N605KW
Service difficulty reports · 16
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N605KW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N605KW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2DYA2023F00319Unknown · unknownFOUND RT FWD O/H EMERGENCY SIGN LIGHT INOP.SDR 2DYA2023605001Light · no testLH AFT EXT EMERGENCY LIGHT DON'T ILLUMINATE DURING TEST. RH FWD OVER WING EMERGENCY LIGHTS DON'T ILLUMINATE DURING TEST.SDR 2023F00075Door · noneAFTER T/O, L FWD ENTRY DOOR EICAS DISPLAYED - DOOR WARNING ALSO ILLUM INTERMITTENTLY. PRESSURIZATION NORMAL. ACCOMPLISHED FIM 52-71 FT 804 & FIM 32-09 FT 803, NO FAULTS NOTED. CLOSED & LATCHED THE L FWD ENTRY DOOR PER AMM 52-11-001/201. ANNUNCIATOR LIGHT SDR 2023F00071Panel · departedON WALKAROUND FOUND ON LEFT ENGINE NACELLE STRUT OUBD ACCESS DOOR 436AL MISSINGSDR 2DYA2022120700494Lamp · inoperativeLOWER HALF FUSELAGE - OUTER EMERGENCY LIGHTS (4EA) ILLUMINATION LAMPS NOT ILLUMINATESDR 2DYA2022120700493Lamp · inoperativeLOWER HALF FUSELAGE - OUTER EMERGENCY LIGHTS (4EA) ILLUMINATION LAMPS NOT ILLUMINATESDR 2DYA2022091900520Door · inoperativeL1 ENTRY DOOR ELECTRICAL FUNCTION INOPSDR 2DYA2022FA0000453Battery Pack · dischargedAFT DOOR EXIT LIGHTS SIGNS WILL NOT ILLUMINATE.SDR 2021FA0000345None · noneCAPTAINS PITOT TUBE P/N S233T912-5. PERFORMED T/S IAW FIM 34-12/822. ADC SYSTEM OK. PERFORMED INSPECTION IAW WITH AMM 34-11-01/601 FOUND CAPT PITOT TUBE CLOGGED. R&R PITOT TUBE IAW AMM 34-11-01. OPS CHECK AND LEAK CHECKS NORMAL. LOG PAGE ITEMS 1.2.3.SDR 2DYA20210907000Flashlight Assy · inoperativeDURING MAINTENANCE IT WAS FOUND THAT THE AFT MID LAV FA STATION EMERGENCY FLASHLIGHT INOP. MAINTENANCE REMOVED AND REPLACED MID FA STATION EMERGENCY FLASHLIGHT ASSY. IAW AMM 25-64-00.SDR 2DYA20210802000Spring · missingDURING WALK AROUND THE MECHANIC FOUND NOSE LANDING GEAR RIGHT HAND SPRING MISSING. PART WAS FOUND AND PROCURED FROM ATLAS. NEW LOCK SPRING (P/N 162T3007-2) WAS INSTALLED PER AMM 32-21-09. OPS CHECK NORMAL AT THIS TIME.SDR 2DYA202108270001Window · crackedAIRCRAFT WAS FLYING FROM KSJT TO KVBG WHEN THE FLIGHT CREW WAS ISEEN CRACK DEVELOPING IN THE R1 FLIGHT DECK WINDOW WHILE IN CRUISE FLIGHT. THE
CAPTAIN ELECTED TO DIVERT INTO KLAX AS A PRECAUTIONARY, THE LANDING WAS UNEVENTFUL.SDR 2DYA20210419000Power Supply · inoperativeDURING SERVICE CHECK THE MECHANIC FOUND FWD GALLEY EMERGENCEY EXIT LIGHTS INOP. THE MECHANIC T/S PER 33-51-11 AND PERFORMED POWER SUPPLY TASK AMM 33-51-07-712-032. TEST WAS UNSATISFACTORY. NEW POWER SUPPLY WAS REQUIRED. MECHANIC R&R POWER SUPPLY UNIT I.A.W. ASDR 2DYA20210109002Battery Pack · failedLIGHT SYTEMS-03 EA BATTERY PACK FAILED TO SUPPLY ENOUGHT ENERGY. MX REMOVED AND REPLACE 03 EA BATTERY PACK ON EMERGENCY LIGHT SYSTEMS IAW B767 AMM 33-57-07 PAGE 204. PERFORMED OPS CHECK GOOD IAW B767 AMM 33-57-07 PAGE 207.SDR 2DYA20210109001Lamp · failedLIGHTS SYSTEM - EXTERNAL LIGHTS (04 EA) LAMPS FAIL TO ILLUMINATE. REMOVED AND REPLACED (04 EA) EMERGENCY EXTERIOR LIGHT LAMPS IAW B767 AMM 33-51-06 PG 201 OPS, CHECK, 600D IAW B767 AMM 33-51-06 PG 202 VERIFIED SATISFACTORY.SDR 2DYA20200206001Battery Pack · failedDURING 28-DAY CHECK THE L/H AFT EMERGENCY LIGHT WAS FOUND INOP. REMOVED AND REPLACED THE L/H AFT BATTERY PACK IAW B767 AMM 33-51-07. PERFORMED OPS CHECK IAW B767 AMM 33-51-07, CHECK NORMAL.
Back to N605KW