N642UA
Service difficulty reports · 354
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N642UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N642UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013121393656Light · inoperativeAFT SEATS 27 - 39 SEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE. LIGHT ASSEMBLY ON SEAT 32JK & 36JK & REPLACED LIGHT BULBS AT SEAT 39JK & 38AB, OPERATIONS CHECKED GOOD IAW MM 33-51-10.SDR CALA2013121393655Battery Pack · dischargedAFT CABIN LT & CTR LAVATORY EMERGENCY EXIT LIGHT STRIPS INOPERATIVE. R & R M1556 BATTERY PACK IAW AMM 33-51-10, OPERATIONS CHECKED GOOD.SDR CALA2013110892747Spring · missingRT NOSE GEAR DOWN LOCK SPRING MISSING. REPLACED SPRING ASSEMBLY.SDR CALA2013102492374Connector · unsecurePIGTAIL P51 CONNECTOR FELL OFF. P51 CONTROLLER DEF INOPERATIVE. REQUIRES NEW PIGTAIL.SDR CALA2013102292249Wire · damagedFLIGHT ATTENDANT REPORTED RECEIVING SHOCKS FROM SEVERAL AFT GALLEY CARTS P51,P52, P53, P61 & P62. CHECKED GALLEY COUNTER TO GROUND, TESTED GOOD. CHECKED P51, P52, P53, P61 & P62, PIGTAILS FOR SHORTS TO COUNTER, FOUND NONE. FOUND PIGTAIL P53 WITH BAD LOCKING SDR CALA2013101091948Connector · damagedCONNECTOR D1942P PCN 563-1130 DAMAGED. NEEDS REPLACEMENT & TEST IAW 32-61-02 & WDM 32-61-12. R & R CONNECTOR D1942P & PERFORMED OPERATIONS CHECK IAW MM, OPERATIONS CHECKED GOOD.SDR CALA2013100991903Actuator · faultyLT REVERSER WILL NOT DEPLOY PAST IDLE REVERSE ON LANDING. REPLACED LT INTERLOCK ACT IAW MM, OPERATIONS CHECKED NORMAL.SDR CALA2013100491751Spring · brokenFOUND LT NLG BUNGEE SPRING BROKEN. REPLACED SPRING IAW MM.SDR CALA2013100491750Shutoff Valve · faultyLT ENG HPSOV STATUS MESSAGE. R & R NR 1 ENG HPSOV IAW MM.SDR CALA2013100291657Pdu · inoperativeAFT CARGO POWER DRIVE UNITS 10L AND 8L INOPERATIVE. REPLACED AFT CARGO POWER DRIVE UNITS 10L AND 8L PER AMM.SDR CALA2013093091541Regulator · disintegratedFIRST OFFICER`S OXYGEN MASK REGULATOR DISINTEGRATED. R & R FIRST OFFICER`S O2 MASK. LEAK & OPERATIONS CHECKED GOOD, IAW AMM-35-11-51. OK TO CONTINUE.SDR CALA2013090490979Warning System · false activationEICAS MESSAGE SPOILERS DISPLAYED. SPOILER LIGHT ILLUMINATED WITH SPOILERS SELECTED UP. LIGHT STAYS ON WITH SPEED BRAKE STOWED. ACP TEST OF SCM 1R MODULE FAULTED PCA XDR 1 OR 12 INT CRUISE. ACP TEST OF SPOILERS ALL OPERATIONS & INDICATIONS NORMAL. TESTED ACPSDR CALA2013082190644Amplifier · faultyREPLACED THE SATELLITE COMMUNICATIONS LOW GAIN AMPLIFIER M1783 DUE TO NUMEROUS FAULTS IN THE SATELLITE DATA UNIT FAULT HISTORY FOR 'LGA -HPA TX GAIN'. REPLACED LOW GAIN AUDIO MANAGEMENT PANEL, AUDIO CONTROL PANEL INSTALLATION TESTED GOOD.SDR CALA2013082190643Steering Unit · faultyREPLACED THE SATELLITE COMMUNICATIONS STARBOARD BEAM STEERING UNIT DUE TO SATELLITE DATA UNIT FAULT HISTORY ON NUMEROUS LEGS FOR 'HPR-STBD BSU'. REPLACED STARBOARD BEAM STEERING UNIT. AUDIO CONTROL PANEL INSTALLATION TESTED GOOD.SDR CALA2013081290339Truck · leakingLEFT MAIN GEAR LEAKING UNKNOWN FLUID. REPLACED LT MAIN GEAR TRUCK POSITIONER, OPS CHECKED OK.SDR CALA2013073090098Coffeemaker · sparksM71 COFFEEMAKER SPARKING. CAPTAIN HAD CIRCUIT BREAKER PULLED. REPLACED COFFEMAKER.SDR UALA2013061904255Actuator · leakingRUNNING HYDRAULIC LEAK OBSERVED FROM THE TAIL AREA. RT HYDRAULIC INDICATING 0.80. FOUND LOWER RUDDER PCA LEAKING. R & R LOWER PCA IAW AMM. RII PERFORMED.SDR UALA2013061704179Shield · damagedNOSE GEAR STEERING FIBERGLASS COVER DAMAGE TO LOWER RT CORNER. R & R NOSE GEAR STEERING FIBERGLASS SHIELD.SDR UALA2013052403600Pawl · damagedR1 DOOR UNABLE TO OPEN FROM THE INSIDE OR OUTSIDE. HANDLE STUCK IN CLOSED, NOT MOVING. R & R SERVICE DOOR PAWL. OPERATION FROM INSIDE AND OUTSIDE WITH NO PROBLEMS.SDR UALA2013052003451Windshield · delaminatedFORWARD WINDSHIELD DELAMINATED ON F/O SIDE. INSTALLED R1 WINDOW IAW AMM 56-11-01.SDR UALA2013052003452B-Nut · leakingHYDRAULIC FLUID LEAKING FROM NR 2 ENGINE STRUT DRAIN. FOUND EVIDENCE OF FLUID IN STRUT AREA. FOUND LEAKING B-NUT AT PYLON AREA. TIGHTENED B-NUT AND RESERVICED SYS IAW MM AND ACCOMPLISHED LEAK CHECK IAW MM 29-00-98, OK.SDR UALA2013043003034Latch · wornLEFT SIDE OVERWING SLIDE DOOR HAS A WORN LATCH SLIDER. REPLACED LATCH.SDR UALA2013043003014Pump · inoperativeLEFT ELECTRIC DEMAND PUMP INOPERATIVE IN AUTO AND ON. REPLACED LEFT ELECTRIC PUMP.SDR UALA2013041502543Seal · missingA SIX INCH RUBBER SEAL MISSING FROM RIGHT ENGINE INBD PYLON WING ROOT. REPLACED SEAL.SDR UALA2013040902369Pump · leakingNR 1 ENGINE HYDRAULIC PUMP FOUND LEAKING FLUID. REPLACED EDP PER MM AND CASE DRAIN AND PRESSURE FILTERS PER MM. TEST E AND LEAK CHECKED NORMAL.SDR UALA2013040502265Valve · failedEQUIPMENT COOLING 'VALVE' LIGHT ILLUMINATED. 'STBY' SELECTED & 'VALVE' LIGHT REMAINED ILLUMINATED. FOUND FORWARD OVERBOARD VALVE UNSERVICEABLE. REPLACED VALVE PER MM 21-23-08.SDR UALA2013032001718Valve · failedFWD EQUIPMENT VALVE EICAS ON LANDING. AFTER TROUBLESHOOTING FOUND INBOARD SUPPLY VALVE V91 FAULTY. REPLACED EQUIPMENT COOLING VALVE, OPS CHECK GOOD.SDR UALA2013030801398Door · brokenFIXED LEADING EDGE ICE DOOR AT WS 306, BENEATH LEFT KRUEGER FLAP, BROKEN IN HALF. REMOVED AND REPLACED ICE DOOR AT WS 306.SDR UALA2013030401284Control Valve · faultyRIGHT A/C PACK OFF LIGHT ILLUMINATED IN AUTO AND STDBY NORMAL. RESETS BUT THEN TRIPS OFF IN BOTH. REPLACE RT A/C PACK TEMP CONTROL VALVE PER MM.SDR UALA2012120406950Skin · tornNR 2 ENGINE OUTBOARD PYLON FAIRING SKIN TORN 45 DEG APPROX 2.5" X 2.5" AT STN 237 BELOW PANEL 447ERX. ACCOMPLISHED INTERIM REPAIR AS PER ECRA 5453-01057. REMOVED DAMAGED AREA AND PERFORMED COMPOSITE REPAIR TO PANEL REF. ECRA 5453-01057 AND SRM 51-70-10.SDR UALA2012111906673Skin · gougedDURING WALKAROUND MECH NOTICED A GOUGE ON FUSELAGE AFT OF AFT PIT DOOR ON RT SIDE. GOUGE IS 2 INCH LONG AND 0.005 DEPTH, LOCATED ON STA 1351, BETWEEN S29 AND S30 AND 3-4 OFF AN INCH FROM THE CARGO DOOR OPENING, PER LOCAL MECHANIC. DAMAGED AREA BLENDED AND VISDR UALA2012110606369Computer · faultyLEFT EICAS COMPUTER EICAS MESSAGE. REPLACED EICAS COMPUTER PER MM, OPS CHECKED OKAY.SDR UALA2012092705459Engine · faultyDUE TO PREVIOUS HISTORY OF RIGHT ENGINE HPSOV MSGS, PERFORM PNEUMATIC HEALTH CHECK OF THE HPSOV-HPC. PER MM 36-00-99-PG 514, STEP C. PAY PARTICULAR ATTENTION FOR SENSE LINE LEAKS. CORRECT ANY DISCREPANCIES FOUND. REMOVED ACCT ECM. REPLACED #2 ENGINE.SDR UALA2012092105367Latch · brokenRIGHT ENGINE REVERSER BAND LATCH INBOARD SIDE BROKEN OFF. REPLACED I/B BAND AND LATCH ASSY ON NR 2 ENGINE IAW AMM.SDR UALA2012091305169Warning System · false activationLEFT WING SLIDE EICAS MESSAGE DISPLAYED MOMENTARILY. INSPECTION DOOR COMPARTMENT FOR FAIR, NO ANOMALIES. SQUIB CHECK GOOD. CHECKED DOOR SECURITY.SDR UALA2012090404927Apu · faultyAPU AUTO SHUTDOWN, FLT DIVERTED. REPLACED APU FMU. PREVIOUS HISTORY. ACP ECU BITE FOUND AUTO SHUTDOWN LOP MESSAGES. DURING LEAK CHECKS FOUND FMU ATTACHMENT FLANGE CASTING LEAKING UNDER PRESSURE FROM HAIRLINE CRACK. REPLACED APU. OPS CHECK, LEAK CHECK NORSDR UALA2012090404926Fmu · leakingAPU FMU REQUIRES REPLACEMENT FOR TROUBLESHOOTING OF OIL LEAK. REPLACED APU FMU. ACCOMPLISHED ECU BITE FOUND AUTO SHUTDOWN LOP MSGS. DURING LEAK CHECKS FOUND FMU ATTACHMENT FLANGE CASTING LEAKING UNDER PRESSURE FROM HAIRLINE CRACK. UNABLE TO LOCATE IN IPC ESDR UALA2012083004873Engine · surgesENGINE SURGE, RETURNED TO FIELD. ENGINE SHUTDOWN 15-20 MINUTES FROM LANDING. METAL FOUND NR 2 ENG TAILPIPE. REPLACED NR 2 ENG.SDR UALA2012082804820Brake · fireNR 2 ENGINE EEC ISSUE, RTFL SMALL FIRE REPORTED FROM NR 4 BRAKE ASSY, COCKPIT INDICATION 9 UNITS, FUSE DID NOT MELT. REPLACED NR 4 REAR BRAKE ASSY REF MM DUE TO OVERHEAT AND REPORTED BRAKE FIRE.SDR UALA2012081304449Tire · failedNR 3 FWD TIRE WITH TREAD SEPARATION DUE TO RAN FLAT. REPLACED TIRE IAW AMM.SDR UALA2012081004353Connector · dirtyOFF FLAG IN CAPTS VSI. LEFT VSI ELECTRICAL CONNECTOR CLEANED. LEFT AND RIGHT VSI INSTALLATION TEST CARRIED OUT SATISFACTORY AS PER AMM. NO FURTHER FLAGS DISPLAYED.SDR UALA2012073104120Connector · damagedEMERGENCY LIGHT CONNECTOR BROKEN AT SEAT 36B. REPAIRED EMERGENCY LIGHT CONNECTOR AT SEAT 36B. OPS CHECKED GOOD.SDR UALA2012071703864Engine · failedAFTER TAKE OFF HEAVY VIBRATION 5.0 UNITS ENG1 SN.727667, THROTTLE PULLED BACK TO IDLE POWER TILL LANDING, FOUND EXTENSIVE DAMAGE TO SEVERAL FAN BLADES, INLET COWL, EXIT GUIDE VANES. NR 1 ENGINE HAS DAMAGE TO FAN EXIT OUTER CASE ALUMINIUM CASTING DAMAGED ON FSDR UALA2012071603836Transmitter · failedTROUBLESHOT C HYD PRIM 1 INTERMITTENT EICAS MESSAGE ON SHORT FINAL, GEAR DOWN AND DURING TAXI TO GATE. FOUND NO ACTIVE MESSAGE. REF SCHEMATIC 29-00-04. MESSAGE GENERATED FROM S33. PRESSURE TRANSMITTER REPLACED, CHECKED GOOD.SDR UALA2012061103213Light · intermittentL1 DOOR LOWER EMERGENCY EXIT LIGHT DOES NOT ILLUMINATE WHEN TESTED. LIGHTS OPS CHECKED NORMAL IAW 33-55-00-715-802.SDR UALA2012061103212Lamp · inoperativeTWO OVERWING EXTERIOR EMERGENCY LIGHTS ONE RT AND LT FORWARD OF AFT EMERGENCY LIGHTS ARE INOPERATIVE. RELAMPED, OPS CHECKED OK.SDR UALA2012052702992Line · leakingHYD FLUID LEAKING FROM THE LT MLG TRUCK POSITIONING ACTUATOR HOSE. APPROXIMATELY 12 DROPS PER MINUTE. REPLACED LINE PER AMM.SDR UALA2012052502925Hinge · looseOXYGEN MASK HANGING DOWN OVER FC FLIGHT ATTENDANT JUMPSEAT. FOUND PANEL HINGE LOOSE FROM PANEL. REGLUED PANEL PER B767 AMM. STOWED MASKS AND CLOSED PANEL. OK NOW.SDR UALA2012042502484Lamp · inoperative4TH EMERGENCY OVERWING EGRESS LIGHT AFT ON LEFT SIDE IS INOPERATIVE. RELAMPED AND SECURED CENTER CONTACT LUG. OP CHECKED NORMAL.SDR UALA2012042402453Light · brokenDOOR INTERIOR EMERGENCY EXIT LIGHTS THAT SHINES DOWN ON HANDLE IS BROKEN. REPLACED LIGHTS. OPS CHECKED GOOD.
Back to N642UA