N609SK

Service difficulty reports · 373

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N609SK' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWIA202055219Control Rod · corrodedPAX DOOR MID CONTROL RODS HAVE ROD ENDS CORRODED. C-CHECK RO 1/5/2021. REMOVED AND REINSTALLED PUSH ROD ASSEMBLY BETWEEN THE TORQUE ASSEMBLY AND THE MID PIVOT ASSEMBLY WITH NEW ROD ENDS AND HARDWARE, REF CRJ700 AMM 52-11-02-000-818-A01 AND CRJ700 AMM 52-11-0Oct 25, 2020 · N609SK · Cndair CL6002C10 · Passenger/Crew DoorsSDR SWIA202055218Bracket · corrodedPAX DOOR LOWER TORGUE SHAFT STOP BRACKET HAS SIGNS OF CORROSION. C-CHECK RO 1/5/2021. REMOVED AND REPLACED PAX DOOR LOWER TORQUE SHAFT NEW STOP BRACKET AND RESTORED FINISH, REF CRJ700 SRM 51-42-13-001-001-A01 AND CRJ700 SRM 51-21-16-001-001-A01.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Passenger/Crew DoorsSDR SWIA202055217Angle · corrodedFS 280 LT 280 LOWER DOOR FRAME ANGLE ADJACENT TO FLOOR PANEL SUPPORT ANGLE CORRODED LBL 11. C-CHECK RO 1/5/2021. REMOVED AND REPLACED FS 280 LT LOWER DOOR FRAME ANGLE LBL 11, IN REF CRJ700 SRM 51-42-06-001-001-A01 AND CRJ700 SRM 51-42-10-001-001-A01. SEE COOct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, StructureSDR SWIA202055113Door Frame · corrodedAVIONICS BAY DOOR SURROUND STRUCTURE HAS CORROSION FROM FS 349 TO FS 369, STGR 27 AT LT INTERCOASTAL. C-CHECK RO 1/5/2021. INSTALLED NEW LATCH PIN INTERCOSTAL FROM FS 349-FS 364, REF CRJ700 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01 AND DWG SH670-Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, StructureSDR SWIA202055112Door Frame · corrodedAVIONICS BAY DOOR SURROUND STRUCTURE HAS CORROSION FROM FS 349 TO FS 364 AT INTERCOASTAL STGR 26RT. C-CHECK RO 1/5/2021. FOUND PART 100% EXFOLIATED. REMOVED AND REPLACED AVIONICS BAY DOOR SURROUND STRUCTURE FROM FS 349 TO FS 364 AT INTERCOASTAL STGR 26RT (SOct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, StructureSDR SWIA202055111Door Frame · corrodedAVIONICS BAY DOOR SURROUND STRUCTURE HAS CORROSION FROM FS 349 TO FS 364, STGR 27 INTERCOASTAL RT. C-CHECK RO 1/5/2021. INSTALLED NEW LATCH PIN INTERCOSTAL FROM FS 349-FS 364, REF CRJ700 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01 AND DWG SH670-320Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, StructureSDR SWIA202055110Floorbeam · corrodedCORROSION ON LT AND RT FLOORBEAM AT FS 280. C-CHECK RO 1/5/2021. CORROSION ON FS 280.00 LT AND RT FLOOR BEAMS ARE 100% THROUGH AND CORROSION FOUND ON MULTIPLE ELEMENTS THEREFORE FOUND OUT OF LIMITS, IN REF CRJ700 SRM 53-00-00-101-001-A01. REMOVED AND REPLACOct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Floor BeamSDR SWIA202055109Hinge Fitting · corrodedFWD CARGO: FWD DOOR HINGE FITTING HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REMOVED DAMAGE AT FWD CARGO DOOR HINGE FITTING (FWD SIDE), REF CRJ-700 SRM. RECEIVED AND COMPLIED WITH REO. SEE CONTINUATION CARD FOR WORK DETAILS.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage, Door HingeSDR SWIA202055108Intercostal · corrodedGALLEY SERVICE DOOR SURROUND STRUCTURE: INTERCOSTAL AT STGR 20R IS CORRODED BETWEEN FS 319-FS 349, MARKED. C-CHECK RO 1/5/2021. REMOVED AND INSTALLED REPLACEMENT INTERCOSTAL AT STR 20R BETWEEN FS 319-FS 349, REF BOMBARDIER DWG SH670-31950 REV Y, CRJ700 SRM 5Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055107Intercostal · corrodedGALLEY SERVICE DOOR SURROUND STRUCTURE: INTERCOSTAL AT STGR 20R IS CORRODED BETWEEN FS 310-FS 319, MARKED. C-CHECK RO 1/5/2021. INTERCOSTAL AT STR 20R BETWEEN FS 310 TO FS 319 DETERMINED TO BE 100% EXFOLIATED THROUGH. REMOVED CORRODED INTERCOSTAL, REF CRJ70Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055106Striker · corrodedGALLEY SERVICE DOOR SURROUND STRUCTURE: LOWER SEAL STRIKER IS CORRODED AT FASTENER HOLES, MARKED. C-CHECK RO 1/5/2021. REPLACED GALLEY SERVICE DOOR SURROUND STRUCTURE LOWER SEAL STRIKER, REF DWG SH670-31950 REV Y, CRJ700 SRM 51-42-06-001-001-A01, AND CRJ700 Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, StructureSDR SWIA202055105Door Sill · corrodedGALLEY SERVICE DOOR SURROUND STRUCTURE: LOWER MOUNTING ANGLE FOR FLOOR SUPPORT IS CORRODED, MARKED. C-CHECK RO 1/5/2021. REMOVED AND INSTALLED NEW GALLEY SERVICCE DOOR SURROUND STRUCTURE LOWER FLOOR SUPPORT MOUNT ANGLE, REF CRJ 900 SRM 51-42-06-001-001-A01, Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055104Stringer Splice · corrodedSTRINGER SPLICE AT 21R AND FS333 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REPLACED STRINGER SPLICE 21R AT FS 333, REF CRJ700 SRM 51-42-06-001-001-A01 AND DWG SH670-32420 REV E. NO LEAKS NOTED AND COMPLIED WITH TASK CARD 51-900-1002-SKY.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055103Stringer · corrodedSTRINGER 21R BETWEEN FS 310 AND FS 333 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REPLACED STGR 21R FROM FS 310-FS 333, REF CRJ700 SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01 AND DWG SH670-31630 REV K. NO LEAKS NOTED AND COMPLIED WITH TASK CARD 51-9Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055100Stringer · corrodedSTRINGER 19R BETWEEN FS 295 AND FS 310 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REMOVED AND INSTALLED NEW STRINGER 19R FROM FS 295-FS 310, REF CRJ700 SRM. NO LEAKS NOTED AND COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055099Stringer · corrodedSTRINGER 22L BETWEEN FS 295 AND FS 310 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REMOVED AND REPLACED STR 22L FROM FS 280-FS 333, REF CRJ700 SRM AND DWG. NO LEAKS NOTED AND COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055098Stringer · corrodedSTRINGER 19L, BETWEEN FS 280 AND FS 310 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REMOVED AND INSTALLED NEW STR 19L FROM FS 280-FS 310, REF CRJ700 SRM AND DWG, NO LEAKS NOTED AND COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055097Stringer · corrodedSTRINGER 25L HAS CORROSION BETWEEN APPROXIMATELY FS 295 AND FS 319, MARKED. C-CHECK RO 1/5/2021. REMOVED CORROSION ALONG STRINGER 25L FROM FS 319, PER CRJ700 SRM. STRINGER ORIGINAL THICKNESS .063, AREA WITH LOWEST MATERIAL REMAINING .015, DAMAGE REMOVED .04Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055096Stringer Splice · corrodedSTRINGER SPLICE FOR STGR 25R AT FS 333 IS CORRODED, MARKED. C-CHECK RO 1/5/2021. REMOVED AND REPLACED NEW STRINGER SPLICE AT STR 25R AT FS 333, REF CRJ700 SRM AND DWG AND CRJ 700 SRM. NO LEAKS NOTED. COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055095Stringer · corrodedSTRINGER 25R, BETWEEN FS 280 TO FS 295 AND BETWEEN FS 310 TO FS 333 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REMOVED AND REPLACED THE STR 25R FROM FS 280-FS 333, REF CRJ700 SRM AND DWG. NO LEAKS NOTED AND COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055094Stringer · corrodedSTRINGER 26R, BETWEEN FS 280 TO FS 295 IS CORRODED, MARKED. C-CHECK RO 1/5/2021. REMOVED AND REPLACED STR 26R BETWEEN FS 280-FS 295, REF CRJ700 SRM AND REF CRJ700 SRM AND DWG. NO LEAKS NOTED AND COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055093Stringer · corrodedSTRINGER 26L, BETWEEN FS 280 TO FS 295 IS CORRODED, MARKED. C-CHECK RO 1/5/2021. REMOVED AND REPLACED STR 26L BETWEEN FS 280-FS 295, REF CRJ700 SRM AND DWG AND CRJ 700 SRM. NO LEAKS NOTED AND COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055092Doubler · corrodedTCAS OMNIDIRECTIONAL ANTENNA DOUBLER AT STGR 27 IS CORRODED AT THE CONNECTOR HOLE. C-CHECK RO 1/5/2021. INSTALLED NEW TCAS DOUBLER AT STR 27 BETWEEN FS 295 AND FS 310, REF CRJ-700 SRM AND DWG. OPERATIONAL TEST GOOD OF THE TCAS SYSTEM, REF CRJ 700 AMM.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Plate/SkinSDR SWIA202055091Frame · corrodedFRAME FS 295 BETWEEN STGR 24L AND STGR 23R, HAS CORROSION ON THE ATTACH FLANGES. C-CHECK RO 1/5/2021. REMOVED AND REPLACED STR 24L-23R FRAME FS 295, PER REO. NO LEAKS NOTED AND COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, FrameSDR SWIA202055090Door Frame · corrodedFWD WASTE-WATER DOOR SURROUND STRUCTURE IS CORRODED ON THE UPPER INTERIOR SURFACE, MARKED. C-CHECK RO 1/5/2021. REPLACED FWD WASTE WATER DOOR SURROUND STRUCTURE ON THE UPPER INTERIOR SURFACE, REF DWG AND CRJ700 SRM. LEAK CHECK GOOD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, StructureSDR SWIA202055089Door Sill · corrodedPASSENGER DOOR SURROUND STRUCTURE LOWER BACK-UP SILL AT STGR 21L, BETWEEN FS 310 AND FS 319 IS CORRODED. C-CHECK RO 1/5/2021. REMOVED CORRODED STR 21L BACK UP SILL BETWEEN FS 310.00 AND FS 333.00 AND INSTALLED REPLACEMENT BACK UP SILL, REF BOMBARDIER DWG ANDOct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055088Angle · corrodedPASSENGER DOOR SURROUND STRUCTURE: KICK ANGLE IS CORRODED, MARKED. C-CHECK RO 1/5/2021. REMOVED CORROSION FROM PAX DOOR LOWER KICKPLATE ANGLE, REF CRJ-700 SRM. FOUND OUT OF LIMITS, REF CRJ700 SRM. REPLACED PART WITH NEW P/N: SH670-31875-1, REF CRJ-700 SRM Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055087Door Frame · corrodedPASSENGER DOOR SURROUND STRUCTURE: FWD CLOSING FITTING (HANDRAIL CUP?) CORRODED, MARKED. C-CHECK RO 1/5/2021. CORROSION ON PASSENGER DOOR SURROUND STRUCTURE FWD CLOSING FITTING (HANDRAIL CUP?) FOUND OUT OF LIMITS, REF CRJ700 SRM. REPLACED REF CRJ700 SRM ANDOct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, StructureSDR SWIA202055086Angle · corrodedPASSENGER DOOR SURROUND STRUCTURE AFT CAP ANGLE IS CORRODED, MARKED. C-CHECK RO 1/5/2021. REMOVED CORROSION ON PAX DOOR AFT CAP ANGLE, REF CRJ-700 SRM. FOUND OUT OF LIMITS, REF CRJ700 SRM. REPLACED ANGLE WITH NEW P/N: SH670-31821-6, REF CRJ-700 SRM AND BOMOct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055085Angle · corrodedPASSENGER DOOR SURROUND STRUCTURE FWD CAP ANGLE IS CORRODED, MARKED. C-CHECK RO 1/5/2021. REMOVED CORROSION FROM PAX DOOR FWD CAP ANGLE, REF CRJ-700 SRM, FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW P/N: SH670-31851-5, REF CRJ-700 SRM AND DWG.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055084Intercostal · elongatedFS 280-FS 295, LEFT SIDE OUTBOARD INTERCOSTAL HAS AN ELONGATED FASTENER HOLE, MARKED. C-CHECK RO 1/5/2021. REPLACED LT OUTBOARD INTERCOSTAL AT FS 280-295, REF CRJ700 SRM AND DWG. SEE CONTINUATION CARD FOR ADDITIONAL DETAILS. COMPLIED WITH SKYWEST TASK CARDOct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055083Floorbeam · corrodedFLOOR SUPPORT STRUCTURE, CROSSBEAM AT FS 333 BETWEEN LBL 9 AND LBL 27 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REMOVED CORROSION AND EVALUATED, FOUND TO BE OUT OF LIMITS, REF CRJ700 SRM. REMOVED AND PERFORMED REPAIR ON THE FLOOR SUPPORT CROSSBEAM ST FS 3Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Floor BeamSDR SWIA202055082Floor Support · corrodedLEFT FLOOR SILL, FS 280 TO FS 310 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REPLACED FLOOR SILL AT FS 280-FS 310, REF CRJ700 SRM AND DWG. NO LEAKS NOTED AND COMPLIED WITH TASK.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055081Floor Support · corrodedRIGHT FLOOR SILL, BETWEEN FS 280 AND FS 319 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. ORIGINAL THICKNESS IS .050, IAW CRJ700 SRM. CORROSION IS .030 DEEP. REMAINING MATERIAL IS .020. MAX ALLOWED TO REMOVE IS .020, FOUND TO BE OUT OF LIMITS, IAW CRJ700 SROct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055080Frame · corrodedFRAME CORRODED AT FS 333 BETWEEN STGRS 20L/21L. C-CHECK RO 1/5/2021. REPLACED FRAME AT FS 333 STR 18L-21L, REF DWG, REF CRJ 700 SRM AND REF CRJ700 SRM. NO LEAKS NOTED AND COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, FrameSDR SWIA202055079Frame · corrodedFS 333 CORRODED BETWEEN STGRS 26L/26R. C-CHECK RO 1/5/2021. REPLACED STR 21L-21R FROM FS 333, REF CRJ700 SRM AMD DWG SH670-32420 REV E AND REO, NO LEAKS NOTED. COMPLIED WITH TASK CARD. SEE CONTINUATION FOR DETAILS.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, FrameSDR SWIA202055078Stringer · corrodedTOP AND BOTTOM OF STGR 20L CORRODED BETWEEN FS'S 280/295. C-CHECK RO 1/5/2021. REPLACED STR 20L FROM FS 280 TO FS 310, REF REO, NO LEAKS NOTED. COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/StringerSDR SWIA202055077Frame · corrodedFS 319-STGR 20L FRAME CORRODED. C-CHECK RO 1/5/2021. REPLACED FRAME AT FS 319.70 BETWEEN STR 18L AND STR 21L, REF BOMBARDIER DWG, CRJ-700 SRM, NO LEAKS NOTED. COMPLIED WITH TASK CARD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, FrameSDR SWIA202055076Fitting · dentedSERVICE DOOR AFT 2ND FROM BOTTOM FITTING PAD CONTACT AREA DIMPLING, MARKED. C-CHECK RO 1/5/2021. BLENDED SERVICE DOOR AFT 2ND FROM BOTTOM FITTING PAD, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. OPERATIONS CHECKOct 25, 2020 · N609SK · Cndair CL6002C10 · Service DoorsSDR SWIA202055075Fitting · dentedSERVICE DOOR AFT MIDDLE FITTING PAD CONTACT AREA DIMPLING, MARKED. C-CHECK RO 1/5/2021. BLENDED SERVICE DOOR AFT MIDDLE FITTING PAD, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. OPERATIONS CHECKS GOOD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Service DoorsSDR SWIA202055074Fitting · dentedSERVICE DOOR AFT 2ND FROM TOP FITTING PAD CONTACT AREA DIMPLING, MARKED. C-CHECK RO 1/5/2021. BLENDED SERVICE DOOR AFT 2ND FROM TOP FITTING PAD, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. OPERATIONS CHECKS GOODOct 25, 2020 · N609SK · Cndair CL6002C10 · Service DoorsSDR SWIA202055073Fitting · dentedSERVICE DOOR AFT UPPER FITTING PAD CONTACT AREA DIMPLING, MARKED. C-CHECK RO 1/5/2021. BLENDED SERVICE DOOR AFT UPPER FITTING PAD, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. OPERATIONS CHECKS GOOD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Service DoorsSDR SWIA202055072Fitting · dentedSERVICE DOOR FWD BOTTOM FITTING PAD CONTACT AREA DIMPLING, MARKED. C-CHECK RO 1/5/2021. BLENDED SERVICE DOOR FWD BOTTOM FITTING PAD, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. OPERATIONS CHECKS GOOD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Service DoorsSDR SWIA202055071Fitting · dentedSERVICE DOOR FWD MIDDLE FITTING PAD CONTACT AREA DIMPLING, MARKED. C-CHECK RO 1/5/2021. BLENDED SERVICE DOOR FWD MIDDLE FITTING PAD, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. OPERATIONS CHECKS GOOD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Service DoorsSDR SWIA202055070Fitting · dentedSERVICE DOOR FWD 2ND FROM TOP FITTING PAD CONTACT AREA DIMPLING, MARKED. C-CHECK RO 1/5/2021. BLENDED SERVICE DOOR FWD 2ND FROM TOP FITTING PAD, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. OPERATIONS CHECKS GOODOct 25, 2020 · N609SK · Cndair CL6002C10 · Service DoorsSDR SWIA202055069Fitting · dentedSERVICE DOOR FWD UPPER FITTING PAD CONTACT AREA DIMPLING. C-CHECK RO 1/5/2021. BLENDED SERVICE DOOR FWD UPPER FITTING PAD, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. OPERATIONS CHECKS GOOD.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Service DoorsSDR SWIA202055068Angle · corrodedSUSPECTED CORROSION BEHIND RT 280 DRIP TRAY CAP ANGLE AT LOWER COCKPIT DOOR JAM CORNER. C-CHECK RO 1/5/2021. REMOVED AND REPLACED FS 280 RT LOWER WEB SKIN, REF CRJ700 SRM. SEE CONTINUATION CARD FOR WORK PERFORMED. COMPLIED WITH SKYWEST TASK CARD "STRUCTURAOct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055067Angle · corrodedSUSPECTED CORROSION BEHIND LT 280 DRIP TRAY CAP ANGLE AT LOWER COCKPIT DOOR JAM CORNER. C-CHECK RO 1/5/2021. REMOVED AND REPLACED FS 280 LT LOWER WEB SKIN, IN REF CRJ700 SRM. SEE CONTINUATION CARD FOR WORK PERFORMED. ST CARD COMPLETE.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Miscellaneous StructureSDR SWIA202055066Floorbeam · corrodedFS 280 FLOOR PANEL SUPPORT ANGLE CORRODED. C-CHECK RO 1/5/2021. REMOVED AND REPLACED FS 280.00 FLOOR SUPPORT ANGLE, IN REF DWG, CRJ700 SRM. SEE CONTINUATION CARD FOR WORK PERFORMED. ST CARD COMPLETE.Oct 25, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Floor BeamSDR SWIA202055065Stringer · corrodedCORRODED RIVET AND STGR ON STGR 22L BETWEEN FS 953/969. C-CHECK RO 1/5/2021. CORROSION DAMAGE IS LOCATED ON STGR 23L BETWEEN FS 953.00 AND FS 969.00 NOT ON STGR 22L BETWEEN FS 953.00 AND FS 969.00. RIVETS ON STGR 23L BETWEEN FS'S 953/969 REMOVED AND REPLACEOct 24, 2020 · N609SK · Cndair CL6002C10 · Fuselage Main, Longeron/Stringer
Back to N609SK