCY LIGHT BATTERIES AT RIGHT OVERWING EXIT (12WL) AND AT AFT LEFT (13WL) PER MM. OPS CHECK NORMAL.SDR UALA2012101505878Interface Unit · malfunctionedELEC PROBLEMS, RTFL. NEED TO CHG NR 2 EGIU PER FIM 24-20-00-810-831-A. REPALCED NR 2 EGIU PER MM. NEED TO REPLACE (4XU2)GLC AUX CT L NR 2 RELAY, PER FIM 24-20-00-810-832-A. REPLACED (4XU2) GLC 2 AUX CONTROL RELAY. REPLACED 3XU2 SWITCH RAN 124269 ENGINE TWSDR UALA2012101005769Control Unit · faultedLAVATORY AND CARGO DETECTOR FAULT DISPLAYED ON UPPER ECAM SCREEN, SMOKE. REPLACED SDCU PER AMM. OPS CHECKED GOOD, NO FAULTS AT THIS TIME.SDR UALA2012083004888Shroud · crackedBOTH FOOT REST PEDESTALS HAVE CRACKED AND MISSING TRIM PIECES. APPLIED TAPE OVER DAMAGED TRIM. IF UNABLE TO REPAIR PLS UPDATE WITH ALL PARTS NEEDED AND SCOPE OF REPAIR. RCF-P :REF IPC 27-21-01-10B, ITEM 44, COVER PLATE, PCN 110-5162, AOG S3880. 2 EA. -RCF-TSDR UALA2012082404759Antenna · vibrationGRINDING NOISE WITH VIBRATION FROM RADOME WHEN WX RADAR ON. MAINT TEXT: SEE #W2301 FOR PART AVAILABILITY INFORMATION PCN: 582-9019 SCANNER. INSTALLED NEW WEATHER RADAR ANTENNA AND OPS CHECK SATISFACTORY AS PER MM.SDR UALA2012081704589Rub Strip · looseWHISTLING SOUND ON DESCENT NOTED BY FLIGHT ATTENDANTS. INSPECTED DOOR 2L & FOUND TEFLON RUB STRIPS ABOVE DOOR LOOSE. ACCOMPLISH INTERIM REPAIR PER AMM MT 52-032. MADE TEMP REPAIR TO 2R SEE CF635 FIXED 2L BY RE-GLUING RUB STRIPS. SECURED RUB STRIPS PER MM.SDR UALA2012031601736Starter · faultyNO N2 ROTATION ENG 2 ON START- WITH GOOD APU AIR PRESSURE-34PSI. REPLACED STARTER PER AMM, OPS CHECK GOOD.SDR UALA2011112706528Buffer · stuckCAPTAIN'S RUDDER PEDAL ADJUSTMENT RESET IS STICKING. REPLACED CAPTAIN RUDDER PEDAL POSITION BUFFER, OPS CHECKED OKAY.SDR UALA2011112706480Buffer · faultyF/O RUDDER PEDALS DO NOT SELF ADJUST OUT. REPLACED RUDDER PEDAL POSITION BUFFER, OPS CHECKED OKAY.SDR UALA2011100505404Oxygen Mask · leakingSAMC TEXT: PRESSURE DROPPING ABOUT 10 PSI PER MINUTE. NO NOTICEABLE LEAKS AT MASKS. FOUND CAPTAINS O2 MASK LEAKING AND TEST FUNCTION INTERMITTENT. REPLACED MASK AND SWAPPED BOX TO 2ND OBSERVER POSITION REF AMM NEW CRUSH WASHERS INSTALLED AND LEAK CHECKED OSDR UALA2011092005078Valve · faultyAFT CARGO HOT AIR VALVE WILL NOT OPEN. TRIED RESET, NO HELP. REPLACED PRV VALVE, OPS CHECKED GOOD, NO FAULTS NOTED.SDR UALA2011060202700Unknown · odorCREW REPORTS AFT GALLEY BURNING SMELL WHICH SMELLED LIKE BURNT POPCORN. MAINT TEXT: FLT CREW VERBAL, FLT ATT REPORTED BURNT POPCORN SMELL AROUND ROW 25-26 THAT WAS INTERMITTENT DURING DESCENT AT 25000', TURNED AFT GLY PWR OFF PER SAMC. SMELL ISOLATED TO AFTSDR UALA2011050902295Plate · dirtyF/A REPORTS BURNT TOAST SMELL IN AFT GALLEY. F/A REPORTED SMELL IS STRONGER IN EMER EQUIP CUBBY. MAINT TEXT: PILOT INFORMED MECHANIC AFTER APPROX 1 HR OF FLIGHT TURNED OFF ALL GALLEY POWER AND SMELL WENT AWAY. PILOT LEFT GALLEY POWER OFF REST OF FLIGHT. RSDR UALA2011030801141Computer · faultyFUEL DISCREPANCY. FUEL SHUT OFF EARLY. GALLONS ADDED CORRECT BASED ON INBD FUEL LOAD. SMB EARLY DAYS VENTING TANK. PLAN TANK ENTRY ON DAYS TO REPLACE CONDENSICON ON DAY SHIFT. REPLACED BOTH MAGNETIC LEVEL INDICATOR & HOUSING PER MM.SDR UALA2011011900309Unknown · odorCREW REPORT: CABIN ODOR IN AFT GALLEY HOT RUBBER ODOR. INSPECTED ALL EQUIPMENT IN AFT GALLEY INCLUDING LIGHTS, ALSO CHECKED LIGHT IN AFT LAVS, RAN PACKS, UNABLE TO DUPLICATE ODOR.SDR UALA2010090903340Smoke Detector · faultyLAVATORY DETECTOR FAULT DISPLAYED ON UPPER ECAM SCREEN. - SMOKE REPLACED LAVATORY A SMOKE DETECTOR, TESTS NORMALSDR UALA2010082603164Unknown · vibrationAIRFRAME VIBRATION DURING CLIMB FL300 - FL360..78M. CAN DAMPEN WITH RIGHT RUDDER. REPLACED BLUE SYSTEM RUDDER SERVO. TROUBLESHOOTING ACP'D.SDR UALA2010071402520Oxygen System · dischargedUPON ARRIVAL TO GATE O2 DROP TO 0 PSI SERVICED O2 TO FULL 1900 PSI AT 24 DEGREES C. ACCOMPLISHED TSM TASK 35-10-00-810-813 LEAK CHECK OF LOW AND HIGH PRESS CIRCUITS HAD NO LEAKS. CHECKED ALL CONNECTIONS ARE THE CORRECT CONDITION. PRESSURE REMAINING AT 1900 PSSDR UALA2009070201907Gcu · faultyLOST BOTH GENERATORS. RTFL. RMV'D & RPL'D NR 1 & NR 2 GCU(S) DUE TO RECENT LOSS OF POWER. CKS OK WITH CFDS. RAN ENG, OPS OKAY.SDR 2008UALA04355Wire · crossedCREW REPORT: EMERGENCY EXIT SIGN AT LEFT OVERWING EXIT INOP.SDR 2008UALA04044Outflow Valve · illuminatedBLOWER FAULT DISPLAYED. RTFL. PFR SHOWS SKIN AIR OUTLET VALVE 22HQ FAULT. REPLACED SKIN VALVE. OPS CHECKS GOODSDR 2008UALA02861Skin · dentedFOUND DENT ON BOTTOM OF FUSELAGE JUST FWD OF THE FRONT E-E DOOR. MAJOR REPAIR ACCOMPLISHED, INSTALLED DOUBLER REPAIR.SDR 2008UALA02860Skin · dentedDENT IN FWD LOWER FUSELAGE JUST LEFT OF GROUND COMMUNICATION ACCESS DOOR FWD OF E/E DOOR. MAJOR REPAIR ACCOMPLISHED, INSTALLED DOUBLER REPAIR.SDR 2008UALA02859Skin · gougedGOUGE FOUND JUST BELOW AND FWD OF O2 SVC ACCESS DOOR ON LEFT SIDE OF FUSELAGE AT FRAME 13, BETWEEN STRINGERS 21 AND 27, 3 INCHES LONG AND .015 INCH DEEP. MAJOR REPAIR ACCOMPLISHED, INSTALLED DOUBLER REPAIR.SDR 2008UALA02462Connector · looseFLOOR PROXIMITY EMERGENCY ESCAPE PATH LIGHT OUT AT SEAT 26C. FOUND LOOSE PLUG. SECURED PLUG AND LIGHTS TEST OK.
SDR 2008UALA02174Oxygen System · reads lowFOUND CREW O2 LOW 1430 PSI. SERVICED CREW O2, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2007UALA04875Connector · damagedROW 11 EMERGENCY AISLE LIGHT INOP. FOUND CONNECTOR FOR THE EEL LIGHT AT ROW 11 HAD BEEN DAMAGED. REPAIRED CONNECTOR FOR EEL HARNESS, NO REPEATS.SDR 2007UALA01934Rod End · wornVIBRATION - NOISE ENCOUNTERED IN FLIGHT. SERVO ROD END WORN ON YELLOW HYD RUDDER SYS. REPLACED YELLOW SYSTEM RUDDER SERVO ROD END. ALSO REPLACED SEALS ON YELLOW SYS HYDRO CONNECT PANEL, LEFT AND RIGHT.SDR 2004UALA01234Proximity Sensor · malfunctionedLANDED UNDER AMBER ALERT DUE TO NOSE GEAR INDICATION. NORMAL LANDING BUT NO NOSE WHEEL STEERING AND HAD TO BE TOWED IN. MLG UNSAFE INDICATION ON FWD PANEL WITH ECAM DOOR NOT CLOSED AND NW STEERING FAULT PER POST FLIGHT REPORT, FOUND NLG DOWNLOCK PROX SENSOR 1SDR 2004UALA00392Bpsu · failedON TAXI OUT, COMPLETE LOSS OF NOSE WHEEL STEERING AND BRAKING. ALSO EXPERIENCED UNCOMMANDED LEFT TURN. BRAKE SYSTEM CONTROL UNIT (BSCU) FAILED. BRAKE SYSTEM CONTROL UNIT (BSCU) REPLACED, NOSE WHEEL ANTISKID STEERING SWITCH REPLACED. OPERATIONS CHECK NORMAL.