N626NK
Service difficulty reports · 41
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N626NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N626NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2026041339352Megaphone · inoperativeFWD MEGAPHONE INOP .-R & R FWD MEGA PHONE REF AMM 25-65-51. NO DEFECTS NOTED.SDR GTIA2026030939291A/C Pack · odorCLIMBING THROUGH FL 250 FA REPORTED SOUR SMELL PACK 2 WAS ISOLATED AND THE SMELL DISSAPATED AIR QUALITY REPORTING FORM COMPLETED -FOLLOWING TSM 05-50-00-810-831-A PERFORMED LEVEL A DECONTAMINATION OF THE ECS IAW AMM 21-00-00-615-802-A. USING BOTH APU BLEED & ESDR GTIA2026022339284A/C Pack · odorFUME EVENT PACK 1 ON ARRIVAL INTO MCO APPX 26,000-REF TSM 05-50-00-810-831-A THE IDENTIFIED SOURCE OF THE FUME/ODOR BASED ON AIR QUALITY REPORT & DECISION TABLE WAS TYPE 8; AIRCRAFT WAS DEICED PRIOR TO DEPARTURE @ CMH TO MCO. REF L.P. 6032908-2 FOR LEVEL A DECSDR GTIA2025010539237Megaphone · no testL1 BULLHORN WILL NOT TEST-REMOVED AND REPLACED L1 MEGAPHONE IAW AMM 25-65-51 OPS CHECK GOOD MOC 120719SDR GTIA2025112439188Flashlight · inoperativeL1 INBOARD F/A FLASHLIGHT WITH RED LIGHT ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-R/R ZONE B FWD F/A STATION I/B FLASHLIGHT ASSY PER SPIRIT AIRLINES DRAWING NO A320 EMER EQUIP REV 7 THIS CLEARS DMI # 3432186-1 PLACARD REMOVED MOC NOTIFIED DMI LOG UPDASDR GTIA2025111739180Epsu · inoperativeBATTERY FAULT EPSU 10WL, 11WL. 12WL AND 13WL. -REMOVED AND REPLACED BATTERY EPSU 10WL, 12WL, AND 13WL IAW AMM 33-51-38-000-002-A AND AMM 33-51-38-400-002-A"SDR GTIA2025063038972Battery Pack · faultedEPSU BATTERY 10WL FAILED EPSU SYS TEST-R&R'D EPSU BATTERY AT 10WL PER AMM 33-51-38. ALL CHECKS GOOD.SDR GTIA2025030438777A/C Pack · odorFUME EVENT DURING CLIMB REPORTED BY ALL FA IN CABIN ISOLATED PACK 2 AND CONTINUE FLIGHT-CW AQE TROUBLESHOOTING IAW TSM 05-50-00 FOUND THE SOURCE OF THE AQE COMING FROM PACK 2. REF LP 3605715-2 FOR PACK 2 MEL A/C OK FOR SERVICE MOC 106411. DESCRIPTION OF FUMESSDR GTIA2025022738766Ecs · contaminatedAFT F/A REPORTED " DIRTY RAG" "MUSTY" SMELL AT APROX 2000.-C/W TSM 05-50-00-810-831-A AND TI 2100-2002-CEO PERFORMED DECONTAMINATION OF ECS IAW AMM 21-00-00. R+R RECIRC FILTERS IAW AMM 21-21-41. NO SMELL NOTED.SDR GTIA2025022438760Unknown · odorSTRONG ODOR ON DESCENT STARTING AROUND 25,000 UNPLEASANT MUST GYM SOCK SMELL-PERFORMED TSM 05-50-00-810-831A. INSPECTED PACK# 2 FOR CONTAMINATION. NO EVIDENCE OF CONTAMINATION FOUND. RAN BOTH ENGINES TO DUPLICATE FAULT IAW AMM 71-00-00. NO ODOR DETECTED. R&R RSDR GTIA2025020638720Slide · warning messageFOUND R1 DOOR SLIDE FAULTING EPSU TEST-R/R R1 DOOR SLIDE IAW AMM 25-62-44 OPS CHECK GOODSDR GTIA2025013038707Unknown · odorFA "B" AT THE L2 DOOR JUMP SEAT REPORTED DIRTY SOCKS SMELL DURING FINAL APPROACH-APPLIED TSM 05-50-00 NO ABNORMAL SMELL NOTED PERFORMED DECONTAMINATION OF ECS PER AMM 21-00-00. AIRCRAFT OK TO CONTINUE SERVICE.SDR GTIA2025011638672Unknown · odorAIR QUALITY / FUME ECVENT. AFT GALLEY AND AFT CABIN SUDDEN STRONG "ROTTEN EGGS" SMELL AT 10,000 FT SLOWLY DISSAPATING OVER APPROX 10 MINUTES BOTH AFT FA HAD BURNING EYES AND STRONGEST ODOR-REF TSM 05-50-00--810-831 PER DECISION TABLE & AQE FORM PACK 2 FOUND TOSDR GTIA2025011638671Unknown · fumesSECOND FUME EVENT AFTER QRH PROCEDURE, PACK #2 OFF, SMELL DISSAPATED. SAME SMELL / INTENSITY AS PREVIOUS WRITE UP-REF LP 3602725-2 PER TSM 05-50-00-810-831-A PACK 2 FOUND AS SOURCE REF LP 3602727-2 FOR PACK DEFERRAL DESCRIPTION FUMES/ODOR: BURNING EYES AND ROSDR GTIA2024120238568Check Valve · leakingHYD Y RSVR LO LVL ECAM HYD RSVR SHOWS EMPTY -FOUND YELLOW CHECK VALVE ON ENG #2 LEAKING (FIN 3050GM). R&R HYD ENG #2 YL CHECK VALVE SEAL IAW AMM 29-13-36. R&R ENGINE PUMP DRAIN FILTER IAW AMM 29-11-43 DUE TO MOC REQUEST. PERFORMED OPS TEST OF YL HYD SYSTEM IAWSDR GTIA2024042838084Carpet · contaminatedDURING CRUISE AN ODOR WAS NOTICED BY BOTH FAS A AND B AND PASSENGERS IN FIRST TWO ROWS. NO ODOR NOTICED ON FLT DECK OR IN REAR OF A/C.-PERFORMED TSM 05-50-00-810-831 C.O.S. IS A TYPE 10 MISCELANEOUS. SMELL IS BETWEEN ROW 1-3 MORE ON THE LEFT SIDE & FWD LAV.CLESDR GTIA2023122937724Flashlight · inoperativeAFT EMER FA FLASHLIGHT INOP-R/R AFT EMER FA FLASHLIGHT IAW CMM 25-60-13 OPS CHECK GOODSDR GTIA2023052537209Sliding Window · damagedSLIDABLE COCKPIT SIDE WINDOW BLEW OUT ON CAPT SIDE-R&R CAPT SIDE SLIDING WINDOW PANEL IAW AMM 56-12-11. LEAK CHECK GOOD. R&R 2DG1 WINDOW HEAT CONTROLLER (PRECAUTIONARY) IAW AMM 30-42-34, OPS CHECK GOOD.SDR GTIA2023031337035Battery · no testREF TASK CARD 335100-03-1, CHECK BATTERY CAPACITY-R & R EPSU BATTERY (FIN 11WL) IAW AMM 33-51-38. TASK CARD HAS BEEN ACCOMPLISHED.SDR GTIA2022120936827Flashlight · inoperativeL2 JUMPSEAT FLASHLIGHT TEST INDICATOR INOP ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) R & R THE FLASHLIGHT ASSEMBLEY ON L2 JUMPSEAT IAW SPIRIT AIRLINES A/C DRAWING A320-200 EMERGENCY EQUIP LAYOUT. OPS CHECK GOOD. TSDR GTIA2022091536659Slide · detachedAFTER TAKEOFF L1 SLIDE DETACHED FROM DOOR-REINSTALLED L1 ESCAPE SLIDE RAFT PACK ASSEMBLY IAW AMM 25-62-44 OPERATIONAL CHECK OKSDR GTIA2022080836576Megaphone · malfunctionedFWD MEGA PHONE SIREN GOES OFF IN FLIGHT-REMOVED AND REPLACED FWD MEGAPHONE IAW A320-EMER EQUIP REV3.SDR GTIA2021041235681Ecu · odorAFT FA REPORTS ODOR CABIN FWD FA REPORTS ODOR ROW 1-3-ACCOMPLISHED TSM 05-50-00-810-831-A FOUND THROW UP ON ROW 3. NO LEAKS FOUND ON APU AND ENGINES USED AEROTRACER WHILE PACK 1&2 WERE RUNNING NO DEFECTS NOTED A/C OK FOR SERVICESDR GTIA202002135007Megaphone · failedFWD MEGA PHONE GREEN LIGHT DOES NOT COME ON WHEN HANDLE SQUEEZED-INSTALLED NEW MEGAPHONE FWD POSITION IAW AMM 25-60-01SDR GTIA2020021035004Reservoir · inoperativeDURING HMV FOUND RH OVER WING ESCAPE SLIDE RESERVOIR PINNED-INFO NOTED BY SPIRIT QUALITY IAW GMMSDR GTIA2019121204851Acm · contaminatedFUME EVENT AFT CABIN DIRTY SOCK AND HONEY SMELL ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )-PERFORMED PACK DECONTAMINATION IAW AMM 21-00-00-61SDR GTIA201910134693Unknown · odorFA REPORTED WET SOCK SMELL FROM ROW 21 TO AFT GALLEY-T/S DONE PER TSM 05-50-00-810-931-A, ODOR IDENTIFIED AS TYPE 9 MISC. AFTER CABIN WAS CLEANED ODOR WENT AWAY. BOTH PACKS OPER. AND CONFIRMED NO FAULTS, NO ODOR PRESENT IN CABIN. A/C OK TO CONTINUESDR GTIA201806072684Smoke Warning · false activationFWD CARGO SMOKE DURING CLIMB OUT, RETURNED TO DEPARTURE. R & R THE FWD CARGO SMOKE DETECTORS 1WH AND 2WH AS A PRECAUTION IAW AMM 26-16-15. PERFORMED AN OPS TEST OF THE SMOKE DETECTION SYSTEM IAW AMM 26-16-00. OPS TESTED GOOD. NO FAULTS NOTED.SDR GTIA2017061601979Wire Harness · misinstalledL2 & R2 EMERGENCY LIGHTS DO NOT TURN OFF. FOUND WIRING INCORRECTLY INSTALLED, CORRECTED WIRING IAW ASM 33-51-02 AND AMM 33-51-00SDR GTIA2017032901846Fastener · missingFO O2 MASK MISSING FASTENER OVER NOSE PIECE. R&R FO'S O2 MASK IAW AMM 35-12-41. OPS CHECK GOOD.SDR GTIA2016100501621Oxygen Mask · unwanted deployOXYGEN MASK DROPPED AT ROW 19DEF DURING TAXI OUT. PACKED AND STOWED THE OXYGEN MASKS IAW AMM 35-21-43 AND PERFORMED OPS CHECK OF THE MANUAL MASK RELEASE . OPS CHECKED GOOD IAW AMM 35-23-00.SDR GTIA2016050601444Oxygen Mask · brokenRED TAB ON F/O OXYGEN MASK BROKEN. R & R F/O OXYGEN MASK IAW AMM 35-12-41. OPS CHECK NORMAL, NO LEAKS DETECTED. ACFT OK FOR SERVICE.SDR GTIA2015022801520Oxygen Mask · unsecureROW 15 SEATS DEF OXYGEN DOOR OPEN AND MASKS "DANGLING" FROM OVERHEAD. REPACKED O2 MASKS/CONTAINER AT ROW 15DEF IAW AMM 35-21-43. PERFORMED OPS DROP TEST OF ROW 15 SEATS DEF OXYGEN MASKS IAW AMM 35-23-00-710-001-A, OPS TEST GOOD.SDR GTIA2015010801479Bottle · low pressureRIGHT AFT R2 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED THE BOTTLE IAW AMM 52-11-00-614-001-A.SDR GTIA2014122401473Bottle · low pressureR2 DOOR ASSIST BOTTLE DISPLAYS PRESSURE LOW. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00-614-001-A.SDR GTIA2014122101472Bottle · low pressureR & R DOOR ASSIST BOTTLE HAS LOW PRESSURE. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00-614-001-A.SDR GTIA2014121501467Bottle · low pressureR4 DOOR ASSIST BOTTLE LOW. SERVICED ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00-614-001-A. LEAK CHECKED GOOD.SDR GTIA2014112901460Bottle · low pressureDOOR ASSIST BOTTLE HAS LOW PRESSURE. DOOR ASSIST BOTTLE SERVICED IAW AMM 52-10-00.SDR GTIA2014110601447Bottle · low pressureDOOR ASSIST ACCUMULATOR LOW PRESSURE. SERVICED THE DOOR ASSIST ACCUMULATOR IAW AMM 52-10-00-614-001-A.SDR GTIA2014080101395Bottle · low pressureR2 DOOR ASSIST BOTTLE HAS LOW PRESSURE. R2 DOOR ASSIST BOTTLE SERVICED TO PROPER PRESSURE IAW AMM 52-10-00.SDR GTIA2014070601373Bottle · low pressureR2 DOOR BOTTLE HAS LOW PRESSURE. SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-12-14 LEAK CHECKED GOOD.
Back to N626NK