N543UW
Service difficulty reports · 149
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N543UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N543UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201708019039Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON FLOORBEAM AT FR 68 AND Y765. REPLACED FLOORBEAM PER SRM 51-72-11.SDR AALA201708019037Mount Bracket · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON FORWARD CARGO UNDER FLOOR ANTENNA MOUNT BRACKET BETWEEN FR 25 AND 26, BETWEEN STRINGERS 43R AND 44R. REPAIRED MOUNT BRACKET PER SRM 51-42-11 AND SRM 51-75-12.SDR AALA201705199013Bottle · low pressureR4 AFT DOOR ASSIST BOTTLE REQUIRES SERVICE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001-A.SDR AALA201704289004Bottle · low pressureAFT RIGHT DOOR ASSIST BOTTLE HAS LOW PRESSURE. SERVICED DOOR ASSIST BOTTLE.SDR AALA201704109037Lens · brokenL4 SEAT MOUNTED EMERGENCY EXIT LIGHT LENS BROKEN. REPLACED THE LIGHT ASSEMBLY.SDR AALA201703289024Plug · leakingAIRCRAFT WAS GROUNDED. FA REPORTED MUSTY ODOR MID CABIN AFT. TURNED OFF PACK 2 AND ODOR SUBSIDED. TURNED PACK 2 BACK ON AND ODOR RETURNED AND CREW TURNED PACK 2 OFF FOR REMAINDER OF FLIGHT. MAINTENANCE FOUND THE APU MAGNETIC DRAIN PLUG LEAKING AND REPLACED ITSDR AALA201703149014Bottle · low pressureR4 DOOR ESCAPE SLIDE BOTTLE PRESSURE WARNING ON CIDS DOOR PAGE. SERVICED THE ASSIST BOTTLE.SDR AALA201702239003Bottle · low pressureL3 DOOR ASSIST BOTTLE LOW. SERVICED THE DOOR ASSIST BOTTLE.SDR AALA201702239004Bottle · low pressureRT DOOR ASSIST DOOR BOTTLE LOW. SERVICED THE ASSIST BOTTLE.SDR AALA201702219013Bottle · low pressureCREW REPORTED R4 DOOR LOW PRESSURE MESSAGE. SERVICED THE DOOR AS REQUIRED.SDR AALA201701289010Bottle · low pressureCHECK R4 DOOR PRESSURE MESSAGE. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA201612319011Transfer Valve · false indicationFUEL ACTUATOR TRANSFER FAULT DURING CRUISE, OK WITH FORWARD SELECTED. MAINTENANCE REPLACED TRANSFER VALVE ACTUATOR IAW AMM 28-28-53.SDR AALA201612089007Bolt · shearedAIRCRAFT WAS GROUNDED, FLIGHT CREW REPORTED THAT THE NR 3 TIRE IS BLOWN AND SEPARATED, SUSPECT NR 3 BRAKE STUCK THAT CAUSED THE BLOW OUT. MAINTENANCE FOUND THE NR 3 WHEEL/TIRE ASSEMBLY BOLT SHEARED, DAMAGED NR 3 BRAKE AND TIRE BLEW. MAINTENANCE REPLACED THE NRSDR AALA201611199009Light · inoperativeEMERGENCY LIGHT ROW 18L INOPERATIVE. R & R SEAT MOUNTED EMERGENCY LIGHT. OPS CHECKED OK IAW AMM 33-51-19-0401.SDR AALA201610139017Fan · malfunctionedAT TOP OF DECENT, MODERATE ELECTRICAL BURNING SMELL IN COCKPIT THRU LANDING EMANATING FROM FWD EYELID AIR VENTS. NO SMELL REPORTED IN CABIN. PARTIAL WORK ACCOMPLISHED. FOUND SOURCE OF ODOR TO BE EXTRACT FAN 18HQ. R&R EXTRACT FAN 18HQ PER AMM 21-26-51. OPSSDR AALA201609119006Floor Panel · damagedAIRCRAFT WAS GROUNDED: AFT GALLEY FLOOR PANEL HAS SOFT SPOT WHEN WALKED ON. R & R AFT GALLEY CENTER FLOOR PANEL IAW 53-42-12 AND 25-28-43.SDR AALA201608309001Floor Panel · damagedAIRCRAFT WAS GROUNDED. FORWARD GALLEY CENTER FLOOR PANEL 221DF HAS 2 LARGE SOFT SPOTS. REPLACED FLOOR PANEL 22DF IAW AMM 53-12-12.SDR AALA201608219006Light · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT AT AISLE SEAT 1C BROKEN. REPLACED WHITE EMERGENCY LIGHT AT 1C AND ACCOMPLISHED A SATISFACTORY OPS CHECK.SDR AALA201607309001Target · dirtyFLIGHT CREW REPORTED RECIEVING AN AFT CARGO DOOR LIGHT DURING TAKE OFF ROLL AND ABORTED THE TAKEOFF AT 75 KNOTS. THE AIRCRAFT RETURNED TO THE GATE WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED THE AFT CARGO DOOR PROXIMITY SWITCH SENSOR, TARGET AND CONNECTOSDR AALA201606119003Lens · missingAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHTS AT SEAT 1A LENS COVER MISSING, R & R EMERGENCY LIGHT AT SEAT 1A AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 33-51-00.SDR AALA201606119002Lens · missingAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHTS AT SEAT 8A LENS COVER MISSING, R & R EMERGENCY LIGHT AT SEAT 8A AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 33-51-00.SDR AALA201605239004Cover · detachedAIRCRAFT WAS NOT GNDED. L1 DOOR EMER EXIT LIGHT COVER FELL OFF. RE-INSTALLED L1 DOOR EMER EXIT LIGHT COVER.SDR AALA201602179010Water Heater · malfunctionedAIRCRAFT WAS GNDED. ODOR DETECTED IN FWD LAVATORY DURING DESCENT THROUGH 10,000. ELEC OR OZONE TYPE SMELL. ACCOMPLISHED JC 26L00021001 TROUBLESHOOT CABIN AIR QUALITY. ISOLATED SOURCE OF ODOR TO FWD LAVATORY WATER HEATER. REPLACED FWD LAVATORY WATER HEATER SDR AALA201601069003Battery · dischargedAIRCRAFT WAS GNDED. EMER EXIT LIGHT BATTERIES DEAD. REPLACED ALL EMER EXIT LIGHT BATTERIES IAW AMM 33-51-38-401.SDR AALA201512029005Battery · dischargedAIRCRAFT WAS NOT GNDED. FLIGHT ATTENDANT FLASHLIGHT BY DOOR 4R NOT OPERATING. REPLACED BATTERY & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201509079007Lens · brokenWHITE EMER LIGHT, AISLE SEAT 6C, LENS BROKEN OFF. REPLACED EMER LIGHT & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201506249007Lens · missingEMERGENCY LIGHT AT SEAT ROW 32 MISSING LENS COVER. R & R EMER LIGHT AT SEAT ROW 32 IAW MM 33-00. OPERATIONS CHECKED NORMAL.SDR AALA201506249006Lens · missingEMERGENCY LIGHT AT SEAT ROW 3 MISSING LENS COVER. R & R EMER LIGHTS AT SEAT ROW 3 IAW MM 33-00. OPERATIONS CHECKED NORMAL.SDR AALA201506249002Lens · missingEMERGENCY LIGHT AT SEAT ROW 1 MISSING LENS COVER. R & R EMER LIGHT AT SEAT ROW 1 IAW MM 33-00. OPERATIONS CHECKED NORMAL.SDR AALA201505049008Lens · missingAISLE EMERGENCY LIGHT LENS IS MISSING AT ROW 9R. R & R LIGHT MODULE AT SEAT ROW 9R.SDR USAA2015040400002Light · looseSEAT 1A EMER EXIT LIGHT HANGING FROM BOTTOM OF SEAT. WIRINGS DETACHED FROM SEAT. REATTACHED EMER EXIT LIGHT ON SEAT 1A. ACCOMPLISHED AN OPERATIONAL CHECK WITH NO DEFECTS NOTED.SDR USAA2014100600007Arming Lever · looseDOOR RR ARM & DISARM LEVER LOOSE. SECURED ARMING LEVER AT DOOR R3 AS REQUIRED.SDR USAA2014092600004Lens · brokenROW 3L EMER LIGHT LENS BROKEN. REPLACED EMER LIGHT LENS IAW AMM 33-51-19.SDR USAA2014081800015Lever · looseR3 ARMING LEVER LOOSE. TORQUED R3 ARMING LEVER.SDR USAA2014012900002Latch · lack of lubeDOOR 1L GIRT BAR LATCH STUCK. LUBED DOOR 1L GIRT BAR LATCH, OPERATIONS CHECKED SATISFACTORY IAW AMM 52-11-00-501-00-820-001A.SDR USAA2013122600011Lens · missingEMERGENCY EXIT LIGHT LENS IN FRONT OF DOOR 4L IS MISSING. REPLACED EMERGENCY EXIT LIGHT LENS IN FRONT OF DOOR 4L.SDR USAA2013111500008Flashlight · inoperativeMAINTENANCE REPORTED THE MID RT F/A FLASHLIGHT INOPERATIVE & SEAL BROKEN. MAINTENANCE R & R MID RT F/A FLASHLIGHT AND SEAL.SDR USAA2013092600005Lens · missingLENS COVER MISSING ON EXIT DOOR 4L EMERGENCY EXIT SIGN. REPLACED LENS COVER ON DOOR 4L EMERGENCY EXIT SIGN.SDR USAA2013092600002Lens · missingEMERGENCY LIGHT AT SEAT 4L MISSING LENS. REPLACED EMERGENCY LIGHT ASSY AT SEAT 4L IAW AMM 33-51-19.SDR USAA2013082700008Floor Panel · delaminatedAFT CARGO COMPARTMENT FLOOR PANEL 151GF DELAMINATED, BEYOND SRM LIMITS 53-02-00 ZONE " B " DAMAGE. REPLACED FLOOR PANEL IAW AMM 53-42-14.SDR USAA2013072300014Cover · missingSEAT 1C EMERGENCY LIGHT COVER MISSING. REPLACED SEAT 1C EMERGENCY LIGHT.SDR USAA2013061700019O-Ring · damagedNOTICED A NOXIOUS ODOR IN CABIN DURING VERY HEAVY RAIN AND HAIL WITH PACKS ON APU BLEED AIR. SMELL WAS THROUGHOUT CABIN AND COCKPIT. ODOR WAS OILY DIRTY SOCK SMELL. TURNED OFF APU BLEED TO PACKS AND ODOR DISSAPATED. R & R O-RINGS ON APU GENERATOR RECEPTACLESDR USAA2013052900007Cover · missingEMERGENCY LIGHT COVER ON SEAT 3-C MISSING. R & R SEAT 3-C EMERGENCY LIGHT IAW AMM 33-51-19.SDR USAA2013042300019Light · damagedSEAT MOUNTED FLOOR EMERGENCY LIGHT DAMAGED AT 6L. REPLACED SEAT MOUNTED FLOOR EMERGENCY LIGHT AT 6L I/A/W AIRBUS MAINTENANCE MANUAL 33-51-18.SDR USAA2013022000001Lens · brokenDOOR 1L EXIT LIGHT COVER BROKE OFF. REMOVED AND REPLACED LIGHT COVER AT DOOR 1L.SDR USAA2012111900026Actuator · low pressureL1 & L2 DOOR EMERGENCY CYLINDER / ACCUMULATOR READ BELOW LIMITS. SERVICED L2 DOOR EMERGENCY ACTUATOR.SDR USAA2012111900025Cylinder · low pressureL1 & L2 DOOR EMERGENCY CYLINDER / ACCUMULATOR READ BELOW LIMITS. SERVICED L1 DOOR EMERGENCY CYLINDER.SDR USAA2012022400003Valve · faultyFLIGHT ATTENDANTS IN MID AND AFT CABIN AS WELL AS PASSENGERS SMELLED RAW GAS ODOR / FUMES JUST AFTER ENGINE SHUT DOWN AT GATE. ALL DOORS WERE CLOSED - APU AND PACKS WERE ON. MAINTENANCE FOUND NR 2 ENGINE FUEL FLOW DIVIDER VALVE BAD. REPLACED VALVE IAW AIRBUSDR USAA2012010600001Fcu · defectiveAT GATE IN CLT, SMOKE (PERCEIVED AS ELECTRICAL) WAS COMING FROM MODE CONTROL PANEL. HAD TO SHUT OFF ALL ELECTRICAL TO GET IT TO STOP. MAINTENANCE REMOVED AND REPLACED THE FLIGHT CONTROL UNIT IAW AIRBUS MAINTENANCE MANUAL 22-81-12-0401.