N495UA
Service difficulty reports · 112
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N495UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N495UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2021091701596Shear Plate · crackedAFT CABIN R/H SIDE FLOOR STRUCTURE LATERAL SHEAR PLATE CRACKED A PPRX 5" AFT FR69.SDR CALA2021091501573Floor Support · corrodedCORROSION ON CABIN FLOOR SUPPORT AT APPRX Y-1673 AT FR20.SDR CALA2019060700906Ring · brokenPDA 1 #2 INBOARD TR BULLNOSE FOUND TO MISSING ,FOWARD OF BLOCKER DOORS. THIS WAS FOUND DURING AN OVERNIGHT SERVICE CHECKSDR CALA2018041801179Bulb · inoperativeFWD LT WINDSCREEN EMERGENCY LIGHT NOT FUNCTIONAL. REPLACED THE BULBS IN THE EMERGENCY LIGHT, OPS CHECKED GOOD IAW AMM 33-51-20-400-001C3.SDR CALA2017091503208Slide · low pressureR1 DOOR SLIDE PRESSURE GAUGE ON GREEN LINE. REPLACED THE SLIDE IAW AMM 25-62-44.SDR CALA2017071002183Power Supply · malfunctionedPER 2 SVC, EPSU BATT EMER L DISPLAYED ON CIDS PANEL. RESET EMRG LT CB, RERAN SYS BITE TEST, ALL CHKS OK.SDR CALA2017071002182Battery Pack · dischargedPER 2 SVC EPSU BATT EMER R DISPLAYED ON CIDS PANEL. REPLACED EPSU BATTERY PACK, CHKS GOOD.SDR CALA2017071002181Battery Pack · dischargedPER 2SVC EMER EXIT LITE TEST FAILS EPSU BATT FWD L. WITH EMER SWITCH ARMED AND POWER OFF AIRCRAFT, NONE OF THE EMERGENCY LIGHTS COME ON ENTIRE AIRCRAFT. REPLACED FWD L EPSU BATTERY PACK, CHKS GOODSDR CALA2017060501670Outflow Valve · faultedSYS 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. CABIN PRESSURE. EMERGENCY DECLARED. REMOVED AND REPLACED NR 1 CPC IAW AMM 21-31-34. OPS CHECKED GOOD. REMOVED AND REPLACED THE OUTFLOW VALVE IAW AMM 21-31-51-400-001-A. NO FAULTS NOTED.SDR CALA2017021300356Unknown · odorON DESCENT HEAVY ODOR FROM A/C VENT. SUSPECT ENGINE OIL PERFORMED ENGINE RUNS AND RAN PACKS, NO DEFECTS NOTED REF TSM 71-00-00-810-801-A13.SDR CALA2016090195710Power Supply · malfunctionedEMERGENCY LIGHTS FAILED TEST . MESSAGE FOR EPSU BATTERY. RESET OVERWING LEFT POWER SUPPLY UNIT, RAN TEST AGAIN, NO FAULTSSDR CALA2015021093074Stringer · corrodedAFT CARGO COMPARTMENT STRINGER 43L CORRODED AT FRAME 56 - 59, TOP SURFACE & UNDERSIDE AROUND FLANGE. ACCOMPLISHED STRINGER REPAIR ON NR 9710677 IAW SRM 53-00-13 FIG 201 PG 211 DETAIL H. STRINGER REPLACED FROM FRAME 56 - 59.SDR CALA2015010992921Stringer · corrodedAFT CARGO COMPARTMENT STRINGER 43L CORRODED AT FRAME 56 - 59 TOP SURFACE & UNDERSIDE AROUND FLANGE. ACCOMPLISHED STRINGER REPAIR ON NR 9710677 IAW SRM 53-00-13 FIG 201 PG 211 DETAIL H. STRINGER REPLACED FROM FRAME 56 TO 59.SDR CALA2014081491987Slide · faultyEMERGENCY LIGHT TEST FAILS. MSG EPSU EXT LOAD AFT LT. R & R L2 DOOR ESCAPE SLIDE PACK ASSEMBLY IAW AMM 25-62-44. PLACARD REMOVED.SDR CALA2014071191425Control Unit · malfunctionedNUMBER 2 GENERATOR WILL NOT COME ON LINE, LOW VOLTS. ACCOMPLISHED NR 2 IDG CONTROL UNIT RESET IAW TSM -24-22-00-810-818. RAN BOTH ENGS PERFORMED LOAD SHED ON AC BUS, NR 2 ENG IDG OPERATIONS CHECKED NORMAL.SDR CALA2014051691033Slide · faultyEPSU EXT LOAD AFT LT, EPSU COMM EMER LT FAULTS ON EMERGENCY LIGHT TEST. ACCOMPLISHED TSM 33-51-00-810-808A FOUND SHORT IN DOOR 2 LT SLIDE PACK, FAULTS GO AWAY WITH SLIDE JUMPED. WILL NEED NEW SLIDE PACK MR25823. REPLACED DOOR 2 LT SLIDE IAW AMM 25-62-44-400SDR CALA2013103092516Battery · faultyBCL1 FAULT DISPLAYED ON UPPER ECAM SCREEN, ELEC. REPLACED NR 1 BATTERY CFDS BITE ON BCL, CHECKED OK IAW MM 24-38-51.SDR CALA2013082190620Smoke Detector · faultyAVIONICS SMOKE ECAM, RETURN TO FIELD. NO VISIBLE OR ODOR OF SMOKE. REPLACED DETECTOR.SDR CALA2013082090581Light · inoperativeEMERGENCY LIGHTS TEST AT L1 DOOR FAILS FOR 'EPSU EXT LOAD AFT L'. FOUND THAT DOOR SLIDE 2 RIGHT IS BAD, PER FIM 33-51-00-810-808- A STEP X,2,D. VERIFIED THAT AFT LEFT SLIDE IS GOOD AND AFT RIGHT SLIDE IS BAD. REPLACED R2 DOOR SLIDE ASSY PER MM, OP CHECKEDSDR CALA2013080790230Light · burned outEMERGENCY LIGHT BURNED OUT AT ROW 10 REPLACED EMERGENCY LIGHT, CHECKED OK.SDR CALA2013082990855Battery Pack · faultyEMERGENCY EXIT LIGHTS TEST SHOWS FORWARD BATTERY MESSAGE. REPLACED FORWARD BATTERY PACK.SDR UALA2013060603950Power Supply · inoperativeACCOMPLISHED EMERGENCY LIGHT TEST VIA CIDS PANEL, HAD FAULT EPSU AFT LEFT. ACCOMPLISHED TEST VIA PWR SUPPLY AND FAULTED UNIT ASSY. REPLACED POWER SUPPLY AND BATTERY, SYS OP'S CK'S NORMAL.SDR UALA2013041202517Slide · unserviceableLEFT OVERWING SLIDE DOOR HAS LOCK PINS PAINTED. REPLACED SLIDE PER MM 25-62-42 ON WU Y3409H.SDR UALA2013040102062Water System · contaminatedAFT GALLEY LOUD CHATTERING NOISE AFTER APU BLEED TURNED ON. BLEED AIR OUT OF AFT GALLEY WATER. CHATTERING STOPPED. OK FOR SERVICE.SDR UALA2013011400201Unknown · unknownL2 DOOR FAILED EMERGENCY LIGHT TEST. EXTERNAL LOAD FAULT LEFT AFT. FOUND AFT EPSU LIGHT FAULT, CHANGED AFT EPSU, NO HELP. REPLACED ESCAPE SLIDE PACK R2 DOOR. EMERGENCY LIGHT TEST PASSED.SDR UALA2012122107353Slide · faultyCABIN EMERGENCY LIGHTING CHECK FAULTING "EPSU EXT LOAD AFT L". COMPLIED WITH MEL. REPLACED SLIDE, EMERGENCY LIGHTS TEST GOOD.SDR UALA2012121707279Power Supply · faultyEPSU COMM EMERGENCY LIGHT FAULT WHILE ACCOMPLISHING EMERGENCY LIGHT TEST. REPLACED EMERGENCY POWER SUPPLY AND BATTERY L2. OPS CHECKED GOOD.SDR UALA2012121707278Slide · faultyEXTERNAL LOAD EMERGENCY AFT L FAULT WHILE ACCOMPLISHING EMERGENCY LIGHT TEST. EPSU RESET NO HELP. REPLACED NR 2 LEFT MED SLIDE PER AMM. LIGHT TEST GOOD. ACP INSP OF SLIDE INST REF AMM. VERIFIED SAFETY PINS WERE REMOVED AND STOWED. SLIDE INDICATIONS, ALL SDR UALA2012102206034Apu · malfunctionedAPU AUTO SHUTDOWN EGT SPIKED RED VIBRATION AND EXTERNAL SMOKE :WILL DEFER APU INOP PER MEL 4910B OPB HAS BEEN ADVISED. TOMC-EMC INSPECTED INLET AND EXHAUST NO DEFECTS NOTED. CFDS APU SHUTDOWNS HAS 'FUEL CTL UNIT' FAULT. ACP OPERATIONAL TEST PER AMM49-00-00SDR UALA2012100505655Battery · failedEMERGENCY LIGHT TEST FAILS (SHOWS EMERGENCY AFT LEFT). REPLACED BATTERY. SYSTEM TEST OKAY, NO FAULTS NOTED.SDR UALA2012090404953Battery Pack · inoperativeEMERGENCY LIGHT TEST FAILS WITH MESSAGE EPSU EXTERNAL LOADS AFT L. REPLACED DOOR 2L SLIDE PER AMM, REPLACED EPSU BATTERY AT DOOR 1L EMERGENCY LIGHT CHECK PASSES.SDR UALA2012082204685Proximity Switch · looseLEFT FORWARD CABIN MESSAGE IS INTERMITTENT. FOUND PROX SWITCH 13WV1 BACK SIDE LOOSE, REFERENCE CH3572 AND WDM31-54-41. REPLACED HANDLE PROX SWITCH 13WV1 PER MM, ADJUSTED PROX SWITCHES 13WV1 AND 11WV1 PER MM. DOOR INDICATION OPS CHECKS NORMAL.SDR UALA2012082204690Fwc · faultyLEFT FORWARD CABIN DISPLAYED ON UPPER ECAM SCREEN. PANEL 1WN1 PREVIOUSLY REPLACED ON 7-12. PRESSURIZED AIRCRAFT AND CHECKED DOOR INDICATION. ALL CHECKS NORMAL. REPLACED NR 1 FLIGHT WARNING COMPUTER 1WW1, REF SEQ 2662004.SDR UALA2012081404510Smoke Detector · faultedSMOKE DETECTOR STATUS MESSAGE. REPLACED SDCU, NO HELP. REPLACED FWD CARGO COMPARTMENT AFT SMOKE DETECTOR, GROUND CHECKED NORMAL.SDR UALA2012081004347Warning System · false activationLT FWD DOOR INDICATION. CHECKED VISIBLE WIRES, NO DEFECT NOTED. REPLACED SDAC-1, OP CHECK GOODSDR UALA2012072504050Radome · delaminatedRADOME HAS DELAMINATED OR PAINT CHIPS DOWN TO BRIGHT GREEN SURFACE. RADOME REPLACED.SDR UALA2012052202880Warning Light · false activationNOSE WHEEL STEERING DISCONNECT AMBER MSG DISPLAYED AFTER GEAR RETRACTION. NO FAULTS RECORDED FOR PAST TEN FLT LEGS PER TSM 32-51-00-810-833-A PARA 4.A.(1)(B). NO MAINT ACTION TAKEN.SDR UALA2012022000986Fastener · missingENG 1 HAS MISSING RIVET FROM PEN NIB FAIRING RT SIDE: ONE RIVET MISSING. INSTALLED NEW FASTENER IAW MT 78-001.SDR UALA2011121506887Mask · unsecureCREW REPORT: ROW 24 O2 PANEL MASKS HANGING DOWN. FOUND RUBBER HOSE SEALING SECTION BETWEEN OXY MASK CONTAINER AND COVE LIGHT DANGLING: SECURED REF MM 25-23-48. UPDATE: RIGHT SIDE ROW 24.SDR UALA2011082604581Proximity Switch · faultyDOOR 2R SLIDE INDCATION ARMED WENT OUT IN FLIGHT DOOR 2R SLIDE INDICATED DISARMED AIRBORNE UNTIL F/A RE-ARMED IT. F/A REPORTED, INDICATION ON DOOR NOT LINED UP RIGHT. PRESSURIZED AIRCRAFT PER JRH NO DEFECTS FOUND ON ECAM FOR SLIDE INDICATION FOR DOOR 2R. VISDR UALA2011081904409Shutoff Valve · inoperativeNR 1 ENG HYD FIRE SHUT-OFF VALVE INOPERATIVE. ACCOMPLISHED ON DOCK WU E6244G AND OPS CHECKED OKAY.SDR UALA2011050302172Circuit Breaker · faultyCB'S ARE TRIPPING. ASSURE ALL WIRING THAT WAS EFFECTED UNDER EG5429 WAS DONE PROPERLY AND IS PROPERLY ROUTED. AFTER REPLACEMENT OF CB 9002ML3 AND REPLACEMENT OF 9004ML3 CB ALL CB AND GALLEY EQUIPMENT CHILLERS,WORK LIGHTS, COFFEEMAKERS & CBS OP CHECKED OKAY.SDR UALA2011011400226Oxygen Mask · defectiveCOCKPIT 2ND OBSERVER'S SEAT O2 MASK IS DEFECTIVE. REPLACED MASK AND ACCOMPLISHED OPS CHECKED PER AMM.SDR UALA2010111004179Flap Track · dentedDENT IN RT OB FLAP TRAILING EDGE. APPROX 1. 5 FT IB OF OB FLAP TRACK FIRING. MEASURES APPROX 1.5IN BY 2IN. .0 85 IN. IN DEPTH. REPAIRED PER GNMM 1-0-1-24.SDR UALA2010110104042Coffeemaker · odorBURNED PLASTIC ODOR EMANATING FROM COFFEE POTS IN REAR GALLEY. M41 OR M42. DEACTIVATED BOTH AFT GALLEY COFFEEMAKERS (PRECAUTIONARY). REPLACED BOTH COFFEEMAKERS M-41 & M-42. RESET C-B'S & CHECKED AFT GALLEY CONDITION. ALL CHECKS GOOD.SDR UALA2010061402073Oxygen Mask · leakingCREW O2 PRESSURE AT 1750 AS REPORTED BY CREW. O2 SERVICED EARLIER TODAY. PERFORM VISUAL AND AUDIBLE CHECK OF O2 CONNECTORS AT BOTTLE. CHECKED SECURITY OF ALL 4 CREW O2 MASKS. FOUND LEAK IN THE 1ST OBSERVERS OXYGEN-MASK STOWAGE-BOX. WILL NEED STOWAGE BOX (USDR UALA2010032200942Pbe · unserviceableFLT DECK PBE PACK IS SOFT NEEDS REPLACEMENT PCN 649-2710. 0 STOCK IN DEN. REPLACED FLT DECK PBE.SDR UALA2009121503881Cable · frozenDOOR 2L WILL NOT ARM PROPERLY. PAY PARTICULAR TO GIRT BAR FLEX CABLE FOR POSSIBLE FREEZING DUE TO WATER INTRUSION. LUBRICATED FLEXIBLE CONTROL ASSY DUE TO WATER INTRUSION. DOOR SLIDE ARMS NORMAL.SDR UALA2009121103817Slide · reads lowDOOR 1R SLIDE PRESSURE IS OUTSIDE THE GREEN BAND AND NEEDS TO BE REPLACED. REMOVED DOOR 1R SLIDE PACK. REPLACED SLIDE.SDR UALA2009081702508Safety Valve · faultyNOSE GEAR UNSAFE LIGHT, FLIGHT DIVERTED. LGCIU GIVING ERRONEOUS PROXIMTY SENSOR MESSAGES ON UPPER ECAM. REPLACED NR 1 LGCIU. AT GEAR EXTENSION NO SAFE INDICATIONS FOR EITHER UPPER GEAR LIGHTS OR ON LOWER ECAM WHEEL. REPLACED NOSE GEAR DOOR OPENING SAFETY V
Back to N495UA