N583AA
Service difficulty reports · 68
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N583AA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N583AA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20040954Battery · inoperativeSJC - COCKPIT OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY FOR COCKPIT OVERHEAD EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20030519Connector · inoperativeDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT CEILING LIGHTS ABOVE SEATS 23-28 INOPERATIVE. REPAIRED EMERGENCY EXIT CEILING LIGHTS ABOVE SEATS 23-28 CONNECTION. SYSTEM GROND CHECKED NORMAL OPERATION. (M)SDR AALA20030440Wire · inoperativeORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT L1 DOOR INOPERATIVE. REPAIR EMERGENCY EXIT LIGHT WIRE SPLICE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030412Battery · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, CEILING EMERGENCY EXIT LIGHTS FROM ROW 28-29 INOPERATIVE. ADJUSTED EMERGENCY EXIT LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030098Frame · corrodedTUL - FOUND CORROSION IN LOWER CHANNEL AND LIP OF FRAME. BLENDED OUT CORROSION. TREATED AND PRIMED AREA AND INSTALLED DOUBLER PER AARD 53-10-00-14 PAGE NR 1. (M)SDR AALA20030097Structure · corrodedTUL - FOUND CORROSION REMOVAL BEYOND MANUAL LIMITS, CONDITION IV. INSTALLED FULL LENGTH DOUBLER PER AARD 53-10-00-3. (M)SDR AALA20030096Skin · corrodedTUL - FOUND CORROSION ON SKIN AND DOUBLER UNDER LOWER AFT CORNER OF AFT LAV PANEL. REPAIRED PER ESO PO559 DATED 1-10-03. (M)SDR AALA20030095Web · corrodedTUL - FOUND CUSP INBOARD OF SERVICE DOOR FRAME HAS CORROSION. INSTALLED CUSP DOUBLER INBOARD OF SERVICE DOOR AREA APPROX STATION 160-200 PER AARD 53-20. (M)SDR AALA20030094Window Frame · crackedTUL - FOUND LOWER WINDOW FRAME TAB CRACKED, BOTTOM FORWARD CORNER. INSTALLED REPAIR ANGLE ON BOTTOM FORWARD CORNER OF WINDOW FRAME AT STATION 1155 LEFT PER AARD 53-10-00-25. (M)SDR AALA20020837Battery Pack · discharged(BATTERY PACK) DURING OVERNIGHT MAINTENANCE ROW 17-22, EMERGENCY EXIT LIGHTS INOPERATIVE REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20000109Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT CEILING LIGHT BY AFT GALLEY INOPERATIVE. REPLACED EMERGENCY EXIT CEILING LIGHT ASSEMBLY BY AFT GALLEY. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA991052Light · defectiveDFW - DURING OVERNIGHT MAINTENANCE, FORWARD RIGHT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED FORWARD RIGHT OVERWING EMERGENCY EXIT LIGHT MODULE. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA990934Longeron · crackedTUL - EXTERNAL LONGERON CRACKED AT STATINO 1003, LONGERON 26R. REMOVED AND REPLACED WITH EXTERNAL LONGERON FROM STATION 930 TO STATION 1003 PER STANDARD PRACTICES SRM 51-10 (LONGERON 26). (M)SDR AALA990937Skin · gougedTUL - DEEP GOUGE IN FUSELAGE SKIN STATION 1309 LONGERON 19R APPROX 1 INCH LONG. INSTALLED DOUBLER PER SRM 53-04 FIG 3A. (M)SDR AALA990936Seat Track · corrodedTUL - SEAT TRACK NR 2 HAS CORROSION, STATION 1300-1304. REPLACED SEAT TRACK SECTION FROM STATION 126 TO 1304 PER SRM 53-05. (M)SDR AALA990935Seat Track · corrodedTUL - NR 3 SEAT TRACK CORRODED STATION 1300-1304. INSTALLED NEW SEAT TRACK SECTION FROM STATION 1260 TO 1304 PER SRM 53-05. (M)SDR AALA990484Connector · looseDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS IN FORWARD CABIN INOPERATIVE. RESEATED EMERGENCY EXIT FLOOR PATH LIGHT WIRE CONNECTOR IN FORWARD CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA951090Eel Wire · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PASSENGER SEAT ROWS 7 AND 16 FOUND INOPERATIVE. REPAIRED BROKEN EMERGENCY FLOOR LIGHT WIRE BY PASSENGER SEAT, ROW 7. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)