N623AE

Service difficulty reports · 181

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N623AE' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RAIA201801150004Floor Support · corrodedLEFT OMEGA BEAM IS CORRODED UNDER CROSSBEAM BETWEEN FRAMES 58 - 59. REPAIRED THE OMEGA BEAM.Jan 15, 2018 · N623AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201801150003Sidewall Support · corrodedLEFT OMEGA SIDEWALL IS CORRODED BETWEEN FRAMES 58 - 59 ABOVE THE CROSSBEAM. REPAIRED THE OMEGA SIDEWALL.Jan 15, 2018 · N623AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA20180150002Floor Support · corrodedCENTER OMEGA BEAM IS CORRODED UNDER CROSSBEAM BETWEEN FR49 - 50. REPAIRED THE OMEGA BEAM.Jan 15, 2018 · N623AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201801120002Mount · crackedRIGHT ENGINE FWD YOKE LOWER FWD FITTING CRACKED. R & R THE RT ENGINE FWD YOKE LOWER FWD FITTING.Jan 12, 2018 · N623AE · Emb EMB145LR · Engine Mount SectionSDR RAIA2017081430001Acm · seizedLIGHT BURNING SMELL THROUGHOUT CABIN AT 12000' ON DEPARTURE. SMELL DISSIPATED ON APPROACH BACK TO DEPARTURE. UPON FURTHER INSPECTION FOUND NR 2 PACK ACM SEIZED. R & R NR 2 ACM OPS CHECK GOOD.Aug 13, 2017 · N623AE · Emb EMB145LR · Cabin Cooling SystemSDR RAIA201706050001Bulb · inoperativeMAIN DOOR EXTERIOR FLOOD LIGHT NR 1 LOCATED ON BOTTOM OF PLUG DOOR HINGE IS INOPERATIVE. R & R THE BULB, OPS CHECKED GOOD.Jun 5, 2017 · N623AE · Emb EMB145LR · Emergency LightingSDR RAIA201610300002Power Supply · inoperativeSERVICE DOOR EMERGENCY EXIT SIGN IS INOPERATIVE. R & R THE EMERGENCY BATTERY POWER SUPPLY AND OPS CHECKED GOOD.Oct 30, 2016 · N623AE · Emb EMB145LR · Emergency LightingSDR RAIA201610300001Power Supply · inoperativeEMERGENCY EXIT SIGN AT GALLEY WALL IS INOPERATIVE. R & R THE BATTERY POWER SUPPLY AND OPS CHECKED GOOD.Oct 30, 2016 · N623AE · Emb EMB145LR · Emergency LightingSDR RAIA201606150001Light · unknownEMERGENCY LIGHT ABOVE SERVICE DOOR, SERVICE DOOR EMERGENCY EXIT MARKER NR 12 INOPERATIVE. PERFORMED OPS CHECK. OPS CHECK GOOD.Jun 14, 2016 · N623AE · Emb EMB145LR · Emergency LightingSDR RAIA201601120001Bulb · inoperativePASSENGER DOOR EMERGENCY FLOOD LIGHT NR 1 INOPERATIVE. R & R PAX DOOR EMERGENCY FLOOD LIGHT NR 1 BULB. OPS CHECK GOOD.Jan 12, 2016 · N623AE · Emb EMB145LR · Emergency LightingSDR RAIA201511240002Acm · lockedCREW REPORTED SMOKE IN THE CABIN. COMPLIED WITH FIM TASK 21-20-00 FOUND FAULTY NR 2 COOLING TURBINE TO BE THE SOURCE OF SMOKE. DEFERRED PACK NR 2. R & R AIR CYCLE MACHINE. OPS CHECK GOOD.Nov 24, 2015 · N623AE · Emb EMB145LR · Cabin Cooling SystemSDR RAIA201511030002Bulb · inoperativePASSENGER DOOR EMERGENCY FLOOD LIGHT NR 1 IS INOPERATIVE. R & R PAX DOOR EMERGENCY FLOOD LIGHT BULB. OPS CHECK GOOD.Nov 3, 2015 · N623AE · Emb EMB145LR · Emergency LightingSDR RAIA201511030001Bulb · inoperativeSERVICE DOOR EMERGENCY FLOOD LIGHT NR 2 IS INOPERATIVE. R & R SERVICE DOOR EMERGENCY FLOOD LIGHT BULB. OPS CHECK GOOD.Nov 3, 2015 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20150722001Skin · delaminatedTRAILING EDGE DELAMINATION ON UPPER & LOWER SKIN LT INBD FLAP. REPAIRED IAW ERS-EM - 57MR-481.Jul 22, 2015 · N623AE · Emb EMB145LR · Trailing Edge FlapsSDR SIMA20150628005Fitting · corrodedDURING INSPECTION, QA FOUND FRAME 65 SHEAR CLIP CORRODED. ACFT WAS REMOVED FROM SERVICE FOR INSPECTION & WILL BE RETURNED TO SERVICE AFTER INSPECTION. PERFORMED PERMANENT REPAIR TO FRAME 65 SHEAR CLIP IAW SRM 53-31-04 SECTION 4F. REPAIR PART, SHEAR CLIP PN Jun 28, 2015 · N623AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20150628004Skin · damagedWHILE RE-EVALUATING ADL 64 & 16, FOUND 2 DENTS WITH CREASES BETWEEN FRAME 19 - 20, STRINGER 11L - 15L. ACFT WAS REMOVED FROM SERVICE FOR INSPECTION. PERFORMED PERMANENT REPAIR ON 2 DENTS WITH CREASES BETWEEN FRAME 19 - 20 & STRINGER 11L - 15L IAW ERS-EM-53MRJun 28, 2015 · N623AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20150626006Skin · crackedDURING INSPECTION, QA FOUND 2 CRACKS ON RT REAR FUSELAGE I SKIN AT FRAME 75 BELOW STRINGER 2R. ACFT WAS REMOVED FROM SERVICE FOR INSPECTION & WILL BE RETURNED TO SERVICE AFTER INSPECTION. PERFORMED PERMANENT REPAIR ON CRACKS ON RT REAR FUSELAGE I SKIN AT FRAJun 26, 2015 · N623AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20150626005Skin · crackedDURING INSPECTION, QA FOUND 2 CRACKS ON LT REAR FUSELAGE I SKIN AT FRAME 75 ABOVE AND BELOW STRINGER 2L. ACFT WAS REMOVED FROM SERVICE FOR INSPECTION & WILL BE RETURNED TO SERVICE AFTER INSPECTION. PERFORMED PERMANENT REPAIR ON CRACKS ON LT REAR FUSELAGE I SKJun 26, 2015 · N623AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20150622007Fitting · crackedDURING INSPECTION, QA FOUND THE LT WING REAR SIDE BRACE FITTING REINFORCEMENT BETWEEN RIB 3 & RIB 4 TO BE CRACKED ON THE OTBD SIDE OF RIB 3. AIRCRAFT WAS REMOVED FROM SERVICE FOR INSPECTION & WILL BE RETURNED TO SERVICE AFTER INSPECTION. R & R THE LT WING REJun 22, 2015 · N623AE · Emb EMB145LR · Wing Miscellaneous StructureSDR SIMA20150621006Frame · corrodedDURING INSPECTION, QA FOUND CORROSION ON FRAME 65 AROUND TWO NUTPLATE HOLES ABOVE LT FLOOR SUPPORT. ACFT WAS REMOVED FROM SERVICE FOR INSPECTION & WILL BE RETURNED TO SERVICE AFTER INSPECTION. PERFORMED PERMANENT REPAIR TO CORRODED NUTPLATE HOLES ON FRAME 65Jun 21, 2015 · N623AE · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20150604014Angle · crackedLEFT FLOORBEAM INBD & OTBD ANGLES ARE CRACKED & BROKEN BELOW GUSSET. INSTALLED NEW SERVICEABLE LT FLOORBEAM INBD AND OTBD ANGLES BELOW GUSSET IAW SRM 51-40-02 & SRM 51-20-01.Jun 4, 2015 · N623AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20150604015Connector · brokenRIGHT OVERWING EMER LIGHT CONNECTOR P8562 BROKEN. R & R ADAPTER PART OF CONNECTOR ON RT OVERWING EMER LIGHT CONNECTOR P8562 IAW SWPM 20-50-01. OPERATIONS CHECKED GOOD. SEE TURNOVER FOR DETAILS.Jun 4, 2015 · N623AE · Emb EMB145LR · Light System WiringSDR SIMA20150604013Skin · crackedLEFT UPPER FUSELAGE SKIN CRACKED JUST AFT OF FRAME 75 & ABOVE STRINGER 2L. CRACK IS APPROX 1/2 INCH IN LENGTH. FREQ=400KHZ, V-GAIN=77.0, H-GAIN=64.0, LPF=100, 100-500 KHZ PROBE. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-1420. SEE TURNOVER FOR DETAILS.Jun 4, 2015 · N623AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20150604012Connector · brokenBROKEN ELEC CONNECTOR ON LT EMER LIGHT ON ACFT UNDER FWD FUSELAGE FAIRING. R & R ELEC CONNECTOR FOR LT EMER LIGHT ON ACFT UNDER FWD FUSELAGE FAIRING P08561 IAW SWPM 20-50-01.Jun 4, 2015 · N623AE · Emb EMB145LR · Light System WiringSDR SIMA20150604011Angle · crackedCENTER FLOORBEAM LT ANGLE IS CRACKED BELOW GUSSET. R & R CTR FLOORBEAM LT ANGLE BELOW GUSSET IAW SRM 51-40-02. SEE TURNOVER FOR DETAILS.Jun 4, 2015 · N623AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20150604010Frame · corrodedFRAME 65 HAS CORROSION AROUND NUTPLATE HOLES AT CARGO DOOR GUIDE PLATE. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-1396. SEE TASK & WIP ENTRIES FOR DETAILS.Jun 4, 2015 · N623AE · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20150604009Power Supply · inoperativeTHE FWD OVERWING EMER LIGHT ON THE RT WING DOES NOT ILLUMINATE. R & R BATTERY POWER SUPPLY & BATTERY POWERING THE FWD OVERWING EMER LIGHT ON THE RT WING IAW AMM 33-50-04 & WC 33-700-19. EMER LIGHT OPERATIONS CHECKED GOOD.Jun 4, 2015 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20150604008Skin · crackedRIGHT UPPER FUSELAGE SKIN CRACKED ON FRAME 75 AT FIRST & SECOND FASTENERS BELOW STRINGER 2R. CRACK IS APPROX 1/4 INCH IN LENGTH. FREQ=400KHZ, V-GAIN=77.0, H-GAIN=64.0, LPF=100, 100-500 KHZ PROBE. PERFORMED REPAIR ON RT FUSELAGE SKIN CRACK AT FRAME 75, STRINJun 4, 2015 · N623AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20150510004Contact · defectiveCEILING EMER LIGHT EXIT SIGN AT FWD OVERWING AISLE POSITION INOPERATIVE. REPLACED CONTACT AT SPLICE SP9209 IAW SWPM 20-50-01. EMER LIGHT OPERATIONS CHECKED GOOD IAW AMM 33-50-00.May 10, 2015 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20150510003Light · inoperativeEMERGENCY EXIT LIGHT ABOVE SERVICE DOOR INOPERATIVE. R & R EMER EXIT SIGN LIGHT ABOVE SERVICE DOOR IAW AMM 33-50-14. OPERATIONS CHECKED GOOD.May 10, 2015 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20150205006Connector · inoperativeWHILE PERFORMING PS 2 INSPECTION FOUND EMERGENCY LIGHT NR 8, AFT CABIN INOPERATIVE. REPLACED THE ELECTRICAL CONNECTORS IAW SWPM-2430-20-50-00. OPS CHECKED GOOD IAW AMM 33-50-00.Feb 5, 2015 · N623AE · Emb EMB145LR · Light System WiringSDR SIMA20141202001Holder · brokenFLIGHT ATTENDANT'S FLASHLIGHT HOLDER BROKEN, WILL NOT HOLD FLASHLIGHT. R & R FWD FLIGHT ATTENDANT FLASHLIGHT ASSEMBLY IAW AMM 33-50-16.Dec 2, 2014 · N623AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20140514007Nut Plate · brokenLEFT FWD EXTERNAL EMERGENCY LIGHT ASSEMBLY HAS BROKEN NUTPLATES. R & R LT FWD EXTERNAL EMERGENCY LIGHT ASSEMBLY IAW AMM 33-50-10, OPERATIONS CHECKED GOOD.May 14, 2014 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20140514008Battery · dischargedLEFT FWD WING EXT EMERGENCY LIGHT INOPERATIVE. AFTER T/S R & R NR 1 EMERGENCY LIGHT CHARGER & BATTERY IAW WC 33-700-19. OPERATIONS CHECKED GOOD IAW WC 33-700-17.May 14, 2014 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20140506006Battery · dischargedNR 2 EMERGENCY BATTERY REPLACED DUE TO CONNECTED EMERGENCY LIGHTING INOPERATIVE.May 6, 2014 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20140506005Battery · dischargedNR 2 EMERGENCY BATTERY REPLACED DUE TO CONNECTED EMERGENCY LIGHTING INOPERATIVE.May 6, 2014 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20140316002Connector · unsecureEMERGENCY LIGHT INOPERATIVE AT GALLEY CABIN PARTITION WALL. SECURED ELEC CONNECTOR FOR EXIT IDENTIFIER SIGN AT GALLEY, CABIN PARTITION IAW AMM 33-50-13 STEP I 3 B. OPERATIONS CHECKED GOOD.Mar 16, 2014 · N623AE · Emb EMB145LR · Light System WiringSDR SIMA20140119004Seal · damagedFIRST OFFICER FOUND SMOKE COMING FROM THE NR 1 ENG TAIL PIPE, SHUTDOWN FOR MORE THAN 5 MINUTES. R & R AGB BREATHER SEAL & LPT SHAFT PLUG WITHIN 50 FHS.Jan 19, 2014 · N623AE · Emb EMB145LR · Turbine Engine Oil SystemSDR SIMA20131127001Light · inoperativeOVERHEAD EMERGENCY LIGHT AT SEAT 3BC INOPERATIVE. R & R THE AISLE EMERGENCY LIGHT BULB AT SEAT ROW 3 IAW EMB-145 AMM 33-50-08. OPERATIONS TESTED GOOD. USED A BULB FROM THE SPARE BULB KIT.Nov 27, 2013 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20131111001Fadec · malfunctionedCREW REPORTED DURING CLIMB ABOVE FL270, NR 1 ENGINE ROLLED BACK TWICE LOSING 10 PERCENT N1, WOULD NOT ACCELERATE AT CRUISE ALTITUDE. THRUST WAS IN DETENT AND AT FULL POWER, THRUST LEVERS WERE NOT LOOSE, CRUISE ALT FL 370. ALL ENGINE INDICATIONS REMAINED INNov 11, 2013 · N623AE · Emb EMB145LR · Fuel Controlling SystemSDR SIMA20131019002Light · inoperativeRIGHT OVER WING EMERGENCY LIGHT IS INOPERATIVE. R & R RIGHT OVER WING EMERGENCY LIGHT IAW AMM33-50-07. OPS CHECK IS GOOD.Oct 19, 2013 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20131008003Light · wrong partLEFT NR 8 EMERGENCY LIGHT STRIP, WRONG PN INSTALLED. R & R LT NR 8 EMERGENCY LIGHT STRIP IAW AMM 33-50-1.Oct 8, 2013 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20131005006Channel · gougedCARGO CENTER BEAM DAMAGED AROUND NUTPLATE HOLE FWD OF FR 73. REPAIRED CARGO CENTER BEAM AROUND NUTPLATE HOLE FWD OF FR 73 IAW EO EM-53MR-2214.Oct 5, 2013 · N623AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20131003013Frame · damagedFRAME 65 DENTED AND GOUGED BETWEEN S12-13R. REPAIRED IAW EO-EM-53MR-2212.Oct 3, 2013 · N623AE · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20131003012Skin · corrodedINNER FUSELAGE SKIN CORRODED BETWEEN FRAMES 9-10 AND S20-21L. REPAIRED IAW EO-EM-53MR-2211.Oct 3, 2013 · N623AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20131003011Frame · gougedFR 65 GOUGED BETWEEN STR 12R/13R JUST BELOW STR 12R. PERFORMED REPAIR IAW EO-EM-53MR-2213.Oct 3, 2013 · N623AE · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20130920011Mount · crackedCRACK ON LT FWD LOWER, FWD ENGINE YOKE INBD SIDE UPPER OTBD RADIUS. PERFORMED REPAIR IAW AEA EO EM-54MR-386.Sep 20, 2013 · N623AE · Emb EMB145LR · Engine Mount SectionSDR SIMA20130910010Flashlight Assy · inoperativeCO-PILOTS EMERGENCY FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT ASSY IAW AMM 33-50-16. OPS TESTED GOOD.Sep 10, 2013 · N623AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20130910013Light · wrong partNR 8 EMERGENCY LIGHT STRIP INCORRECT PN INSTALLED. R & R NR 8 EMERGENCY LIGHT STRIP IAW EMB 145, AMM 33-50-12. OPS CHECK GOOD.Sep 10, 2013 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20130910011Wire · brokenLT NR 4 EMERGENCY LIGHT HAS A BROKEN WIRE. REPAIRED BROKEN WIRE ON LT NR 4 EMERGENCY LIGHT STRIP HARNESS, AIRCRAFT SIDE IAW SWPM 20-21-00. BOW139255 FOR OPS CHECK, TURN OVER FOR DETAILS.Sep 10, 2013 · N623AE · Emb EMB145LR · Light System Wiring
Back to N623AE