N572SC
Service difficulty reports not matched to an aircraft · 77
They name N572SC, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N572SC' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N572SC' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 99ZZZM717Battery · dischargedFLT 902 - GYR - LEFT NR 1 AND RT NR 1 DOOR HANDLE EXIT LIGHT ILLUMINATED WHEN ATTENDANTS LIGHT SWITCH IS TURNED ON. LIGHT FAILS TO ILLUMINATE WHEN EMERGENCY LIGHT SWITCH IS TURNED ON FROM COCKPIT. REPLACED EMERGENCY BATTERY OPERATIONAL CHECKS NORMAL. (M)SDR 99ZZZM719Fuse · failedFLT 104 - LAX - ON SERVICE CHECK, FOUND FORWARD CABIN EMERGENCY LIGHTING POWER SUPPLY INOPERATIVE. FOUND BURNED FUSE ON FORWARD CABIN BATTERY PACK CHARGER, REPLACED FUSE. (M)SDR 99ZZZM208Slide · blownFLT 6001 - SFO - L1- DOOR SLIDE INADVERTENTLY INFLATED/DEPLOYED. REPLACED L-1 DOOR SLIDE. (M)SDR 99ZZZX805Engine · malfunctionedDELIVERY FLIGHT, POST-HEAVY MAINTENANCE, A POST-TROUBLE FREE 4 HOUR TEST FLIGHT, NR 3 ENGINE CONSUMPTION 3 QUARTS/HOUR AT 95 PERCENT N1. OIL WAS EXITING ENGINE AT CENTRAL JET PIPE BREATHER. ENGINE WAS REMOVED AND SENT FOR INVESTIGATION. ENGINE CYCLES: 18,22SDR 99ZZZM50Battery Charger · inoperativeFLT 0102 - LAX - MAINTENANCE FOUND RIGHT SIDE EMERGENCY FLOOR LIGHTS IN SECTION 'C' INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHTING BATTERY CHARGER. (M)SDR 99ZZZM49Circuit Breaker · trippedFLT 0102 - LAX - MAINTENANCE FOUND ALL EMERGENCY LIGHTS ARE 'ON' WITH EMERGENCY LEFT SWITCH IN EITHER 'ARM' OR 'ON'. RESET EMERGENCY LIGHT CIRCUIT BREAKER, OPERATIONALLY CHECKS GOOD. (M)SDR 98ZZZX3404Duct · brokenSF/OGG - FLT 0007 - ON DESCENT, FIRE WARNING ON NR 1 ENGINE. THROTTLE TO IDLE WARNING WENT OUT. HIGH PRESSURE BLEED CONTROL T-DUCT FLANGE AND THRUST REVERSER CROSS-OVER DUCT BROKEN AND LEAKING. REPAIRED BOTH DUCTS. OPERATIONAL CHECK WERE NORMAL. (X)SDR 98ZZZM593Slide · failedDURING FAA MINI EVACUATION DEMONSTRATION, THE R3 DOOR SLIDE/RAFT FAILED TO DEPLOY FULLY. THE RAFT PORTION OF THIS TWO PART ASSEMBLY IS THE ONLY PART TO FAIL. THE SLIDE PORTION PERFORMED ITS INTENDED FUNCTION. (M)SDR SCNA98054Slide · failedDURING DEPLOYMENT OF THE R4 DOOR SLIDE FOR TRAINING PURPOSES THE SLIDE FAILED TO INFLATE FULLY.SDR SCNA98041Light · shortedDURING A-LINE CHECK, THE EMERGENCY FLOOR TRACK LIGHTING IN THE AFT MID CABIN AND FORWARD PART OF AFT CABIN WAS FOUND INOPERATIVE. REPAIRED SHORTED WIRING IN TRACK BASE, ALL FLOOR TRACK LIGHTING CHECKS GOOD.SDR SCNA98026Bulkhead Web · crackedDURING SCHEDULED MAINTENANCE, FOUR CRACKS WERE FOUND AT STA 595 LEFT HAND SIDE LONGERON 43 INBOARD OF AREA A REFERENCE NDI MANUAL 531003 FIGURE 1. AREA REPAIRED IN ACCORDNACE WITH DOUGLAS REWORK DRAWING SR105300647001.SDR SCNA98027Coalescer Bag · contaminatedWHILE WARMING THE COCKPIT TEMPERATURE ZONE TWO HAZY FOG POURED IN VENTS THROUGHOUT THE AIRCRAFT. FOUND NUMBER ONE PACK WATER SEPARATOR DIFFERENTIAL PRESSURE INDICATOR POPPED. RESET INDICATOR AND REPLACED WATER SEPARATOR BAG PER MAINTENANCE MANUAL CHAPTER 21SDR SCNA97315Bolt · crackedDURING INSPECTION IN ACCORDANCE WITH AD 96-06-08 AND DC-10 SERVICE BULLETIN 57-126, REV 1, THE BOLT LOCATED IN THE NUMBER 2 POSITION OF THE LEFT WING MILKSTOOL FITTING, (P/N 71658-18-58), WAS FOUND TO HAVE CRACK INDICATIONS. THE BOLT WAS REPLACED WITH (P/N 8SDR SCNA97297Power Supply · inoperativeTHE FORWARD CABIN EMERGENCY FLOOR TRACK LIGHTING WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED FORWARD CABIN POWER SUPPLY, LIGHTS TESTED GOOD.SDR SCNA97271Ovrhd Decoder · failedPASSENGERS SEATED NEAR SEATS 35 HJK NOTED SMOKE COMING FROM OVERHEAD BINS. REMOVED AND REPLACED OVERHEAD DECODER AT THAT LOCATION, FUNCTIONALLY CHECKED READING AND CALL LIGHTS PER DC-10 MM 23-30-00, OPS CHECKED NORMAL.SDR SCNA97246Seat Encoder · failedTHE NUMBER 3 GENERATOR TRIPPED OFF-LINE AND WAS UNABLE REINSTATE USING COM PROCEDURES. SMOKE WAS THEN NOTED IN FORWARD CABIN, AIRCRAFT DIVERTED FOR LANDING. GENERATOR WAS REINSTATED ON APPROACH FOR LANDING. DURING POST FLIGHT INSPECTION, COULD NOT DUPLICATESDR SCNA97142Smoke Detector · failedTHE NUMBER 6 LAVATORY SMOKE DETECTOR WAS FOUND TO GIVE A VERY SLOW ALERT AND NO LAV SMOKE INDICATION WAS RECEIVED IN COCKPIT. REMOVED AND REPLACED LAVATORY SMOKE DETECTOR, DETECTOR OPS CHECKED GOOD.SDR SCNA97113Module Pigtail · brokenFOUND EMERGENCY FLOOR TRACK LIGHTING MODULE AND LIGHT RIPPED AT SEAT ROW 15. DISCOVERED PIGTAIL ON LIGHT MODULE BROKEN AND SECTION OF FLOOR TRACK COVER DAMAGED. REPLACED LIGHT MODULE PIGTAIL AND SECTION OF FLOOR TRACK COVER.SDR SCNA97070Power Supply · inoperativeEMERGENCY LIGHTS IN AFT CABIN CAME ON WITH SWITCH IN THE OFF POSITION. ALSO, FAILED SELF TEST. REMOVED AND REPLACED OVERWING EMERGENCY POWER SUPPLY IN ACCORDANCE WITH MM 33-51-01 AND FUNCTIONALLY TESTED NORMAL.SDR SCNA97069Power Supply · inoperativeEMERGENCY LIGHTS IN MID CABIN CAME ON WITH SWITCH IN OFF POSITION. ALSO, FAILED SELF TEST. REMOVED AND REPLACED MID CABIN EMERGENCY POWER SUPPLY IN ACCORDANCE WITH MM 33-51-01 AND OPS CHECKED NORMAL.SDR SCNA97068Power Supply · inoperativeFOUND OVERWING EMERGENCY EXIT SIGNS INOP DURING LINE CHECK. REMOVED AND REPLACED OVERWING EMERGENCY POWER SUPPLY AND BATTERY PACK IN ACCORDANCE WITH MM 33-50-00 AND FUNCTIONALLY TESTED NORMAL.SDR SCNA97062Ovhd Panel · arcingOVERHEAD PANEL ROWS 25-26 BEGAN ARCING AND FLIGHT ATTENDANT SMELLED SMOKE. INSPECTED OVERHEAD PANELS AT ROWS 25-26 AND ALL COMPONENTS ASSOCIATED WITH PANELS OPERATED FOR SEVERAL HOURS WITH NO DISCREPANCIES NOTED.SDR SCNA97057Light · inoperativeL1 DOOR SLIDE LIGHT WAS FOUND INOP. REMOVED AND REPLACED DOOR SLIDE LIGHT ASSEMBLY AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 25-61-03.SDR SCNA97024Battery Pack · dischargedAFT CABIN EMERGENCY LIGHT BATTERY POWER SUPPLY FAILED EMERGENCY LIGHT TEST. REMOVED AND REPLACED BATTERY PACK AND OPS CHECKED GOOD IN ACCORDANCE WITH 33-51-01.SDR SCNA97022Battery Pack · dischargedFOUND OVERHEAD EMERGENCY LIGHT IN MID CABIN INOP. REMOVED AND REPLACED BATTERY PACK AND OPS CHECKED GOOD.SDR SCNA97012Battery Pack · dischargedFOUND MID CABIN OVERHEAD EMERGENCY LIGHTS INOP OVER BOTH AISLES. REMOVED AND REPLACED MID CABIN EMERGENCY LIGHT BATTERY PACK AND OPS CHECKED IN ACCORDANCE WITH MM 33-51-01 PAGE 201.SDR SCNA96456Scuff Plate · damagedJET BRIDGE CONTACTED AIRCRAFT ON PUSHBACK. INSTALLED TEMPORARY REPAIR ON L2 DOOR SCUFF PLATE. FERRIED TO PHX. REMOVED AND REPLACED L2 FORWARD SCUFF PLATE IN ACCORDANCE WITH MM 53-30-1.SDR SCNA96440Power Supply · inoperativeEMERGENCY LIGHTS CHARGE AND STANDBY CIRCUIT BREAKER POPPED IN FLIGHT. REMOVED AND REPLACED LEFT OVERWING BATTERY CHARGER POWER SUPPLY AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 33-50-11.SDR SCNA96436Battery Pack · dischargedFWD EMERGENCY BATTERY POWER SUPPLY FAILED EMERGENCY LIGHTING SELF TEST. REMOVED AND REPLACED FORWARD POWER SUPPLY BATTERY PACK AND OPS CHECKED GOOD.SDR SCNA96420Power Supply · inoperativeFOUND EMERGENCY LIGHT CHARGE AND STANDBY BREAKERS OPEN. REMOVED AND REPLACED LEFT HAND OVERWING BATTERY POWER SUPPLY AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 33-51-01.SDR SCNA96419Lighting · inoperativeFOUND AFT CABIN TRACK LIGHTING LOOSE AND BROKEN WIRES ON THE RIGHT HAND SIDE. SECURED TRACK, REPAIRED WIRES AND OPS CHECKED IN ACCORDANCE WITH MM 33-50-00.SDR SCNA96418Splice · corrodedDURING HEAVY MAINTENANCE, FOUND LONGERON 52 SPLICE CRACKED AND CORRODED AT BS 890. FABRICATED AND INSTALLED NEW SPLICE IN ACCORDANCE WITH SRM 53-10-00.SDR SCNA96417Stiffener · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION AT FRAME AND SKIN INTERSECTION AT BS 475 FROM LONGERON 44L TO 44R. REMOVED CORROSION, REMOVED AND REPLACED STIFFENER IN ACCORDANCE WITH SRM 51-21-01, 51-31-01 AND 51-35-01.SDR SCNA96398Splice · corrodedDURING HEAVY MAINTENANCE, FOUND LONGERON 46R SPLICE CORRODED BETWEEN FRAMES AT BS 1801 THROUGH BS 1821. REMOVED LONGERON SPLICE, FABRICATED AND INSTALLED A NEW SPLICE IN ACCORDANCE WITH SRM 51-33-01.SDR SCNA96397Seat Track · corrodedDURING HEAVY MAINTENANCE FOUND AFT CARGO PIT LEFT HAND FORWARD OUTBOARD CARGO TRACK HAS EXFOLIATION CORROSION. REMOVED AND REPLACED SEAT TRACK IN ACCORDANCE WITH SRM 51-33-01 AND 53-70-00 FIGURE 2.SDR SCNA96395Shear Tie · corrodedDURING HEAVY MAINTENANCE, FOUND SHEAR TIES LEGS CORRODED AT LONGERON 52, BS 1039. REMOVED CORRODED SHEAR TIES, CLEANED SKIN, FABRICATED AND INSTALLED NEW SHEAR TIES IN ACCORDANCE WITH SRM 53-15-01.SDR SCNA96393Web · crackedDURING HEAVY MAINTENANCE, FOUND THE LOAD BAR TRACK WEB CRACKED AT BS 1780. STOP DRILLED CRACK, FABRICATED AND INSTALLED A DOUBLER IN ACCORDANCE WITH SRM 53-00-01 FIGURE 4 SHEET 2.SDR SCNA96430Skin · cutDURING HEAVY MAINTENANCE, FOUND CUT IN FUSELAGE SKIN AT BS 816, BETWEEN LONGERON 50R AND 51R. CUT OUT DAMAGE, FABRICATED AND INSTALLED DOUBLER AND SKIN FILLER IN ACCORDANCE WITH SRM 53-20-00 FIGURE 13 SHEET 8.SDR SCNA96391Spool Bolt · corrodedDURING HEAVY MAINTENANCE, FOUND CENTER PIT AFT LATCH SPOOL MOUNT HAS CORROSION AT SPOOL MOUNT BOLT INNER SURFACE. REMOVED CORROSION BY OVERSIZING HOLES TO 1.089 DIAMETER. FABRICATED SLEEVE FROM 17-4 AND CADMIUM PLATED IN ACCORDANCE WITH SRM 52-10-00, FIGURE SDR SCNA96427Longeron · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON LONGERON 50 BETWEEN BS 775 AND BS 899. REMOVED CORRODED SECTION OF LONGERON, FABRICATED AND INSTALLED A SPLICED SECTION OF LONGERON IN ACCORDANCE WITH SRM 53-10-00.SDR SCNA96416Intercostal · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON WEBS AND AREA AROUND DOME NUTS THAT ATTACH THE ADF ANTENNA BETWEEN LONGERONS 51R AND 52, BS 1721 TO 1741. REMOVED AND REPLACED INTERCOSTAL IN ACCORDANCE WITH SRM 51-31-01.SDR SCNA96415Longeron · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION AROUND FASTENER HOLES ON LONGERON 52 BETWEEN BS 775 AND 889. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED REPAIR SECTION AND SPLICES IN ACCORDANCE WITH SRM 51-30-00.SDR SCNA96414Frame · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION AROUND NUTPLATE HOLES ON FRAME 1902. REMOVED CORROSION, FABRICATED AND INSTALLED DOUBLERS IN ACCORDANCE WITH SRM 53-00-01 FIGURE 2.SDR SCNA96412Longeron · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION AROUND RIVET HOLES ON LONGERON 50L BETWEEN BS 775 AND BS 850. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED A REPAIR SECTION IN ACCORDANCE WITH SRM 53-10-00.SDR SCNA96411Frame · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON FRAME 1942 BETWEEN LONGERON 51L AND 49R. REMOVED DAMAGED MATERIAL, FABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH SRM 53-00-00 FIGURE 5.SDR SCNA96410Longeron · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION AROUND FASTENER HOLES ON LONGERON 51R FROM BS 775 TO BS 889. FABRICATED AND SPLICED IN NEW LONGERON SECTION IN ACCORDANCE WITH SRM 51-30-01.SDR SCNA96394Wedge · delaminatedDURING HEAVY MAINTENANCE, FOUND RIGHT INBOARD FLAP TRAILING EDGE WEDGE DELAMINATED. REMOVED PREVIOUS REPAIR AND REPLACED WITH A NEW REPAIR IN ACCORDANCE WITH SRM 57-20-00 PARAGRAPH 2 A (1) (5) USING 151 CLOTH AND ADHESIVE 50A.SDR SCNA96429Bulkhead Tee · damagedDURING HEAVY MAINTENANCE, FOUND FORWARD PRESSURE BULKHEAD TEE SUPPORT FOR HINGES WITH TWO LIGHTNING STRIKES. REMOVED TEE, FABRICATED AND INSTALLED A NEW TEE IN ACCORDANCE WITH SRM 51-30-2 AND DRAWING NBA6054. CLOSED AREA AND LEAK CHECKED GOOD.SDR SCNA96426Doubler · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON ANTENNA DOUBLER AT BS 1029 BETWEEN LONGERON 51R AND 52. REMOVED LOWER ANTENNA DOUBLER, FABRICATED AND INSTALLED A NEW DOUBLER IN ACCORDANCE WITH SRM 53-20-00, PAGES 74 TO 84.SDR SCNA96425Support · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION AROUND FLOORBOARD SUPPORT NUT CLIP HOLES IN LOWER GALLEY, BS 735 LBL 8. REMOVED CORROSION, FABRICATED AND INSTALLED REPAIR DOUBLERS IN ACCORDANCE WITH SRM 53-00-01.
Back to N572SC