Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N508DN' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N508DN' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026022601368Engine · odorON TAXI OUT AFTER BOTH ENGINES RUNNING PILOTS NOTIFIED AN ODOR THEN CONFIRMED WITH FLIGHT CREW THROUGH THE AIRCRAFT. PERFORMED T/S PER TSM A350 21-21-XX-54001-421A-A. UPON RUNNING THE NBR 1 ENG, AN OIL ODOR WAS DETECTED. INSPECTED ENG AND AREA NO LEAK NOTED. PSDR DALA2025120108773Eec · faultedDIVERTED TO SEA DUE TO RIGHT ENGINE THRUST LEVER FAULT MESSAGE. CORRECTIVE ACTION: C/W RIGHT ENGINE FADEC SYSTEM TEST, NO FAULTS NOTED. REPLACED NR 2 ENGINE EEC, LOADED SOFTWARE AND EEC 2A, 2B FADEC SYSTEM AND EEC CONFIGURATION CHECK IAW A350 AMM 73-21. REMOVESDR DALA2025102207747Light · no testDURING PDC CK - DISPATCH MSG CABIN EMERGENCY EXIT LIGHT. PERFORMED EPSU SYSTEM TEST AND FAULTED DOOR 3L LIGHT UNIT. CONFIRMED EXTERIOR LIGHT INOP. R & R LIGHT ASSEMBLY P/N 8607-2-00 AND OPS TEST OK IAW A350 AMM 33-51. OK FOR SERVICE. (LP# 8151470)SDR DALA2025082606340Pump · faultedRETURNED TO HND DUE TO LEFT ENGINE OIL QUANTITY AT ZERO. OIL PRESSURE AND TEMPERATURE GOOD. R & R LEFT ENGINE OIL PUMP AND SCAVENGE FILTER. SERVICED LEFT ENGINE OIL TANK. (LP# 7295079)SDR DALA2025082806385Module · disconnectedSEAT 4A EMERGENCY FLOOR PATH MARKING LIGHT IS OUT. WHILE PERFORMING VISUAL INSPECTION OF EMERGENCY LIGHT MODULE NOTICED CABLE POLARITY WAS REVERSED. RECONNECTED LED MODULE REF. CMM 33-52-20. OPS NORMAL. NO FURTHER ISSUES NOTED. (LP# 7295066)SDR DALA2025052804112Anti-Ice Valve · faultedSHIP 3508 -DIV- DIVERTED TO LAX DUE TO ENG 1 STATOR ANTI ICE VALVE CLOSED MSG. UNABLE TO CONTINUE THROUGH ICING CONDITIONS. CORRECTIVE ACTION: FOUND DAMAGED HARNESS 4327KS1. REPLACED SAME NO FURTHER FAULTS. (LP# 7446868)SDR DALA2025040702678Elec Connector · detachedGROUND FLOOR PATH LIGHT AT 40C INOP DURING SERVICE CHECK. RE-ATTACHED SEAT 40C CONNECTOR REF ESPM CH.20. MEL & PLACARD REMOVED. (LP# 7164402)SDR DALA2025020300787Tire · low pressureWHEEL TIRE PRESSURE LOW DISPATCH MESSAGE. REPLACED BOTH L&R NOSE WHEEL ASSEMBLY PER A350 AMM32-41. SECURED OK. PRESS NORMAL. (L/P# 6947638)SDR DALA2024101510099Grill · damagedLAVATORY SMOKE DETECTOR GRILL DAMAGED / LOCATIONS:207 / MYCABIN TEXT: FRC261703207 SOMEONE WANTS TO SMOKING INSIDE THAT THREE LEFT INDOOR BATHROOM, BUT THE SMOKE DETECTOR DID NOT GO ON ... BATTERY?? / INTERIOR. BITE TEST OF SDS AND WARNING TEST ARE PASSED. OK SDR DALA2024101109969Battery · failedWHILE WORKING LOG 0512079, SYSTEM FAULTED EPSU AT 3L. TROUBLE SHOOT FOUND EPSU BATTERY BAD. R/R BATTERY AT 3L (101WL3) REF A350 AMM 33-51 OPS CHECKS GOOD. OK FOR SVC. (LP# 6474403)SDR DALA2024020801747Floor Panel · damagedNRC 150-009,MTC TASK AFT CARGO FLOOR PANEL 152MAF AND 152PAF FOUND SPONGY. AFT CARGO FLOOR PANEL 152PAF REMOVED AND REPLACED WITH NEW ONE I.A.W. AMM A350-A-53-XX-XX-03001.DUE TO NIL STOCK, AFT CARGO FLOOR PANEL 152MAF TEMPORARY REPAIR CARRIED OUT I.A.W.ASR A35SDR DALA2024020701674Bushing · migratedDURING CCK AT STEASC (SCO), THE LH HORIZ STAB LATERAL LOAD FITTING UPPER BUSHING WAS FOUND MIGRATED. A REPAIR WAS ACCOMPLISHED PER SECT I OF ERA 615306-14. THE REPAIR ACCOMPLISHED PER SECT I OF ERA 615306-14 IS APPROVED FOR 40,744 TOTAL FC FROM FIRST FLIGHT. CSDR DALA2024020701673Bushing · migratedDURING CCK AT SCO, THE RH HORIZ STAB LATERAL LOAD FITTING LOWER BUSH WAS FOUND MIGRATED. A REPAIR WAS ACCOMPLISHED PER SECT I OF ERA 615303-14. THE REPAIR ACCOMPLISHED PER SECT I IS APPROVED FOR 40,744 TOTAL FLIGHT CYCLES FROM FIRST FLIGHT. CONTACT LIAISON ENGSDR DALA2024012901330Sealant · unknownAD/EM-EO TASK - RH WING W/C 5720-01102-05B STEP 24. TO GENERATE A STANDALONE "SDR" LOG PAGE AND ENSURE "SDR REPORTABLE" CHECKBOX IS MARKED. RH WING SEALANT APPLIED AS PER W/C 5720-01102-05B STEP 11. FOUND SATISFACTORY AND W/C STEP 24. "SDR REPORTABLE" CHECKBOXSDR DALA2024012901329Sealant · unknownAD/EM-EO TASK - LH WING W/C 5720-01102-05A STEP 24. TO GENERATE A STANDALONE "SDR" LOG PAGE AND ENSURE "SDR REPORTABLE" CHECKBOX IS MARKED. LH WING SEALANT APPLIED AS PER W/C 5720-01102-05A STEP 11. FOUND SATISFACTORY AND W/C STEP 24. "SDR REPORTABLE" CHECKBOXSDR DALA2024012901328Sealant · unknownAD/EM-EO TASK - RH WING W/C 5720-01102-02B STEP 25. TO GENERATE A STANDALONE "SDR" LOG PAGE AND ENSURE "SDR REPORTABLE" CHECKBOX IS MARKED. RH WING DETAILED INSPECTION OF THE SEALANT CARRIED OUT AS PER W/ C 5720-01102-02B STEP 6. FOUND SATISFACTORY AND W/C STESDR DALA2024012901327Sealant · unknownAD/EM-EO TASK - LH WING W/C 5720-01102-02A STEP 25. TO GENERATE A STANDALONE "SDR" LOG PAGE AND ENSURE "SDR REPORTABLE" CHECKBOX IS MARKED. LH WING DETAILED INSPECTION OF THE SEALANT CARRIED OUT AS PER W/ C 5720-01102-02A STEP 6. FOUND SATISFACTORY AND W/C STESDR DALA2023070205282Unknown · unknownAIRCRAFT 3508, DURING SERVICE CHECK FOUND EMERGENCY PATHWAY LIGHTS AT 37ABC AND 39ABC INOP. CORRECTIVE ACTION: FOUND BROKEN WIRE FROM TERMINAL END ON EEPMS CABLE AT SEAT 37 C, REPAIRED WIRE. (LP 8985632)SDR DALA2023061204776Unknown · unknownSHIP 3508 DURING SVC CHECK FOUND DOOR 1L, 2L, AND 4L MIDDLE GUIDE ROLLER/ BEARING DAMAGED. CORRECTIVE ACTION: REMOVED AND REPLACED MIDDLE GUIDE ROLLER/BEARING ON DOOR 1L, 2L, AND 4L. (4199892)SDR DALA2023050103366Unknown · unknownAIRCRAFT 3508, PANEL MISSING ON CENTER AFT LOWER OF ENGINE 2. NO INDICATION IN FLIGHT OR ON GRD. CORRECTIVE ACTION: REPLACED NBR 2 ENGINE THRUST REVERSER LATCH ACCESS DOOR ASSY. (LP 4697945)SDR DALA2022050503146None · noneSHIP 3508 - ELECTRONIC BURNING SMELL AROUND 6B ON SHORT FINAL. CORRECTIVE ACTION: AREA UNDER SEAT CHECKED, NIL SIGNS OF BURNING. ALL WIRING & ACTUATORS SECURE & NORMAL. SEAT OPERATED SEVERAL TIMES & PC POWER CHARGING CHECKED, ALL OPS NORMAL.(8820595)SDR DALA2022040502309Light · inoperativeSHIP 3508 - RIGHT SIDE EMERGENCY LIGHTS WILL NOT TURN OFF. CORRECTIVE ACTION: AT R1 DOOR DISCONNECTED EMERGENCY BAT AND RECONNECTED BATTERY AND OPS NORMAL IN ALL SWITCH POSITIONS. (8818234)SDR DALA2021041302170Oxygen Mask · unwanted deploySHIP 3508 ROW 39DEF O2 MASK DEPLOYED. CORRECTIVE ACTION: REPLACED O2 CONTAINER COVER PER A350 CMM. PERFORMED CABIN O2 MASK DROP TEST PER A350 AMM 35-21. DOOR DROP AND RESET COMPETED. (7450150)SDR DALA2021020300637Oxygen System · inoperativeSHIP 3508 OXYGEN MASKS DROPS OPEN (NO FLOW). IN DRESSING OF PILOT CREW REST AREA. CORRECTIVE ACTION: CONFIRMED OXIGEN NOT DISCHARGED. LATCH MASKS OK. STOW AND SECURED PANEL PER A350 AMM 35-21. (7694208)SDR DALA2021012200451Sleeve · missingDOOR 1R AFT OUTER TAPER PIN SLEEVE MISSING. CORRECTIVE ACTION: INSTALLED MISSING SLEEVE.SDR DALA2020081982826Electrical Sys · faultedDIV- TO DTW DUE TO MULTIPLE ELECTRICAL ISSUES AND ENGINE BLEED ISSUE. CORRECTIVE ACTION: REPLACED EENMU-1A (EMERGENCY ELECTRICAL NETWORK MANAGEMENT UNIT) AND EMERGENCY POWER CONTACTOR. TEST OK.SDR DALA2020012300545Master Switch · faultedINFLIGHT SHUTDOWN, DIVERTED DUE TO MULTIPLE ECAM MESSAGES AND RIGHT ENGINE INFLIGHT SHUTDOWN. FOUND FAULT ON NR 2 ENGINE MASTER SWITCH. REPLACED INTEGRATED CONTROL PANEL. LP 6695790SDR DALA2021020100613Floor Panel · damagedSHIP 3508 FLOOR PANEL LEFT AISLE FRAME 37 TO 42 DAMAGED 10"X4". CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR PANEL AT LOCATION LEFT AISLE FRAME 37 TO 42 PER A350 AMM.SDR DALA2019052403186Power Supply · faultedDURING EPSU TEST, POWER SUPPLY 102WL2 FAULTED. REPLACED EPSU 102WL2. LP 5427697
Back to N508DN