N522ME
Service difficulty reports not matched to an aircraft · 23
They name N522ME, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N522ME' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N522ME' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR E3MA20110118004Reinforcement · crackedCRACKS FOUND EMANATING FROM LOWER 5 HI-LOK FASTENERS IN TITANIUM REINFORCEMENT LOCATED AT FRONT OF NR 1 ENGINE DECK. THIS RE-ENFORCEMENT IS ATTACHED TO THE AFT SIDE OF FRAME 5 IN THE AIRCRAFT FUSELAGE. MANUFACTURER HAS BEEN NOTIFIED AND REPAIR ORDER REQUESTESDR 0703070144Actuator · leakingLEAKING FLUID FROM WEEP HOLE.SDR 0627070144Actuator · leakingLEAKING FLUID FROM HOUSING BEYOND SERVICEABLE LIMITS.SDR 0613070144Bearing · wornSPHERICAL BEARING ON INPUT SHAFT, WORN.SDR BAQA094194Panel · crackedPANEL HAD STRESS CRACK IAW SITE MECHANIC, UPON REMOVAL, PANEL SHATTERED AND MECHANIC SCRAPPED ON SITE. REPLACED WITH SERVICEABLE PANEL FROM AEC, 04/16/2004SDR BAQA093759Mount · leakingLEAKING FLUID, AND RETRACTED ALL THE WAY INTO UNIT. REPLACED WITH SERVICABLE UNIT. 03/26/2004SDR BAQA093758Mount · leakingLEAKING AND RETRACTED TOO FAR. REPLACED WITH SERVICABLE UNIT. 03/26/2004SDR BAQA092349Mount · leakingUNIT LEAKING FLUID AND PLUNGER RETRACTED. ABOVE P.O. IS MEANT FOR A/C S/N 0132, BUT ONE WAS CANNED OFF OF A/C S/N 0144. PERMISSION GIVEN TO RETURN THIS UNIT. REPLACED WITH SERVICABLE UNIT. 03/24/2004SDR BAQA093755Mixing Valve · inoperativeTHIS UNIT'S MOTOR RUNS CONSTANTLY. REPLACED WITH SERVICABLE UNIT. 03/29/2004SDR BAQA093957Rod End · excess playEXCESSIVE LATERAL PLAY IN ACTUATOR ROD END. HARDCARD ENCLOSED. REPLACED WITH SERVICABLE UNIT. 03/26/2004SDR BAQA093886Clock · inoperativeLIGHT WAS INSTALLED ON 01/19/2004 AND FAILED 03/15/2004 FOR A TOTAL OF 80.4 FLIGHT HOURS. INTERNAL LIGHTING IS INOPERATIVE. CLOCK WAS PURCHASED OUTRIGHT ON OUR PO 2-022166-05.SDR BAQA091151Blade · will not balanceMAIN ROTOR BLADE WILL NOT BALANCE. REPLACED WITH CANNED UNIT FROM A/C.SDR BAQA091148Blade · will not balanceMAIN ROTOR BLADE WILL NOT BALANCE. INSTALLED CANNED UNITS OFF OF A/C.SDR BAQA090704Control Unit · inoperativeBARO SET KNOB INOPERATIVE. REPLACED WITH SERVICEABLE UNIT. 11/11/03SDR BAQA089546Buss Tie · openBUS TIE OPEN. REPLACED WITH SERVICEABLE UNIT.SDR 2003FA0001040Frame · crackedPART CRACKED AT 90 DEGREES BEND RADIUS FROM APPROX 5 O`CLOCK POS. TO THE 10 O`CLOCK POS. BEFORE IT CRACKED TO THE OUTER SURFACE WHERE IT WAS NOTICED DURING A DAILY INSPECTION. PROBABLE CAUSE MAY HAVE BEEN AN EARLIER GROUND BUMPING INCIDENT THAT CAUSED OTHERSDR BAQA085963Actuator · leakingFENESTRON ACTUATOR LEAKING. BOLT SPINNING IN ARM. BEARINGS WORN. REPLACED WITH SERVICEABLE UNIT.SDR BAQA084707Sensor · intermittentFUEL SENSOR GIVING INTERMITTENT READINGS. ONLY HAVE ONE CORE SO FAR. REPLACED WITH SERVICEABLE UNIT.SDR BAQA084705Signal Cond Unit · inaccurateSIGNAL COND UNIT PRODUCING IRREGULAR READINGS. REPLACED WITH SERVICEABLE UNIT.SDR BAQA084038Radar · inoperativeWEATHER RADAR INOPERATIVE. REPLACED WITH SERVICEABLE UNIT.SDR BAQA084012Brake Disc · warpedBRAKE DISC WARPED. REPLACED WITH SERVICEABLE UNIT.SDR BAQA082909Indicator · malfunctionedATTITUDE INDICATOR FAILED FAR 91-411 CHECK. ALTITUDE OUT OF LIMITS. REPLACED WITH SERVICEABLE UNIT.SDR BAQA081186Amplifier · failedMAST MOMENT INOPERATIVE. REPLACED WITH SERVICEABLE UNIT.
Back to N522ME