N655AE

Service difficulty reports · 198

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N655AE' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR HNAA2025011100022None · no discrepancyBIRD STRIKE ON LH SIDE OF NOSE. PERFORMED BIRDSTRIKE INSPECTION IRW AMM 05-50-08. NO DAMAGE NOTED. A/C OK FOR SERVICE.Jan 12, 2025 · N655AE · Emb EMB145LR · Standard Practices/StructuresSDR HNAA2024070900536Thermostat · faultedBLD 2 VLV CLSD AFTER TAKEOFF MSG CLSD AFTER LANDING. FACT 09JUL24 00:03 PHL T/S IRW FIM 36-00-810-808-A DUE TO CMC PRECOOLER 2 TEMP CTL SYS FAIL MSG. R/R E2 FAN AIR CONTROL THERMOSTAT IAW AMM 36-11-06 R/R E2 BLD VLV IAW AMM 36-11-05 PERFORMED OPS CHECK IAWJul 8, 2024 · N655AE · Emb EMB145LR · Pneumatic Distribution SystemSDR HNAA2024070100499Controller · faultedPRESSURIZATION RISING DURING CLIMB WHILE RUNNING QRH PRESSURIZATION GOR HIGHER AND NORMALIZED AT 10,500 FT. PERFORMED OPERATIONAL CHECK IN AUTO AND MANUAL IAW 21-31-02 CND. R & R DIGITAL CONTROLLER IAW MM 21-31-01, OPS CK GOOD.Jun 30, 2024 · N655AE · Emb EMB145LR · Cabin Pressure ControllerSDR HNAA2023122700496Unknown · unknownFO W/S COMPLETED CRACKED DURING CLIMBOUT. R&R WINDHIELD IAW AMM 56-10-01.Dec 26, 2023 · N655AE · Emb EMB145LR · Flight Compartment WindowsSDR HNAA2023120800460Unknown · unknown00162 LHS CABIN FLOOR SILL IS CORRODED AT FRM 40, REMOVED AND REPLACED L/H CABIN FLOOR SILL P/N 145-25800-009 AT FRAME 40 IAW EMB 145 SRM 51-40-02Nov 18, 2023 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2023120800459Unknown · unknown00161 RHS CABIN FLOOR SUPPORT DOUBLER LOCATED AT FR 22 Y 479.O IS CORRODED. REMOVED AND INSTALLED NEW SERVICEABLE R/H CABIN FLOOR SUPPORT DOUBLER P/N 145-22461-011 LOCATED AT FRAME 22 Y 479.0 IAW EMB 145 SRM 51-40-02.Nov 18, 2023 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2023120800458Unknown · unknown00160 CABIN FLOOR SUPPORT ANGLE LOCATED AT FRM 20 Y 0.0 @ Y-479.0 IS CORRODED. REMOVED AND INSTALLED NEW FLOOR SUPPORT ANGLE P/N 145-20600-603 AT FR 20 Y-479 IAW EMB-145 SRM 51-40-02Nov 18, 2023 · N655AE · Emb EMB145LR · Fuselage Main, Floor BeamSDR HNAA2023090200329Unknown · unknownDAU 1B FAIL AFTER TAKE OFF, R & R DAU 1 IAW ANN 31-41-01. OPS CHECK GOOD. A/C OK FOR SERVICESep 2, 2023 · N655AE · Emb EMB145LR · Indicating/Recording SystemSDR HNAA2023031000071Unknown · unknownBRAKE OVER TEMP AMBER IND WITH ASSC EICAS MSG ON O/B R/H BRAKE AFTER T/O FACT 11MAR23 12:24 R+R BRAKE CONTROL UNIT IAW EMB 145 MM 32-41-02 AS REQUIRED REF LP 280707 SEQ 3 FOR EVAL FLIGHT Mar 11, 2023 · N655AE · Emb EMB145LR · Landing Gear Brake SystemSDR HNAA2023011300021Starter · failedON NR 1 ENGINE START, ENGINE SHOWED NO ROTATION. AND EXCESS SMOKE WAS SEEN. GROUND CREW SIGNALED ENGINE FIRE BUT DID NOT USE FIRE BOTTLE. NO RELEVANT MESSAGES ON EICAS. REMOVED AND REPLACED THE NR 1 ENG AIR TURBINE STARTER IAW AMM 80-10-01 OPS CHECK OF ENG Jan 12, 2023 · N655AE · Emb EMB145LR · Engine Start Valves/ControlsSDR HNAA2022053100219Charger · inoperativeNDIS 655 33-50 0030050 29MAY22 RIC CLOSE LEFT AND RIGHT EXTERNAL EMERGENCY LIGHT ABOVE THE WINGS ARE INOPERATIVE. FACT 29MAY22 11:49 RIC UPON FURTHER INSPECTION FOUND #400 EMERGENCY BATTERY CHARGER ASSY. WAS NOT PROVIDING VOMay 29, 2022 · N655AE · Emb EMB145LR · Emergency LightingSDR HNAA2022021500079Not Reported · not reportedPDIS 655 21-31 2754131 14FEB22 CLT CLOSE AUTO PRESSURIATYION CONTROL INOP IN FLIGHT. MANUAL OPS NORMAL. DEACTIVATED OUTFLOW VALVE IAW 21-31-03-040-801-A. P/C C/B F-8 FACT 14FEB22 05:39 SBY REACTIVATED VALVES IAW AMM 2131-03-440Feb 14, 2022 · N655AE · Emb EMB145LR · Pressure Regulator/Outflow ValveSDR HNAA2022011700052None · nonePDIS 655 05-51 2711371 14JAN22 SBY ASSGN BIRD STRIKE CAPTS SIDE OF NOSE FWD OF WIPER DURING ROTATION. (NO ENGINE OR AIRSPEED ISSUES) HISTORY: NO AIRCRAFT CURRENTLY RECEIVING STRUCTURAL REPAIR TO DENTED AREA UNDER THE GUIDANCE OF EMBRAERJan 14, 2022 · N655AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR HNAA2021101400494Acm · failedIN CRUISE ODOR OF SMOKE PRESENT IN BOTH CABIN AND COCKPIT. ONCE ON GROUND COCKPIT TEMP INCREASED REGARDLESS OF TEMP CONTROLLER POSITION. INSPECTED PACK 1 AND FOUND ACM TO BE EXTREMELY HOT AND SEIZED. SMOKE SMELL CAME FROM PACK 1 ACM SEIZING AND NOW PACK 1 WOct 13, 2021 · N655AE · Emb EMB145LR · Cabin Cooling SystemSDR HNAA2021070100309Floor Support · corrodedL/H FLOOR SILL #3 IS CORRODED AT A PREVIOUS BLEND BETWEEN FRAMES 29-30. REMOVED AND INSTALLED SERVICEABLE LH #3 FLOOR SILL IAW EMB145 SRM 51-40-02.Jun 14, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100303Shear Tie · corrodedFR 65 SHEAR CLIP CORRODED AT CARGO DOOR LOWER SILL. CUT, POSITIONED, DRILLED AND INSTALLED SPLICE REPAIR ON FR 65 SHEAR CLIP AT CARGO DOOR LOWER SILL IAW ETD2021--145-019276 REV A AND EO1-53-21-0147.Jun 14, 2021 · N655AE · Emb EMB145LR · Fuselage Internal Mounting StructureSDR HNAA2021070100308Gusset · corrodedRH OMEGA BEAM GUSSET #3 CORRODED. REMOVED AND REPLACED RH OMEGA BEAM GUSSET #3 IAW EMB145 SRM 51-40-02.Jun 13, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100302Floor Support · corrodedCARGO DOOR CUTOUT LOWER FLOOR SILL CORRODED. REMOVED AND PERFORMED INSTALLATION OF SERVICEABLE CARGO DOOR CUTOUT LOWER SILL IAW EMB 145 SRM 51-40-02.Jun 13, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100307Floor Support · corrodedRH #2 FLOORBOARD SILL CORRODED. REMOVED AND REPLACED RH #2 FLOORBOARD SILL IAW EMB 145 SRM 51-20-03.Jun 12, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100306Floor Support · corrodedRH #3 FLOORBOARD SILL CORRODED. REMOVED AND REPLACED #3 FLOORBOARD SILL IAW EMB145 SRM 51-40-02.Jun 12, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100305Gusset · corrodedCENTER LAV OMEGA BEAM GUSSET CORRODED AT AFT END. REMOVED AND REPLACED CENTER LAV OMEGA BEAM GUSSET EMB 145 SRM 51-10-02.Jun 12, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100304Panel · corrodedRH LAV BANANA PANEL CORRODED AT LOWER END. REMOVED UNSERVICEABLE AND INSTALLED SERVICEABLE R/H LAV BANANA PANEL IAW EMB 145SRM 51-40-02.Jun 12, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100301Gusset · corrodedRH OMEGA BEAM GUSSET #2 CORRODED. REMOVED AND REPLACED R/H OMEGA BEAM GUSSET #2 IAW EMB 145 SRM 51-40-02.Jun 12, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100300Floor Support · corrodedLH #7 FLOORBOARD SILL CORRODED. REMOVED AND INSTALLED NEW LH #7 FLOORBOARD SILL IAW EMB 145 SRM 51-40-02.Jun 12, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100299Gusset · corrodedRH LAV OMEGA BEAM GUSSET CORRODED AROUND NIPPLES. REMOVED UNSERVICEABLE RH LAV OMEGA BEAM GUSSET & INSTALLED SERVICEABLE R/H LAV OMEGA BEAM GUSSET IAW EMB 145 SRM 51-40-02.Jun 12, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021070100298Floor Support · corrodedCARGO RH OUT BOARD FLOOR SILL CORRODED BETWEEN FRAMES63-65. REMOVED CORRODED CARGO RH OUT BOARD FWD FLOOR SILL, POSITIONED DRILLED AND INSTALLED SERVICEABLE FLOOR SILL IAW EMB 145 SRM 51-40--02, 51-20-03, APPLIED PAINT TOP COAT IAW EMB 145CPM 51-21-06 PIEDMONJun 12, 2021 · N655AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2021021300049Proximity Switch · malfunctionedLOUD NOISE FROM NOSE LANDING GEAR AREA HEARD AFTER GEAR RETRACTION, RAN QRH, CYCLED GEAR NOISE PERSISTED.(CAPT SAID GEAR LOCKED DOWN AND HE RETURNED BACK TO FIELD WITH AIRCRAFT) R&R'D NOSE DOOR SEQUENCE PROX SWITCH IAW 32-63-05-700-803-A AMM. SWUNG GEAR 8 TIMFeb 11, 2021 · N655AE · Emb EMB145LR · Landing Gear Retraction/Extension SystemSDR HNAA2020120200334Connector · damagedBAG BAY DOOR INDICATED OPEN ON TAKE OFF ROLL. R & R CONNECTOR P7216, IAW 20-50-00. OPERATIONS CHECK GOOD, CLEAR MEL.Nov 28, 2020 · N655AE · Emb EMB145LR · Door System WiringSDR HNAA2020033000113Unknown · fireRAMP AGENT REPORTED FLAMES FROM #1 ENG EXHAUST AT SHUT DOWN. MAINTENANCE: INSPECTED IAW RRMM 05-50-00. NO EVIDENCE OF OIL POOLING OR FIRE DAMAGE. STARTED #1 ENGINE AND SHUTDOWN WITH NO FIRE OR ABNORMAL SMOKE EXHAUST. OK FOR SERVICEMar 29, 2020 · N655AE · Emb EMB145LR · Engine (Turbine/Turboprop)SDR HNAA2019102800328Pressure Switch · failedPDIS 655 21-01 1886972 27OCT19 PHL CLOSE PACK 1 OVRLOAD FOLLOWED BY BURNING RUBBER SMELL NOTI CED IN CABIN AND COCKPIT. SMELL WENT AWAY WHEN PACK 1 WAS TURNED OFF. FACT 27OCT19 23:54 PHL R&R'D #1 PACK OVERPRESSUREOct 27, 2019 · N655AE · Emb EMB145LR · Cabin Cooling SystemSDR HNAA2019082600237Light · inoperativeRT OVERWING EMERGENCY LIGHT DOES NOT ILLUMINATE. REPLACED OVERWING EMERGENCY LIGHT ASSY IAW AMM 33-50-10-000/400-801-A. OPS CHECK GOODAug 23, 2019 · N655AE · Emb EMB145LR · Emergency LightingSDR HNAA2019082600236Connector · brokenEMERGENCY LIGHT AT SEAT 16A HAS BROKEN CONNECTOR. REPLACED EMERGENCY FLOOR LIGHT AT ROW 16A IAW AMM 33-50-12-000/400-801-A, OS CHECK GOODAug 23, 2019 · N655AE · Emb EMB145LR · Light System WiringSDR HNAA2019081900229Bulb · inoperativeR/H LATERAL PANEL EMERGENCY LIGHT INOP. R & R LIGHT BULB FOR RH LATERAL PANEL EMERGENCY LIGHTAug 18, 2019 · N655AE · Emb EMB145LR · Emergency LightingSDR HNAA2019061800175Light · inoperativeLEFT EMERGENCY EXIT ON THE TOP OF EXIT IS NOT WORKING. REMOVED AND REPLACED LIGHTJun 14, 2019 · N655AE · Emb EMB145LR · Emergency LightingSDR HNAA2019060300159Sign · inoperativeAFT EXIT SIGN FOR LH OVER THE WING ESCAPE HATCH DOES NOT ILLUMINATE. R & R AFT EXIT SIGN FOR LT OVERWING ESCAPE HATCH AT SEAT 12A IAW AMM 33-50-12-000/400-801-A, OPS CHECKED GOOD. OK FOR SERVICE.May 30, 2019 · N655AE · Emb EMB145LR · Emergency LightingSDR HNAA2019041100094Unknown · odor655 21-01 1854861 09APR19 PHF CLOSE ELECTRICAL BURNING SMELL IN COCKPIT IN FLIGHT AND ON THE GROUND. HISTORY: . FACT 09APR19 23:52 PHF MX INSP BOTH RELAY SUPPORT PANELS AND T/S IAW FIM 21 -20-00-810-80Apr 9, 2019 · N655AE · Emb EMB145LR · Air Distribution SystemSDR HNAA2019020100031Wheel · failedPDIS 655 27-12 2012781 31JAN19 PHL CLOSE WITHOUT CREW INPUT AIRCRAFT EXPERIENCED AILERON DISCONNECT ON SHORT FINAL AUDIBLE CLICK WAS HEARD JU ST PREVIOUS TO DISCONNECT. FACT 31JAN19 00:48 PHL R&R AILERON DISCONNECJan 31, 2019 · N655AE · Emb EMB145LR · Aileron Control SystemSDR HNAA2019012500029Control Panel · malfunctionedPDIS 655 05-50 2012692 23JAN19 PHL CLOSE ON APU POWER SMOKE WAS OBSERVED COMING OUT FROM ABOVE F/O RADAR CONTROLLER, BUT BELOW GLARESHIELD. PULLED ALL CARDS OUT AND SAW NO DAMAGE, STRONG ODOR AND SMOKE CONTINUED. PACK 2 WAS ON WITH CROSS BLEED OPEN. POWERJan 23, 2019 · N655AE · Emb EMB145LR · Weather Radar SystemSDR SIMA20180614002Light · inoperativeRT EXTERNAL OVERWING EMERGENCY LIGHT WILL NOT ILLUMINATE. R&R RT EXTERNAL OVERWING EMERGENCY LIGHT ASSY IAW AMM 33-50-10 OPS CK GOOD.Jun 14, 2018 · N655AE · Emb EMB145LR · Emergency LightingSDR SIMA2018053029003Light · inoperativeICU PANEL CABIN AND CABIN EMERGENCY LIGHTS WERE BURNED OUT. R & R THE CABIN AND CABIN EMERGENCY LIGHTS IAW AMM 20-13-04.May 29, 2018 · N655AE · Emb EMB145LR · Emergency LightingSDR SIMA2018053026005Sealant · failedDURING CLIMB, THE FLIGHT ATTENDANT REPORTED A LOUD NOISE COMING FROM THE RIGHT SIDE OF THE FUSELAGE. RETURNED TO DEPARTURE. INSPECTED THE AIRCRAFT AND FOUND THE RT WING TO FUSELAGE SEALANT HANGING DOWN. APPLIED SEALANT TO FORWARD WING TO FUSELAGE FAIRING May 26, 2018 · N655AE · Emb EMB145LR · Aerodynamic FairingsSDR SIMA20171125002Light · inoperativeRIGHT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R THE LIGHT IAW AMM 33-50-10-000-801. OPS CHECKED GOODNov 25, 2017 · N655AE · Emb EMB145LR · Emergency LightingSDR SIMA20171025004Cradle · crackedFLIGHT ATTENDANT FLASHLIGHT CRADLE CRACKED. REMOVED AND REPLACED FLIGHT ATTENDANT FLASHLIGHT CRADLE BASE IN REFERENCE WITH AMM 33-50-16-000-801-A & 33-50-16-400-801-A.Oct 25, 2017 · N655AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20170728001Bulb · inoperativeDURING PS-1 INSPECTION FOUND OVERBOARD EMERGENCY LIGHT ON RT AND LT WING TO BE INOPERABLE. REMOVED AND REPLACED THE RT OVERWING EMERGENCY LIGHT ASSEMBLY AND LT OVERWING EMERGENCY LIGHT BULB IAW AMM TASK 33-50-10.Jul 28, 2017 · N655AE · Emb EMB145LR · Emergency LightingSDR SIMA20170722001Lamp · inoperativeWHILE PERFORMING PS-1 CHECK, FOUND RT OVERWING EMERGENCY LIGHT LAMP NOT WORKING. R & R THE LAMP IAW AMM 33-50-10. OPS CHECKED GOOD.Jul 22, 2017 · N655AE · Emb EMB145LR · Emergency LightingSDR SIMA20170618001Lamp · inoperativeFOUND EXTERIOR RT OVERWING EMERGENCY LIGHT INOPERATIVE IAW PS-1 INSPECTION. R & R THE LAMPS IAW AMM 33-50-10, OPS CHECKED GOOD.Jun 18, 2017 · N655AE · Emb EMB145LR · Emergency LightingSDR SIMA20170510002Lamp · inoperativeMAIN DOOR OVERHEAD EMERGENCY LIGHT INOPERATIVE. R & R THE LAMP IAW AMM 33-50-06-000-801-A, & 33-50-06-400-801-A. OPS CHECKED GOOD.May 10, 2017 · N655AE · Emb EMB145LR · Emergency LightingSDR SIMA20170413002Lamp · inoperativeRIGHT CENTER FUSELAGE FAIRING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-50-10.Apr 13, 2017 · N655AE · Emb EMB145LR · Emergency LightingSDR SIMA20170308002Connector · shortedDURING DESECENT, HAD A LANDING GEAR AIR GROUND FAIL MESSAGE ILLUMINATE ON THE EICAS, AS WELL AS A NR 1 & 2 ENGINE REVERSER DISAGREE, FOLLOWED THE EMERGENCY ABNORMAL CHECKLIST, THERE WAS NO INDICATION OF REVERSERS OPEN. FOUND THE AIR / GROUND CIRCUIT BREAKERMar 8, 2017 · N655AE · Emb EMB145LR · Landing Gear System WiringSDR SIMA20170212004Lamp · inoperativeRIGHT AFT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A, OPS CHECKED GOOD.Feb 12, 2017 · N655AE · Emb EMB145LR · Emergency Lighting
Back to N655AE