N586SW
Service difficulty reports · 103
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N586SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N586SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HKGA202003198001Unknown · odorPILOT SMELLED SMOKE IN THE COCKPIT AND POSSIBLE FIRE NEAR RH PACK. EMERGENCY DECLARED AND AIRCRAFT LANDING SAFELY. PERFORMED VISUAL INSPECTION OF LH & RH PACK BAYS FOR PACK UNIT OVERHEATING. NO DEFECTS NOTED. INSPECTED AREA OF PACK DUCT PENETRATION INTO CABIN SDR HKGA202001310001Eadi · burned outRH ATTITUDE INDICATOR SCREEN WENT BLANK, THEN CREW NOTED SMOKE ODOR IN COCKPIT. EMERGENCY DECLARED AND AIRCRAFT DIVERTED TO THE NEAREST AIRPORT. REMOVED AND REPLACED RH EADI. OPS CHECK GOOD.SDR HKGA2019101817042Stringer · crackedRH WING #10 STRINGER CRACKED AT STATION YA-2593.REPAIRED STRINGER IAW 57-20-03SDR HKGA2019101804041Stringer · crackedLH WING #10 STRINGER CRACKED AT STATION YA-1359. REPAIRED STRINGER IAW 57-20-03SDR SWIA201439888Striker · failedLEFT MAIN GEAR DID NOT FULLY RETRACT AFTER TAKEOFF. AFTER RAISING FLAPS, GEAR FINISHED RETRACTING AND RED LIGHTS EXTINGUISHED. R & R LT MLG FWD INBD DOOR SEQUENCE VALVE STRIKER. PERFORMED SEVERAL GEAR SWINGS AND FREE FALL AS REQUIRED. ALL LANDING GEAR INDSDR SWIA201439571Connector · damagedEMERGENCY LIGHTS PAST ROW 8 INOPERATIVE. FOUND CONNECTOR PIN PUSHED OUT OF FLOOR TRACK LIGHTING CONNECTOR. REINSERTED PIN, OPS CHECKED GOOD.SDR SWIA201439495Landing Gear · malfunctionedLEFT MAIN GEAR WOULD NOT RETRACT AFTER TAKE OFF. ADJUSTED LT MLG INBD SEQUENCE VALVE ADJUSTING BOLT AND R & R THE LANDING GEAR CONTROL HANDLE. OPERATIONAL CHECKS GOOD.SDR SWIA201439273Fuse · failedLT & RT AFT FUSELAGE EMERGENCY LIGHTS ARE INOPERATIVE. R & R LT & RT AFT FUSELAGE EMERGENCY LIGHT FUSE IAW AMM.SDR SWIA201438583Lamp · inoperativeWHITE EMERGENCY LIGHT AT 2A INOPERATIVE. REPLACED THE LAMP.SDR SWIA201437649Unknown · looseVISIBLE SMOKE IN CABIN AND LAVATORY SMOKE INDICATOR. RAN QRH PROCEDURE AND SMOKE WAS SLOW TO CLEAR. SMOKE CLEARED ON THE GROUND. TIGHTENED LOOSE HARDWARE ON RT PACK.SDR SWIA201437652Unknown · odorSMOKE INDICATION ON MAP. NO AURAL WARNING OR VISUAL INDICATION OF SMOKE. WHEN LT BLEED WAS TURNED OFF THE SLIGHT SMOKE ODOR AND MAP INDICATION CLEARED. RAN THE ENGINES AND BLEEDS, USED BOTH PACKS AND NO INDICATIONS OF SMOKE OR ODOR.SDR SWIA201437566Wire · brokenRED AND WHITE EMERGENCY FLOOR LIGHTS INOPERATIVE. BROKEN WIRE FOUND AT EMERGENCY LIGHT CONNECTOR, WIRE RECONNECTED.SDR SWIA201437108Wire · brokenFLOOR LEVEL EMERGENCY LIGHTING WIRES EXPOSED AT SEAT 2A. REPAIRED BROKEN WIRE AT THE FLOOR LEVEL EMERGENCY LIGHTING.SDR SWIA201436676Switch · out of adjustAT BEGINNING OF TAKEOFF ROLL, ABOUT 70 KTS, DOOR MASTER WARNING FLASHING WITH SERVICE ON OVERHEAD PANEL. REJECTED TAKEOFF PERFORMED. ADJUSTED FUEL SERVICE ACCESS DOOR PANEL SWITCH IAW AMM.SDR SWIA201436142Door Frame · corrodedCORROSION AT THE FWD RIGGING BAY DOOR FUSELAGE FRAME CUT OUT CTR SKIN AREA FRAME CORRODED. C-CHECK REPLACED FWD RIGGING BAY DOOR FUSELAGE FRAME CUT OUT MOLDING IAW SRM PN 120-38322-001.SDR SWIA201335716Fcu · failedRECEIVED CONTROL FAULT WHEN SELECTING FLAPS 25. RAN QRH PROCEDURE, LANDED FLAPS 15. FLT 6359 REPLACED FCU IAW AMM PN 347200-1001, SN ON 0253 & SN OFF 0140.SDR SWIA201335390Light · out of positionWHITE EMERGENCY FLOOR LIGHT DOES NOT ILLUMINATE. FLT 6310 RE-POSITIONED FWD FLOOR LEVEL WHITE EMERGENCY LIGHT. OPERATIONS CHECKED GOOD.SDR SWIA201335234Unknown · odorSTRONG FUEL ODOR IN FLIGHT DECK RUNNING PACKS OFF APU BLEED. NO ODOR WHEN USING ENGINE BLEEDS. FLT 6322 INSPECTED APU FOR FUEL LEAKS, NO EXTERNAL LEAKS NOTED AT THIS TIME. OPERATED APU IAW AMM & SELECTED BOTH PACKS ON USING APU BLEED. NO SMELL OF FUEL OR SSDR SWIA201335114Wire · brokenONE RED LIGHT OUT ON FORWARD FLOOR EMERGENCY LIGHTS. FLT 5398 REPAIRED BROKEN WIRE TO THE FWD EMERGENCY RED FLOOR LIGHT.SDR SWIA201334957Unknown · malfunctionedLT PACK BLOWS HOT AIR ONLY & SMOKES. FLT#6207 REPLACED THE LT PACK TEMPERATURE CONTROL VALVE, LT PACK DUCT TEMPERATURE SENSOR & LT ACM. PN 2204540-4 SN ON 986R SN OFF 17-254; PN 627962-2 PN 979990-1 SN ON 809 SN OFF 2008.SDR SWIA201334394Controller · failedCABIN PRESSURE DESCENDS TO 2000 FEET PER MINUTE AFTER TAKEOFF. FLT#5460 REPLACED PRESSURIZATION CONTROLLER IAW AMM. PN 22201T011400, SN ON 314 & SN OFF 479SDR SWIA201333438Light · inoperativeNR 1 FLOOR LEVEL EMERGENCY LIGHT BURNED OUT. (FLT 5445) RELAMPED EMERGENCY LIGHT.SDR SWIA201333257Cover · detachedFLT 5523, PLASTIC EMERGENCY EXIT SIGN COVER AT 6A DETACHED. REPLACED PLASTIC EMERGENCY EXIT SIGN COVER.SDR SWIA201333239Stringer · crackedLEFT WING CRACKED STRINGER AFT O/B OF NR 2 FUEL ACCESS PANEL. (C-CHECK) REPAIRED STRINGER AFT OF O/B NR 2 FUEL ACCESS PANEL ON LEFT WING IAW SRM.SDR SWIA201333253Seat Track · corrodedLEFT SIDE CABIN FLOOR SEAT TRACK CORRODED ON FWD AND AFT END. (C-CHECK) REPLACED FWD AND AFT END OF LEFT FLOOR SEAT TRACK IAW EST AND AMM.SDR SWIA201333020Inertia Reel · lockedCAPTAINS SEATBELT SHOULDER HARNESS INERTIAL REEL LOCKED. (FLT 6231) RELEASED INERTIAL REEL LOCK AND ADJUSTED CABLE. OPS CHECK GOOD.SDR SWIA201232481Mechanism · lack of lubeF/A REPORTS CABIN DOOR IS DIFFICULT TO OPEN. (FLT 5341) LUBRICATED DOOR OPEN/CLOSE MECHANISM RODS AND JAM ROLLERS.SDR SWIA201232220Light · inoperativeONE WHITE LIGHT ON THE EMERGENCY FLOOR ILLUMINATION LIGHTING IS BURNED OUT. (FLT 5312) RELAMPED EMERGENCY LIGHTING.SDR SWIA201232067Roller · dirtyMAIN CABIN DOOR CANNOT BE OPENED FROM OUTSIDE THE AIRCRAFT. (FLT5654) CLEANED AND LUBRICATED MAIN CABIN DOOR ROLLERS.SDR SWIA201231734Light · inoperativeLAST EMERGENCY LIGHT ON THE FLOOR STRIP IS OUT. (FLT 6294) RELAMPED EMERGENCY LIGHT.SDR SWIA201231523Cover · out of positionMAIN CABIN DOOR VERY HARD TO OPERATE FOR FLIGHT ATTENDANT. (FLT 5368) REPOSTIONED MAIN CABIN DOOR FORWARD HINGE ARM FLOOR COVER ASSEMBLY.SDR SWIA201231522Apu · faultySTRONG CHEMICAL SMELL IN COCKPIT AND CABIN WHEN USING APU BLEED AIR. (FLT 6347) REPLACED APU ASSEMBLY IN REFERENCE TO EMB 120 AMM. P/N: 3800376-2 S/N OFF: P-443SDR SWIA201231412Door · lack of lubeDIFFICULT TO OPEN AND CLOSE MAIN CABIN DOOR. (FLT 5433) LUBRICATED PASSENGER DOOR IN REFERENCE TO AMM.SDR SWIA201231203Light · inoperativeFLOOR EMERGENCY LIGHT STRIP HAD ONE LIGHT OUT. (FLT 6372) RELAMPED NR 3 LIGHT TO EMERGENCY LIGHT STRIP.SDR SWIA201230695Light · inoperativeNR 2 AND NR 4 OVERHEAD EMERGENCY LIGHTS ARE OUT. (FLT 5406) RELAMPED EMERGENCY LIGHTS.SDR SWIA201229718Lamp · burned outFLT 5594, OVERHEAD EMERGENCY LIGHT AT ROW 9 IS OUT. RELAMPED EMERGENCY LIGHT.SDR SWIA201229467Sign · defectiveEXIT SIGN AT ROW 6, SEATS B & C, WILL NOT STAY ATTACHED. (FLT 6266) REPLACED EMERGENCY EXIT SIGN ASSEMBLY AT 6BC. PN: 10-1301-15SDR SWIA201229466Light · disconnectedFLOOR EMERGENCY LIGHT AT ROW 3 IS OUT. (SERVICE) RECONNECTED FLOOR EMERGENCY LIGHT AT ROW 3.SDR SWIA201229306Wire · brokenEMERGENCY FLOOR LIGHT IS OUT. (FLT 5604) REPAIRED BROKEN WIRE ON EMERGENCY FLOOR LIGHT.SDR SWIA201229305Fixture · odorOVERHEAD CABIN LIGHT FIXTURE AT 7C IS GIVING OFF ELECTRICAL SMELL. (SERVICE) REPLACED CABIN LIGHT FIXTURE AT 7C.SDR SWIA201128998Splice · brokenWHITE FLOOR EMERGENCY LIGHT AT ROW 3 IS OUT. (FLT 6445) REPLACED ENVIRONMENTAL SPLICE AT ROW 2 FLOOR LEVEL EMERGENCY LIGHT STRIP.SDR SWIA201128470Wire · damagedFLOOR LEVEL EMERGENCY LIGHT AT 3A IS OUT. (FLT 5650) REPAIRED WIRING TO FLOOR EMERGENCY LIGHTS.SDR SWIA201128183Light · defectiveSMOKE IN THE CABIN ON APPROACH. (FLT 5316) REPLACED THE LIGHT FIXTURE, BALLAST AND LAMP NEAR SEAT 7A.SDR SWIA201128228Battery Pack · dischargedEMERGENCY EXIT SIGN BY RIGHT AFT EXIT & AFT SECTION OF FLOOR EMERGENCY LIGHTS ARE OUT. (SERVICE) REPLACED NR 4 ELBP. P/N D366-04-001, S/N OFF 1238.SDR SWIA201128227Light · inoperative4TH WHITE FLOOR EMERGENCY LIGHT FROM FRONT DOES NOT ILLUMINATE. (FLT 6578) RELAMPED EMERGENCY LIGHT.SDR SWIA201128045Light · inoperativeEMERGENCY FLOOR LIGHT AT 3A IS OUT. (FLT 6289) RELAMPED EMERGENCY LIGHT.SDR SWIA201127485Sign · brokenLEFT SIDE EMERGENCY EXIT LIGHT AT ROW 6 IS BROKEN. (FLT 5362) REPLACED LEFT OVERWING EMERGENCY EXIT SIGN ASSEMBLY AT ROW 6.SDR SWIA201126357Light · missingFLOOR EMERGENCY LIGHT AT ROW 11 IS MISSING. (FLT 6909) REPLACED FLOOR EMERGENCY LIGHT AT ROW 11.SDR SWIA201125794Door · lack of lubeMCD HARD TO OPERATE. (FLT 6354) LUBRICATED CABIN DOOR.SDR SWIA201125448Door · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPEN. (FLT 6947) LUBED DOOR AS NEEDED.
Back to N586SW