N61886
Service difficulty reports · 33
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N61886' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N61886' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026100620168Battery Pack · inoperativeTHE EMERGENCY LIGHTS ON ROWS 35-39 INOPERATIVE. REMOVED AND REPLACED LEFT AFT EMERGENCY BATTERY PACK BATTERY PER REF AMM 33-51-06-960-805. OPS CHECK SUCCESSFUL.SDR CALA2026070617562Transceiver · faultedWXR FAIL AND PWS FAIL IN FLIGHT FOUND RADAR XCVR FAILURE DUE TO BLOWER FAN INOP. REMOVED AND REPLACED WX XCVR REF 34-43-41-000-801 / 400-801. ALSO REPLACED WX RADAR R/T MOUNT BLOWER ASSY REF 34-43-51-000-801 / 400-801. WX RADAR XCVR AND BLOWER OPS CKD NORMAL SDR CALA2026063017460Battery Pack · no testEMERGENCY LIGHTS OPS CHECK, MID CABIN EMERGENCY AISLE LIGHTS AND RT FORWARD OVERWING EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK M1676 IAW AMM 33-51-06-960-805. OPS CHKD NORMAL.SDR CALA2026062517321Galley · odorAFT GALLEY COMPARTMENTS HAVE ROTTEN ODOR NEED CLEANING CLEANED & DISINFECTED 426/427 & 428 AFTGALLEY COMPARTMENTS IAW AMM 25-00-00-100-803.SDR CALA2026061517097Battery Pack · inoperativeEMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - LEFT MID M1670 EMERGENCY EXIT LIGHTING BATTERY INOP. REPLACED M1670 EMERGENCY EXIT LIGHTING CONTROLLER BATTERY PACK REF AMM 33-51-06-960-805. OPS CHECK GOOD.SDR CALA2026060816918Stringer · damagedSTRINGER 20L BETWEEN STA 847 AND 867 DAMAGEDREMOVED DAMAGE SECTION OF STRINGER AS PER SRM STRINGER 20L DAMAGED BETWEEN STA 847 AND 867 VERIFIED DAMAGED STRINGER IS REMOVED. MATERIAL ID FOR NEW STRINGER FABRICATED SECTION 146A3204-82. SEE WORK FOR FOR ALL WORKSDR CALA2026060816920Skin · damagedFUSELAGE SKIN DAMAGE AT STR20L- STA847-867. REMOVED DAMAGE TO EVALUTE 11.75 L X 5.125 W REMOVED DAMAGE AREA OF THE FUSELAGE SKIN. RECTANGLE WITH THE SIDES PARALLEL AND PERPENDICULAR TO THE STRINGER SRM 53-00-01-2R-36 REPAIR INSTRUCTIONS 4. (C) ADD EMP:U347143SDR CALA2026010912820Bracket · faultyROW 34ABC EMERGENCY PATHWAY LIGHTING BRACKET BROKEN. REMOVED AND REPLACED EMERGENCY PROXIMITY LIGHTING ASSEMBLY IAW MM 33-51-11.SDR CALA2025121812216Elec Connector · faultedPARKING BREAK LIGHT ILLUMINATES INTERMITENT DURING TAXI WITH BRE AK OFF PERFORMED FIM 32-44 TASK 804 OPS CHECKS GOOD ON PARKING BRAKE AT THIS TIME. CYCLED MLG BRAKES OPS CHECKS GOOD AT THIS TIME. NO DEFECT NOTED. CLEANED PARKING BRAKE ELECTRICAL CONNECTOR PRIOSDR CALA2025100609608A/C Pack · odorSTRONG SMELL AFTER PACK TRANSFER FROM ENG TO APU AFTER LDG IMAGE OF SMOKE/ODOR IN THE PLANE QUESTIONAIRE ACCOMPLISHED TASK 05-51-26-800-801 INITIAL INSPECTION WITH NO FINDINGS. NO FURTHER ACTION REQUIRED AIRCRAFT IS OK FOR SERVICE.SDR CALA2025091208826Lens · missingEMG LIGHT SWITCH COVER STATION 712. INSTALLED EMERGENCY LIGHT ASSEMBLY LENS NEAR AFT LOWER EDGE OF COMPRTMENT #712 COAT CLOSET. EMERGENCY LIGHT FUNCTIONL CHECKS GOOD REF. AMM 33-51-00 / CMM 25-20-23SDR CALA2025081407745Control Panel · faulted2 RTO FOR WINDSHEAR WARN 1ST 50KTS 2ND 30KTS. REMOVED AND REPLACED THE WX RADAR CTRL PANEL REF AMM 34-43-91, OPS CKS NORMAL. REF LP 5885383 FOR THE WXR R/T REPLACEMENT. REMOVED AND REPLACED THE WX RADAR CTRL PANEL REF AMM 34-43-91, OPS CKS NORMAL. REF LP SDR CALA2025060605321Slide · partial deployDOOR 1R EMER SLIDE PARTI ALLY DEPLOYED. DOOR IS CLOSED AND LOCKE D. REINSTALLED ESCAPE SLIDE AND COVER IAW AMM 25-66-01-400-803. ACFT OK TO CONTINUE. VERIFIED PROPER INSTALLATION OF ESCAPE SLIDE AND COVER IAW AMM 25-66-01-400-803 ESCAPE SLIDE PACK INFLATION CYSDR CALA2025052905053Indicator · detachedR1 PLASTIC COVER ON SLIDE INDICATOR DETATCHED ACCOMPLISHED PART 1, APPLIED CLEAR TAPE AND ENSURED GAUGE IS VISABLE. ACCOMPLISH REPETITIVE INSPECTION PRIOR TO EACH FLIGHT PER PART 2 AND ACCOMPLISH A PERMANENT REPAIR PER PART 3 WITHIN 3 CALENDAR DAYS. OKAY TO T SDR CALA2025051404656Lens · brokenEMERGENCY EXIT LIGHT IN FIRST CLASS BROKEN OFF LENS COVER ONLY. APPLY NEF. LIGHT NEF 2510AG TOMC REJECTED. MUST FIX. FWD CLOSET EMERGENCY LIGHT LENS MUST BE PRESENT. ATTACHED PIC SHOWS THE LENS IS MISSING. INSTALLED NEW LENSSDR CALA2025032002988Smoke Detector · no discrepancyLAV D SMOKE DETECTOR GOING OFF SUSPECT ERRONEOUS INTERVIEWED FLIGHT ATTENDENT: HE REPORTED SEEING VAPOR IN LAV AFTER PASSENGER EXIT.INSPECTED SMOKE DETECTOR AND FOUND SECURE. NO ACTIVE FAULT AT THIS TIME.SDR CALA2024111101092Potable Water · unknownPOTABLE WATER SYSTEM NEEDS FLUSHED. FORE AND AFT GALLEY HOT BEVE RAGES HAD CHEMICAL TASTE/SMELL VERIFIED WATER SVC FLUSHED AND FILLED POTABLE WATER SYSTEM. PURGED LINES AT GALLEYS.SDR CALA2024090500567Lamp · faultyDOOR 2L OUTSIDE EGRES LIGHT INOP. RELAMPED DOOR 2L SLIDE LIGHT REF AMM 33-51-04-960-801. OPS CHECK GOOD.SDR CALA2024081502213Battery Pack · no testEMERGENCY LIGHTS BATTERY PACK M2627 FAIL (REF: AAR NR 100013810) REMOVED AND INSTALLED POWER SUPPLY BATTERY PACK M2627 IAW B737 AMM 33-51-06-960-805. TEST OK.SDR CALA2024081502212Battery Pack · no testEMERGENCY LIGHTS BATTERY PACKS M1671 FAIL (REF: AAR NR 100013796) REMOVED AND INSTALLED POWER SUPPLY BATTERY PACK M1671 IAW B737 AMM 33-51-06-960-805. TEST OK.SDR CALA2024081402207Battery Pack · dischargedREPLACE BATTERY PACK M1695 FOR SDR TRACKING PURPOSES ONLY.(REF A AR NR 100013805)REPLACED BATTERY PACK M1695 FOR SDR TRACKING PURPOSES ONLY, WORK ACCOMPLISHED ON W/O:3502189/2000/0008, SER:100013415.SDR CALA2024081402205Battery Pack · dischargedREPLACE BATTERY PACK M1694 FOR SDR TRACKING PURPOSES ONLY.(REF A AR NR 100013806)REPLACED BATERY PACK M1694 FOR SDR TRACKING PURPOSES ONLY, WORK ACCMPLISHED ON W/O:3502189/2000/0008 SER:10013415.SDR CALA2024081402204Battery Pack · dischargedREPLACE BATTERY PACK M1673 FOR SDR TRACKING PURPOSES ONLY.(REF A AR NR 1000138904).REPLACED BATTERY PACK M1673 FOR SDR TRACKING PURPOSES ONLY, WORK ACCOMPLISHED ON W/O:3502189/2000/0008, SER:100013415.SDR CALA2024081600448Battery Pack · dischargedREPLACE BATTERY PACK M1672 FOR SDR TRACKING PURPOSES ONLY (REF AA R NR 100013803) REPLACED BATTERY PACK M1672 FOR SDR TRACKING PURPOSES ONLY, WORK ACCOMPLISHED ON W/O:3502189/2000/0008,SDR CALA2024081502211Battery Pack · no testBATTERY PACKS (M1672, M1673, M1695, M1694) FAILED FUNCTIONAL CHE CK, DOES NOT OPERATE FOR THE MINIMUM OF 15 MINUTES (REF. AAR NR 100013415). R, CREATING SEPERATE LOG PAGES FOR EACH BATTERY P ACKSDR CALA2024081302200Battery Pack · inoperativeEMERGENCY POWER PACK, M2503, FAILS EMERGENCY LIGHTING FUNCTIONAL CHECK, BATTERY DISCHARGES IN LESS THAN 12 MINS (REF. AAR NR 100 013632). REMOVED AND REPLACED BATTERY PACK M2503 IAW B737 AMM 33-51-06.TE ST OK.SDR CALA2024081302199Battery Pack · dischargedEMERGENCY PACK, M1676, FAILS EMERGENCY LIGHTING FUNCTIONAL CHECK , BATTERY DISCHARGES IN LESS THAN 10 MINS (REF. AAR NR 10001363 0).REMOVED AND REPLACED NEW BATTERY PACK EMERGENCY POS M1676 IAW B7 37 AMM 33-51-06-960-806 OPS TEST GOOD. WORK ACCOMPLISHED BY SDR CALA2024060501702Control Panel · faultedBOTH L ENG LOOPS FAULTED UPDATED MAA CODE FIX USING VENDOR MAA SCREEN UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. #1 SYSTEM A FIRE LOOP UPPER AND LOWER FAN FIRE DESDR CALA2024042501240Tire · failedRT INBOARD TIRE BLEW ON TAKEOFF RNR #3 MLG TIRE IN REF AMM 32- 45. ALL SECURE. FUTHER INSPECTION STILL REQUIRED FOR BLOW OUT SEE RELATED LOG PAGES. PARTS USED: 60-3249-9-0002,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1655247 SN OFF 4120 WHEEL, TIRE, SDR CALA2023081102477Battery Pack · dischargedEMERGENCY POWER SUPPLY M2627 INOP. REMOVED AND REPLACED POWER SUPPLY AND BATTERY PACK PER REF AMM 33-51-06. OPS CHECK GOOD.SDR CALA2021090601519Seal · missingPDA 3 AERODYNAMIC SEAL MISSING ON RT TRAILING EDGE FLAP O/B SEE PHOTO. ADDED PHOTO. REQUEST CDL. ADDED PHOTO. ADDED PART #. DISPATCH DESK: 16 NAME: B.B.DATE: 03-SEP-21- TOMC APPROVED. APPLIED CDL. FURTHER DETAILS AWAITEDSDR CALA2017052601582Unknown · odorVERY STRONG SULFUR ODOR DURING LANDING, INSPECTED THE ACFT, NO ODOR PRESENT. INSPECTED BOTH A/C BAYS AND FOUND NO DEFECTS, RAN PACKS THROUGH MULTIPLE TEMP RANGES NO ODORS PRESENT. INSPECTED BOTH PACK INLETS, NO DEFECTS NOTED. INSPECTED BOTH ENGINE INLETS ANDSDR CALA2017040400799Hydraulic System · underservicedDURING DEPARTURE, GEAR UP MASTER CAUTION, HYD AND FLT CONTROL SYS A QTY 75.THEN 78 SLOWLY CAME BACK 72. EMERGENCY DECLARED. SERVICED THE SYSTEM A HYDRAULICS AND OPERATED ALL AFFECTED CONTROLS, ACCOMPLISHED FIM TASK 29-10-00-810-81 3, NO DISCREPENCIES NOTE
Back to N61886