N645GT
Service difficulty reports · 716
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N645GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N645GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2016042100255Light · looseMAIN PAX CABIN ROW 14 LT FLOOR EMER LIGHTING LOOSE. INSTALLED & SECURED PAX CABIN 14 LT FLOOR EMER LIGHT SYS. OPERATIONS CHECKED OK IAW AMM 33-59-00.SDR UIEA2016030900132Unknown · not reportedUNSUCCESSFUL COLD SOAK APU START. THREE ATTEMPTS AT FL 370 & -62°C SAT. NOTED BY MX, APU OPERATIONS CHECKED NORMAL ON GND IAW AMM 49-11-00. MDDR 64843 MEL 25-AP-01 REMAINS OPEN.SDR UIEA2016030200113Charger · malfunctionedAPU BATTERY CHARGER STATUS MESSAGE. R & R APU BATTERY CHARGER IAW AMM 24-31-05. OPERATIONS CHECKED OK.SDR UIEA2016030200112Clutch · malfunctionedAPU WILL NOT START. WILL NOT EXCEED 9 PERCENT RPM. TROUBLESHOT IAW FIM 694246 NR 7. R & R RELAY K117 IAW MCC REQUEST IAW WDM 24-31-41. REQUIRES OPERATIONS CHECK. APU START SATISFACTORY IAW AMM 49-11-00. LOG PAGE 694248 15 R & R STARTER CLUTCH & OPERATIONSDR UIEA2016022700111Switch · failedLEFT & RIGHT PACK MSG & EICAS MX PAGE. TROUBLE SHOT IAW FIM 21-51 FT 807, 844 TO PACK ALTITUDE SWITCH FAILED. PLACED ON MEL 21-51-05 CAT C MDDR 64614.SDR UIEA2016022400106Starter · failedAPU INOPERATIVE. DURING INSPECTION FOUND APU STARTER FAILED. REPLACED APU STARTER IAW AMM 49-41-01. OPERATIONS CHECK COMPLIED WITH.SDR UIEA2016021500095Status Message · false activationLEFT FWD FUEL PUMP EICAS MSG UPON LANDING. RESET CB IAW AMM 20-60-05, OPERATIONS CHECKED PUMP IAW AMM 28-22-00. OPERATIONS CHECKED NORMAL IAW FIM 28-22 FT 820.SDR UIEA2016021400093Relay · failedLEFT ENGINE ANTI-ICE EICAS ON ARRIVAL. QRH COMPLETED. R & R K650 LT ENG TAI CONT TD RELAY IAW WDM 20-21-11. OPERATIONS CHECKED NORMAL IAW MM 30-21-00.SDR UIEA2016021200087Apu · failedAPU FAULT LIGHT AFTER LANDING. THREE ATTEMPTS UNSUCCESSFULLY. R & R APU IAW MM 49-11-01. OPERATIONS CHECK & LEAK CHECK OK.SDR UIEA2016021200089Status Message · false activationSTATUS MSG, AFT EQ EXH FAN 2. PERFORMED FIM PROCEDURE IAW FIM 21-26 FT 808 NO FAULTS NOTED.SDR UIEA2016020800080Ecu · malfunctionedNO APU DUCT PRESS AFTER ENG START. R & R APU CONTROL UNIT. PERFORMED OPERATIONAL CHECK OK IAW MM 49-61-05.SDR UIEA2016020800079Status Message · false activationRIGHT ENG HPSOV STATUS MSG. RT ENG HPSOV BITE CHECK, NO FAULTS NOTED IAW FIM 36-20 TREE 804. RAN ENG IAW MM 71-00-00. RT ENG HPSOV OPERATIONS CHECKED GOOD.SDR UIEA2016020400046Wave Guide · unsecureSYSTEM 1 RADAR HAS TEMPORARY SPIKES & ECHOES IN DISPLAY. OPERATIONS NORMAL IN SYS 2. REPAIRED GND & SECURED WAVE GUIDE ON WEATHER RADAR RT. OPERATIONS CHECKED OK IAW 34-43-00.SDR UIEA2016020200036Shutoff Valve · faultyAPU PNEUMATIC FUNCTION ONLY PRODUCING 2 PSI AIR PRESS. WILL RISE AT ENG START SIGNAL. RECEIVED APU BITE P2 SENSOR FLAG 16. R & R VARIABLE VOLUME CHAMBER ON APU. R & R INLET TEMPERATURE SENSOR ON APU. R & R SOLENOID VLV ASSEMBLY ON APU. IAW AMM 49-53-07, SDR UIEA2016012700031Shutoff Valve · inoperativeAPU PNEUMATIC FUNCTION INOPERATIVE. OPENED MEL 49-11-01-01, REQUIRES TROUBLESHOOTING. R&R VARIABLE VOLUME CHAMBER ON APU. R&R INLET TEMPERATURE SENSOR ON APU. R&R SOLENOID VLV ASSEMBLY ON APU IAW AMM 49-53-07, 49-61-04 & 49-27-08. OPERATIONAL CHECK ON APUSDR UIEA2016012400028Bleed Air Sys · malfunctionedAPU AIR INOPERATIVE. PERFORMED FIM TK 49-11FT987, FLAG 16 & LRU P2 SENSOR LATCHED, CLEARED & BITE SELF-TESTED NORMAL. APU AIR ON LAST 2 LEGS, NO FAULTS, IAW FIM 49-11 FT 987. OPERATIONS CHECKED NORMAL.SDR UIEA2016011500019Switch · faultyAPU FAULT & APU BATTERY DISCHARGE EICAS MSG. AFTER LANDING APU START IAW MEL 49-11-1B. REPLACED LOW OIL TEMP SWITCH IAW AMM 49-27-14. OPERATIONS CHECKED NORMAL.SDR UIEA2016011400016Oil System · lowAPU FAIL TO START IN FLIGHT AT FL 350, TRIED AGAIN TO START APU AT FL 200, FAILED, TRIED A THIRD START AT 7000 FT, START FAILED. ENG CONTROL UNIT STORED FAULT, ABORTED START NO LIGHT OFF. SERVICED APU WITH 0.5 QTS OF OIL IAW AMM 12-14-03. OPERATIONS CHECK &SDR UIEA2016011000008Control Unit · faultyAFTER LANDING GOT APU FAULT EICAS MSG. 3 ATTEMPTS NOT SUCCESSFUL. R & R APU CONTROL UNIT IAW AMM 49-61-05. OPERATIONS CHECKED GOOD.SDR UIEA2016011000007Pressure Switch · faultyLEFT AFT FUEL PUMP SWITCH DOES NOT ILLUMINATE WHEN SELECTED OFF. NO ASSOCIATED EICAS MSG. R & R FUEL PRESS SWITCH AT LT AFT BOOST PUMP IAW AMM 28-22-01. LEAK & OPERATIONS CHECKED OK.SDR UIEA2016010800006Indication Sys · malfunctionedDURING FUEL CROSS FEED, LT AFT FUEL PUMP PRESS LIGHT FAILED TO ILLUMINATE WITH PUMP SWITCH OFF. COULD NOT DUPLICATE ON GND. OPERATIONS CHECK FUEL BOOST LT AFT GOOD IAW AMM 28-22-03.SDR UIEA2015123000798Unknown · malfunctionedIN CRUISE WHILE BALANCING FUEL, THE LT AFT FUEL PUMP WOULD NOT CYCLE OFF WITH THE LT AFT FUEL PUMP IN OFF POSITION. OPERATIONS CHECKED IAW AMM 28-22-00. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2015123000800Apu · malfunctionedAPU FAILED TO START. VERIFIED OIL QTY TO FULL, STARTED & OPERATIONS CHECKED APU IAW M 49-41-00. APU STARTED & OPERATED. NO DEFECTS NOTED.SDR UIEA2015122200790Skin · delaminatedFOUND DAMAGE TO INTERIOR OF ENG NR 2 LT COWL. ACCOMPLISHED EO 6771A013 & ENG COWLING NR 2 ENG & LT FAN COWL INTERNAL SKIN DELAMINATED. DAMAGE REPAIR COMPLETED PART 1.SDR UIEA2015121500729Warning System · false activationLEFT WING ANTI-ICE EICAS MSG AT 4000, WITH SWITCH OFF ON ARRIVAL. OPERATIONS CHECKED SYS IAW AMM 30-41-00, NO DEFECT NOTED AT THIS TIME.SDR UIEA2015121700743Oil System · lowAPU FAULT EICAS DURING APU START, APU DID NOT START. INSPECTED APU OIL QTY, FOUND APU OIL LOW, SERVICED APU OIL TO PROPER LEVEL IAW AMM 49-27-00, NO LEAKS NOTED. APU OPERATIONS CHECKED NORMAL.SDR UIEA2015121100725Control Valve · failedRIGHT PACK TEMP EICAS. R & R TEMP CONTROL VALVE IAW AMM 21-51-12. OPS CHECKED NORMAL.SDR UIEA2015121100724Warning System · false activationRIGHT PACK TEMP EICAS & PREFORMED FIM IAW FIM 21-51 F T 803 AT BLOCK 48, PROCEED TO TABLE B WITH FAULT LIGHT TEMP CONT VLV. ACCOMPLISHED STEP 1 A THRU E PERFORMED VERIFY BITE CHECK. OPERATIONS CHECKED NORMAL SYS IS OK IAW FIM. WILL MONITOR TCV POTENTIOMETERSDR UIEA2015111700670Light · inoperativeEXTERIOR EMER LIGHT RT 3RD LIGHT INOPERATIVE. RELAMPED EMER LIGHT RT EXTERIOR. OPERATIONS CHECKED NORMAL IAW AMM 33-51-00.SDR UIEA2015111700671Smoke Goggles · crackedCOCKPIT 2ND OBSERVERS SMOKE GOGGLES HAVE CRACKED LENS, PN MXP210-00. R & R SMOKE GOGGLES IAW AMM 25-64-00.SDR UIEA2015111600654Oil System · lowAPU START FAULT, 3 ATTEMPTS. ADDED .3 QTS OF OIL & OPERATIONS CHECKED OK IAW AMM 49-00-00.SDR UIEA2015111700660Unknown · malfunctionedCONSTANT FUEL IMBALANCE IN FLIGHT WITH CROSS FEEDS OPEN & LT AFT FWD PUMPS OFF. LT AFT PUMP SHOWS NO LOW PRESS LIGHT OR EICAS MSG. COULD NOT DUPLICATE ON GND, NO DEFECTS NOTED AT THIS TIME IAW MM 28-22-03.SDR UIEA2015110400610Oil System · leakingNUMBER 1 ENG OIL QTY DECREASED 10QTS IN 29 MIN, LARGEST QTY INDICATED WAS 10 QTS INCREASED DURING DESCENT. PERFORMED FIM 79-11 TREE 800 STEPS 1 - 6 & STEPS 6 - 15 SCAVENGE OUT PORT SCREEN NO DEBRIS FOUND IAW MCC & POWER PLANT ENGINEERING. PERFORMED FIM 79-31SDR UIEA2015110300603Warning System · false activationNUMBER 1 WX RADAR SYS FAILED, WX RADAR SYS STATUS MSG. PERFORMED OPERATIONS CHECK & BITE CHECK OF THE NR 1 WX RADAR IAW AMM 34-43-02, NO DEFECTS NOTED.SDR UIEA2015110300604Apu · malfunctionedAPU COLD SOAK START FAILED, APU STALLED, FAULT AT 30% RPM, APU OIL WENT FROM FULL TO 0.25, 1 ATTEMPT MADE ONLY. PERFORMED BITE TEST ON ECU IAW FIM 49-11 FT 987. TROUBLE SHOT IAW FIM 49-11FT988, NO FAULTS NOTED. START ON GND & SUBSEQUENT START. OPERATIONS CSDR UIEA2015110300605Unknown · malfunctionedFUEL MIGRATION CONTINUES, INITIAL IMBALANCE SHOWED RT WING HVY, 1.5 POUNDS. SUBSEQUENT MIGRATION SHOWED RT WING HVY, 1.9 POUNDS. CROSS FEED SUCCESSFUL, OK FOR SERVICE IAW SVC LETTER 767-SL-28-035-A, OK FOR SERVICE.SDR UIEA2015110300606Unknown · malfunctionedFUEL MIGRATION FROM RT TO LT TANK, 1500 LBS PER 2.5 HRS. ACFT OK TO CONTINUE IAW SVC 767-51-28-035-A.SDR UIEA2015110200601Relay · failedWING ANTI-ICE SYS FAILED GND CHECK. R & R RELAY K319 IAW MM 30-11-01. OPERATIONS CHECK COMPLIED WITH.SDR UIEA2015110200600Bypass Valve · malfunctionedDUE TO FUEL IMBALANCES FROM LT TANK TO RT TANK IN FLIGHT, RT MAIN TANK TROUBLE SHOT IAW 28-11-01 REQUIRED & WO 11148. WO 11148 COMPLIED WITH FOR LT TANK TO RT TANK FUEL MIGRATION. THE FOLLOWING ACTIONS WERE ALSO PERFORMED, LP 550787 M16, R & R RT MAIN TANK FSDR UIEA2015102600590Warning Light · illuminatedFUEL CONFIG LIGHT ILLUMINATED & LT TANK 9.7 & RT TANK 12.4. OK FOR CONTINUED SERVICE IAW SERVICE LETTER 767-SL-28-035A.SDR UIEA2015102200586Processing Unit · faultyFUEL QTY PROCESSOR ACCOMPLISHED FAULTS LM, RM & CTR CIRCUIT BOARDS. R & R FUEL QTY PROCESSOR. ACCOMPLISHED FUEL QTY SYS IAW AMM 28-41-08, OPERATIONS CHECKED NORMAL.SDR UIEA2015101900583Warning System · false activationGOT EICAS MSG FUEL CONFIG 3 TIMES, RAN CHECKLIST. FIRST MSG WHILE USING CTR TANK FUEL & LT TANK WAS LOW WHEN CTR TANK EMPTY, RT TANK BECAME LOW. RAN BITE ON FQ PROCESSOR IAW AMM 28-41-00. FAULTED LM BOARD CLEARED MSG & RAN BITE AGAIN FOR CURRENT FAULTS, NONSDR UIEA2015100400570Connector · dirtyBEFORE ENG START, AFTER EICAS REVIEW, NO LT & RT CTR FUEL PUMP MSG AS EXPECTED. INSPECTED, CLEANED CONNECTOR AT RT CTR PUMP PRESS SWITCH. OPERATIONS CHECKED OK IAW AMM 28-22-00 & 20-60-01.SDR UIEA2015092700554Periseal · leakingDIFFUSED LEAK IN THE RT AIR CONDITIONING BAY AT BODY CROSS OVER DUCT OTBD OF CHECK VLV. REPLACED PERI-SEAL IAW AMM 36-11-01.SDR UIEA2015092700553Hose · leakingDIFFUSED LEAK IN THE RT & LT AIR CONDITIONING BAY AT HOT AIR LINE FROM COMPRESSOR TO CONDENSER. REPLACED HOSE AT CONDENSER TO HOT AIR LINE IAW AMM 21-51-10, NO LEAKS NOTED.SDR UIEA2015092700549Warning System · false activationSTATUS MSG FUEL QTY CHANNEL. PERFORMED FIM PROCEDURE IAW FIM 28-41 FT 861, NO FAULTS NOTED.SDR UIEA2015092700550Warning System · false activationLEFT WING ANTI-ICE MSG DURING DESCENT, COMPLIED WITH QRH. TROUBLE SHOT IAW FIM 30-11 FT 803. SYS OPERATIONS CHECKED OK.SDR UIEA2015092700551Warning System · activatedFUEL CONFIGURATION MSG ON APPROACH. NO ACTION TAKEN. FUEL IMBALANCE IN FLIGHT IS WITHIN LIMITS IAW SL 767-SL-28-035A.SDR UIEA2015092700552Line · obstructedLEFT PACK WATER SPRAY NOZZLE NOT SPRAYING WATER. REMOVED & REINSTALLED WATER SPRAY NOZZLE. REMOVED DEBRIS FROM WATER SPRAY LINES IAW AMM 21-53-05. OPERATIONS CHECKED NORMAL.SDR UIEA2015092400547Shutoff Valve · leakingFUEL IMBALANCE MULTIPLE TIMES DURING FLIGHT. FOUND FUEL LEAKING FROM, FLOAT OPERATED SOV, IN LT TANK. REPLACED LT FLOAT OPERATED SOV IAW AMM 28-22-10, NO LEAKS NOTED.