N648UA
Service difficulty reports · 327
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N648UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N648UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013071905079Insulation · damagedPRESSURIZED PNEU DUCT FROM APU, FOUND NO LEAKS. OPS CHECKED BULK AND AFT CARGO HEATING SYS, FOUND NO LEAKS. OPS CHECKED ADP, FOUND NO LEAKS. INSULATION BLANKET ON PNEU DUCT UNDER SEAT 36 AND 37 AB FOUND DAMAGED. REPLACED INSULATION BLANKET.SDR UALA2013071504939Insulation · damagedCREW REPORTED FLOOR AND SIDEWALL AREA AROUND ROWS 36 AND 37 ARE ABNORMALLY HOT. TURNED OFF AFT CABIN TRIM AIR, NO HELP. DAMAGED BLEED DUCT INSULATION BLANKET WAS REPLACED, NO LEAKS DETECTED.SDR UALA2013052403612Blade · nickedNR 2 ENGINE FAN BLADE NR 19 HAS NICK 4 INCHES FROM BLADE TIP. PERFORMED PRELIMINARY BLADE BLEND. ACCOMPLISHED HFEC AS REQUIRED REF MM AND NDT MANUAL PART 672-31-401. STILL REQUIRES ADDITION .020" BLENDING REF MM 72-31-02 AT BLADE NR 19. BLENDED BLADE ADDITSDR UALA2013052403611Blade · nickedNR 2 ENGINE FAN BLADE, NR 38 HAS A NICK IN THE L/E ONE INCH FROM TIP. PERFORMED PRELIMINARY BLADE BLEND ON BLADE NR 38.SDR UALA2013052103510Skin · dentedDENT ON FUSELAGE SKIN AT BS 289 AND STRINGER 25R. FOUND WITHIN LIMITS REF SRM 53-00-01 A D1.SDR UALA2013043003010Pawl · brokenFOUND R2 DOOR OUTSIDE SLIDE ARMING MECHANISM PAWL BROKEN. ARMING PAWL REPLACED IAW AMM.SDR UALA2013040802310Control Panel · faultyPWS INOP LIGHT DOES NOT TEST. REPLACED WX RADAR CONT PANEL, OPS CHECK NORMAL.SDR UALA2013040502269Smoke Detector · faultyEICAS MESSAGE - FWD SMOKE DET 1. FORWARD SMOKE DETECTOR NR 1 REPLACED AND OP CHECK OKAY.SDR UALA2013032701969Filter · defectiveINFLIGHT COCKPIT AIR NOISE TOO LOUD RECIRC FANS NOISY. REPLACED RECIRC HEPA FILTERS.SDR UALA2013031401541Lens · damagedRIGHT GENERATOR DRIVE DISCONNECT SWITCH MISSING BALE WIRE FROM SWITCH BODY TO LENS CAP. LENS CAP FITTED WITHOUT BALE WIRE, SWITCH OPS ARE NORMAL. REPLACED RIGHT GEN DRIVE LENS AND REPLACED GUARD, SAFETIED BOTH DISC SWITCHES.SDR UALA2013022801212Control Valve · faultyCOCKPIT FAR TOO MUCH NOISE WITH PACKS ON. CANNOT HEAR CHECKLIST OR ATC GROUND AND IN AIR. REPLACED AIR RECIRCULATION FAN CONTROL VALVE, OPS CHECK GOOD.SDR UALA2013022801213Coupler · not seatedSPLIT BETWEEN ALTIMETERS BEYOND 40FT LIMIT. RESEATED QUICK COUPLERS ON LEFT ADC, ALL INDICATIONS WERE WITHIN LIMITS.SDR UALA2013021400880Valve · leakingAFT WATER DRAIN LINE CONTINUES TO DRIP AFTER VALVE IS CLOSED. 643-0044 ON AOM V5969. REPLACED FILLING - DRAIN WATER VALVE, CHECK NO LEAKS.SDR UALA2013020700746Structure · damagedACCOMPLISHED BIRD STRIKE CONDITIONAL INSPECTION. DAMAGES FOUND ON LT WING OUTBOARD FLAP LOWER SIDE AT 32 INCHES FROM OUTBOARD AFT EDGES OF FLAP. REPLACED LEFT WING OUTBOARD FLAP IAW AMM-27-51-20 RIG AND OPS CHECKED OK.SDR UALA2013020100590Stop · detachedCONTAINER REAR STOP BLOCK DETACHED LOCATION 402, LEFT SIDE OF BUS GALLEY. RESECURED STOP BLOCK.SDR UALA2013012400416Screw · missingONE SCREW STICKING OUT AND POSSIBLY ONE MISSING ON THE LEFT SIDE OF THE VERTICAL STAB. REPLACED MISSING SCREWS AND TWO EACH NUT PLATES.SDR UALA2013011600283Switch · failedCENTER ELEC HYD PUMP DOES NOT PROMPT AN EICAS WHEN TURNED OFF. REPLACED C2 SWITCH BASE ASSY IAW SWPM 20-84-14, WD 29-11-31 AND MM 29-11-00 CENTER HYD SYS TEST. NO FAULTS FOUND EICAS AND PRESSURE LIGHT NORMAL.SDR UALA2012122407399Generator · faultyAPU GENERATOR TRIPS. ON GROUND APU GENERATOR KICKED OFF. REPLACED APU GENERATOR.SDR UALA2012112906849Latch · out of adjustNR 1 ENGINE PYLON ACCESS INBD & OUTBD DOORS HAVE 6 EA LATCHES OPEN ON AIRCRAFT ARRIVAL. LATCHES NEED TO BE ADJUSTED. REPLACED 7 EA LATCHES, AND 8 LATCH STRIKERS.SDR UALA2012110906463Relay · faultySQUIB TEST 1 EMERGENCY ESCAPE R DOESN'T ILLUMINATE. REMOVED & REPLACED K3 RELAY SLIDE DOOR TEST RELAY REF WDM 25-65-12. WPB 73611 OPS CHECKED NORMAL.SDR UALA2012103006242Filter · faultyELECTRIC SMOKE SMELL, RTFL. AFTER TAKEOFF, F/A REPORTED ELECTRICAL SMELL-CARD BOARD BURNING SMELL IN THE MID CABIN AREA. BUSINESS CLASS AND ECONOMY PLUS SECTIONS. ONCE UTILITY BUSES TURNED OFF, SMELL DISSIPATED. F/A DIRECTED MM TO SMELL FROM MID CABIN GALLSDR UALA2012101805948Oil Cooler · faultyNR 2 ENGINE-TS AOC MSGS, AOC? 6448-2 ESN 727790 - ENGINE IS DOWNLINKING CH A&B AOC TR CHECK FAIL MSG 351-23. REMOVED NR 2 ENGINE AIR-OIL COOLER. REF AMM 79-21-09 TASK 79-21-09-004-801. REF EG7491-2, REPLACE NR 2 ENGINE AIR-OIL COOLER (HEAT EXCHANGER).SDR UALA2012101605910Yaw Damper · faultyLEFT YAW DAMPER INOPERATIVE. TROUBLESHOT TO BAD LEFT YAW DAMP MODUAL REPLACE SAME AS PER AMM. OPS CHECKS NORMAL. AC REMAINS CAT FULL CAPABLE. INSTALLED BORROWED PART PN 99-222 1-9-0001 SN 0937 MG PN 285T0013-123.SDR UALA2012100405628Drive Assy · failedWXR FAIL DISPLAYED ON HSI. WXR FAIL ANT DISPLAYED ON HSI IN WXR TEST POS. REMOVED AND REPLACED WX ANT DRIVE ASSY, OPS CHECK GOOD.SDR UALA2012100205578Sensor · faultyFUEL TEMP INDICATION ON FUEL PANEL BLANK. REPLACED FUEL TEMP SENSOR TS168, OPS NORMAL.SDR UALA2012091405213Sliding Window · faultyRIGHT SIDE WINDOW HEAT INOPERATIVE. REPLACED WINDOW HEAT CONTROLLER PER MM 30-41-01 PG 401, NO HELP. REINSTALLED ORIGINAL WINDOW HEAT CONTROLLER. INSPECTED WIRES AND LUGS FOR LOOSENESS AND NO DEFECTS NOTED REF WDM 30-41-01. NR 2 WINDOW HEAT CONTROLLER SHOWSDR UALA2012091005084Switch · stuckLEFT FWD FUEL PUMP SWITCH STUCK IN 'ON' POSITION. REPLACED SWITCH.SDR UALA2012080804271Switch · dirtyRT RECIRCULATION FAN LIGHT FAILS TO TEST. LIGHT WORKS BY OPERATING THE RECIRCULATION FAN SWITCH. THE LIGHT DID NOT WORK WHEN USING THE LIGHT TEST SWITCH. CLEANED SWITCH, OPS CHECK NORMALSDR UALA2012072504039Bulb · inoperativeRIGHT EMERGENCY ESCAPE SLIDE RIGHT TEST ONE INOPERATIVE. RESEATED BULB IN TEST PANEL, OPS CHECKED GOOD.SDR UALA2012051802841Actuator · leakingHYDRAULIC FLUID LEAKING FROM BOTTOM OF TAIL AT 10 DROPS PER SECOND. RUDDER RATIO ACTUATOR LEAKING. REPLACED RUDDER RATIO CHANGER ACTUATOR IAW MM. OPS AND LEAK CHECKED NORMAL.SDR UALA2012051102731Control Unit · faultyWITH HYD ON, RIGHT INBOARD AILERON BANGING AND SHAKING ACFT. REPLACED RIGHT 3R SCM, TEST PASSED.SDR UALA2012051102730Oil System · leakingAPU FAULT TWICE. FOUND NO OIL IN APU TANK, AND APU COMPARTMENT OIL SOAKED. REPLACED APU PER MM.SDR UALA2012050802670Track · wornR1 DOOR UPPER FWD TRACK WORN. REPLACED DOOR UPPER TRACK PER SRM. REPLACED TROLLEY ROLLERS PER AMM. ACCOMPLISHED DOOR ADJUSTMENT AND TEST PER AMM, OPS CHECKED GOOD.SDR UALA2012050802671Stiffener · crackedBS 246 FLOORBEAM VERTICAL STIFFENER ON FWD SIDE AT RBL 16 CRACKED IN RADIUS. FABRICATED AND REPLACED VERTICAL STIFFENER, REPAIRED AFT MOUNTING BRACKET AND PULLEY BRACKET PER SRM'S. OPS CHECKED GOOD PER AMM. MAJOR REPAIRSDR UALA2012051002707Structure · corrodedCORROSION ON CANTED DECK AT STA 955, RBL 12. REMOVED CORROSION PER SRM. ACCOMPLISHED HFEC OF HOLES PER NDTM 51-00-19, PRT 6, NO CRACKS NOTED. ACCOMPLISHED FHRS FOR THICKNESS PER NDTM 51-00-16, PRT 6. FLAP PEENED AREA PER SRM 51-20-06, ECRA 5710-02234, AND EA SDR UALA2012050302608Bulb · inoperativeEMERGENCY LIGHT CEILING ABOVE SEATS 6AB INOP. REMOVED AND REPLACED LIGHT BULB IAW 33-51-04.SDR UALA2012050202592Floorbeam · corrodedAFT CARGO BAY, BS 1153, RBL 23 - 42, FLOORBEAM CAP CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM 53-00-07. FABRICATED NEW FLOORBEAM CAP IAW SRM 51-40-05 AND INSTALLED IAW SRM 51-40-02.SDR UALA2012050202591Oxygen Mask · misinstalledPASSENGER CABIN, PAX O2 MASKS IMPROPERLY PACKED. REPACKED ALL PASSENGER O2 MASKS.SDR UALA2012050202590Shear Tie · corrodedFUSELAGE BS 1562 BETWEEN STRINGERS S-39L-39R SHEAR TIE CORRODED. REMOVED AND REPLACED SHEAR TIE REF SRM51-40-02.SDR UALA2012040602146Panel · unsecureOVERHEAD OXYGEN PANEL HANGING DOWN AT SEAT 26K. SECURED PANEL.SDR UALA2012040302073Control Panel · smokeFWD CARGO DOOR CONTROL PANEL. SMOKE OBSERVED COMING FROM PANEL DURING DOOR OPERATION. AFTER COMPLETION OF LM3415 AND NO WIRE DAMAGE IS CONFIRMED, INOPERATIVE FWD CARGO DOOR ELECTRICAL FUNCTION PER MEL 5230AB PROCEDURES. ACCOMPLISHED REQ OF LM3415. NO WIRESDR UALA2012030101289Wire · pulledLEFT SIDE WINDOW HEAT INOP. FOUND GND WIRE AT LEFT WINDOW 2 CONNECTOR D5872P POS 2 WIRE W624-101O-20 HAD PULLED OUT OF SOCKET, RETERMINATED AND SECURED WIRE. WINDOW HEAT TEST OKAY.SDR UALA2012022701150Cable · smokeFOOD CART CONTROLLER CORD 'N51' STARTED SMOKING. CREW SELECTED SWITCH TO OFF, OPENED CB AND DISCONNECTED CART CORD. SMOKE DISSIPATED. RESET CB &CONNECTED CART RAN FOR 15 MINS, INSPECTED PIGTAIL AND CONNECTORS, NO SIGN OF DAMAGE OR SMOKE-SUSPECT POSS PROBLEMSDR UALA2012022001034Generator · crackedAPU SHUT DOWN ON ITS OWN. FAULT LIGHT ON. FOUND LARGE CRACK IN APU GENERATOR CASING, CAUSING APU OIL LOSS. APU GENERATOR REPLACED AS PER AMM, ALL CHECKED OKAY.SDR UALA2012013000585Rvdt · faultyAFTER FLAP EXTENSION, GOT FLAP SLAT ELEC STATUS MSG AND DURING FLAP SLAT RETRACTION GOT T/E CAUTION LIGHT. REPLACED M548 SLAT TRANSDUCER RVDT PER MM 27-81-11 PAGE 412 AND ACP TESTS PER MM 27-51-00 PAGE 501 AND MM 27-81-00 PAGE 501 SYS PASSED OKAY.SDR UALA2012013000603Satcom · faultyNO COMM DISPLAYED ON ACARS DISPLAY UNIT OVER OCEAN. ACARS SENDS OK IN VHF RANGE. CREW COMMENTS: SATCOM CONSTANTLY REQUESTING LOGON. SAMC TEXT: MAINTENANCE REPORT SATCOM SYSTEM INOP HIGH & LOW GAIN. AFTER SAT AND ACARS SYSTEM RESET IDU SHOWS SATCOM ALWAYS ISDR UALA2012011200270Restrictor · deterioratedBLEED AIR LEAK. EXCESSIVE AIR NOISE ABOVE CROSS AISLE JUMP SEAT AFT OF FWD GALLEY. INSPECTED DUCTING ABOVE CEILING, ALL CONNECTIONS LOOK GOOD AND FLOW IS GOOD. FURTHER INSP FOUND AIRFLOW RESTRICTORS DETERIORATED AT THE PLENUM FOR THE OVERHEAD AIR OUTLET ABOSDR UALA2011122207068Slat System · false indicationWITH FLAPS BETWEEN 1 AND 5, GET "M548 OTBD SLAT PDU RVDT MISRIG" FAULT ON UNIT. OPERATED FLAPS THROUGH FULL RANGE OF OPERATION TWICE. COULD NOT DUPLICATE PROBLEM.SDR UALA2011122107052Indicator · defectiveCABIN PRESSURIZATION VSI RATE GOING FROM 0 TO 2000 FPM RAPIDLY. REPLACED CABIN PRESS INDICATOR, OPS NORMAL.SDR UALA2011093005304Blade · nickedNR 1 ENGINE HAS 2 BLADES NICKED. BLENDED BLADES.
Back to N648UA