N630NK
Service difficulty reports · 57
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N630NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N630NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2017121102283Unknown · odorFA'S AND NUMEROUS PASSENGERS COMPLAINED OF BURNING RUBBER SMELL THROUGH 12,000' DECENT ROWS 15 AND BEYOND HAD MOST SMELL. TURNED PACK 2 OFF AND SMELL DID NOT GO AWAY. REAR FA'S HAD FUME EVENTS IN THE PAST AND CLAMED THIS WAS COMPLETELY DIFFERENT ODDER. PERFORMSDR GTIA2017072702123Flashlight · not seatedFA R2 FLASHLIGHT INOPERATIVE. RESEATED THE FLASHLIGHT. OP CHECKED GOOD IAW DWG NK320-232-EQ.SDR GTIA2017052101922Unknown · odorFUME EVENT DURING TAKEOFF AND ON DESCENT. PERFORMED COM PROCEDURES AND LANDED UNPRESSURIZED. PACK 1 OFF ON 1ST EVENT SOLVED. COULD NOT DUPLICATE THE PROBLEM DURING TROUBLESHOOTING. PERFORMED DECONTAMINATION OF ENVIRONMENTAL CONTROL SYS IAW AMM 21-00-00-6SDR GTIA2016110301650Unknown · odorFUMES ODOR DURING CLIMB , ISOLATED BLEED 1 AND ODOR DISEPATED UNTIL DECENT THEN ODOR RETURNED EVEN MORE SEVERLY. PERFORMED OPS CK OF THE PACKS SYS REF AMM 21-63-00. NO DEFECTS NOTED ON EITHER PACK , NO CABIN ODOR DETECTED ON EITHER PACK.SDR GTIA2016071001505Flashlight · inoperativeF.O.'S EMERGENCY FLASHLIGHT INOPERATIVE. R & R THE FLASHLIGHT IAW CMM 25-60-21-. OPS CHECKED GOODSDR GTIA2016041901525Flashlight · inoperativeF/O FLASHLIGHT INOPERATIVE. R & R F/O FLASHLIGHT IAW CMM 25-60-02. OPS CHECK GOOD. ALSO, IAW EMERGENCY DWG NK320-232-EQ.SDR GTIA2015052901568Oxygen Mask · leakingCAPTAIN OXYGEN MASK LEAKING. R & R CAPTAIN OXYGEN MASK IAW AMM 35-12-41. OPS & LEAK CHECKED OK.
Back to N630NK