N549GJ
Service difficulty reports · 19
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N549GJ' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N549GJ' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR N6WA2026101501Warning Message · activatedCABIN ALT MESSAGE. PERFORMED TASK 21-24-18-040-801 IAW MEL 21-24-07 CAT C ON OCN 70104893.SDR N6WA2026100101Engine · vibrationR ENG HIGH VIBE AT 1.8-2.0 MILS - UNSCHED LANDING AT STL, PERFORM HIGH TORQUE PIN INSPECT WITH IN 15FC PER AMM 72-21-02. COMPLIED WITH FAN BLADE SHAKE IAW AMM 72-21-02, NO DEFECTS NOTED. COMPLIED WITH ENG HIBE CHECK. HIGHEST VIBE AT 0.3. IAW AMM 71-00-00-720SDR N6WA2026081701Control Valve · faultedRT THRUST LEVER WILL NOT ADVANCE ABOVE IDLE WITH ENG RUNNING FOR TAKEOFF. REMOVED AND REPLACED T/R DCV IAW AMM 78-32-01 LEAK AND OPS CHECK GOOD. FAULT PERSISTS. REF LOG PAGE 645688 ITEM 2 FOR CORRECTIVE ACTION.SDR N6WA2026081203Control Unit · faultedRUDDER LIMITER CAUTION DURING CLIMB (B1 - 233334, 060059). SWAPPED NR 1 AND NR 2 SSCU. OPS CHECKED GOOD IAW AMM 27-61-05. NO DEFECTS NOTED.SDR N6WA2024090104Spoiler Sys · inoperativeSSCU2 FAULT, AP PITCH TRIM CAUTION, IB FLT SPLRS CAUTION, PITCH FEEL CAUTION, IB GND SPLRS CAUTION, STAB CH 1 INOP, RUD LIMIT FAULT IN FLIGHT. REPLACED SSCU #1 IAW CRJ 550 AMM 27-61-05. OPS CHECKS GOOD.SDR N6WA2024080702Door · false indicationRIGHT EMERGENCY DOOR CAUTION MESSAGE DURING TAXI. OPEN AND RESECURED RIGHT EMERGENCY OVERWING EXIT PER CRJ550 52-21-00. OPS CHECK GOOD.SDR N6WA2024072201Bracket · crackedANGLE BRACKET LOCATED ON AFT SIDE OF FS220.00 STRINGER 13A ON RH SIDE IS CRACKED. REPAIRED RH INTERCOSTAL AT FS220.00 IAW CRJ REO 670-53-11-1979 AND EO C550-53MR-24.SDR N6WA2024071702Floorbeam · corrodedRH SIDE FS280 BEAM IS CORRODED. REMOVED AND REPLACED RH SIDE FS280.00 BEAM IAW CRJ SRM 51-42-00SDR N6WA2024071701Floorbeam · corrodedLH SIDE FS280 BEAM CORRODED. REMOVED AND REPLACED LH SIDE OF FS280 BEAM IAW CRJ SRM 51-42-00.SDR N6WA2024020801Placard · missingSERVICE DOOR LUMINESCENCE STRIP MISSING ON RH SIDE. INSTALLED PHTOTLIMINESENT STRIP BY SERVICE DOOR IAW CRJ 550 AMM 11-30-03.SDR N6WA2023033001Windshield · shortedSMOKE FROM CA WINDSHIELD ELECTRICAL CONNECTORS NEXT TO PEN HOLDER IN FLIGHT AT 8000 FEET SMOKE STOPPED WHEN LH WSHLD HEAT SWITCHED OFF. PERFORMED OPS CHECK OF WINDSHIELD HEAT IAW CRJ 550 AMM 30-41-06. OPS CHECK FAILED. TROUBLESHOT LH WINDSHIELD HEAT IAW CRJ 55SDR N6WA2022052501Door · bindingMAIN PAX DOOR HANDLE JAMMED CLOSED.PERFORMED OPS TEST OF MAIN CABIN DOOR IAW CRJ 550 AMM 52-11-00, OPS TEST GOOD AT THIS TIMESDR N6WA2021090801Retainer · crackedANGLE RETAINER IN R/H MLG WHEEL WELL HAS A CRACK.R&R ANGLE RETAINER IN R/H MLG WHEEL WELL IAW CRJ 700 AMM 53-83-85.SDR N6WA2021090703Bracket · crackedL/H WATER EJECTION BRACKET BETWEEN FS 1144 AND 1162 AT STR 7L IS CRACKED. EJECTION BRACKET BETWEEN FS 1144 AND 1162 AT STR 7L IAW CRJ SRM 51-42-21.SDR N6WA2021090702Intercostal · corrodedINTERCOSTALS BETWEEN FS 349 AND 364, AT STR 27L AND 27R HAS CORROSION. R&R INTERCOSTALS BETWEEN FS 349 AND 364, AT STR 27L AND 27R IAW CRJ 700 SRM 51-42-06SDR N6WA20210908701Attach Angle · corrodedSERVICE DOOR, I/B ANGLE, ATTACH ANGLE CLIPS ARE CORRODED.SDR N6WA2021081602Elt · inoperativeHAND HELD ELT FAILED OPS CHECK.R&R HAND HELD ELT IAW CRJ AMM 25-61-00, OPS CHECK GOOD.SDR N6WA20200708602Warning Message · activatedLT EMERG DOOR CAUTION MSG. DEFERRED L EMERG DOOR CAUTION MSG ON OCN 70069502 PER MEL 52-70-03. CAT C AUTHORIZED BY MXC.SDR N6WA20200708601Warning System · false activationMLG OVERHEAT WARNING MSG. NO SIGNS OF OVERHEAT OR FIRE, DEFERRED MLG OVERHEAT DETECTION SYSTEM ON OCN 70069499 PER MEL 26-14-01B CAT B.