N604NK
Service difficulty reports · 78
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N604NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N604NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2025122639223A/C Pack · odorFUME EVENT ON TAKEOFF PACK 1-REF LP-6019368-2, OIL LEAK ON APU GENERATOR FOUND AND COORECTED AND PERFORMED DECONATMINATION OF THE BLEED AIR DUCTS PER PER TSM 05-50-00-810-831. CONTINUED TSM AND PERFORMED DECONTAMINATION OF THE ENVIRONMENTAL CONTROL SYSTEM IAWSDR GTIA2025122239219A/C Pack · odorPILOT REPORTED, JUST BEFORE APPROACH FA CALLED TO REPORT FUMES IN FRONT AND BACK OF CABIN. PERFORMED ODOR IDENTIFICATION IAW TSM 05-50-00-810-831-A. SUSPECT PACK 1 TO BE CAUSE OF ODOR.SDR GTIA2025110339163Unknown · odorDURING DESCENT BELOW 10000FT FAS REPORTED A STRONG DIRTY SOCK SMELL. DESCRIPTION OF ODOR/FUMES: CONTINOUS AND DISCOMFORTABLE, DIRTY SOCKS/ ACRID/ PUNGENT/ IRRITATING/ BURNING EYE SMELL. SOURCE: CABIN AIR SUPPLY VENTS. FWD CABIN AND MID CABIN. NO VISIBLE SMOKESDR GTI2025F00009Unknown · odorDURING DESCENT BELOW 10000FT FAS REPORTED A STRONG DIRTY SOCK SMELL. DESCRIPTION OF ODOR/FUMES: CONTINOUS AND DISCOMFORTABLE, DIRTY SOCKS/ ACRID/ PUNGENT/ IRRITATING/ BURNING EYE SMELL. SOURCE: CABIN AIR SUPPLY VENTS. FWD CABIN AND MID CABIN. NO VISIBLE SMOKESDR GTIA2025090239061Unknown · odorFA REPORTED BAD ODOR FROM AFT LAV ON TAKE OFF & DURING DECENT -PERFORM INSP OF AFT LAV IAW AMM 25-43-00.NO DEFECTS FOUND AT THIS TIME.A/C OK TO RETURN TO SVCSDR GTIA2025060938946Thermocouple · out of limitsENG. ONE EGT OVERLIMIT-FOUND #1 ENG THERMOCOUPLES READING OUT OF LIMITS. REPLACED ALL THERMOUCOUPLES ON #1 ENG PER AMM 77-21-15. OPS CHECK NORMAL. REPLACED #1 ENG LPC BLEED MASTER ACTUATOR PER AMM 75-31-42. OPS & LEAK CHECK NORMAL. THIS CLOSES RIN-17185.SDR GTIA2025060538944Panel · damaged"L1 DOOR DENT FWD LOWER EDGE OF 2.5INCH L X. 187INCH D ALLOWABLE DAMAGE AS PER SRM 52-10-00 PB 101 DIA 106, FIG 109 REPAIR CATEGORY B. HFEC I NSP DUE IN 3000FC AS PER NTM CH 51-10-08 PB 601. (GENERAL WATCH ITEM). RAF 3336560-02 CREATED AND SDR 3336560-02 CREASDR GTIA2025060538943Skin Panel · damagedCRACK INDICATION ON FRAME 16 LH SIDE OPEN FASTENER HOLE H1 AND H2 IN CROSSBEAM SPLICING AREA. H1 LENGTH .136 INCH, H2 LENGTH.146 INCH. PERFORMED PERMANENT REPAIR ON FRAME 16LH SIDE OPEN FASTENER HOLE H1 ON CROSSBEAM SPLICING AREA AT I OCLOCK I.A.W. DWG R5311SDR GTIA2025060538942Skin Panel · damagedLEFT WING - TOP SKIN PANEL 2 - RIB 9-10 UPPER & STRG11, TE OH: RIB 8-9 UPPER/LOWER, RIB 11 & RIB 14 LOWER - CORROSION. RIB 8-9 L 2.577 W 2.463 D .113, RIB 11 L 2.546 W 2.074 D .118, RIB 9-10 L 1.592 W .362 D .028, RIB 14 L 5.010 W 2.363 D .143. PERFORMED PESDR GTIA2025060238937Power Supply · inoperativeDURING BITE TEST OF EMERGENCY POWER SUPPLY UNITS WAS FOUND FAULT EPSU 10WL-REMOVED AND REPLACED EPSU IOWL I.A.W AMM 33-51-38-000-001-A AND AMM 33-51-38-400-001-ASDR GTIA2025060238936Slide · faultyREPLACE SLIDE RAFT PASSENGER CREW DOOR 831 FWD GALLEY ARE I.A.W. TSM 25*-62-000-810-811-A DUE TO INTERNAL LIGHT FAULT -REPLACED SLIDE RAFT PASSENGER CREW DOOR 831 AT FWD GALLEY AREA I.A.W. AMM 25-62-44-400-007.SDR GTIA2025042138860Feeder Cable · damaged"IN FLIGHT AUTO FLIGHT YAW DAMPER 1, RUDDER TRIM 1 FAULT, RUDDER TRV LIM 1 SEE LOG 3437049 & 3437048-REMOVED # 1 ENG PYLON IDG FEEDER CABLE HARNESS & CONNECTOR 400VCI IAW AMM 24-92-00.INSTALLED FEEDER CABLE HARNES & CONNECTOR 400 VCI IAW AMM 24-92-00 OPS CK GSDR GTIA2025041438852Elec Connector · inoperativeIN CRUISE AT FL 340 AUTOPILOT DISCONNECTED AIRCRAFT PITCHED UP AND RIGHT. ECAM ELEC GEN 1 FAULT, AUTO FLT YAW DAMPER 1, RUD TRIM 1 FAULT, RUD TRU CIM 1. FCOM AND EQRH RAN. RESETS SUCCESSFUL. ABOUT 30 MINUTES LATER SAME AXACT ECAMS. ELEC GEN 1 RESET UNSUCCESSFUSDR GTIA2025040738836Unknown · odorFAS REPORT FUME SMELL AT 5,000 ON APPROACH CONFIGURED FLAPS 1. DESCRIPTION OF ODOR/FUMES: PERSISTENT, MOLDY SMELL. APPARENT CABIN SOURCE: UNKNOWN. FWD CABIN, MID CABIN, AFT CABIN, AND FLIGHT DECK. NO VISIBLE SMOKE/HAZE. NO MEDICAL ATTENTION REQUIRED.-PERFORMEDSDR GTIA2025040538834Sensor · faultedON APPROACH WHEN SELECTING FLAPS 2 GOT ECAM F/CTL FLAPS LOCKED WING TIP BRK ON-FOLLOWED TSM 27-51-00-810-819-A. PERFORMD MANUAL RETRACTION OF THE FLAPS IAW AMM 27-50-00-866-012-A AND READOUT OF THE FLAP POSITION PICKOFF UNIT AMM 27-50-00-860-801-A. R/R SFCC-2 SDR GTIA2024101238425Megaphone · no testAFT FA MEGAPHONE INOP-R&R AFT FA MEGAPHONE IAW NKS DRAWING A320 EMER-EQUIP REV. 4. A/C OK FOR SVC.SDR GTIA2024062438194Switch · faultyON TAKEOFF ECAM: HYD Y RSVR LO LVL-AS PER TSM 29-13-00-810-816-A R&R SWITCH LOW LEVEL REF: AMM 29-13-41. OPS CHECK GOOD MESSAGE CLEAREDSDR GTIA2024061438175Actuator · overtempENG #2 OVERTEMP ON TOGA TAKE OFF PACKS OFF TEMP 637C 10 SECONDS-REF TSM 77-00-00-810-818-B STEP 4(F)9, FOUND EGT HARNESS AND JUNCTION BOX CHAFFED. R/R EGT HARNESS AND JUNCTION BOX IAW AMM 77-21-43. SEE LOGPAGE 3340675-2 FOR OPS CHECK.SDR GTIA2023121137675Fan · odorLEVEL OFF FL 350 FUME SMELL IN THE COCKPIT BLOWER FAULT. -R+R AVIONICS FAN BLOWER VALVE IAW AMM 21-26-51. OPS CK GOOD. PERFORMED PACK BURNOUT IAW TSM 05-50-00-810-831-A NO FUMES NOTED DURING TEST. OK FOR SVC.SDR GTIA2022082636615None · crackedCRACK FOUND ON MILLED FRAME AT FR43L STGR 24L TO 18L. RAF-01 2803718-01 OPENED. REF EO 5331-2059.-REPLACED FRAME 43LH (FOOT FRAME) IAW EA 53-0355-22 AND EO 5331-2241 REF AEROMAN NR 2022-391291SDR GTIA2022082636614None · corrodedCORROSION ON BORE OF RH ELEVATOR FITTING #6. RAF 01 2803723-2 GENERATED-REPAIRED RH ELEVATOR HINGE FITTING #6 IAW SRM 55-26-41-300-006, FIRST INSPECTION THRESHOLD IS 6 YEARS AFTER COMPONENT FIRST FLIGHT, SUBSEQUENT INSPECTIONS AT INTERVAL OF 6 YEARS, INSPECTISDR GTIA2022082636613None · corrodedCORROSION ON BORE OF LH ELEVATOR FITTING # 4. RAF 01-2803725-2 GENERATED-REPAIRED LH ELEVATOR HINGE FITTING #4 IAW SRM 55-26-41-300-005 FIRST INSPECTION THRESHOLD IS 6 YEARS AFTER COMPONENT FIRST FLIGHT SUBSEQUENT INSPECTIONS INTERVAL IS 6 YEARS INSPECTION TYSDR GTIA2022082636612None · corrodedCORROSION ON BORE OF LH ELEVATOR FITTING # 1, 2, 3 & 5. RAF 01-2803724-2 GENERATED-REPAIRED LH ELEVATOR HINGE FITTING #1, 2, 3 AND 5 IAW SRM 55-26-41-300-004. FIRTS INSPECTION THRESHOLD IS 6 YEARS AFTER COMPONENT FIRST FLIGHT, SUBSEQUENT INSPECTIONS INTERVAL SDR GTIA2022082636611None · corrodedCORROSION ON BORE OF RH ELEVATOR FITTING #4. RAF-012803724-1 GENERATED-REPAIRED RH ELEVATOR HINGE FITTING #4 IAW SRM 55-26-41-300-005 FIRST INSPECTION THRESHOLD IS 6 YEARS AFTER COMPONENT FIRST FLIGHT, SUBSEQUENT INSPECTIONS INTERVAL IS 6 YEARS. INSPECTION TYSDR GTIA2022082636610None · corrodedCORROSION ON BORE OF LH ELEVATOR FITTING # 6. RAF 01-2803725-1 GENERATED-REPAIRED LH ELEVATOR HINGE FITTING #6 IAW SRM 55-26-41-300-006 FIRST INSPECTION THRESHOLD IS 6 YEARS AFTER COMPONENT FIRST FLIGHT SUBSEQUENT INSPECTIONS INTERVAL IS 6 YEARS INSPECTION TYSDR GTIA2022082636609None · noneLH ELEVATOR INBD & OUTB SERVO CONTROL ACTUATOR BUSHINGS REQUIRE REPLACEMENT-REPAIRED LH ELEVATOR INBD AND OUTBD SERVOCONTROL ACTUATOR FITTING, BUSHINGS REPLACED IAW TI 5513-1602 SRM 55-26-47-300-002 AND CMM 55-21-15-410-801-A01 INSPECTION THRESHOLD IS 6 YEARS SDR GTIA2022082636608None · corrodedCORROSION ON RH ELEVATOR FITTINGS 1, 2, 3 &5. RAF-01 2803723-1 GENERATED-REPAIRED RH ELEVATOR HINGE FITTING #1, 2, 3 AND 5 IAW SRM 55-26-41-300-004 FIRST INSPECTION THRESHOLD IS 6 YEARS AFTER COMPONENT FIRST FLIGHT, SUBSEQUENT INSPECTIONS AT INTERVALS OF 6 YESDR GTIA2022082636607None · damagedRH SPOILER #3 CENTER HINGE FITTING HAS DAMAGED AND MIGRATING BUSHINGS. RAF-01 2803728-1 OPENED-REPAIRED SPOILER #3 CENTER HINGE FITTING IAW EA #57-0376-22 PANT #1 REV. #0 CAT C REPAIR INSPECTION TIME LINE 6 MONTHS ONE TIMESDR GTIA2022082636606None · noneRH ELEVATOR INBD & OUTBD SERVO CONTROL ACTUATOR BUSHINGS REQUIRE REPLACEMENT. RAF-01 2803727-1 GENERATED-REPAIRED RH ELEVATOR INBD AND OUTBD SERVOCONTROL ACTUATOR FITTING, BUSHINGS REPLACED IAW TI 5513-1602 SRM 55-26-47-300-002 AND CMM 55-21-15-410-801-A01 INSDR GTIA2022021436270Megaphone · damagedFWD MEGAPHONE VOLUME KNOB MISING -R/R FWD MEGAPHONE AS REQ'D IAW EMQ DRAWING A320SDR GTIA2021050335705Seal · leaking"FUME EVENT ON APROACH / LANDING F/A IN AFT NOTICED IT FIRST THEN THE COCKPIT. ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )-R & R LH RECIRCULATSDR GTIA2021032935657A/C Pack · odorDIRTY SOCK SMELL ON CLIMB OUT OF EWR TURNED PACK 1 OFF SMELL SUBSIDED ON ARRIVAL INTO FLL AT 8000 SMELL RETURNED TURNED PACK 2 OFF SMELL SUBSIDED-PERFORMED PACK # 1 + # 2 BURN OUT WITH APU + ENG 1+2 IAW TSM 05-50-00 AFTER BURN OUT NO ODOR NOTED AT THIS TIMESDR GTIA2020123135526Unknown · odorFUME EVENT DESCENDING THROUGH 4000 FEET DIRTY SOCKS SMELL. AFT FA REPORTED STRONGEST SMELL COMING FROM ROWS 14 AND BACK. ACCOMPLISHED TSM 05-50-810-831 FOR CABIN ODOR IDENTIFICATION USED AEROTRACER FOUND NO CONTAMINATION OR ODORS PERFORMED ENGINE 1 AND 2 RUNSDR GTIA2019102874739A/C Pack · odorFA REPORTED ATRONG SMELL IN CABIN REAR. ACCOMPLISH COM PROCEDURE W PACK 2 OFF. SMELL DISSIPATED.-PERFORMED TSM 05-50-00-810-831-A. PERFORMED PACK BURN OF #1 AND #2 PACK. FOUND ODOR TO BE TYPE 9. NO ODORS NOTED. NO DEFECTS FOUND.SDR GTIA2019081534553Proximity Sensor · out of limitsLG NOT UPLOCKED, L/G SYS DISAGREE, LG DOORS NOT CLOSED CAUTIONS AFTER GEAR SELECTED UP. AIR RETURN TO DEPARTURE. R & R THE PROXIMITY SENSOR 25GA IAW AMM 32-31-73, FOUND BOTH SENSORS OUT OF LIMITS. ADJUSTED AS REQUIRED IAW AMM 32-31-73 220-078. LGCIU TEST SDR GTIA2019071903491Warning System · activatedENG 1 N2 VIB INDICIATION WENT TO AMBER XX ON TAKEOFF ROLL THEN, ENG VIB SYS FAULT APPEARED ON INITIAL CLIMB CLEARED + REAPPEARED SEVERAL TIMES BEFORE LANDING ( ECAM INDICATIONS (LOWER DISPLAY) N2 VIBRATION )--SDR GTIA2019071703488Unknown · contaminatedFUME EVENT FA REPORTED FUMES IN BACK ON FINAL APPROACH LANDED PERFORMED COM PROCEDURE. FOUND UNKNOWN LIQUID BETWEEN FWD CARGO DOOR PANELS, REMOVED PANELS TO CLEAN SEALS AN DPANELS INSTALLED PANELS PER 53-22-14 R/R RECIRCULATION FILTERS PER AMM 21-21-41. PERFOSDR GTIA2019060303378Unknown · odorFWD F/A REPORTS DIRTY SOCK SMELL DURING APPROACH. AFTER TURNING PACK 1 OFF SMELL SEEMED TO DISSIPATE-PERFORMED OPERATION CHECK OF PACK 1 & 2 IAW AMM 21-63-60. NO DEFECTS FOUND. RUNNING BOTH PACKS FULL HOT/FULL COLD 30 MINSSDR GTIA2019050103316Unknown · odorMUSKY ODOR IN COCKPIT AS WELL AS REPORTED BY, I/A @ AROUND ROW 4, AND 18 ( APU SYSTEM )--SDR GTIA2019050103315Ecs · contaminatedTHROUGH 12,000 FT DIRTY SOCK ODOR PERSISTED UNTIL AFTER LANDING. QRM PROCEDURE WAS COMPLIED WITH TO NO AVAIL PACK 1 OFF OR PACK 2 OFF DID NOT MAKE SMELL GO AWAY-PERFORMED DECONTAMINATION OF THE ECS WITH NR 1 AND NR 2 ENG. IAW AMM 21-00-00. OPS CHECK GOOD. NO OSDR GTIA2019041703288Garlock Seal · leakingODOR IN AFT GALLEY (DIRTY SOCK SMELL). TURNED PACK 2 OFF PER PROCEDURE. ODOR ELIMINATED. PROCEEDED W/O EVENT ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOTSDR GTIA2018092002850Megaphone · brokenDURING RON CHECK, FOUND R2 DOOR FLIGHT ATTENDANT MEGAPHONE BROKEN. R&R OF R2 DOOR FLIGHT ATTENDANT MEGAPHONE IAW EMERGENCY LAYOUT DRAWING.SDR GTIA2018090502831Not Reported · dentedFOUND DENT FR8-9 RT LATERAL STR TO RT SIDE STR. PERFORMED A DOUBLER REPAIR AS PER EO 5311-1854.SDR GTIA2018031502522Unknown · odorSTRONG ODOR DURING ACTIVATION OF THE APU BLEED. TROUBLESHOT IAW TSM 05-50-00-810-831-A. PERFORMED GVI OF APU COMPARTMENT, NO EVIDENCE OF OIL, COULD NOT DUPLICATE. ACFT OK FOR SERVICESDR GTIA2018012802369Flashlight · inoperativeL1 FA FLASHLIGHT INOPERATIVE. R & R THE FLASHLIGHT IAW DRAWING NK320-232-EQ REV4. OPS CHECKED GOOD.SDR GTIA2017091702173Seal · leakingDIRTY SOCK ODOR STARTED AROUND 3000 FT IT WAS VERY FAINT IN THE COCKPIT BUT USED OXYGEN MASKS .THE F/A'S REPORTED A DIRTY SOCK ODOR ON THE GROUND AFTER. ODOR SEEMS WORSE IN CABIN. PERFORMED TSM 05-50-00-810-831A AND R & R NR 1 AND NR 2 ENGINE DEOILER SEALS ISDR GTIA2017052401941Oxygen Mask · unwanted deployPAX OXYEGEN MASK 11 E IS DEPLOYED. REPACKED OXYGEN MASKS AT ROW 11 DEF PER AMM 35-21-43.SDR GTIA2017041401873Oxygen Mask · damagedCAPTAIN`S OXYGEN MASK HOSE TO MASK APPEARS BROKEN, IT LEAKS OXYGEN WHEN HOSE IS MOVED AROUND AND IS NOT SEATED FULLY TO AGAINST THE MASK. R & R THE OBSERVER OXYGNE MASK IAW AMM 35-12-41. LEAK CHECKED GOOD. OPS CHECKED GOOD.SDR GTIA2017040601866A/C Pack · odorRA REPORTED ODOR IN AFT CABIN DURING CLIMB WENT AWAY AFTER 5 MIN. ODOR RETURNED ON DESCENT APPROACH. TURNED OFF PACK 1 ODOR WENT AWAY. PERFORMED PACK 1 BURNOUT IAW AMM 21-00-00-615-002-A.NO NOTED DEFECTS. THIS CLEARS DMI 2177810-1. PLACARD REMOVED.SDR GTIA2017031401829Packing · damagedFUME EVENT DURING FINAL DESCENT AND APPROACH INTO PBI 28R. FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED. PERFORMED A CLEANING OF THE ECS TO PACK NR 2 IAW AMM 21-00-00, NO CONTAMINATION FOUND, LEAK CHECK GOOD, OPS CHECK GOOD. PRECAUTIONARY FOUND
Back to N604NK