SDR AALA20101009TUL05Pan · crackedLOWER FORWARD CORNER OF WINDOW PAN CRACKED AT STATION 1041 RIGHT SIDE. INSTALLED REPAIR DOUBLER PER AARD 53-10-00-25.Oct 9, 2010 · N558AA · Doug DC982 · Fuselage Main, StructureSDR AALA20101009TUL04Window Frame · crackedCRACK FOUND IN LOWER FORWARD CORNER OF WINDOW FRAME STATION 984 LEFT. INSTALLED DOUBLER PER AARD 53-10-00-25.Oct 9, 2010 · N558AA · Doug DC982 · Fuselage Main, StructureSDR AALA20101009TUL03Window Frame · crackedUPPER FORWARD CORNER OF WINDOW FRAME CRACKED AT STATION 946 RIGHT. INSTALLED DOUBLER PER AARD 53-10-00-25.Oct 9, 2010 · N558AA · Doug DC982 · Fuselage Main, StructureSDR AALA20101009TUL02Pan · crackedUPPER FORWARD CORNER OF WINDOW PAN CRACKED STATION 907 RIGHT SIDE. INSTALLED DOUBLER PER AARD 53-10-00-25.Oct 9, 2010 · N558AA · Doug DC982 · Fuselage Main, StructureSDR AALA20100619LGA01Battery Pack · dischargedFIRST CLASS EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK FOR FIRST CLASS EMERGENCY LIGHT. OPS CHECKED NORMAL.Jun 18, 2010 · N558AA · Doug DC982 · Emergency LightingSDR AALA20091025LGA02Battery Pack · dischargedEMERGENCY LIGHT IN AFT CABIN INOPERATIVE. REPLACED BATTERY PACK.Oct 25, 2009 · N558AA · Doug DC982 · Emergency LightingSDR AALA20091025LGA01Battery Pack · dischargedEMERGENCY LIGHT AT AFT CABIN INOPERATIVE. REPLACED BATTERY PACK AT SEAT 20DEF.Oct 25, 2009 · N558AA · Doug DC982 · Emergency LightingSDR AALA20090513TUL35Longeron · crackedFWD SIDE OF FRAME UNDER LONG 2L IS CRACKED. INSTALLED DOUBLER PER EA MD80-53-006183.May 4, 2009 · N558AA · Doug DC982 · Fuselage Main, FrameSDR AALA200803190Battery Pack · looseLGA - EMERGENCY LIGHT FROM OVERHEAD SEAT ROW 28 TO 30 INOPERATIVE. RESEATED BATTERY PACK BATTERIES AT SEAT ROW 29. SYSTEM GROUND CHECKED NORMAL OPERATION.Dec 27, 2008 · N558AA · Doug DC982 · Emergency LightingSDR AALA20061381Duct · crackedDFW INFLIGHT T465/26DEC TAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINATED DURING CLIMBOUT. LIGHT DID NOT EXTINGUISH WITHIN THE TWO MINUTE TIME LIMIT. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. FOUND DUCT CRACKED. REPLACED WATER SEPARATOR DUCT. SYSTEMDec 26, 2006 · N558AA · Doug DC982 · Humidity Control SystemSDR AALA20061289Gasket · leakingDFW - TAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINATED PASSING FLIGHT LEVEL 220. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. FOUND LEAKS AT LEFT COMPRESSOR OUTLET TO HEAT EXCHANGER AND GASKET ON RIGHT THERMOSTAT. FOUND BOTH OVERHEAT SENSORS COVERED WITHDec 17, 2006 · N558AA · Doug DC982 · Overheat DetectionSDR AALA20060686Light · missingMSP - EMERGENCY LIGHT AT 18D MISSING SHROUDS, LENS AND BULBS. REPLACED BULBS, SHROUD, AND LENS AT SEAT 18D FOR EMERGENCY AISLE LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Sep 12, 2006 · N558AA · Doug DC982 · Emergency LightingSDR AALA20060685Lens · missingMSP - EMERGENCY AISLE LIGHT AT SEAT 9D MISSING SHROUD AND LENS. REPLACED SHROUD AND LENS AT SEAT 9D FOR EMERGENCY AISLE LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Sep 12, 2006 · N558AA · Doug DC982 · Emergency LightingSDR AALA20060687Lens · inoperativeMSP - EMERGENCY AISLE LIGHTS AT SEAT 14D MISSING LENS. REPLACED LENS AT SEAT 14D FOR EMERGENCY AISLE LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Sep 12, 2006 · N558AA · Doug DC982 · Emergency LightingSDR AALA20060014Battery Pack · dislodgedATL - LEFT AND RIGHT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. REPOSITIONED BATTERIES IN BATTERY PACK FOR LEFT AND RIGHT OVERWING EMERGENCY EXIT LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Jan 8, 2006 · N558AA · Doug DC982 · Emergency LightingSDR AALA20040711Charger · inoperativePHX - THREE AFT ACCESSORY CEILING LIGHTS AND TWO SLIDE LIGHTS INOPERATIVE. REPLACED BATTERY PACK AND CHARGER B5-28 IN RIGHT AFT LAV FOR AFT ACCESSORY CEILING LIGHTS AND TWO SLIDE LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Jul 7, 2004 · N558AA · Doug DC982 · Emergency LightingSDR AALA20040622Light · inoperativeDFW - SEAT MOUNTED EMERGENCY LIGHT AT SEAT 12D INOPERATIVE. REPLACED SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY AT SEAT 12D. SYSTEM GROUND CHECKED NORMAL OPERATION.Jun 6, 2004 · N558AA · Doug DC982 · Emergency LightingSDR AALA20030814Pressure Switch · faultySTL - FLT 1677 - STL-PHX - APU SHUT DOWN AT 3000 FT, RETURNED STL AND LANDED WITHOUT INCIDENT. REPLACED OIL FILTER AND OIL PRESSURE SWITCH. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 30, 2003 · N558AA · Doug DC982 · APU Oil SystemSDR AALA20021286Seat Track · corrodedTUL - FOUND CORROSION ON SEAT TRACK FROM STATION 218-351 SEVERAL PLACES THAT ARE OVER MM LIMIT TO BLENDOUT. CORRODED SEAT TRACK WAS REMOVED FROM STATION 218-351 AND REPLACED PER SRM 53-05 FIG 4. (M)Aug 28, 2002 · N558AA · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR AALA20021078Bearing · leakingAFTER SHUTDOWN, NR 2 ENGINE HAD NUMBER 6 BEARING OIL LEAK CAUSING A FIRE. FIRE BOTTLES 1 AND 2 WERE DISCHARGED. NUMBER 2 OIL QUANTITY WAS OBSERVED TO BE 8 QUARTS. REPLACED NUMBER 2 ENGINE. INSTALLED SERVICEABLE NUMBER 1 AND 2 FIRE EXTINGUISHER BOTTLES. SYJul 23, 2002 · N558AA · Doug DC982 · Turbine SectionSDR AALA20020597Battery Pack · dischargedTUL - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS ASSOCIATED WITH BATTERY PACK B5-23 INOPERATIVE. REPLACED B5-23 EMERGENCY EXIT LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)May 2, 2002 · N558AA · Doug DC982 · Emergency LightingSDR AALA20020068Light · inoperativeORD - DURING OVERNIGHT MAINTENANCE EMERGENCY SEAT MOUNTED EXIT LIGHTING FORWARD OF OVERWING EXIT INOPERATIVE. COULD NOT DUPLICATE, SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jan 22, 2002 · N558AA · Doug DC982 · Emergency LightingSDR AALA2000783Shear Tie · corrodedTUL - FOUND CORROSION ON SHEAR TIE AT STATION 1287 BETWEEN LONGERONS L30 AND L29R. REMOVED CORRODED SHEAR TIE AND INSTALLED REPAIR DOUBLER PER SRM 53-03 FIG 3. (M)May 9, 2000 · N558AA · Doug DC982 · Fuselage Main, Structure
Back to N558AA