N641GT
Service difficulty reports · 1,011
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N641GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N641GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2015070700328Unknown · malfunctionedMAX THRUST AT TAKEOFF N1 109.1, LT ENG WOULD ONLY GENERATE 106.6 N1 WITH THROTTLE TO STOP. ASSUMED TEMP REQUIREMENT 106.1, TROUBLESHOOTING ENGINE. R & R NR 1 ENG FUEL PUMP, R & R NR 1 ENG HMU, R & R NR 1 ENGINE EEC, R & R NR 1 ENGINE N1 SPEED SENSOR, R &SDR UIEA2015061000301Battery · dischargedAIRCRAFT MAIN BATTERY HAS LOW VOLTAGE. MAIN BATTERY REPLACED IAW MM 24-31-00. OPERATIONS CHECKED NORMAL.SDR UIEA2015060900299Fire Loop · malfunctionedSTATUS MESSAGE RT ENGINE FIRE LP1. R & R LOWER AFT LOOP IAW AMM 26-11-00. OPERATIONS CHECKED OK.SDR UIEA2015051800275Indicator · faultyLEFT FUEL QTY & TOTAL QTY INTERMITTENT IN CRUISE. STATUS MESSAGE FUEL QTY INDICATOR. R & R LT MAIN FQIS WIRE HARNESS, LT MAIN FQIS COMPENSATOR, LT DENSITOMETER ELECTRONIC UNIT, 14, 5, 6, 4 TANK UNITS CAUSE OUT OF LIMITS, ALL IAW AMM 28-11-01, 28-41-09, 28-41SDR UIEA2015051400272Warning System · false activationLEFT PACK EICAS MSG ON CLIMB OUT. PERFORMED FIM TASK 21-51 TASK 803 & REST OK. PERFORMED LT PACK COOLING TEST IAW AMM 21-51-00 & OK FOR SERVICE.SDR UIEA2015051400274Status Message · false activationLEFT FUEL QTY & TOTAL FUEL QTY INTERMITTENT IN CRUISE. FUEL QTY IND STATUS MSG. PERFORMED FIM 28-41 FT 861 & BITE CHECKED FQIS PROCESSOR IAW 28-41-00. MSG ERASED SYS OK FOR SERVICE.SDR UIEA2015050700264Eec · malfunctionedSTATUS MSG L ENG EEC C1. REMOVED AND REPLACED L ENG EEC IAW AMM 73-21-15, EEC TESTS 11 & 12 CARRIED OUT IAW IAW AMM 71-00-00 CONFIG 3 ALL NORMAL MDDR CLEARED.SDR UIEA2015050100249Fire Loop · faultyRIGHT ENG FIRE LOOP 1 EICAS STATUS MSG, PLACED ON DEFERRAL 26-11-01-01. REPLACED UPPER AFT LOOP TS681. CKS GOOD & NBSP.SDR UIEA2015041700238Slide · detachedR4 SLIDE DETACHED FROM DOOR WHILE GND HANDLING. INSTALLED SLIDE PACK IAW AMM 25-66-00. RETURNED ACFT TO ORIGINAL CONFIG & INSPECTED GIRT BAR IAW AMM 25-66-05. OK FOR SERVICE.SDR UIEA2015041700237Connector · looseSTATUS MESSAGE IN FLIGHT, RT ENGINE FIRE LOOP 1. INSPECTED RT ENG LOOP & FOUND LOOSE CONNECTION AT UPPER LT COWLING. SECURED CONNECTOR, OPERATIONS CHECKED GOOD IAW AMM 26-11-00.SDR UIEA2015041600234Status Message · false activationSTATUS MSG, L ENG EEC C1. ACCOMPLISHED PIMU BITE PROCEDURES IAW FIM 71-01-00 101, MSG ERASED. OK FOR SERVICE.SDR UIEA2015041300226Transceiver · failedLEFT WEATHER RADAR FAILED MESSAGE ON HSI. SWITCHED TO RT RADAR , RT OPS NORMAL. TRANSCEIVER REMOVED AND REPLACED IAW AMM 34-43-01, OPS CHECK GOOD.SDR UIEA2015040800216Light · inoperativeEXTERIOR EMER LIGHTS INOPERATIVE. REPLACED EXTERIOR EMER LIGHTS LT & RT SIDE. OPERATIONS CHECKED NORMAL AMM 33-51-06.SDR UIEA2015032900193Processor · malfunctionedLEFT WING TANK QTY DISPLAY BLANKS OUT INTERMITTENTLY. R & R FUEL QTY PROCESSOR IAW AMM 28-41-08. OPS CHECKED GOOD.SDR UIEA2015032500186Indication Sys · malfunctionedINTERMITTENT LOSS OF OVERHEAD FUEL QTY LEFT TOTAL, RESULTING IN EICAS MSG, LOW FUEL, & FUEL CONFIG MASTER CAUTION. FOUND FUEL QTY CHECKED GOOD. COMPLIED WITH FIM PROCEDURES IAW 28-41-02. NO FAULTS INDICATED.SDR UIEA2015030100156Valve · faultyBOTH PACKS RUNNING, UNABLE TO MAINTAIN CABIN TEMP BELOW OAT. DURING INSP FOUND RT PACK LOW LIMIT VLV FAULTY. R & R IAW AMM 21-51-11 201. OPERATIONS CHECKED OK.SDR UIEA2015021400118Starter · inoperativeNUMBER 2 STARTER INOPERATIVE ON DEPARTURE START-UP. R & R IAW AMM 80-11-01. OPERATIONS CHECKED SATISFACTORY.SDR UIEA2015020300076Ignition Lead · damagedNUMBER 1 ENG IGNITOR LEAD CERAMIC TIP BROKEN. R & R NR 1 RT IGNITION LEAD IAW AMM 74-21-01. OPERATIONS CHECKED NORMAL.SDR UIEA2015020400077Door · damagedLEFT PACK EXHAUST DOOR CUT OUT IS DAMAGED. R & R LT RAM AIR EXHAUST DOOR IAW AMM 21-53-02. OPERATIONS CHECKED NORMAL.SDR UIEA2015020400078Clamp · deterioratedLEFT ENG GENERATOR CLAMP DETERIORATED & MISALIGNED. FOUND CLAMP INSULATION MISALIGNED. REALIGNED INSULATION & SECURED CLAMP IAW AMM 20-10-12.SDR UIEA2015020400079Duct · damagedAPU AIR SUPPLY DUCT HAS A HOLE IN IT. R & R APU SUPPLY DUCT. LEAK CHECK OK IAW AMM 49-53-01.SDR UIEA2015020400080Door · damagedRIGHT PACK EXHAUST DOOR CUT OUT MISSING 3/8 PIECE. R & R IAW AMM 21-53-02. OPERATIONS CHECKED NORMAL.SDR UIEA2015020300075Socket · brokenRIGHT ENTRY DOOR UPPER FWD EMER LIGHT SOCKET IS BROKEN. R & R RT ENTRY DOOR UPPER FWD EMER LIGHT ASSEMBLY IAW AMM 33-51-03. OPERATIONS CHECKED NORMAL.SDR UIEA2015020300074Light · inoperativeSEVERAL CEILING EMER LIGHTS BURNED OUT. RELAMPED SEVERAL EMER CEILING LIGHTS IAW AMM 33-51-04. OPERATIONS CHECKED NORMAL.SDR UIEA2015020300073Light · inoperativeRIGHT OVERWING AFT EMER LIGHT BURNED OUT. CLEANED FWD SOCKET OF RT WING LIGHT ASSEMBLY. ALSO RELAMPED BULB IAW AMM 33-51-06 201. OPERATIONAL TESTED OK.SDR UIEA2015020300072Lens · unsecureAT SEAT ROW 5 CEILING EMER LIGHT LENS IS FALLING APART. SECURED EMER LIGHT LENS AT SEAT ROW 5 RT SIDE IAW AMM 33-51-01.SDR UIEA2015020300071Light · brokenRIGHT ROW SEAT & FLOOR EMER LIGHT BROKEN. REPLACED TRACK BOTTOM & LIGHT ASSEMBLY IAW 33-51-16 & AMM 33-51-06-201. OPERATIONS CHECKED OK.SDR UIEA2015020300070Light · damagedRIGHT ROW SEAT POSITION 29 LT IS TORN. REPLACED TRACK BOTTOM & LIGHT ASSEMBLY IAW DM 33-51-06 & AMM 33-51-06-201. OPERATIONAL TESTED OK.SDR UIEA2015020300069Light · brokenRIGHT ROW SEAT 30 FLOOR EMER LIGHT BROKEN. REPLACED EMER LIGHT ASSEMBLY IAW WDM 33-51-16 & AMM 33-51-06-201. OPERATIONS CHECKED OK.SDR UIEA2015020300068Light · brokenRIGHT ROW SEAT 36 FLOOR EMER LIGHT BROKEN. REPLACED EMER LIGHT ASSEMBLY IAW WDM 33-51-16 & AMM 33-51-06-201. OPERATIONS CHECKED OK.SDR UIEA2015020300067Light · brokenRIGHT ROW SEAT 37 FLOOR EMER LIGHT BROKEN. REPLACED EMER LIGHT ASSEMBLY IAW WDM 33-51-16 & AMM 33-51-06-201. OPERATIONS CHECKED OK.SDR UIEA2015020300066Pin · unsecureEMERGENCY WINDOW CTR EMER LIGHTS INOPERATIVE. SECURED EMER LIGHTS PIN AT CTR SEGMENT IAW AMM 33-53-03. OPERATIONS CHECKED NORMAL.SDR UIEA2015020300065Light · inoperativeRIGHT ROW SEAT 7 EMER LIGHT INOPERATIVE. RELAMPED RT ROW SEAT 7 FLOOR LIGHT IAW AMM 33-51-06-201. OPERATIONS CHECKED OK.SDR UIEA2015011300006Start Valve · malfunctionedLEFT ENG, NO RPM DURING START, MANUAL START SUCCESSFUL. LT ENG START VLV LIGHT OPERATES NORMAL. R & R START VLV. OPERATIONS CHECKED GOOD IAW AMM 80-11-02.SDR UIEA2014122400663Pump · malfunctionedDURING CRUISE FLIGHT, ENG CONFIG, EICAS MSG CAME ON TWICE DUE TO FUEL IMBALANCE BUT IMBALANCE RETURNED. LT TANK WOULD GO LOW & RT TANK HIGH. EACH TIME, FUEL CONFIG, MSG WOULD COME ON. R & R LT AUX TANK OVERRIDE FUEL BOOST PUMP IAW AMM 28-22-06. OPERATIONS SDR UIEA2014121100647Transceiver · malfunctionedRIGHT WX RADAR INOPERATIVE. R & R RT WEATHER TRANSCEIVER IAW AMM 34-43-01. OPERATIONS CHECKED GOOD.SDR UIEA2014120600630Unknown · malfunctionedFUEL APPEARS TO TRANSFER FROM LT MAIN TO RT MAIN IN FLIGHT. COMPLY FIM 28-41-TR824, FUEL CONFIG LIGHT OPERATIONS CHECKED GOOD & OPERATIONS CHECKED FUEL TRANSFER IAW FIM 28-41-TR842, NO DISCREPANCIES FOUND.SDR UIEA2014112300607Filter Element · leakingAPU INOPERATIVE FOUND FUEL LEAK AT APU FUEL FILTER. R & R FILTER ELEMENT & ORING IAW AMM 49-31-04. OPERATIONS & LEAKS CHECKED OK.SDR UIEA2014121800651Warning Message · false activationDURING CRUISE, FUEL CONFIGURATION, EICAS MESSAGE CAME ON TWICE DUE TO FUEL IMBALANCE. CORRECTED BUT RETURNED. LT TANK WOULD GO LOW & RT TANK HIGH. WHEN CTR TANK EMPTY FUEL IMBALANCE DISCONTINUED. APPEARS CENTER TANK PUMP DOES NOT OVERRIDE FWD & AFT LT PUMPSDR UIEA2014111800598Light · inoperativeAFT RT DOOR EXTERIOR & BOTH OVERWING EXTERIOR EMER LIGHTS INOPERATIVE, RELAMPED.SDR UIEA2014120300625Light · disconnectedEMERGENCY FLOOR LIGHTS LT FRONT, CREW AREA, SECTION DO NOT ILLUMINATE. RECONNECTED LT FRONT CREW AREA SECTION FLOOR PROX LIGHT IAW AMM 33-51-10. OPERATIONS CHECKED OK.SDR UIEA2014120300626Light · disconnectedLEFT SIDE ADJACENT TO THE LAVATORY A3L FLOOR, ONE EMER LIGHT IS INOPERATIVE IN THE STRIP SECTION. RECONNECTED LAVATORY A3L FLOOR PATH LAMP IAW AMM 33-51-10. OPERATIONS CHECKED ON.SDR UIEA2014103100515Warning System · false activationWX FAIL MSG ON MFD. WX RADAR WAS ON RT SIDE WHEN WE GOT THIS MSG, PERFORMED FIM 34-43 FAULT TREE 805 & SYS CHECKED OK LT & RT. NO FAULTS NOTED IN BITE PROCEDURE. OK FOR SERVICE.SDR UIEA2014092500464Indication Sys · fluctuatesRIGHT WING QTY INDICATOR FLUCTUATES SLOWLY IN FLIGHT +/- 600. ACCOMPLISHED FIM 28-41 FT 840 & FQIS BITE 28-41-00 501 & NO FAULTS FOUND, OK FOR SERVICE.SDR UIEA2014091700444Unknown · malfunctionedLEFT WEATHER RADAR IN NUMEROUS POSITIONS DISPLAYED ARE IN SOLID LINES. LT WEATHER RADAR SYS TEST CARRIED OUT IAW AMM 34-43-00 CONFIG 2 PAGE 501. ALL TEST PASSED, UNABLE TO DUPLICATE FAULT. OK FOR SERVICE.SDR UIEA2014091600442Transceiver · failedRIGHT SYS WEATHER RADAR DISPLAY WXR FAILED IN ALL MODES. R & R RT WEATHER RADAR TRANSCEIVER IAW AMM 34-43-00-001. THIS CLEARS MDDR 51264, PLACARD REMOVED.SDR UIEA2014091200439Acm · seizedAIR CONDITIONING RT PACK INOPERATIVE LIGHT ILLUMINATED. FOUND RT ACM SEIZED, R & R IAW AMM.SDR UIEA2014082300403Warning System · activatedDURING INITIAL CLIMB OUT FWD EQPT OVT EICAS MSG CAME ON WITH OVERHEAD LIGHT. USED QRH PROCEDURE & MSG & LIGHT CLEARED AFTER 30 MINUTES. ACCOMPLISHED EQUIPMENT COOLING. OPERATIONS TESTED OK IAW AMM 21-58-00.SDR UIEA2014081300397Eec · faultyENGINE NR 1 EEC SWITCHES TO ALTERNATE ON START. WILL NOT OPERATE IN NORMAL SETTING. R & R NR 1 ENG EEC IAW AMM 73-21-15.SDR UIEA2014080400352Warning System · false activationFORWARD EQUIPMENT & OVERHEAT EICAS CAUTION ON CLIMB OUT. COMPLETED QRH P 2.22 THRU STEP 7 FINISHED FLIGHT IN EQUIP COOLING SELECTOR IN AUTO. PERFORMED FIM 21-58-31-00 NO FAULTS INDICATED. OPERATIONS CHECKED IAW AMM 21-58-00. NO PROBLEMS FOUND, OPERATIONS C
Back to N641GT